HomeMy WebLinkAbout01D1606M
Level(3)
COM MUNI CAT IONS
FIBER-OPTIC CABLE ROUTE
AS -BUILT DRAWINGS
FOR LEVEL 3 COMMUNICATIONS
PORTLAND, OR TO SEATTLE, WA
PROJECT SPAN
Auburn, Washington
a
n1 n tAAA
As -Built Annotation
Description
Options
Duct Type
H = HDPE
P = PVC
Z = Other
Duct Bank Count
2, 3, 4, 6, 8,10,12,14,16,
18, 20, 22, 24, 26, 28, 30
Z = Other
installation Method
A = Attachment (i.e. bridges)
(other than plow or trench)
B = Bore
Z = Other
No annotation if duct is plowed/trenched
Duct Bank Casing Type
F = FRE casing
H = HDPE casing
P = PVC casing
S = Steel casing
Z = Other
Duct Bank Casing Size
8 = 8 inch casing
9 = 9 inch casing
10 =10 inch casing
12 =12 inch casing
2`5 = 2-5 inch casing
2*6 = 2-6 inch casing
Z = Other
Duct Bank Encasement
C = Concrete
Q = Flowable fill
M = Multicell (integrated duct and casing system)
T = Steel plate on top of duct bank
Z = Other
Duct Bank Caver Depth
Inches
20 (20" or less)
20140
40160
601100
100 (100" or more)
Surface Restoration
PR = Pavement Restoration Roadway
PW = Pavement Restoration Walkway
Handhole
HHA = FRP: API Model:134800-42, concrete cover
HHB = FRP: API Model:13-4800-42, cast iron cover
HHZ = Other
Manhole
MHA = FRP: API Model 134882-20, hatch doors
MHB = FRP: API Model 13-4882-45, cast iron cover
MHC = Manhole, 4.0'x 4.0'x 4.0'
MHZ = Manhole (other)
Drawn Quality Control A pproved Owner.
SM
The locations of utilities shown on this Rev Description By By I Date by Date
^'•,ving are only approximate. Level 3 Level
,nmunications, LLC hereby disclaims
(3)
any responsibility to third parties for the COMMUNICATION S
accuracy of this information. Persons
working in the area covered by this CALL BEFORE YOU DIG �°n�``°r '
drawing must contact the statewide 1-800-332-2344 Kiewit Network Services Co.
Call -Before -You -Dig System to ascertain 48 HOURS NOTICE Engineer.
the location of underground utilities prior REQUIRED ' o
-�-
to performing any excavation.
Program: Intercity Network
City Pair: Portland to Seattle
Package Title: Portland to Seattle
Drawing Title: Portland to Seattle
City Pair Code Type Dry "1 40 4er Sheet No
PORSEA S P 000 A 1 of 1
SEC 25, T21N, R4E, W-Y,
ALUUNA & AU,�Uf�N, WA
o
D
o....; UPRR
- - R>W R7W R/W W
.--� Z R!-
1 o
C) Q
v
3 LLJ '
Z p
L3
Q
R/W R/
H-12 R/W R/ H-12 R/W HR�W It/W H-12 R/W
LEILLJ
--1
U
— ^ ^
u3 to LO
Q rnLn
rn
12 1-1/4"
HDPE DUCTS
DUCT SYSTEM DETAIL
NTS
1
1�
,._... ...... � ...... ...._.._
M
N N
N
v �
(if
+: i
of
co
M
M
N
N
cop
O
I I
O C3
d 00
N
2 t
v
Z 0
0
a
N (N
M
(if c
O
W Y
Y
+
Ir
M
�
O)
cp �
rn 'a'
N rn
+
cp
N
PO
+
cr
N
M
Ce
�.
v
O
Z Z
l
N
�.
ro N
N
O m
OI
O
O
m
2
.-
O
� Q
O 1L0
I
�2
^
0
O
J
O
2
_
UIU
o
=
0
o
z
Z
_
r-
=
cr
Oo
N
w
Y
+
+
=
n
"i
v
LLJ
�
o
m
+
O
M
C.�
W
m
0..
