Loading...
HomeMy WebLinkAbout10D2016SIUP „�,. - N� S E ION 7 TOWNSHIP 21 N RANGE:15:�.E.,.N.M. 1 \ 4� , ' " 2 ST N E N89 47 05 E 7T9. 0 -� -•-� -� � TIAL) A� RESIDEN FOUND 2 BRASS DISC o. ....�p,�, o WITH PUNCH INCASED AT Q 260.00 , .. S HP. THE INTERSECTION OF I a° 4 STREET NE & 26TH STREET NE SITE - BENCHMARK N0.2 � l ELEVATION 58.09 FEET- . . . . . . . . . . °� `� sicN $ -� POWER POLE W/TRANSFOR z S$9 47 21 "W 3' WOOD FENCE 30' . 22.07' - --N89.47'05"E 207.93' - - - . ® - - - - c B-POWER a - --- - - - �-- ° ° .. ° e d LLY WIRE ANCHOR ` ° / . $ W 6 C ONE FENCE OQ :5" a " W 01 a N 29 /`L.O „ 35 48 DC-, 18 FIR 14 FIR 1g"cD 8' 52' 1 z 28 FIR' TWIN TWIN �� e N I0��0' �1 / x , a..° 16 FRUIT TREE I I x 24 e I BENCH 20" G�� 6' CYCLONE FENCE TWIN d e l a 2 38" FRUIT TREE QUAD QP� �0'0 „ xw w. d . �' 25 _z I W J >�o 0� o I 48" DEC OUS d IN I o ° 36" CLUSTER 0„ TWIN DECIDUOUS 39 >, ° I x a AMATEUR RADIO 34 POKR CABINET ANTENNA f� z ° I ° AGROUND ROD FAUCET x c, .. Izl x NEW 15 PUBLIC NEW PROPERTY WATER EASEMENT I LINE PER TRANSF0"IrzR I N I o . a • . INSTALL PERVIOUS BLA08-0016 CONC' PER DTL 7/C4 RESTORE ASPHALT PAVEMENT PER W Q Zo„ nrnini G is N89.50'16"E 230.00' COA STD DTL TRAFFIC-02. EXTENT d- - - - - - - - - - - - Z w >; ° 61 1 TY OF PATCH TO BE FIELD -DETERMINED. I �• F- ¢ z cV a c a an ono as t;tY an a �c `yGr ,c v , , I r` LO (�JIny00 '�\ .~2 CV ` Ua J C� 6`>1 i G;70 U i.3C,a,.n J CGG� � y\\\.\\, � � V pGUY WIRE ANCHOR °t'° 'G't ary $` INSTALL ADA PARKING \ N w Q T nv a. e ?u r to cc a x.ry O \ • SIGN PER DTL 3/C4 \ c x C1 Q �� ^\�O •1`,. (Jl C C f. 4a a J J O J U J J ary Q (� INSTALL CURB RAMP 5�0' PER DTL 8/C4 o 40 ) , I NEW 24.0 COMMER IA � 0 \ ` ^ ��, <^, • � � POWER POLE W RANSFORMER . . . \,,j '' `1' TYP D/ P R COA ST \, INSTALL CONC S/W & UNDERGROUND POWER T AFFI 9 C 0 / PER DTL 2 C4 c+a< u` ra ILA,of a ` ' \l� °zs o .� e c o sK INSTALL ASPHALT PAVEMENT ` a,J G << a r <> a a \�, a ll 0 , °a u,eM AND EXTRUDED CONC CURB 3` Q ` ` PER DTL 1 /C4 3.0 G ; G C a O Q C, a C': C3 F, C „ J l a.4 J D C.�'. Q GARBAGE & RECYCLING AREA. SCREENING PERCi ARCH PLANS. Q , ,` . �w: ..�\., ,'�. .�� ..fit � .,, {;. `ti1� \ ''�\\ ,' ��i\, \, �a. , \` � �\\v` �. ., ,,• �:��:` \ ,,;�E �, ;�L. \� , a` \., 0. a I FENCE -ENCLOSED "COMPACT" TO BE STENCILED GARDEN GJ �° ON EACH COMPACT PARKING; I 10' WATERLINE t",1 \ NEW PUBLIC SPACE W/WHITE BLOCK LETTERS 6 10 RECEAS. NO.T3832556 Q P WATER EASEMENT RESTORE ASPHALT PAVEMENT PER COA STD DTL TRAFFIC-02. EXTENT OF PATCH TO BE FIELD -DETERMINED. \��' INSTALL 4" STANDARD INSTALL NEW S/W, CURB, \, CONC PATIO SIM TO DTL 2/C4 (TYP) AND GUTTER PER COA\ STD DTL TRAFFIC-24 "�`' X x X X X' x 6' CYCLONE FENCE ° S89 5016 Z30.00 G�� WOOD FENCER w -0 P� �� W V o o ti Qf ............ v. . . . . . . . . . . . d ° GENERAL NOTES SITE PLAN 1 VALLEY CITIES COUNSELING FAITH RICHIE, CEO 2704 1 ST NE AUBURN, WA 98002 (253) 876-3425 ENGINEER RUPERT ENGINEERING, INC. ADAM E. PAUL, PE 1519 W VALLEY HWY N, STE 101 AUBURN, WA 98001 (253) 833-7776 ARCHITECT THE KEIMIG ASSOCIATES ALAN KEIMIG 216 A STREET NW AUBURN, WA 98001 (253) 939-3232 SURVEYOR CENTRE POINTE SURVEYING STEPHEN H. WOODS, PLS 206 RAILROAD AVENUE NORTH KENT, WA 98032 PH: (253) 813-1901 SHEET INDEX C1 SITE PLAN C2 TESC & DEMOLITION PLAN C3 GRADING, DRAINAGE, & UTILITIES PLAN C4 DETAILS & SECTIONS L1 LANDSCAPE PLAN IR1 IRRIGATION PLAN Al SITE LINE STUDY LEGAL DESCRIPTION- 28th Street NE 13 Q D a � . U CA D 00 0 Q 26th Street NE Q� Auburn J ao 26th Street NE > `D PROJECT SITE U C14 oo 0 o d W W `N' Z _ C b U, 0 Z Z T ,D W 3 24th'Street NE r` r\ v M VICINITY MAP�� -1 Q 00 N TS Z Ln � U U �Q� NEW PARCEL A: BEGINNING AT THE SOUTHWEST CORNER OF LOT 6, BLOCK 2, MAPLEWOOD ADDITION TO THE CITY OF AUBURN, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 17 OF PLATS, PAGE(S) 98, IN KING COUNTY, WASHINGTON; THENCE NORTH 00.23'05" WEST, ALONG THE EASTERLY MARGIN OF "I" STREET NORTHEAST, A DISTANCE OF 132.03 FEET; THENCE LEAVING SAID EASTERLY MARGIN NORTH 89'50 16 EAST A DISTANCE OF D 230.00 FEET, TO THE EASTERLY MARGIN OF VACATED ALLEY, AS VACATED SEPTEMBER 18, 1967 BY CITY OF AUBURN ORDINANCE NUMBERS 2209 AND 2128; THENCE SOUTH 00'23'04" EAST, ALONG THE EASTERLY MARGIN OF SAID VACATED ALLEY, A DISTANCE OF 132.03 FEET, TO ITS INTERSECTION WITH THE EASTERLY EXTENSION OF THE SOUTH LINE OF SAID LOT 6; THENCE SOUTH 89'50'16" WEST, ALONG SAID SOUTH LINE, A DISTANCE OF 230.00 FEET TO THE EASTERLY MARGIN OF "I" STREET NORTHEAST AND THE POINT OF BEGINNING. NEW PARCEL B: COMMENCING AT THE SOUTHWEST CORNER OF LOT 6, BLOCK 2, MAPLEWOOD ADDITION TO THE CITY OF AUBURN, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 17 OF PLATS, PAGE(S) 98, IN KING COUNTY, WASHINGTON; THENCE NORTH 00'23'05" WEST, ALONG THE EASTERLY MARGIN OF "I" STREET NORTHEAST, A DISTANCE OF 132.03 FEET TO THE TRUE POINT OF BEGINNING; THENCE CONTINUING ALONG SAID EASTERLY MARGIN, NORTH 00'23'05" WEST, A DISTANCE OF 66.41 FEET TO THE BEGINNING OF A CURVE TANGENT TO SAID LINE; THENCE LEAVING SAID EASTERLY MARGIN NORTHEASTERLY DISTANCE OF 34.62 FEET ALONG THE CURVE CONCAVE TO THE SOUTHEAST, HAVING A RADIUS OF 22.00 FEET AND A CENTRAL ANGLE OF 90'10'10" TO THE SOUTHERLY MARGIN OF 26TH STREET NORTHEAST; THENCE NORTH 89'47'05" EAST, TANGENT TO SAID CURVE, ALONG SAID SOUTHERLY MARGIN, A DISTANCE OF 207.93 FEET TO THE EASTERLY MARGIN OF VACATED ALLEY AS VACATED SEPTEMBER 18, 1967 BY CITY OF AUBURN ORDINANCE NUMBERS 2209 AND 2128; THENCE SOUTH 00'23'04" EAST, ALONG SAID EASTERLY MARGIN OF VACATED ALLEY, A DISTANCE OF 88.69 FEET; THENCE SOUTH 89'50'16" WEST, A DISTANCE OF 230.00 FEET TO THE TRUE POINT OF BEGINNING. LEGEND CD DESCRIPTION NEW EXISTING z z ry STORM SEWER D - - - D - - - Q M SANITARY SEWER S - - - S - - - Z C' Q Q z WATER W - - -W- -- N CONTOURS 50 50 O SILT FENCE F Cn = POWER (OHP/UGP) - OHP/UGP - - OHP/UGP - W W ASPHALT PAVING 0 � O z C-) PERVIOUS CONC. ogog8gog w CONC. PAVING L,J cn � GRAVEL SURFACE 0 LANDSCAPING J CONCRETE CURB m LO SPOT ELEVATIONS xx.xx xx.xx o N PARKING COUNT FOUND CASE MON FIRE HYDRANT Y f GAS METER 0 10-1 GUY WIRE ANCHOR JUNCTION BOX Cc ❑ z PARKING LOT LIGHT Q POWER POLE W/TRANSFORMER C Q- POWER VAULT W ROCKERY C SIGN T SIGNAL POLE STORM CATCHBASIN ■ ❑ STREET LIGHTUj CD _j TELEPHONE JUNCTION BOX ❑ 15 TELEPHONE VAULT OT OT = UNDERGROUND POWER UTILITY POLE f -0- a N o 0 0 UTILITY MANHOLE 0 ~ WATER METER ® O WATER VALVE XUj ­7 = 20' �11 �j ABBREVIATIONS 1. THIS DEVELOPMENT PROJECT SHALL CONFORM TO THE CITY OF 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PUBLIC SAFETY ON \, N . AUBURN'S REQUIREMENTS AND BE IN ACCORDANCE WITH THE AND AROUND THIS PROJECT. PRIOR TO THE START OF WORK, ALL PARKING DATA. BENCHMARKS: BLC - BUILDING CORNER APPROVED PLANS. ANY CHANGES FROM THE APPROVED PLAN WILL METHODS AND EQUIPMENT USED FOR TRAFFIC CONTROL AND -DATUM: PARKING REQUIRED: C - COMPACT REQUIRE APPROVAL FROM THE OWNER, ENGINEER AND THE CITY, STREET MAINTENANCE SHALL BE SUBMITTED TO THE CITY FOR NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88). SUPPORTIVE HOUSING = 13 SPACES BASE: CB - CATCH BASIN APPROVAL. CONTRACTORS AND THEIR SURETY SHALL BE LIABLE (1 SPACE PER 2 UNITS PLUS ONE CITY OF AUBURN BENCHMARK NO.15C. FOUND CL - CLASS 2. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE FOR INJURIES AND DAMAGES TO PERSONS AND PROPERTY CONSTRUCTION SEQUENCE FOR MANAGER'S UNIT AS ESTABLISHED RAILROAD SPIKE ON THE WEST FACE OF POWER CO - CLEAN OUT "WASHINGTON TATE DEPARTMENT OF TRANSPORTATION (WSDOT) SUFFERED BECAUSE OF CONTRACTORS OPERATIONS OR BY CITY IN PRE -APPLICATION MEETING POLE, AT THE SOUTHEAST QUADRANT OF AUBURN COA - CITY OF AUBURN STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL NEGLIGENCE CONNECTED WITH THEM. 1. ATTEND A PRE -CONSTRUCTION MEETING WITH THE CITY OF WAY NORTH AND 28TH STREET NE. D - STORM DRAIN CONSTRUCTION" (2002), EXCEPT WHERE SUPPLEMENTED OR AUBURN. UNDER ZONING ORDINANCE) ELEVATION: 57.15 FEET. DDCV - DOUBLE DETECTOR CHECK VALVE MODIFIED BY THE CITY'S CONSTRUCTION STANDARDS MANUAL. 7. ALL CONSTRUCTION SURVEYING FOR EXTENSIONS OF PUBLIC DI - DUCTILE IRON FACILITIES SHALL BE DONE UNDER THE DIRECTION OF A PARKING PROVIDED: SITE N0, 1: DS - DOWNSPOUT COPIES OF THE ABOVE DOCUMENTS SHALL BE AVAILABLE AT THE WASHINGTON LICENSED LAND SURVEYOR OR A WASHINGTON 2. ESTABLISH CLEARING AND GRADING LIMITS FOR THE SITE. ADA ACCESSIBLE: 1 (OK) JOB SITE DURING CONSTRUCTION. SET REBAR WITH CAP IN GRAVEL ON THE NORTH DTL - DETAIL LICENSED PROFESSIONAL CIVIL ENGINEER. STANDARD: 12 3. INSPECT AND REPLACE ANY OF THE EXISTING EROSION & SIDE OF 26TH STREET NE. +/-22' EAST OF D/W - DRIVEWAY COMPACT: 2 (13.3%) � EL - ELEVATION 3. A PRE -CONSTRUCTION MEETING SHALL REQUIRED PRIOR T - 0 E S L BE EQU ED 0 SEDIMENTATION CONTROL MEASURES THAT ARE NO LONGER WATER METER AND +/ 5.3 SOUTH OF NORTH 8. CERTIFIED DRAWINGS ARE REQUIRED PRIOR TO PROJECT TOTAL: 15 ESMT - EASEMENT THE START OF ALL CONSTRUCTION. CONTACT THE PUBLIC WORKS PERFORMING AS INTENDED TO PROTECT ADJACENT PROPERTIES GRADING QUANTITIES EDGE OF GRAVEL. ACCEPTANCE. REFER TO THE CITY S RECORD CONSTRUCTION PROJECT NOTES:ELEVATION: 58.30 FEET. EXG - EXISTING DEPARTMENT AT 253-931-3010 TO SCHEDULE A MEETING. AND OFF -SITE STORMWATER SYSTEMS FROM DOCUMENT HANDOUT. CONSTRUCTION -RELATED SEDIMENTATION PER CITY OF AUBURN FILL: 1,500 CY FD - FOUNDATION DRAIN 4. LOCATIONS SHOWN FOR EXISTING UTILITIES ARE APPROXIMATE. AND ALL OTHER APPLICABLE STANDARDS. PARCEL NUMBERS : 5125400355 SITE NO. 2: FDC - FIRE DEPTARTMENT CONNECTION THE CONTRACTOR IS CAUTIONED THAT OVERHEAD UTILITY LINES 9. ADDITIONAL PERMITS REQUIRED FROM THE CITY OF AUBURN: () EXCAVATION: 1,110 CY FF - FINISHED FLOOR ZONING: R4 MULTIPLE -FAMILY RESIDENTIAL TOP OF BRASS DISC INCASED AT THE MAY NOT BE SHOWN ON THE DRAWINGS. IT SHALL BE THE GRADING PERMIT, WATER PERMIT, FIRE LINE CONNECTION PERMIT, „ FHY - FIRE HYDRANT 4. DEMOLISH THE EXISTING BUILDING, PAVING, STORM LINES, WATER TOTAL AREA: 0.697 ACRES IMPORTED FILL: 1 „ 500 CY INTERSECTION OF 26TH STREET NE AND I CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE TRUE SEWER PERMIT, STORM PERMIT, BACKFLOW PERMIT. LINES, AND SEWER LINES, AS NOTED ON PLANS. AREA DISTURBED FOR CONSTRUCTION: 0.697 ACRES MATERIAL DISPOSED OF OFF -SITE: 1,110 CY STREET NE. FL - FLANGE JOINT ELEVATIONS AND LOCATIONS OF ALL UNDERGROUND UTILITIES AND 10. ANY HAULING OF MATERIAL WILL OCCUR BETWEEN 9AM AND 3PM. BUILDING CONSTRUCTION TYPE: VB, SPRINKLERED ELEVATION: 58.09 FEET. H/C - HANDICAP THE EXTENT OF ANY HAZARD CREATED BY OVERHEAD UTILITY 5. BEGIN FINAL SITE FINE GRADING OPERATIONS. THE CONTRACTOR IE - INVERT ELEVATION LINES. IDENTIFICATION, LOCATION MARKING AND RESPONSIBILITY BASIS 0 F BEARING: SHALL ENSURE THAT NO SILT -LADEN RUNOFF DISCHARGES TO LF - LINEAR FEET FOR, UNDERGROUND FACILITIES OR UTILITIES, IS GOVERNED BY THE ADJACENT PROPERTIES OR TO EXISTING STORMWATER SYSTEM. IMPERVIOUS SURFACE L/S - LANDSCAPING THE PROVISIONS OF CHAPTER 19.122 REVISED CODE OF TRUE NORTH. BASED UPON GLOBAL POSITIONING SYSTEM (GPS) LAMBERT MH - MANHOLE WASHINGTON (RCW). PRIOR TO STARTING CONSTRUCTION, THE GRID WASHINGTON STATE NORTH ZONE COORDINATES. A CONVERGENCE 6. AS CONSTRUCTION PROGRESSES, REVEGETATE ALL SLOPES AND COVERAGE. THE UTILITY CONFLICT NOTE: TBE RESPONSIBLE FOR VERIFYING THE LOCATION, RECORD DRAWING CERTIFICATION CONTRACTOR SHALL CALL ONE -CALL (1-800-424-5555) FOR ANGLE OF 01'01'55.23" COUNTERCLOCKWISE WAS APPLIED AT A PUNCH DISTURBED AREAS AS SPECIFIED BY THE "REQUIREMENTS FOR THESE DRAWINGS CONFORM TO THE UTILITY LOCATIONS (WATER, SANITARY SEWER, STORM SEWER, GAS, IN 2" BRASS DISC, INCASED, LOCATED AT THE INTERSECTION OF "I" EXPOSED SOIL STABILIZATION". EXISTING BUILDING: 3,042 SF DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES, WHETHER SHOWN ON TORS CONSTPJJCTION RECORDS. POWER, TELEPHONE AND TELEVISION). STREET NORTHEAST AND 26TH STREET NORTHEAST. EXISTING PAVEMENT TOTAL: 1,105 SF THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE 7. BEGIN CONSTRUCTION OF BUILDING, STORM, WATER, SEWER AND TOTAL: 4,147 SF THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. 5. PRIOR TO THE START OF CONSTRUCTION A PROPOSED ROUTE AND THE NORTH AMERICAN DATUM OF 1983/1991 (NAD 83/91) GRID UTILITIES. THIS SHALL INCLUDE CALLING UTILITY LOCATE ® 1-800-424-5555 AND e THEN POTHOLING ALL EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY rA114f SCHEDULE FOR HAULING MATERIAL TO THE SITE SHALL BE COORDINATES WERE FOUND TO BE 123549.929 1296680.313 AT THAT NEW BUILDINGS: 11,649 SF BY; DATE: / CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. SUBMITTED TO THE CITY FOR APPROVAL. IF THE CITY BELIEVES POINT. THE INVERSE OF BOTH THE SEA LEVEL CORRECTION FACTOR OF 8, BEGIN ASPHALT, PERVIOUS CONCRETE, CURB, AND LANDSCAPE NEW PAVEMENT, WALKS: 7,117 SF LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT TITLE/POSITION: �I���I�/�E THAT THE PROPOSED HAUL ROUTE WILL ADVERSELY IMPACT THE 1.000000751 AND THE GRID SCALE FACTOR OF 1.000035993 WAS INSTALLATION. TOTAL: 18,766 SF GUARANTEED AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD STREET NETWORK, HAULING MAY BE LIMITED TO APPROPRIATE APPLIED TO THE GRID COORDINATES FOR SHOWN GROUND DISTANCES. OCCUR, THE CONTRACTOR SHALL CONSULT RUPERT ENGINEERING, INC. •/� /v OFF-PEAK HOURS OR ALTERNATE ROUTES. 9. REMOVE TESC MEASURES UPON FINAL STABILIZATION AND NET CHANGE: +14,619 SF TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. CONFIRMED BY CITY.- DATE: APPROVAL FROM THE CITY INSPECTOR. \\STORAGE\Data\2008\08105\Civil\C1-105.dwg I Drafter Name: A. PAUL Plot Date: JUL 30 2009 10:33:27 1 Last Modified Date: JUL 30 2009 10:27:11 1 Submittal: REVISION 4 W W N Z W W W O 0 a MJ - MECHANICAL JOINT N o o OH - OVERHEAD o Z it PL - PROPERTY LINE Uj R - RADIUS o REF - REFERENCE DRAWING R/W - RIGHT-OF-WAY w S - SANITARY SEWER SQ FT - SQUARE FEET STD - STANDARD S/W - SIDEWALK T - TELEPHONE TC - TOP OF CURB a r N TP - TEST PIT TV - TELEVISION M E • p U.N.O - UNLESS NOTED PO �E WAsy46, OTHERWISE YL - YARD LIGHT S - SOUTH W - WEST E - EAST ,p 43211 N - NORTH TE��`' NW - NORTHWEST s/pNAL E SW - SOUTHWEST NE - NORTHEAST SE - SOUTHEAST DATE 9/11 /08 PROJECT REF: FAC08-0024 DRAWN KWT THESE PLANS ARE APPROVED FOR CONFORMANCE WITH THE CITY OF AUBURN'S CHECKED AEP ENGINEERING DIVISION REQUIREMENTS APPROVED BY: Joe No. 08105 SHEET N0. DATE APPROVED: -7' ,3v/0 c 1 SHEET 1 OF 7 10 D 20 eo 1. .I.t N8947 05"E 779. 0 - - =- FOUND 2" BRASS DISC j• WITH PUNCH INCASED AT I . THE INTERSECTION OF "I" STREET NE & 26TH STREET NE SITE o BENCHMARK NO.2 ���1. g . e . . . . . ELEVATION 58.09 FEET- . . 