O
Ln
+
co
rn
0
o to
14-
Lr)
Z
C:] I
�-- M
Qo
F - I4
L7
LL 3
ZQ
J LLJ
=rJ
U L�
100' 50' 0 100' 200'
SCALE: 1 "=1 OD'
prawn Qual' Control Approved owt,er
The locations of utilities shown on this Rev Description By y Date y a �, Program: Intercity Network
drawing are only approximate. Level 3 DDE SGD 3-7-01 City Pair: Portland to Seattle
Communications, LLC hereby disclaims Level(3)
any responsibility to third parties for the Package Title: Auburn
COMMUNICATIONS
accuracy of this information. Persons +40 - 40+10
working in the area covered by this CALL BEFORE YOU DIG Drawing Title: MP 159 STA 26
drawing must contact the statewide 1-800-332-2344 Kiewit Network Seances Co. CKYP&Ca& SO„Sim Tre I DEN& %V V"4M
Call -Before -You -Dig System to ascertain
the location of underground utilities prior 48 HOURS NOTICEAIPE" o o P 0 RS EA S IP1159CIAl 1 of 22
to performing any excavation. REQUIRED —W
0
U CD
ONV
�Z
I �
O Q
w
Az
W�
W-)
Q
R/W
— R/W
R/W
SEC 25, TPIN, R/1E, W.M.
ALGUNA & AUBURN, WA
UPRR
R/W ....... _..�:_.._.Rl"it..,:............... R/W
ALGONA CYTY LIMITS
R/W
AUBURN CITY LIMITS r r
.,R.
12
_ _
.. H 1�
R/W
0000
. 00 �i
+
M
00
p�
+
�*
N
'+
�
N
N
+
+
CN N
N
N
N
N
—
N —�
�— N
tr
of
Cr
Q.
of
of
Qf
v
G sF
d
ac
v
N to \
\
M
N
N
�D
to
O
O
C3
�
O
O N
C)2
_N
2
O
O
j
O
O
N
.—
CV
z W
m
a-
tn
Z
of
a
a
En
Y p
rn
w
Y
w
Y
+
_
—
+
+
W
al)
to
to O
N
+
f+
O +
0
fO
,--q
co
CLI Q
Lr)o
Z
0�
� I
O
QUl
C4
w3
Z la
Jw
=W
F
a
12 1-1/4"
HDPE DUCTS
100' 50' 0 100' 200'
DUCT SYSTEM DETAIL SCALE: 1 "=100'
NTS
The locations of utilities shown on this Rev Description Drawn Qual' Control Approvad OWW. Program:
drawing are only approximate. Level 3 BY y Date y a 9 Intercity Network
Communications, LLC hereby disclaims DDE SGD 3-7-01 Level(3)City Pair: Portland to Seattle
any responsibility to third parties for the Package Title: Auburn
accuracy of this information. Persons C o M M u N I C A T I 0 N S
working in the area covered by this CALL BEFORE YOU DIG C°^baW Drawing Title: MP 159 STA 40+10 - 52+81
drawing must contact the statewide 1-800-332-2344 Kiewit Network Services Co.