5�1� 30'. a GRAYED ITEMS ON THIS SHEET WILL . BE DEMOLISHEDAND ARE SHOWN FOR REFERENCE ONLY 58 LF 8"0 CL � 0�b 52 DIP ® 0.55% 5$' •i EXG STORM DRAINAGE MANHOLE` M ,w RIM 58.24 30" CONC NNW 52.79 IE ' 30" CONC S 52.69 IE 8" PVC E 53.82 IE 8" CONC W (COULD NOT MEASUR ) EXG CATCH BASIN #G118 STANDARD GRATE I' RIM 57.72' 8" CONC E 55.51 IE SANITARY SEWER MANHOLE (CITY #409-37) RIM 57.89 8" CONC S 55.12 IE 8" CONC CHANNEL ON THE NORTH SIDE OF STRUCTURE 55.16 GUY WIRE ANCHOR T SAWCUT AND REMOVE EXG ASPHALT FOR�`�� INSTALLATION OF NEW WATER CONNECTION -0- � POWER POLE W/TRANSFORMER & UNDERGROUND POWER REMOVE EXG S/W AND CURB TO NEAREST JOINT FOR INSTALLATION OF NEW D/W APPROACH, EXG 6"0 SEWER STUB (REF). POINT OF CONNECTION TO EXG HOUSE UNKNOWN. REMOVE EXG WATER METER - AND SERVICE LINE. CAP AT EXG WATER MAIN. SAWCUT AND REMOVE EXG ASPHALT FOR DEMOLITION OF EXG WATER SERVICE LINE. REMOVE EXG S/W, D/W APPROACH, AND CURB TO NEAREST JOINT IN S/W. i 30' j CL xD L CD 51 UN5,b6 ���``'�� S0� rr.w wn c�9• „' G?° V ; % UI .. 2CCtt H' ST NE 7. --::(1 RESID r'IfENTIAL) ', o' 2, 0100. HP o-777 `'23Q:00 a �o .. ' _ His 1 _' .; 8� POWER POLE W/TRANSFOR S89'47 21'W 5%� FENCE ,� �• ��� =t, pT TEL - TEL ND- POW82 22.07 3 WOOD FE `' 89'47 05 E 207.93 5 - - - ° - - - • N e.._ a �ti o /' 1 a I 10 g� °.. -T WI C • OR'F. 51°' S1. �5 6 C ONE FENCE / p o 5 Q rr N n w p M ��� .� c�`1 8° 52" 5 �4 \ 18" FIR 14 FIR�,1� 19 �� �• 86 1 JJ / �z "6. • ' :'' ' : • `' ti1 28 FIR ^� 5 TWINS TWIN _ ..:: .. o 16 FRUIT TREE \ J��0. \ \ \ 5�8�5 x d: 'Nit AI � . \\\BEIVCH \\\\ \\y j ° a• ��.� 29 5 a1 \`\ \ 27" �\ ��� o 1� 6' CYCLONE FENCE _ �D I 11 \\\I\�\\ EXG TEMPORARY S\ 400 38" FRUIT TREE QUAD 25 �. ' " xw 5 ' 0�6 4� \V _...,..,...�. w WATER � S ELEVATIONC � \ :' • � 0 51 `° r,. \\\ \\\ \\� DECt L2l IN �:'0 E�1Q 1�F) �\\\ a NOTU- ,;�NWI I �150 �� p1 •_ �o C. 1 "6. ��. 5�. DEMOLITIOl THIS PARCEL I 51• 36 CLUSTF 23 IE=5$. F 50R� COMPLETED BY OTHERS P g POWER CABINEI UNDER A SEPARATE PERMIT 3:1 cz� �GR D R �a�=56.62 �310 3a. \\ \\\ 3:1 I =57.33 a Ix ti � .. y EXG , CATCH.:BASI �\\c�'r��L� \\ 5 I STANDARD .GRATE..-. RIM 7:68 ��At- a, • 8'' S�. �38" DECIDUOUS N89'50'16"E 230.00' G\IF \�. / r - - - - - - - - - -----, �.i 42 2 z r J TEMP CONVEYANCE PIPES TO I \THIS AREA IS TO BE SET ASIDE FOR A FUTURE STOR ER INFILTRATION 0 BE REMOVED WHEN TEMP I FACILITY. NO HEAVY CONSUCTION TRAFFIC SHOULD BE ALLOWED IN ORDER Q e1 ( POND IS FILLED IN, I TO PREVENT ADVERSE COMPACTION OF THE EXISTING SOILS. THIS I x N (\ 5 I r. I NO -DISTURBANCE AREA SHALL BE IDENTIFIED DURING THE CONSTRUCTION STAGE WITH EITHER A TEMPORARY FIVE-FOOT CHAIN LINK FENCE OR ORANGE -COLORED CONSTRUCTION FENCING. I -T� I ti nr� i 5942/�I I� .5142 REMOVE EXG SEWER �STUB AND CAP AT f �o MAIN. . �6� �5�•.,; 5�ti1 CONTRACTOR TO MAINTAIN AND MODIFY ( 10' WATERLINE q EXG DITCHES, AS NECESSARY, TO 0 EASEMENT ENSURE THAT ALL RUNOFF FROM THE ( REC. N0. 3832556 09�1 �o�ti• �� SITE IS DIRECTED TO THE TEMPORARY SEDIMENT TRAP.2 1 0 �\ \ 57./"�/�- ... ... war- ... ..._Fr�� ... D, IK 53 � 58.86 SW5016 230.00 "WOOD , FEN'CEX z o.. N \-- 59.06 �' :04 9 58.53 . . �� � h�\ w $• 59' 58.r i g0��5a9� _ oti 58.9 k._ 1 s . f$ c \ . . is . . . . . . . . . I . f`. �. TESC & DEMOLITION PLAN Jd\ 1 = 20 NOTES: CONTRACTOR SHALL ENSURE THAT ALL STORMWATER FROM THE SITE IS DIRECTED TO THE TEMPORARY STORM POND BEFORE BEING DISCHARGED TO PUBLIC CONVEYANCE SYSTEM. UTILITY CONFLICT NOTE: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES, WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE ® 1-800-424-5555 AND THEN POTHOLING ALL EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT RUPERT ENGINEERING, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. REQUIREMENTS FOR EXPOSED SOIL STABILIZATION STABILIZATION METHOD: HYDROSEEDING & MULCHING: A. TIME OF PLANTING - DURING THEPERIOD T I 1 TIME E OD BETWEEN APRL THROUGH JUNE 30 AND SEPTEMBER 1 THROUGH OCTOBER 31. (NOTE: IF PLANTING BETWEEN JULY 1 AND AUGUST 31, IRRIGA11ON MAY BE REQUIRED, IF PLANTING BETWEEN NOVEMBER 1 AND MARCH 31, MULCHING WILL BE REQUIRED IMMEDIATELY AFTER PLANTING.) B. SEEDBED PREPARATION - THE SEEDBED SHOULD BE FIRM, BUT NOT COMPACT, WITH A FAIRLY FINE SURFACE FOLLOWING SURFACE ROUGHENING. SURFACE ROUGHENING SHOULD BE DONE AT RIGHT ANGLES TO THE SLOPE AND PREFERABLE "CAT WALKED" UP SLOPE. C. FERTILIZATION - AS PER SUPPLIER'S RECOMMENDATIONS. DEVELOPMENTS ADJACENT TO WATER BODIES AND WETLANDS MUST USE NON -PHOSPHOROUS FERTILIZER. D. SEEDING - APPLY THE FOLLOWING MIXTURE TO THE PREPARED SEED BED AT A RATE OF 5 LBS/1,000 SF: KIND AND VARIETY OF PERCENT BY MINIMUM PERCENT MINIMUM PERCENT SEED IN MIXTURE WEIGHT PURE SEED GERMINATION COLONIAL BENTGRASS ' (HIGHLAND OR ASTORIA) 10% 9.8% 85% RED FESCUE (ILLAHEE, RAINIER, OR PENNLAWN) 40% 39,20% 90% ENGLISH PERENNIAL RYE 30% 29.40% 90% WHITE DUTCH CLOVER (PRE -INOCULATE) 20% 19.60% 90% WEED SEED (MAX %) .50% INERT AND OTHER CROPS (MIN %) 1.50% TOTAL 100% E. "HYDROSEEDING" APPLICATIONS WITH APPROVED SEED -MULCH -FERTILIZER MIXTURES MAY ALSO BE USED. F. MAINTENANCE - SEEDING SHOULD BE SUPPLIED WITH ADEQUATE MOISTURE. SUPPLY WATER AS NEEDED, ESPECIALLY IN ABNORMALLY HOT OR DRY WEATHER, OR ON ADVERSE SITES. WATER APPLICATION RATES SHOULD BE CONTROLLED TO PREVENT RUNOFF. INADEQUATE AMOUNTS OF WATER MAY BE MORE HARMFUL THAN NO WATER. GRADING &EROSION CONTROL NOTES 1, WITHIN THE CITY OF AUBURN, ALL REQUIRED SEDIMENTATION AND EROSION CONTROL FACILITIES INDICATED ON THE PLANS MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING Al OTHER CONSTRUCTION ACTIVITIES. THESE FACILITIES SHALL BE MAINTAINED, AND UPGRADED IF NECESSARY, TO ENSURE THAT SEDIMENT -LADEN WATER AND STORM DRAINAGE RUNOFF DOES NOT IMPACT THE ADJACENT PROPERTIES, NATURAL DRAINAGE WAYS, OR THE EXISTING CITY STORM DRAINAGE SYSTEM. 2. THE SOURCES FOR ALL MATERIAL IMPORTED TO THE SITE SHALL BE APPROVED BY THE CITY 3. THE STORM DRAINAGE DETENTION (RETENTION IF INFILTRATION SYSTEM IS USED) SEDIMENTATION AND EROSION CONTROL FACILITIES DEPICTED ON THE APPROVED DRAWINGS ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. ADDITIONAL DRAINAGE AND EROSION CONTROL FACILITIES MAY BE REQUIRED AS SITUATIONS WARRANT DURING CONSTRUCTION. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT AND ADDITIONS TO THESE CONTROL SYSTEMS SHALL BE THE RESPONSIBILITY OF THE PERMITTEE. 4. THE TEMPORARY EROSION CONTROL FACILITIES, INCLUDING ALL PERIMETER CONTROLS AND THE DETENTION (RETENTION IF INFILTRATION SYSTEM IS USED) CONTROL PONDS, SHALL REMAIN IN PLACE UNTIL FINAL SITE CONSTRUCTION IS COMPLETED. AFTER CITY APPROVAL, THE CONTRACTOR WILL BE RESPONSIBLE FOR REMOVING ALL TEMPORARY FACILITIES. 5. THE CONTRACTOR WILL BE REQUIRED TO WATER THE SITE, AS NECESSARY, TO REDUCE DUST EMISSIONS AS A RESULT OF CONSTRUCTION ACTIVITY. THE CONTRACTOR SHALL ALSO SWEEP ALL AFFECTED PUBLIC ROADS, AS NECESSARY, TO REMOVE MATERIAL DEPOSITED AS A RESULT OF PROJECT CONSTRUCTION ACTIVITY. 6. ALL AREAS OF ACTIVE EARTHWORK WHICH HAVE THE POTENTIAL FOR EROSION AND SEDIMENTATION IMPACTS ON ADJACENT PROPERTIES, NATURAL DRAINAGE WAYS, OR THE EXISTING CITY STORM DRAINAGE SYSTEM MUST BE STABILIZED ACCORDING TO THE FOLLOWING SCHEDULE: FROM APRIL 1 TO SEPTEMBER 30, AREAS AT FINAL GRADE AND THOSE THAT ARE SCHEDULED TO REMAIN UNWORKED FOR MORE THAN THIRTY DAYS SHALL BE STABILIZED WITHIN TEN DAYS. FROM OCTOBER 1 TO MARCH 31, EARTHWORK ACTIVITIES SHALL BE CONDUCTED IN STAGES IN ORDER TO MINIMIZE SOIL EXPOSURE. EXPOSED SOILS WITH AN AREA GREATER THAN 5,000 SQUARE FEET THAT ARE SCHEDULED TO REMAIN UNWORKED FOR MORE THAN 24 HOURS AND EXPOSED AREAS OF LESS THAN 5,000 SQUARE FEET THAT WILL REMAIN UNWORKED FOR MORE THAN SEVEN DAYS SHALL BE STABILIZED IMMEDIATELY. RECORD DRAWING CERTIFICATION THESE DRAWINGS CONFORM TO THE TOR'S CONSTRUCTION RECORDS. BY; DATE: TITLE/POSffION: trAll Ef%L- CONFIRMED BY CITY: DJ1TE: PROJECT REF: FAC08-0024 PS S Z7/Z0o 9 THESE PLANS ARE APPROVED FOR CONFORMANCE WITH THE CITY OF AUBURN'S ENGINEERING DIVISION REQUIREMENTS APPROVED BY: _L A DATE APPROVED: v;X 0 Q o � U a � V) O Q d J > 00 U i � N 00 V 0) .n w w `n n n n Z � w Z w T 3 L Z iv o co Z O ` N j U raw C Z z � Q m Z c� Q Q Z_ I N LAJ j U � O z CL w LJ LJ.J Q J o U-) N z O O M Z W C J 8d i w Lj -J F_ w w o p N 0 Z w LLj o N Z w oa O N it U U z U o Z CJ b b o M M a a a c o Z U d C U � N Cl C_5 Z 2 C •.J j- N ll E. p of WASH 1 F�432 ,C�AST SFONA L iti DATE 09.11.08 DRAWN KWT CHECKED AEP JOB NO. 08105 SHEET NO. C2 \\STORAGE\Data\2008\08105\Civil\C2-105.dwg I Drafter Name: A. PAUL I Plot Date: AUG 27 2009 08:20:00 1 Last Modified Date: AUG 21 2009 14:18:15 1 Submittal: REVISION 5 SHEET 2 OF 7 to )2016 N89'47'05"E 779 0' FOUND 2" BRASS DISC'.'.'.'.'. L WITH PUNCH, INCASED, .AT . . . • . . . . . THE INTERSECTION OF T' 5$ . . . . . . . . . . . . .. °� � STREET NE & 26TH . . . . . . . . . . . . . STREET NE SITE _T BENCHMARK NO.2 . . ELEVATION 58.09 FEET 5��. . . . . �k . . -30 �.......... 13 LF EXG 8" 0 PVC°°.5° SDR-21 @ 0.5% 5�: EXG STORM DRAINAGE MANHOLE . . .t` RIM 58.24 ;z. . . . 30" CONC NNW 52.79 IE� 30" CONC S 52.69 IE . . . 8" PVC E 53.82 IE ' 8" CONC W (COULD NOT MEASUR ) ❑ 1 EXG CATCH BASIN #G118 STANDARD GRATE I. RIM 57.72 8" CONC E 55.51 IE I. SANITARY SEWER MANHOLE --- (CITY #409-37) RIM 57.89 8" CONC S 55.12 IE 8" CONC CHANNEL ON THE NORT C B # 1 SIDE OF STRUCTURE 55.16 YARD DRAIN PER DTL 2/G2 RIM = 58.5 IE = 55.41 GUY WIRE ANCHOR SAWCUT AND REMOVE IE=58.00- EXG ASPHALT FOR INSTALLATION OF NEW WATER CONNECTION ��- POWER POLE W/TRANSFORMER & UNDERGROUND POWER REMOVE EXG S/W AND CURB TO NEAREST JOINT FOR INSTALLATION OF NEW D/W APPROACH. EXG 6" 0 SEWER STUB (REF). POINT OF CONNECTION TO EXG HOUSE UNKNOWN. REMOVE EXG WATER METER - AND SERVICE LINE. CAP AT EXG WATER MAIN. SAWCUT AND REMOVE EXG ASPHALT FOR DEMOLITION OF EXG WATER SERVICE LINE. REMOVE EXG S/W, D/W APPROACH, AND CURB TO NEAREST JOINT IN S/W. 3:1 �� �• �� 9.0 / zi 00 ck� . . rn. • i. . 1 Of ; \\\ I YARD DRAIN AND TEMP - - 1�b' all\ THIS AREA IS TO BE SET ASIDE FOR A FUTURE STORMWATER INFILTRATION , CONVEYANCE PIPES TO BE I I •,u FACILITY. NO HEAVY CONSUCTION TRAFFIC SHOULD BE ALLOWED IN ORDER REMOVED WHEN TEMP POND IS FILLED IN. I TO PREVENT ADVERSE COMPACTION OF THE EXISTING SOILS. THIS M `y NO -DISTURBANCE AREA SHALL BE IDENTIFIED DURING THE CONSTRUCTION � � EXG TEMPORARY SEDIMENT STAGE WITH EITHER A TEMPORARY FIVE-FOOT CHAIN LINK FENCE OR 1 I� ORANGE -COLORED CONSTRUCTION FENCING. :1 TRAP. MAX WATER I SURFACE ELEVATION ® rn 58.0'. (1,320 SF) I I g-1 %TI DOWN -TURNED ELBOW UTLET FROWF'OND. 6 • 6PENING OF ELBOW MUST BE 37 LF EXG 8» 1 AT LEAST 1 FOOT BELOW THE CL 52 D�V 7%,' OUTLET INVERT ELEVATION. I q,6 1 /59.42 \ 1 =58.00 L - - - - - -\ 58.75 59.0 REMOVE EXG SEWER u,III g 6 STUB AND CAP AT �. MAIN. .I.. '� °� 5�., 1 9�1 CONTRACTOR TO MAINTAIN AND MODIFY I 10' WATERLINE 59 5g 5°� ' EXG DITCHES, AS NECESSARY, TO 0 EASEMENT ENSURE THAT ALL RUNOFF FROM THE REC. N0. 3832556 / ti� �g. SITE IS DIRECTED TO THE TEMPORARY ° �° 5° �� SEDIMENT TRAP. 5 30' 7. 0011,X. . I �� / F•! _a■■L� A•L - `. �! . a••a •..•x,�F! L-•�� �F .I� ..�. �g2 6 CYCLONExFENCE 5�� S89'50'16 �.00' X 5 � b WOOD FENCE z c 919; c�8•. �� °� w 66 5. i. 5°. 0". .. w "o : e 58.53 �g � I w L... I . Y I41 I. 5g.06 "' 58.67 5 5 g05�5�46 •e TESC & DEMOLITION PLAN, NOTES: CONTRACTOR SHALL ENSURE THAT ALL STORMWATER FROM THE SITE IS DIRECTED TO THE TEMPORARY STORM POND BEFORE BEING DISCHARGED TO PUBLIC CONVEYANCE SYSTEM. REQUIREMENTS FOR EXPOSED SOIL STABILIZATION STABILIZATION METHOD: HYDROSEEDING & MULCHING: A. TIME OF PLANTING - DURING THE TIME PERIOD BETWEEN APRIL 1 THROUGH JUNE 30 AND SEPTEMBER 1 THROUGH OCTOBER 31. (NOTE: IF PLANTING BETWEEN JULY 1 AND AUGUST 31, IRRIGATION MAY BE REQUIRED. IF PLANTING BETWEEN NOVEMBER 1 AND MARCH 31, MULCHING WILL BE REQUIRED IMMEDIATELY AFTER PLANTING.) B. SEEDBED PREPARATION - THE SEEDBED SHOULD BE FIRM, BUT NOT COMPACT, WITH A FAIRLY FINE SURFACE FOLLOWING SURFACE ROUGHENING. SURFACE ROUGHENING SHOULD BE DONE AT RIGHT ANGLES TO THE SLOPE AND PREFERABLE "CAT WALKED" UP SLOPE. C. FERTILIZATION - AS PER SUPPLIER'S RECOMMENDATIONS. DEVELOPMENTS ADJACENT TO WATER BODIES AND WETLANDS MUST USE NON -PHOSPHOROUS FERTILIZER. D. SEEDING - APPLY THE FOLLOWING MIXTURE TO THE PREPARED SEED BED AT A RATE OF 5 LBS/1,000 SF: KIND AND VARIETY OF PERCENT BY MINIMUM PERCENT MINIMUM PERCENT SEED IN MIXTURE WEIGHT PURE SEED GERMINATION COLONIAL BENTGRASS (HIGHLAND OR ASTORIA) 10% 9.8% 85% RED FESCUE (ILLAHEE, RAINIER, OR PENNLAWN) 40% 39.20% 90% ENGLISH PERENNIAL RYE 30% 29.40% 90% WHITE DUTCH CLOVER (PRE -INOCULATE) 20% 19.60% 90% WEED SEED (MAX %) .50% INERT AND OTHER CROPS (MIN %) 1.50% TOTAL 100% E. "HYDROSEEDING" APPLICATIONS WITH APPROVED SEED -MULCH -FERTILIZER MIXTURES MAY ALSO BE USED. F. MAINTENANCE SEEDING SHOULD BE SUPPLIED WITH ADEQUATE MOISTURE. SUPPLY WATER AS NEEDED, ESPECIALLY IN ABNORMALLY HOT OR DRY WEATHER, OR ON ADVERSE SITES. WATER APPLICATION RATES SHOULD BE CONTROLLED TO PREVENT RUNOFF. INADEQUATE AMOUNTS OF WATER MAY BE MORE HARMFUL THAN NO WATER. GRADING & EROSION CONTROL NOTES 1. WITHIN THE CITY OF AUBURN, ALL REQUIRED SEDIMENTATION AND EROSION CONTROL FACILITIES INDICATED ON THE PLANS MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR OTHER CONSTRUCTION ACTIVITIES. THESE FACILITIES SHALL BE MAINTAINED, AND UPGRADED IF NECESSARY, TO ENSURE THAT SEDIMENT -LADEN WATER AND STORM DRAINAGE RUNOFF DOES NOT IMPACT THE ADJACENT PROPERTIES, NATURAL DRAINAGE WAYS, OR THE EXISTING CITY STORM DRAINAGE SYSTEM. 2. THE SOURCES FOR ALL MATERIAL IMPORTED TO THE SITE SHALL BE APPROVED BY THE CITY. 3. THE STORM DRAINAGE DETENTION (RETENTION IF INFILTRATION SYSTEM IS USED) SEDIMENTATION AND EROSION CONTROL FACILITIES DEPICTED ON THE APPROVED DRAWINGS ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. ADDITIONAL DRAINAGE AND EROSION CONTROL FACILITIES MAY BE REQUIRED AS SITUATIONS WARRANT DURING CONSTRUCTION. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT AND ADDITIONS TO THESE CONTROL SYSTEMS SHALL BE THE RESPONSIBILITY OF THE PERMITTEE. 4. THE TEMPORARY EROSION CONTROL FACILITIES, INCLUDING ALL PERIMETER CONTROLS AND THE DETENTION (RETENTION IF INFILTRATION SYSTEM IS USED) CONTROL PONDS, SHALL REMAIN IN PLACE UNTIL FINAL SITE CONSTRUCTION IS COMPLETED. AFTER CITY APPROVAL, THE CONTRACTOR WILL BE RESPONSIBLE FOR REMOVING ALL TEMPORARY FACILITIES. 5. THE CONTRACTOR WILL BE REQUIRED TO WATER THE SITE, AS NECESSARY, TO REDUCE DUST EMISSIONS AS A RESULT OF CONSTRUCTION ACTIVITY. THE CONTRACTOR SHALL ALSO SWEEP ALL AFFECTED PUBLIC ROADS, AS NECESSARY, TO REMOVE MATERIAL DEPOSITED AS A RESULT OF PROJECT CONSTRUCTION ACTIVITY. 