Call -Before -You -Dig System to ascertain Rpm "' Tti" � 4& � qp" 4&
the location of underground utilities prior 48 HOURS NOTICE : • o
to performing any excavation. REQUIRED �, PORSEA S P 159D A 2 of 22
r�
SEC 24, T21N, R4E, W.K
ALGONA & AUBURN, WA
-; Q`w ...,:,.� .::..f UPRR
�0 U
-,0 W R/W C0
Z Z R/W R/W R/W R/W R/W R/W
CL U wC.%Z
CL
t'7
Q °' � 1 �° ALGONA CITY LIMITS �� Q C)F--
--/—Bo00446 i _:� 1° ° o [ o°o°AUBURN CITY LIMITS o000 L3
A Z H-12 H=I — —12 L,J 3
,R/G! R/W R/W R/W =R/W R/W R/W R% Z A
__. _._._ .•\.............. '4{ ...��.. - __ ...-... .........._..--------------•----- -_.__ ---- •l• h•-)
J
W: - — -- - .- - _.........- - :. _ - _ - - - W.-.. W
4
r•
} +
Q b Q i + CD +
Do � CO Q
14,
of '
\ M W) M K) L
t0 O
O N N
N
m N
OI ^ �
I
t O 0 � O OI
0 2 2 0
`W
2
2\2 1 0 zo 0:
Z N O
_ fN
\ W fr
I W p
N Z Y
O W � W
^ Y
\
v 00
+ a W tD
GO
m no N
N +
O to
W N
m
O
r`
\t+2
12 1-1/4"
HDPE DUCTS
\ 100' 50' 0 100' 200'
DUCT SYSTEM DETAIL
NTS
SCALE: 1 "=100'
Drawn Qual, Control Approved °""'°' Program: Intercity Network
The locations of utilities shown on this Rev Descriptionyy Date y a �
drawing are only approximate. Level 3
Communications, LLC herebydisclaims DDE SGD 3-7-01
Level(3)
City Pair: Portland to Seattle
any responsibility to third parties for the Package Title: Auburn
accuracy of this information. Persons C O M M U N I C A T I O N S 9
working in the area oovered by this CALL BEFORE YOU DIG c01h Drawing Title: MP 160 STA 13+20 - 26+40
drawing must contact the statewide 1-800-332-2344 (a Kiewit Network Services Co.
Call -Before -You -Dig System to ascertain a,y P,r, coft S„+4& T�" N" 4k %W sh" 4&
the location of underground utilities prior 48 HOURS NOTICE
to performing any excavation. REQUIRED P 0 RS EA 60 B A 4 of 22
0
d-
R/W
.—, Z
O
CD Q
V�
LD
to ? R/W —
LJLjj
10
= i
F—
Q
12 1-1/4"
HDPE DUCTS
DUCT SYSTEM DETAIL
NTS
The locations of utilities shown on this Rev
drawing are only approximate. Level 3
Communications, LLC hereby disclaims
any responsibility to third parties for the
accuracy of this information. Persons
working in the area covered by this
drawing must contact the statewide
Call -Before -You -Dig System to ascertain
the location of underground utilities prior
to performing any excavation.
R/W
ALGONA CITY LIMITS
R;'1
rxti
SEC 24, T21N, R4E, W.M.
AL_GONA & AUBURN, WA
.,_UPRR
R/W
R/W -
r5
-rV
AUBU N CITY LIMITS 000( I _ oov-
o . H JiW
-----
R/W H 12 R / �l`- ` .'..1�/ W ...-- ----- ------------ / W •.. V -j---_ t
• _.. ......__ ----y -....-..
12
„H
n i4r
- -
r7
1W
rn
N
N
1
O
O
O
0
2
z
c.I)
Cn
of
w
Y
0=
rn
n
LO
pn
lion Drawn QualityA Control roved """°"
Description By Date By Date SM
DDE SGD 3-7-01 Level
C O M M U N I C A T I O N S (3)
CALL BEFORE YOU DIG
1-800-332-2344 eKieftwNetwork Services Co.
48 HOURS NOTICE E"A�'°°`nim _ ' o
° REQUIRED --
R/W
0
�O
MQo
R/W
CD
Q o
�— fn
C4
0
Lj
Z Q
-------------------- ---- ---
—� LJ
= LJ
U L6
100' 50' 0 100, 200'
SCALE: 1 =100'
Program: Intercity Network
City Pair: Portland to Seattle
Package Title: Auburn
Drawing Title: MP 160 STA 26+40 - 39+60
CNy Pet Coda 3pen No Tr' D",On, No. Rav meal No
PORSEA S I
P I 160C I Al5 of 22
°=11� 9 9974
CD :03 IA
C S� N fa O C
d �q
g = a = o " SEE DWG S03-P160C
�� -- -�
x a s & MATCHLINE STATION 39+60
g 3 sg � gsa w
yam
a,
o�CD
m
s•c
O
H
o. y W w
_ 40+62 MARKER SIGN-0000-1244 42'R
(RR 124+31)
pN
'D
m
I
;
a 3
a 3
o • C3• C
2
H
� � O
0 -
V/
n
01
O
0-00-0
cc
co a,
co (D
(n � � o
D
U C O
-D iCr ;:I. CD o
o �.
a
0 N CD
D g
w CD n
O D
+CD
m
o
CT o
O w o
+ 1
O o
o)
o
r�
N
NO o
PQ o
42+00 PI (1-112-40/60) 35'R
122+93)
b
44+89 PI (H12-40/60) 29'R (RR 120+04)
45+51 MARKER SIGN-0000-1245 44'R (RR 119 i42)
i
.�2
StA
I
\
£
r2
1rs
P� gEG g0o441`
49+9Q � 4+42i �
KER ;jGN �OQQ
50+25
SA
15�N S 70
- 43+00 FO LINE XING GOING
I I
ps
'VZ
IVA'X , as.
`1NE- MC1 33 R
5p.�0
A O
0
g000 48
C 000
32R 2,�g3i o0
OG�2��� 3gR ERR k3 °-
S`GN ,�OQ 4Q rod)`,��2 RR 1 ,2k24 DNS 36 R
KER M�2� EG 6GR� 31�R RR 12k22 \ ENE SPNG
52�60 M Np BGRk6Q P� ggOG4 3l R RR >>2�N6�
52'`6Q P\ 52 rQQQO' 41 5g`1" RR669
HPa`��RS G ~ pOQQ' 60i 59/ ` _ol
k69
52��
52-VI MARK o eoRE
P� EN 53
52k��
LZNE S 5�3,P
MPS SEE �� �'
D FTI
V)
F
C1 n
Cro
Z
D-
SEC 13, T21N, R4E, W.M.
AUBURN, WA
W
U U U
> Z Z
W X X
N W W
W Z_ Z
W J J
O
`n h LO °o
r`
O p
CN
+ : °�
MN UPRR ;
_ R/W R/W _ H_1 R/ W — -R/W H_ R/W R/W R/W . i/W
'—' a-
0 t]0-
C) Q o
l7 E 1 t_7
3 w 3
w
A Z /W R/W i R/W R/W .. R1W ' Z A
W J --
`f.._._� r: -J LLJ
W = E • '; = LLJ
Q f t o c�i o O
FR/W Q
r N N Ln
+ + + + + +
►n M r N r r r r r N
r
C of
e of
J J J J J v
N M N to N J
In to u1 rn to
� � �� to
\ �\ to CN to toN to
O O O \
tV p N N O
= O = = O N
a z a s z .�
a
En
N CC h0 GOo
O Y r7►7 Y
M M M 00
M
M h
h to
+ +
r7 rrn
12 1-1/4"
HDPE DUCTS
DUCT SYSTEM DETAIL
NTS
100' 50' 0 100' 200'
SCALE: 1 "=100'
The locations of utilities shown on this Rev Description By pawn a y Qual' Control Approved a e °inner Program: Intercity Network
y
drawing are only approximate. Level 3 SM City Pair: Portland to Seattle
Communications, LLC hereby disclaims
DDE SGD 3-7-01 Level(3)
any responsibility to third parties for the Package Title: Auburn
aca�racy of this information. Persons COMMUNICATION S
working in the area covered by this CALL BEFORE YOU DIG c sdo� Drawing Title: M P 161 STA �6+40 - 39+60
drawing must contact the statewide 1-800-332-2344 Kiewit Network Services Co.