6. ALL AREAS OF ACTIVE EARTHWORK WHICH HAVE THE POTENTIAL FOR EROSION AND SEDIMENTATION IMPACTS ON ADJACENT PROPERTIES, NATURAL DRAINAGE WAYS, OR THE EXISTING CITY STORM DRAINAGE SYSTEM MUST BE STABILIZED ACCORDING TO THE FOLLOWING SCHEDULE: FROM APRIL 1 TO SEPTEMBER 30, AREAS AT FINAL GRADE AND THOSE THAT ARE SCHEDULED TO REMAIN UNWORKED FOR MORE THAN THIRTY DAYS SHALL BE STABILIZED WITHIN TEN DAYS. FROM OCTOBER 1 TO MARCH 31, EARTHWORK ACTIVITIES SHALL BE CONDUCTED IN STAGES IN ORDER TO MINIMIZE SOIL EXPOSURE. EXPOSED SOILS WITH AN AREA GREATER THAN 5,000 SQUARE FEET THAT ARE SCHEDULED TO REMAIN UNWORKED FOR MORE THAN 24 HOURS AND EXPOSED AREAS OF LESS THAN 5,000 SQUARE FEET THAT WILL REMAIN UNWORKED FOR MORE THAN SEVEN DAYS SHALL BE STABILIZED IMMEDIATELY. UTILITY CONFLICT NOTE: RECORD DRAWING CERTIFICATION THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, THESE DRAWINGS CONFORM TO THE DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES, WHETHER SHOWN ON CON ST CTION RECORDS. THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-5555 AND THEN POTHOLING ALL EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY BY; DATE: CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT TITLE/POSITION: E'�Y�I"C f GUARANTEED AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT RUPERT ENGINEERING, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. CONFIRMED BY CITY: DATE: PROJECT REF: FAC08-0024 i g 7-30 -Zwq THESE PLANS ARE APPROVED FOR CONFORMANCE WITH THE CITY OF AUBURN'S ENGINEERING DIVISION REQUIREMENTS APPROVED BY: , srai� - DATE APPROVED: 130 I a01 0 � Q F_ o U ca 0 0o r7 Z lJ > � U N _ i 'n W W "� "' Z � Z W 3 t C9 = r- Z o ,- � F= 1 °O 00 �� a� 3 rn Z 3 Lp ` N O �aLJ U Z Z � m Z Q .Q _Z � N c ,^ V / _ Lj_j F- j V � O :7 �- w LJ W to I— ^ J mo J 0 N z O F_ _ I 0 M z W 0 J r 86 lr�l J L,J F_ w U) W W ZO w Ln Z O W LLj z O N 0 U U U Of p Cj LLJ U C ZE d CJ Z_ C9 E. Pq! P� of WASyi G �FG/ STEM 21ONAL Et DATE 09.11.08 DRAWN KWT CHECKED AEP JOB NO. 08105 SHEET NO. C 2 SHEET 2 OF 7 \\STORAGE\Data\2008\08105\Civil\C2-105.dwg I Drafter Name: A. PAUL I Plot Date: JUL 30 2009 11:03:51 1 Last Modified Date: JUL 30 2009 10:27:01 1 Submittal: REVISION 4 10 AOZ016 s Slop N89'47'05"E 779. 0'- =�- - �. FOUND 2" BRASS DISC WITH PUNCH, INCASED, .AT. S £Ar$ Lit THE INTERSECTION OF "I„ STREET NE & 26TH 5g.. I �_ STREET NE SITE I. . o.. ��.. �° BENCHMARK NO.2 °��1. ti6 . . . . . 1 .IQo o Via: 5 SIGN ELEVATION 58.09 FEET S89.47'21 "W o� 22.07 S 3 WOOD ONCE 30 , a � Q 5" • �` o O i 29 8„ 52„ 6 1 „ 03 n�/o�,.,�Dc 505• TWINTWIN 58.33 a $5 �� 20„ EXG STORM DRAINAGE MANHOLE TMN RIM 58.24 �� ._.._5� a` 30" CONC NNW 52.79 IE DEC 30" CONC S 52.69 IE 36 CLUSTER­ 8" PVC E 53.82 IE �8" CONC 23" W (COULD NOT MEASUR) 1 -- `� _ - r _n 5°�� AMATEUR RADIO ANTENNA EXG CATCH BASIN STANDARD GRATE4 6� o-GROUND ROD RIM 57.72 ��NN „_.-- �. 153 LF FIRE *1 8 CONC E 55.51 IE C SANITARY SEWER MANHOLE �° $ 5�� 5��� 58° I EXG CATCH BASIN' SPRINKLER SUPPLY (CITY #409-37) `'' a STANDARD GRATE LINE (SIZE PER RIM 57.89 J I RIM 7.68 5 ..SPRINKLER DESIGN 8 CONC S 55.12 IE I. W . N j �.. 8 _ 8" CONC CHANNEL ON THE NORTH;;'� �' Z q a W W SIDE OF STRUCTURE 55.16 - �� ~ AP 28 LF OF E' Z SS SADDLE z " oL :0 58.45 F1T-vt1V� ! _ I R�Yc ApoN► sh PERFO AT ED IPE (IE 5 GUY WIRE ANCHOR �` ! `� 58.60 �`'R �� EXTENT OF 4,284 F I INFI TRATIO BED V1157 e ��� PER DTL 1 /C4 jj 1.3% 5$. I s>r coDoti y s i 7'E , -0- I . I. I 5 I� m 58.70 owE Try a �SMfSGREAGDE POWER POLE W/TRANSFORMER J °' 5�6� 5$1� 5� 58.J51 P BREAK & UNDERGROUND POWER o 5°5g w° I 58.70'-�. 11' 5 c CAP 26 LF F'1 ` ` yPE FORAT D:, PIPE (IE: 5 5 58.6 58. 5 58.45 EXG 6"0 SEWER STUB (REF). POINT OF CONNECTION TO EXG HOUSE UNKNOWN. ° 58.95 C OUT INSTALL NEW 1" TAP & NEW 1"0 IRRIGATION\ METER PER COA STD DTL WATER-13 AND IN -LINE IRRIGATION BACKFLOW PREVENTION ASSEMBLY SIM TO COA WATER-06. ADDITIONAL DETAIL PROVIDEQ.,ON IRRIGATION PLANS. INSTALL NEW ' TAP AND 1 j" O WATER METER PER COA STD DTL WATER-14� �`� INSTALL RPBA ON DOMESTIC RISERS . . . 59.55 FOR BACKFLOW PREVENTION. MATCH EXG GRADE EXG 8"0 WATER 59.30 MAIN (REF) 30' DITCH NEW SEWER MANHOLE (#409-067). INSTALL OVER 1 l IE=58.80 EXG MAIN AND GROUT AROUND CONNECTION. MATCH RIM TO EXG PAVEMENT ELEVATION. (IE=544!) SSCO SIM TO COA ' STD DTL SEWER-02 \` ° a ti5 �.. . Of I. i.,'•�ir��c. ,ram F.. � �l y. ■ I MW ii�r :-�� "•r; I � � 1 ` 'MLCEK W1 D �v i D' c,m __ GRADE 1 INSTALL CONC CASING ALONG BREAK WATER LINES PR DTL 9/C4 c I c 1,SSSCC_O4SIM TO COA STD DTL SEWER-02 59.65 (IE=54.96') 1" CLEANOUT SIM TO C STD DTL SEWER-02 %' v1 I. �� Po w E R PeL C Ex sT, . - FIRE SPRINKLER NOTES _ 26TH, ST NE T SPRINKLER SYSTEMS SHALL MEET COA STANDARD 7.01.5.2 AND �lE� • ow �- - RESIDENTIAL) THE FOLLOWING REQUIREMENTS: CEP IT' ot�A� 1 ..�.,,zdttG �4 4 o T L __ 2. us 2.60!00 `--- 1. PROPOSED FIRE LINE TO BE SIZED BY A FIRE PROTECTION OHP 5�5 . ENGINEER. 230.00' 2. BACKFLOW PROTECTION IS REQUIRED ON FIRE SPRINKLER a LINES. 3 E - I�__. --��5� A SEPARATE DETAILED PLAN OF THE UNDERGROUND FIR 5�e T -TEL - - - TEL POWER POLE W SFOR SPRINKLER SUPPLY LINE SHALL BE APPROVED BY THE N 47 �5"E 20 „93'-��� -- Prr = _. � : , . -.-:.. �..- GROUND- POWER FIRE MARSHAL AND INSTALLED BY A WASHINGTON STATE . WIRE ANCHOR :.. „ 10 -� CERTIFIED LEVEL U CONTRACTOR IN ACCORDANCE WITH 6 C ONE FENCE WAC 212-80-010. �... 5� T18°' FIR 14» FIR �,�� „ o 19" 4, A POST INDICATOR VALVE SHALL BE INSTALLED ON THE 28FIR o FIRE SPRINKLER SUPPLY LINE TO ISOLATE THE SYSTEM LL LO a ° 16" FRUIT TREE REQUIRED FOR I o __ ,.-, FROM THE CITY'S WATER SYSTEM WHEN R Q H EU X.._ REPAIR. 5. BLOCKING, PIPING AND RODDING DETAILS SHALL BE 29» I 5� °�6 PROVIDED WITHIN THE SUBMITTAL. „ 27 I 0 �w ~8= --' 6. APPROVAL OF THE CIVIL PLANS DOES NOT APPROVE THE °� I ��- ~' 6' CYCLONE FENCE INSTALLATION OF THE SPRINKLER SYSTEM SUPPLY PIPING. EA SEen EN „ 38 FRUIT TREE QUAD 25od " x� IN35" DECIDUOUSc�� Jg 5� I65 ' � 5 �o WATER CONSTRUCTION NOTES: TWIN � 5�� 1. ALL CONCRETE BLOCKING TO BE CONSTRUCTED PER COA STD DTL 6 LF 6 ADS POWER CABINET I CIDWATER-01. N-12 ® 15% 5i� 2. AFIRE SPRINKLER LINE REQUIRES A SEPARATE DETAILED PLAN AND -&TILF_ �sg I -TJLPCO-CF0IZ i�Ee- I �5' APPROVAL BY THE FIRE MARSHAL. CONTACT FIRE DEPARTMENT FOR o� x INSTALL NEW 5 w REQUIREMENTS. FAUCET SEGMENTAL WALL. (TYP) I z YARD GRAIN INSTALL & SECURE Ya" INSTALL 90' DI BEND (MJXMJ) W/CONC Ix -NOTES: ��. ALUMINUM OR STAINLESS BLOCKING (SIZE PER SPRINKLER DESIGN) N z PER DTL 1 C3 I STEEL SCREEN OVER 11 LF FIRE SPRINKLER SUPPLY DITCH „ IE-58.80 1. ALL DOWNSPOUT TIGHTLINES ARE TO BE 6 MINIMUM, HAVE A SLOPE RIM = 59.3 i OF 6"0 PIPE LINE, (SIZE PER SPRINKLER DESIGN) I OF AT LEAST 1%, AND BE CONSTRUCTED OF SOLID WALL PVC PIPE. 57.10 N8 '50'1 23230.00 -- -___ x TOP=59.0 TOP=58.7 -- - 59.55 TOE=58.7 s TOE=58.25 �. 