To•
Call -Before -You -Dig System to ascertain
the location of underground utilities prior 48 HOURS NOTICE IMAM
o PORSEA SIP1161CIAl9 of 22
to performing any excavation. REQUIRED —�,
C)
0
A +
tU o
� Z
n O
C Q
0
3Zoo
A �—
W = •`J
W U
0 t--- �-
12 1-1/4"
HDPE DUCTS
DUCT SYSTEM DETAIL
NTS
The locations of utilities shown on this
drawing are only approximate. Level 3
Communications, LLC hereby disclaims
any responsibility to third parties for the
accuracy of this information. Persons
working in the area covered by this
drawing must contact the statewide
Call -Before -You -Dig System to ascertain
the location of underground utilities prior
to performing any excavation.
SEC 12, T21N, R4E, WX
KING COUNTY, WA
UPRR
RlG�;- R/W
FZfW R/W R/W
R/W R/W
1�
0
000
00
R/W
N00LO
M
+ +
+
+
01
W) �
of of
Ce
v
Cr
0:
1-0
t
o:
cc
to
^ M
M
�
N
N
O
.i
0
0C14
Z
x
O
t
O
i'
o
CD0
Uj
0
i
O
N
N
M
0
tr
Y
Y
W N
ADO W
co
00
+
LO
to
+
+ Ir
�o
M
0
W
M
a
0
N
Description
R/�
0
t1.1
+ Q
�D
Z
O I
Q CD
3 W
Z A
�1
J W
= W
100' 50' 0 100' 200'
SCALE: 1 "=100'
oWW. Program: Intercity Network
City Pair: Portland to Seattle
eVeLk Title: Auburn
(@ COMMUNICATIONS Pac age
CALL BEFORE YOU DIG �^ Drawing Title: MP 163 STA 0+00 -13+20
1-800-332-2344 Kiewit Network Services Co. Ck,P*c4m sw, rmo gym. %w ��
48 HOURS NOTICE : o o PORSEA S I P-t 163A A 15 of 22
REQUIRED —M
SEC 12 & 1, T21N, R4E, W,M,
KING COUNTY, WA
Irn+ UPRR V
/WI N
`RW
IZ
1,0
MC:) '- °
� F-- �� ~ o
Q �
LD o 0
3 LLJ R/W R/W--- _
qZ ` --� - 1 /W ZA
LJLJ
W r J LLJ
= LL1
t, to 00100 ^ V C4
~ m � Ln rn rn 00 I.—
Q
a a Ln f
I M o` o= Cr
of W of
v v
CL* re cr Cr CC cr
tf)
r` 0^� to V7 to
N ',-, O N N
N
I I O O 1 1
O �m 0 0O
O � O 0 O
O
Z I vo O O Z
Z W O W Z z
O I p N N
Imce- Cr O
Y Z O LLJ
y y
m Z
WN M
a O o
m e^+ I 1W too �^ N
0
Li
12 1-1 /4" I M
HDPE DUCTS a
100' 50' 0 100' 200'
I co
to
DUCT SYSTEM DETAIL SCALE: 1 =100
NTS
The locations of utilities shown on this Rev Description Drawn Qual' Control Appmved °WMr ram: Pro Intercity, Network
drawing are only approximate. Level 3 By Y a e y DaFe-- g �'
Communications, LLC hereby disclaims
DDE SGD 3-7-01 Level(3)City Pair: Portland to Seattle
any responsibli ty to third parties for the Package Title: Auburn
accuracy of this information. Persons C O M M U N I C A T I O N S
working in the area covered by this CALL BEFORE YOU DIG �^° Drawing Title: MP 163 STA 13+20 - 26+40
drawing must contact the statewide 1-80D-332-2344 Kiewit Network Services Co.