59.65 ' 59.55 omasT` ` w^-r6 a_ 59.65 z o S MSTr, CV N _ W 58 75 5�� RISER ROOM 1 Q' 8.33% SSCO � , \, �� ., o Qj 4 (IE=55.80 59.652 k; CB#3 EXswy ' o 59.25 �` R I NI =S� 65 YA DRAIN I - S CD V 59.35 '� , ' KIM = q f% FINISHED PER DTL 1 C3 C 6 # G 59.35 `� ` RIM = 59.50 ; V 58.85 I FLOOR=59.75 �, YARD DRAIN $, IE = 57.57 \ 4 SSCO �,, ,� � �,�� 59.55 I (IE=55.83) SSCO 59.65 S 5 R M DT59150 3 3% 58.75 I - '"` (IE=55.9 ftl 59.65 " 2.0' IE = 58.15 6"0 ` ` CDJ#2 INSTALL &SECURE Ya ALUMINUM OR STAINLESS 10' ,\ L YARD DRAIN I C STEEL SCREEN OVER INLET OF 6 0 PIPE PER DTL 1 C3 OUTS 36 LF 6"0 5 DITCH IE=58.29 h\ RIM = 59.50 " 58.4559.45 \,;, ti \29 LF 6 ADS IE = 57.39 �� ,. ADS N-12 59.55 N-12 ®0.5% 59.55 ®0.5% C 59.65 FINISHED I 8� X 6 1 TOP=58.85 59.65 FLOOR=59.75' TOE=58.2 \t 5 58.95 59 55 * ` 1 50 LF 8 ��� PVC 6-INCH DEEP & 1 FOOT 5 .05 \��� � � 59 ;._ SDR-35 ®0.5% 59.55 WIDE LANDSCAPING RUNOFF .65 59.55e� \ CONVEYANCE DITCH (MIN '* I SLOPE=0.5%), TYP 65 LF 6 0 ADS SSCO N-12 n 0.5% 12 LF f L64 �-168 LF 8"0 CB 1 CLEANOUT 57 LF 60 S (IE=55.51) t" '4 PVC SDR-35 YARD"'DRAIN N-122 ® 0. % CLEANOUT 10' WATERLINE SPRINKLER SUP °g5 ® 0.5% 59.65 l+4 10 EASEMENT LINE SIZE I PER DTL 1 C3 CLEANOUT$Xg WyE 59.65 REC. NO. 3832556 59.65 59 55� -- -- (1) 8" TEE (FLxFLxFL) W/CONC BLOCKING I cppiNki P"R nFci RIM = 59.3 IE = 57.10 FINISHED �1 UTILITY CROSSING PLAN 1 1 = 30' �I A 4 - -r - INSTALL CONC CASING ALONG NEW59- SEWER LINE SIM_?D___DTL 9/C4 5 DITCH IE=58.50 N-12 -ENCE 50� n S89'50'16" n230.00' DITCH 58.86 ° E=58.11 58.53 �6 0� 58.67 ALL &SECURE Ya" ALUMINUM OR STAINLESS STEEL SCREEN OVER INLET OF 6"0 PIPE -- - 6'CYCL6NEXFENCE X f-I X X WOOD r FEN`CEX Drafter Name: A. PAUL I Plot Date: JUL 30 2009 11:03:41 1 Last Modified Date: JUL 30 2009 10:26:35 1 Submittal: REVISION 4 ��ff TOP-0 8.6 YARD��DRAIN WOOD fFENCEX C B 5 Y' TQE=58.1 PER DTL 1 C3 YARD DRAIN RIM = 59.55 PER DTL 1 C �g IE = 57.64 °�g� RIM = 59.50 -� A �1�. gf58,90'. a t . ��IE = 57.82 a DOWNSPOUT (SIZE BRANCH PER SPRINKLER DESIGN) CONVEYANCE PIPE (1) 8%8%6" TEE (FLxFLxFL) DITCH IE=58.66 W/CONC BLOCKING (1) 8"0 GATE VALVE (COA#6783) (FLxMJ) (1) 6"0 GATE VALVE (FLxMJ) 1 DITCH IE=58.66 (1) GATE VALVE (SIZE TOP-59.0 PER SPRINKLER DESIGN) TOE=58.25 (2) 8"0 DI NIPPLES W (1) 8"0 DI COUPLING XXz h`b� J I� • I0 GRADING. DRAINAGE & UTILITIES PLAN UTILITY CROSSING TABLE CITY BACKFLOW PREVENTION CONSTRUCTION NOTES BACKFLOW PREVENTION DEVICES MEET THE FOLLOWING REQUIREMENTS: 1. INSTALLATION OF BACKFLOW PREVENTION ASSEMBLIES SHALL COMPLY WITH THE CITY'S TECHNICAL MEMO INSTALLATION REQUIREMENTS FOR BACKFLOW PREVENTION ASSEMBLIES. 2. INSTALLATION OF BACKFLOW PREVENTION ASSEMBLIES WILL REQUIRE A BACKFLOW ASSEMBLY PLUMBING PERMIT. 3. BACKFLOW PREVENTION ASSEMBLY SHALL BE ON THE CURRENT WASHINGTON STATE DEPARTMENT OF HEALTH LIST OF APPROVED BACKFLOW ASSEMBLIES. 4. BACKFLOW PREVENTION ASSEMBLIES SHALL BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AND INSPECTED BY A CITY OF AUBURN CROSS CONNECTION CONTROL SPECIALIST. 5. PRIOR TO INSTALLATION, 4 SETS OF BACKFLOW PREVENTION ASSEMBLY PLANS SHALL BE SUBMITTED TO THE CITY FOR APPROVAL BY A CROSS CONNECTION CONTROL SPECIALIST. THE CROSS CONNECTION SPECIALIST CAN BE REACHED AT (253) 288-3169 OR (253) 931-3064. WATER MAIN PREVENTING REVERSE FLOW PRIOR TO BEGINNING THE WATER MAIN INSTALLATION THE CONTRACTOR SHALL PREPARE A PLAN SHOWING THE INTENDED METHOD, IN DETAIL THAT WILL BE INCORPORATED TO INSURE THE PREVENTION OF REVERSE FLOW FROM ENTERING THE EXISTING DISTRIBUTION SYSTEM. THE PLAN SHALL MEET THE REQUIREMENTS OF WAC 246-290-490. THE CONTRACTOR SHALL CONSIDER THIS PLAN AS A SUBMITTAL, AND SUBMIT IT PER THE SPECIFICATION PROVIDED IN SECTION 1-06 (SUBMITTALS). THE ENGINEER MUST APPROVE THIS PLAN PRIOR TO THE CONTRACTOR STARTING WORK ON THE WATER MAIN. YARD DRAIN C3 NTS INSTALL 90' DI BEND W/CONC BLOCKING (SIZE PER SPRINKLER DESIGN) FIRE SUPPLY CONNECTIONS 1 = 10 MATCH RIM ELEV. TO FINISHED GRADE OUT A HOLE IN BETE PIPE LARGE ,H TO ACCOMMODATE PIPE. PATCH W/NON- SHRINK GROUT - 4!' FIvC SPIRt t+! KLe? LU 14 6 2 1/Z DOMesST/c- wA'rF9. INSTALL 90' DI BEND (MJXMJ) W/CONC BLOCKING (SIZE PER SPRINKLER DESIGN) INSTALL 6"0 UL/FM-APPROVED FIRE c DEPT CONNECTION PER COA STD DTL WATER-05 Dc. �- INSTALL FH (COA#4197) PER COA STD DTL O' WATER-07 1`7 LF FIRE SPRINKLER SUPPLY LINE (SIZE PER SPRINKLER DESIGN) CROSSING NUMBER UTILITY PIPE MATERIAL SIZE (IN.) OUTSIDE DIAMETER (IN.) INVERT ELEVATION (FT.) UTILITY PIPE MATERIAL SIZE (IN.) OUTSIDE DIAMETER (IN.) INVERT ELEVATION (FT.) SEPARATION (FT.) RS TE An ._..,__ WATER._ -DF EEASS --&2 8 --9.05 61.18- SEWER -GWRE . W3 WATER PVC SDR-21 1.5 1.90 3•'1.97 STORM CONCRETE 30 37.00 1.00 W4 WATER PVC SDR-21 1.5 1.90 -81-97 SEWER CONCRETE 8 10.50 -64-. • �'¢ 3 2.57 o PVC-SDR-21 1 1.90 55.94 STORM _ W9 WATER DI CLASS 52 6 6.90 51.18 STORM CONCRETE 30 37.00 52.91 1.15 W10 WATER DI CLASS 52 6 6.90 51.18 SEWER CONCRETE 8 10.50 54.93 3.17 W11 WATER DI CLASS 52 6 6.90 55.30 STORM ADS N-12 6 6.92 57.55 1.67 S1 SEWER PVC SDR-35 6 6.28 54.92 STORM ADS N-12 6 6.92 57.44 2.00 S2 SEWER PVC SDR-35 8 8.40 55.20 STORM ADS N-12 6 6.92 57.12 1.22 S3 SEWER PVC SDR-35 1 8 8.40 1 55.51 STORM ADS N-12 6 6.92 57.42 1.21 S4 SEWER PVC SDR-35 1 8 8.40 1 55.63 STORM ADS N-12 6 6.92 57.50 1.17 UTILITY CONFLICT NOTE: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES, WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE ® 1-800-424-5555 AND THEN POTHOLING ALL EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT RUPERT ENGINEERING, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. RECORD DRAWING CERTIFICATION THESE DRAWINGS CONFORM TO THE R'S CONSTRUCTION RECORDS. -z4 BY- - DATE: 4 f IO TITLE/POSITION: CONFIRMED BY CITY: L--ell%l DATE: PROJECT REF: FAC08-0024 9� '7-30Zo f THESE PLANS ARE APPROVED FOR CONFORMANCE WITH THE CITY OF AUBURN'S ENGINEERING DIVISION REQUIREMENTS APPROVED BY: J, DATE APPROVED: ci Q o � a � 07 00 0 E=3 Q J n� 5; ao U ao V) =3 L0 L[i n n� w N 0 z T (,L.� 3 s U = � n� o � oN J > a00 �COL Z) ��Ln z � 0 a' r C7 z z � m Z c� Q Q _Z -! N O N LLJ W ~ I= w U o z W N W J Q o Lc)/ u C N C7 Z Q � Z � Q N W ^t_ C Z � 0 ::D Q w V^`'� J LLJ cn 001 c\0 :L � � I--� L0 0 W w W N Z W W W O 0 g C) C> a N � � C) U 0 U 0 U , \ g it p Z U U C� w w w w 0 w a- Z cD V) ,M E ;� c WASh�� G 4JL11 STE��`' e s��NAL EN DATE 09.11.08 DRAWN KWT CHECKED AEP JOB NO. 08105 SHEET NO. C 3 SHEET 3 OF 7 /Q pa016 BASE COMPACTION PROCEDURE 1. PROOF -ROLL THE EXISTING GRAVEL TO VERIFY A MINIMUM CBR OF 10. 2. ANY SOFT SPOTS ENCOUNTERED SHALL BE OVER -EXCAVATED AT LEAST 12 INCHES. FILL THE EXCAVATION WITH BASE COURSE GRAVEL (LESS THAN 5% FINES). COMPACT THE FILL TO 95% MINIMUM. 3. PROOF -ROLL THE FILLED SOFT SPOTS TO VERIFY A MINIMUM CBR OF 10. GRADE 1" DOWN CONCRETE CURB WHERE SHOWN FROM TOP OF 1 /2" 5 1 /2" 1 /2" ,PAVING 2" CLASS "B" A.C. PAVING � SLOPE PROVIDE 1'-0" LEVEL AREA D- WHERE GRADE SLOPES SUBGRADE SOIL. 4 OZ NON -WOVEN FILTER FABRIC - BROUGHT UP TO TOP OF CONTROL JOINT BETWEEN IMPERVIOUS & PERVIOUS CONC. (ALL AROUND) �i7/7/777/77T,_.DOWNWARD OUTSIDE OF PAVING 2" LEVELING TOP COURSE COMPACTED TO 95% PROCTOR 4" CRUSHED ROCK BASE TO BE PROOF -ROLLED PER BASE COMPACTION PROCEDURE NOTES ALT PAVING SECTION 4" CONC WALKWAY EXPANSION JOINT (20'oc) DUMMY JOINT (10'oc) �°a" CHAMFERco 1/,4; 12 SLOPE A.C. PAVING SLOPE VARIES WHERE OCCURS a a d a d a _ III (2) #4 CONT. �I I 6" 12" MIN. CLASS "A" FILL F COMPACT TO 95% - CONCRETE SHALL HAVE 28-DAY - REINFORCING SHALL BE PER COMPRESSIVE STRENGTH OF 3000 PSI ASTM A-615, GRADE 60 AND 5% AIR ENTRAINMENT 2 SIDEWALK C4 NTS #4 EW @ 12"oc CONTROL JOINT PER CONCRETE PAVEMENT PER CONSTRUCTION NOTE 2 CONSTRUCTION NOTE 3 CONCRETE PAVEMENT PER c PERVIOUS CONCRETE, SIDEWALK, CONSTRUCTION NOTE 3 BLDG FOUNDATI N, OR SUB -GRADE SOl ° 4 ° 00°O° O°O°O°O°O 0000 0 0 0 0 0 0 °O°O 0°00 0000°0 11 CO d 0000 00 OOOOO 00 _ a � 4oz NON -WOVEN SEPARATE SHEET OF 4 OZ FILTER FABRIC 6 NTS NON -WOVEN FILTER FABRIC 1" TO 3/4" CLEAN ROCK CONFORMING UNDER PERVIOUS PUMT. TO WSDOT SPEC 9-03.12(5) LIGHTLY COMPACTED SUB -GRADE TO BE TO 85% OF ITS MAX DRY DENSITY PREPARED PER SUB -GRADE IN 2 TO 3 LIFTS COMPACTION PROCEDURE NOTES THIS SHEET ATYPICAL PERIMETER JOINT AT BUILDING EDGE NTS 4 OZ NON -WOVEN FILTER FABRIC - BROUGHT UP TO TOP OF PERIMETER JOINT BETWEEN NEW CONCRETE PAVEMENT AND ASPHALT PAVEMENT CONCRETE PAVEMENT PER 7 CONSTRUCTION NOTE 3 G Q. O a a a 4 VPII\ILJ `Iv 6' 1" TO 3/4" CLEAN ROCK CONFORMING TO WSDOT SPEC 9-03.12(5) LIGHTLY COMPACTED TO 85% OF ITS MAX DRY DENSITY IN 2" TO 3" LIFTS TRUNCATED DOMES PER DTL THIS SHEET TYPICAL PERIMETE NTS 6" CONC CURB 1 %3"WIDE GROOVE WITH RUBBER ASPHALT FILLER ASPHALT PAVEMENT `'-- 4oz NON -WOVEN FILTER FABRIC SUB -GRADE TO BE PREPARED PER SUB -GRADE COMPACTION PROCEDURE NOTES THIS SHEET IT ASPHALT PAVEMENT 2' o o o o o o o o o o d' a °. o o o o o 0 o o o o o°000 000., -.,000 o°°000 " c o o 0 o o o° o o O o o 0 o 0 o o o 0000000°° d 8.33% d ° o o o o o 0 0 0 0 0 r ¢ _°°° o o o o o 0 o < '..0000000000d' o o o o o o o o o o <" ° t o o o o o o o o o o < ,° o o o o o oo 000 . o o o o o o° o o o 0 0 0 0 0 0 0 0 0 0. o°000 oo°o° ,d. ° aa. a o o 0 0° o o o° o °. . . ...:.:.:.:. PAVEMENT PER PLANS MIN. MAX. A 1 5/8" 2 3/8" B 5/8" 1 1 /2" C 7/16" 3/4" D 7/8" 1 7/16" 1" TO 3/4" CLEAN ROCK CONFORMING TO WSDOT SPEC 9-03.12(5) LIGHTLY COMPACTED TO 85% OF ITS MAX DRY DENSITY IN 2" TO 3" LIFTS 5 TYPICAL LONGITUC C4 NTS 0 ELEV=57.10 VERIFY 1'-0" MIN STAINLESS STEEL 4FASTENERS WHITE LETTERS & SYMBOL 1 ON BLUE BACKGROUND Z Z w� > PARKING ONLY METAL SIGN, BOLT TO STEEL PIPE POST Or VAN ACCESSIBLE C) ADDITIONAL SIGN AT VAN ACCESSIBLE PARKING SPACES ONLY � o GRADE LO 1" CONC 1Y" GALVANIZED SCHEDULE 40 WASH STEEL PIPE W/CAP 4 ° dl o� NOTES: st °' 1. SIGN TO BE PER LOCAL JURISDICTION REQUIREMENTS. `1'/ VERIFY SIZE, SHAPE & VERBAGE 2. PROVIDE SIGN AT EACH HANDICAPPED PARKING STALL. 8" DIAMETER CONCRETE FOOTING 3 ACCESSIBLE PARKING SIGN C4 NTS 1/4"x2" SAWCUT; FILL WITH SEALANT (PLACE BOND BREAKER TAPE AT BOTTOM OF SAWCUT PRIOR TO PLACING SEALANT) L CONSTRUCTION JOINT US CONCRETE SLOPE PER PLANS D 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 000000 0 0 0 0 0 0000000 0 0 0 0 00 0 0 0 0 00 0 0 0 0 0 0 0 0 0000 0 0 0 00000000 0 0 0 0 0 0 0 0 0 0 0 0 0 0°O°O°OO°O°O°°00000000000000000 /-SECURE/ BURY FILTER FABRIC BEHIND UPPER EDGE OF PERVIOUS PAVEMENT -4 OZ NON -WOVEN FILTER FABRIC ALL AROUND 1" TO 3/4" CLEAN ROCK CONFORMING SUB -GRADE TO BE TO WSDOT SPEC 9-03.12(5) LIGHTLY COMPACTED PREPARED PER SUB -GRADE TO 85% OF ITS MAX DRY DENSITY COMPACTION PROCEDURE IN 2" TO 3" LIFTS NOTES THIS SHEET MAXIMUM SEASONAL GROUNDWATER DESIGN ELEVATION AT 54.1' (PER PANGEO INCORPORATED) TYPICAL PERVIOUS PAVEMENT EDGE JOINT NTS DETECTABLE WARNING PATTERN AREA SHALL BE YELLOW, IN COMPLIANCE WITH WSDOT STD. SPEC. 8-14.3(3) BACKFILL PER CITY STD fA DTLS AS SPECIFIED ON I B I THIS SET OF PLANS. I , I I Al I 1 --� D- + o TRUNCATED DOMES DETAIL 8 CURB RAMP C4 NTS \\STORAGE\Data\2008\08105\Civil\C4-105.dwg Drafter Name: A. PAUL Plot Date: JUL 30 2009 11:04:01 Last Modified Date: JUL 30 2009 10:27:42 Submittal: REVISION 4 SECTION A/C7 PERVIOUS CONCRETE PAVEMENT NOTES- Q CERTIFICATION STANDARDS U EACH APPLICANT MUST CARRY A CURRENT ACI CERTIFICATION AS FLATWORK TECHNICIAN OR FLATWORK FINISHER. EACH APPLICANT MUST TAKE AND PASS A PROFICIENCY EXAM DEMONSTRATING A THOROUGH KNOWLEDGE OF PORTLAND CEMENT PERVIOUS PAVING. THE EXAM SHALL BE GIVEN ANNUALLY AT A TIME AND V) PLACE SET BY PCPA. oo Fk-n Z FOR PCPA CERTIFICATION, EACH APPLICANT MUST SUBMIT A MINIMUM OF THREE (3) PROJECTS, TOTALING 100,000 SQUARE FEET INSTALLED WITHIN AN EIGHTEEN MONTH PERIOD OF TIME, SAID INSTALLATIONS V Q HAVING BEEN EXAMINED AND CERTIFIED TO BE PCPA COMPLIANT. _j 00 TEN PERCENT OF EACH CREW MUST ALSO BE CURRENTLY ACI CERTIFIED FLATWORK TECHNICIANS OR FLATWORK FINISHERS. INDIVIDUAL CREW MEMBER PCPA CERTIFICATIONS ARE DESIRABLE. 0 N 00 V CD rn INSTALLATION CREWS SHALL HAVE A MINIMUM OF 10% CURRENT ACI CERTIFIED FLATWORK TECHNICIANS AND/OR FINISHERS. CERTIFIED PORTLAND CEMENT PERVIOUS INSTALLATION CREWS. PRIOR TO AWARD O w OF THE CONTRACT, THE PLACING CONTRACTOR SHALL FURNISH OWNER/ENGINEER/ARCHITECT A STATEMENT ATTESTING TO QUALIFICATIONS AND EXPERIENCE TO THE FOLLOWING: A MINIMUM OF TWO (2) W LO COMPLETED PCPA CERTIFIABLE PROJECTS -HAVING LESS THAN 2% RAVELING* AND/OR CONSOLIDATION AND WELL DRAINING Z o (A MINIMUM OF 40,000 S.F. TOTAL) WITH ADDRESSES. IN -SITU PAVEMENT TEST RESULTS INCLUDING VOID CONTENT , UNLESS PCPA EXEMPT. SAMPLE OF PRODUCT (IE., CORE, TEST PANEL, OR SAMPLE FROM A PREVIOUS PLACEMENT) IF THE PLACING CONTRACTOR HAS INSUFFICIENT EXPERIENCE WITH PORTLAND CEMENT PERVIOUS CONCRETE PAVEMENT, RETAINING AN EXPERIENCED CONSULTANT (SUCH AS DAVE W 3 FRENTRESS, GLACIER NW, DFRENTRESS@GLACIERNW.COM TO MONITOR PRODUCTION, HANDLING, AND PLACEMENT OPERATIONS, EVEN AT THE PLACING CONTRACTOR'S EXPENSE, IS PROBLEMATIC, AT BEST, AND � co CANNOT COMPENSATE FOR THE LACK OF PROPER PERVIOUS EXPERIENCE AND/OR TECHNICAL KNOWLEDGE NECESSARY TO A SUCCESSFUL INSTALLATION. Z n� V H 0c CONCRETE MIX DESIGN Q D 0 cm 9 °° co CONTRACTOR SHALL FURNISH A PROPOSED MIX DESIGN WITH PROPORTIONS OF MATERIALS TO OWNER OR AGENT PRIOR TO COMMENCEMENT OF WORK. PORTLAND CEMENT TYPE I OR II CONFORMING TO N _ ASTM C 150 OR PORTLAND CEMENT TYPE IP OR IS CONFORMING TO ASTM C 595. USE N0. 8 COARSE AGGREGATE (3/8 TO N0. 16) PER ASTM C 33; OR N0. 89 COARSE AGGREGATE (3/8 TO NO 50) O 61 J PER ASTM D 448. IF OTHER GRADATION OF AGGREGATE IS TO BE USED, SUBMIT DATA ON PROPOSED MATERIAL TO OWNER FOR APPROVAL. ADMIXTURES CAN BE TYPE A WATER REDUCING ADMIXTURES - II, Q '- ASTM C 494, TYPE B RETARDING - ASTM C 494, AND TYPE D WATER REDUCING/RETARDIN - ASTM C 494. ALSO, A HYDRATION STABILIZER CAN BE UTILIZED AND IS RECOMMENDED IN THE DESIGN AND PRODUCTION OF PERVIOUS CONCRETE. THIS STABILIZER SUSPENDS CEMENT HYDRATION BY FORMING A PROTECTIVE BARRIER AROUND THE CEMENTITIOUS PARTICLES, WHICH DELAYS THE PARTICLES FROM `L ACHIEVING INITIAL SET. THE ADMIXTURE'S PRIMARY FUNCTION SHOULD BE AS A HYDRATION STABILIZER; HOWEVER, IT MUST ALSO MEET THE REQUIREMENTS OF ASTM C 494 TYPE B RETARDING OR TYPE D CDWATER REDUCING/RETARDING ADMIXTURES. FOR PAVEMENTS SUBJECTED TO VEHICULAR TRAFFIC LOADING, THE TOTAL CEMENTITIOUS MATERIAL SHALL NOT BE LESS THAN 600 POUNDS PER CUBIC YARD. THE z z VOLUME OF AGGREGATE PER CUBIC YARD SHALL BE EQUAL TO 27 CUBIC FEET, WHEN CALCULATED AS A FUNCTION OF THE UNIT WEIGHT DETERMINED IN ACCORDANCE WITH ASTM C 29 JIGGING PROCEDURE. AGGREGATE SHOULD BE WASHED; FINE AGGREGATE SHOULD NOT BE USED. MIX WATER SHALL BE SUCH THAT CEMENT PASTE DISPLAYS A WET, METALLIC SHEEN, WITHOUT CAUSING THE PASTE TO FLOW FROM m SUB -GRADE COMPACTION PROCEDURES THE AGGREGATE, (MIX WATER YIELDING A CEMENT PASTE WITH A DULL -DRY APPEARANCE HAS INSUFFICIENT WATER FOR HYDRATION.) INSUFFICIENT WATER RESULTS IN INCONSISTENCY IN THE MIX AND POOR Z Q BOND STRENGTH. HIGH WATER CONTENT RESULTS IN THE PASTE SEALING THE VOID SYSTEM PRIMARILY AT THE BOTTOM AND POOR SURFACE BOND. 