Call -Before -You -Dig System to ascertain °ods s4"' "° �• °�`°0 "° srw
the location of underground utilities prior 48 HOURS NOTICE E�f°°rRMS
to performing any excavation. REQUIRED = P 0 RS EA S P I 163 B A 16 of 22
SEC 36, T22N, R4E,W.M,
AUBURN, WA
0 I0
+ 0pq +
`°� R/w UPPR CnV
Z ,,; 'R.c�✓ R/W �RlW _.; R/W R/Wr — _--R/W R/W Z .�
0 _
of
o Q I—
0 Q C)
B000455 000457 �
LD 3 B000458
W Ill Ip
q Z J W 3
Z q
W J R/W R/W R/W R/W R/W R/W R/W R/W
LjU =W
Q ^ ^ _ FU—
N N N I ^ ^ Q
+ + + + M
N N r` r` + +
N N
W of
of
v v Cr C
O 0 0 S
N rn r7 Pn 0 C-4
O r,� O a)^ m
t0 � ^
to ,d O to
O O O O \ Op
O
mj tV opit m r. •
N
N
2 ^ _^
v O v O = ^e
W O O v C)W W _ O
o I I a
m m
N O'J N i m
O 04 N st
Z v _ +
W Z v
o
to m C) M
r`
+ O +
to m P0 W ;' CO
N m M
O O i
t7
12 1-1/4"
HDPE DUCTS
100' 50' 0 100' 200'
DUCT SYSTEM DETAIL SCALE: 1 "=100'
NTS
The locations of utilities shown on this Rev Description
Dawny y ay a �
Qual' Control A Pro9ram:
roved owner Intercity Network
drawing are only approximate. Level 3
Communications, LLC hereby disclaims DDE SGD 3-7-01 Level(3)City Pair: Portland to Seattle
any responsibility to third parties for the Package Title: Aubum
accuracy of this information. Persons C 0 M M u N I C A T 1 0 N S
working in the area covered by this ," Drawing Title: MP 164 STA 26+40 - 39+60
drawing must contact the statewide CALL BEFORE YOU DIG
��
Call -Before -You -Dig System to ascertain 1-800-332-2344 Kiewit Network Services Co. F,,cd, st,,b• ,ypw Da �. %W �%i
the location of underground utilities prior 48 HOURS NOTICE En*mw..
to performing any excavation. REQUIRED, PO RS EA S P 164C A 21 of 22
0
§
�� to w c
oagao
0
08 �' m
K CD {�' N O rr
cn -- 8 g C) a
cn
z cn
D�
a �Dr-
o
m g U. y o
WCD M (D H o Q
rTl
D
-0.co � wm
f pN
rq -�
I
c�
N�
9
_
�r
o T
m cc
N
Q
c
NX
m0
vdo
N�
m
v
G�
-0 n
CD
m
D
..v c O h `-"
o
Q ;:I- CD
C F n
3 fl.
cn
CD o � Co
w m o3 r
m
o m n'
�►
+ o_
0
N
o
0
D
N
O
N
N
o
IV
SEE DWG S03-PI64C
MATCHLINE STATION 39+60
.ty
.;.. '
I
I£
42+68 PI END BORE (1-112-40/60) 42'R (RR 36+10)
43+00 PI (1-112-40/60) 35'R RR 36+42'
43+00 HANDHOLE-00001279 35'R ((RR 36+42J
43+00 MARKER SIGN-0000-1279 30'R (RR 36+42)
43+80 PI BEG BORE (H12B-100)-13100460 30'R (RR 36+42)
47+45 PI END BORE (1-112-40/60) 30'R (RR 40+87)
47+61 PI BGN BORE (H12B-100)-B000456 30'R (RR 40+93)�
Es
I
IN
4..4
`\
279
�0
o,
N
C
11
�
50+28 MARKER SIGN-00001280 43'R (RR 43+70) 0006
CITY OF AUBURN S. 277TH ST.
KING COUNTY
51+86 PI END BORE (1-112-40/60) 26'R RR 45+28
51+89 MARKER SIGN-00002116 26'R RR 45+31
51+89 PI (1-112-40/60) 28'R RR 45+31 21�t,
51+89 HANDHOLE-00002116 28'R IRR 45+31 0, I
0
�i
52+52 PI (H12-40/60) 32'R (RR 45+94)
MATCHLINE STATION 52+52
SEE DWG S03-PI65A
CITY OF KENT
LP
V)
m
n