'Q Z 1. EXCAVATE TO THE ELEVATION OF THE BOTTOM OF CLEAN ROCK. (IN N AREAS WHERE THE EXPOSED SOILS AT THE BOTTOM OF THE PLACING AND FINISHING EOUIPMENT -' PROPOSED INFILTRATION BED ARE THE SHALLOW SILTY MATERIALS O IDENTIFIED IN THE GEOTECHNICAL REPORT PREPARED BY PANGEO, THE CONTRACTOR SHALL PROVIDE MECHANICAL EQUIPMENT OF EITHER SLIPFORM OR FORM RIDING WITH A FOLLOWING COMPACTIVE UNIT THAT WILL PROVIDE A MINIMUM OF TEN (10) PSI VERTICAL FORCE. THE = EXCAVATION SHALL BE CONTINUED UNTIL THE NATIVE SANDY SOIL IS PERVIOUS CONCRETE PAVEMENT WILL BE PLACED TO THE REQUIRED CROSS SECTION AND SHALL NOT DEVIATE MORE THAN 1 /2+- INCH IN TEN (10) FEET FROM PROFILE GRADE. A FULL WIDTH ROLLER OR W ENCOUNTERED. THE EXCAVATION SHALL THEN BE BACKFILLED WITH OTHER FULL WIDTH COMPACTION DEVICE THAT PROVIDES SUFFICIENT COMPACTIVE EFFORT SHALL BE USED IMMEDIATELY FOLLOWING STRIKE -OFF OPERATION. AFTER MECHANICAL OR OTHER APPROVED L LJ ON -SITE NATIVE SAND OR IMPORTED FREE -DRAINING GRANULAR STRIKE -OFF AND COMPACTION OPERATION, NO OTHER FINISHING OPERATION, ASIDE FROM CONTRACTION JOINTING, MINOR BACKFILLING AND FINISH ROLLING SHALL BE ALLOWED. IF VIBRATION, INTERNAL OR ("- MATERIAL TO THE DESIGN ELEVATION AT THE BOTTOM OF THE CLEAN SURFACE APPLIED, IS USED, IT SHALL BE SHUT OFF IMMEDIATELY WHEN FORWARD PROGRESS IS HALTED FOR ANY REASON. PLACEMENT SHALL BE A MAXIMUM OF FIFTEEN (15) FEET WIDE. U z ROCK .) w TESTING GUIDELINES ry 2. PROOF -ROLL SUB -GRADE SOIL WITH EITHER A PNEUMATIC TIRED ROLLER OR SINGLE AXLE LOADED DUMP TRUCK. PROOF ROLL AT 2 PRIMARY TESTING OF PERVIOUS CONCRETE IS FOR VOIDS. ACTUAL VOID CAPACITY, WITH ONE QUARTER TO THREE -EIGHT INCH WASHED AGGREGATE, IS TWELVE TO SIXTEEN PER CENT. ►F HEAVY USE IS A W to TO 4 MPH. IDENTIFIED SOFT SPOTS ARE TO BE REPAIRED PER NOTE CONSIDERATION, GRANITE MAY BE A MORE APPROPRIATE CHOICE. IF FINISHED SURFACE IS COMPLIANT WITH PCPA INSPECTION STANDARDS - LESS THAN 2% RAVELING AND/OR CONSOLIDATION - A HOSE 3 BELOW. PRIOR TO PROOF ROLL, CONTRACTOR MAY LIGHTLY TEST MAY OBVIATE THE NEED FOR CORE TESTS, PROVIDING THE SURFACE APPEARS TO READILY ABSORB THE WATER FLOW WITH MINIMUM SPREAD, AND CONTRACTOR HAS A PROVEN HISTORY OF QUALITY ^ ^ COMPACT SUB -GRADE TO 85% STD. PROCTOR TO HELP PROOF -ROLL (PCPA STANDARD COMPLIANT) PERVIOUS CONCRETE INSTALLATIONS. �, Q RESULTS W/O EFFECTING SOIL PERMEABILITY. UNIT WEIGHT TESTING IS FUNCTIONAL ONLY WITHIN THE PARAMETERS OF EACH LOAD'S PLACEMENTS, BECAUSE TEMPERATURE, WIND, HUMIDITY, CEMENT OR STONE CHARACTERISTICS TEND TO BE CONSTANT o N TER SHA BE OVER EXCAVATED AT LEAST 12 VARIABLES REQUIRING DESIGN MIX TO BE CHANGED AS FREQUENTLY AS FROM ONE TRUCKLOAD TO THE NEXT 3. SOFT SPOT ENCOUN ED LL - , INCHES. FILL EXCAVATION WITH CLEAN ROCK OR BALLAST PER WSDOT STD SPEC. 9-03.12 (5) OR 9-03.9 (1) & (2). COMPACT TC A MINIMUM OF AT LEAST ONE TEST PANEL, TWO HUNDRED FIFTY (250) SQUARE FEET IN SIZE EACH, SHOULD BE DONE IN ADVANCE OF INSTALLATION TO DETERMINE CONTRACTOR'S ABILITY TO COMPLETE THE 90% STD PROCTOR. ENTIRE INSTALLATION IN A PROFESSIONAL, WORKMANLIKE MANNER. PANELS ARE GENERALLY NOT NECESSARY FOR PCPA CERTIFIED CONTRACTORS, OR CONTRACTORS WHO HAVE INSTALLED MORE THAN 100,000 SQUARE FEET OF PERVIOUS CONCRETE WITHIN EIGHTEEN MONTHS PRIOR TO INSTALLATION, AND SAID INSTALLATIONS ARE CERTIFIED TO BE COMPLIANT WITH PCPA INSPECTION STANDARDS. 4. BUILDING AND DEMO EXCAVATION SHALL BE FILLED WITH CLEAN ROCK OR BALLAST PER WSDOT STD SPEC. 9-03.12 (5) OR 9-03.9 A MINIMUM OF TEN (10) PERCENT OF THE INSTALLATION CREW HOLD CURRENT AMERICAN CONCRETE INSTITUTE CERTIFICATIONS AS FLATWORK TECHNICIANS AND/OR FINISHERS CARDS. (1) & (2). IF CLEAN NATIVE SOIL IS AVAILABLE ON SITE IT MAY BE USED PER THE DIRECTION OF THE OWNERS REP. COMPACT TO 90% PEC110N STANDARDS STD PROCTOR. SURFACE MUST HAVE LESS THAN TWO (2) PERCENT TOTAL RAVELING AND/OR CONSOLIDATION. ANYTHING GREATER SHALL CALL FOR REMOVAL AND REPLACEMENT. JOINT CONSTRUCTION NOTES: CONTRACTION JOINTS SHALL BE INSTALLED IN WET OR DRY CONCRETE, MINIMALLY EVERY 20 FEET, BUT CAN BE INSTALLED PER ACI RECOMMENDED THIRTY-SIX TIMES THE DEPTH, BUT NOT TO EXCEED THEIR ONE AND A HALF TIMES WIDTH RULE. ALL RADII SHALL HAVE ACI STANDARD CONTRACTION/TRANSVERSE JOINTING. ISOLATED CONTROL JOINTS SHOULD BE USED AROUND PERMANENT STRUCTURES, 1. JOINT SEALANTS FOR SAWED CONSTRUCTION JOINTS: JOINT SEALANTS BETWEEN ABUTTING PERVIOUS AND ANYTHING ELSE OF SIGNIFICANTLY DIFFERING COEFFICIENT OF EXPANSION. THEY ARE GENERALLY NOT REQUIRED BETWEEN PERVIOUS CONCRETE AND CONVENTIONAL SHALL MEET THE REQUIREMENTS OF AASHTO M173 CONCRETE JOINT CONCRETE CURBING. SEALER, HOT POUR ELASTIC TYPE. 2. JOINT SEALANT FOR OTHER CONCRETE CONTROL JOINTS: JOINTS HOSE TESTING TO DETERMINE WATER ABSORPTION CAPABILITIES IS SIMPLE. TURN THE WATER ON, TO A FULL STREAM AT AMBIENT (40 TO 60PSI) PRESSURE, HOLDING IT APPROXIMATELY 30" FROM THE SHALL HAVE A 3/4" THICK PRE MOLDED FILLER CONFORMING TO SURFACE; ONCE THE WATER HITS THE SURFACE, WATCH HOW FAR IT TRAVELS BEFORE IT DISAPPEARS INTO THE CONCRETE; IF THE SURFACE IS RELATIVELY FLAT, TWO FEET IS GREAT, FOUR FEET IS GOOD; A THE INDICATE A RTAIN AMOUNT OF CONSOLIDATION AND A CORE SAMPLE MAY BE DESIRABLE TO DETERMINE VOID STRUCTURE. ANOTHER MORE SCIENTIFIC FIELD TEST SIX FOOT SPREAD ON E LEVEL MAY CERTAIN 0 , THE SPECIFICATIONS FOR "PRE FORMED EXPANSION JOINT FOR WOULD BE TO USE A MEASURED WATER SOURCE AND TIME THE RATE OF FLOW INTO THE SLAB AND MEASURE THE FOR EXAMPLE, 30 GALLONS A MINUTE WITH A FOUR SQUARE FOOT SPREAD IS CONCRETE PAVING AND STRUCTURE CONSTRUCTION" AASHTO M213 EXCELLENT. A STANDARD PERCOLATION TEST WOULD WORK, TOO, ALTHOUGH SOMETIMES THE DRAINAGE CAPABILITIES OF PERVIOUSSPREAD; EXCEED THE MEASURABLE CAPACITY. EXCEPT THE REQUIREMENT FOR WATER ABSORPTION, WHICH IS Ld DELETED. THE JOINT ABOVE THE FILLER SHALL BE SEALED WITH A MAINTENANCE STANDARDS TWO-PART URETHANE JOINT SEALER CONFORMING TO ASTM C920 FOR USE IN VEHICLE TRAFFIC AREA. DIMENSIONS OF SEALER SHALL CLOGGING IS MAINLY A MATTER OF DESIGN. IF STORMWATER FROM OUTSIDE OF THE PARKING LOT FLOW ACROSS, INTRODUCING FINES INTO THE SYSTEM, SOME CLOGGING CAN OCCUR IN THE VICINITY OF N BE IN ACCORDANCE WITH THE SEALER MANUFACTURER'S THE FLOW. AREAS OF THE PAVEMENT NOT EXPOSED TO THIS FLOW WILL REMAIN UNCLOGGED, RESULTING IN THE "AVERAGE" PERFORMANCE OF THE ENTIRE PARKING LOT TO REMAIN GOOD. IF THE PARKING RECOMMENDATIONS. LOT IS DESIGNED TO TAKE CARE OF THE RAIN THAT FALLS DIRECTLY ON IT'S SURFACE, THE ONLY SOURCE OF FINES WILL BE WIND BLOWN OR TRACKED IN ON VEHICLE TIRES. CORING STUDIES IN FLORIDA INDICATED THAT, ON WELL -DESIGNED PERVIOUS CONCRETE PARKING LOTS, LESS THAN 10% LOSS OF INTERNAL VOLUME HAS OCCURRED DUE TO INFILTRATION OF FINES AFTER 12 YEARS. SWEEPING, 3, CLASS A (3/4") AIR ENTRAINED PORTLAND CEMENT CONCRETE WITH BLOWING, VACUUMING AND OTHER NORMAL METHODS OF MAINTAINING PARKING LOTS ARE IMPORTANT IN MINIMIZING THE MATERIALS AVAILABLE TO CLOG PERVIOUS CONCRETE PAVEMENTS. LANDSCAPE COMPRESSIVE STRENGTH OF 3000 PSI WITHIN 4 DAYS SEE TYPICAL MAINTENANCE PERSONNEL SHOULD BE CAUTIONED TO AVOID INTRODUCING FINE MATERIALS ONTO THE SURFACE OF PERVIOUS CONCRETE PAVEMENTS. TESTS IN FLORIDA INDICATE THAT THE PERVIOUS CONCRETE PAVEMENT SECTION THIS SHEET FOR REINFORCEMENT. CONCRETE PAVEMENTS CAN BE VACUUMED OR PRESSURE WASHED TO REMOVE FINES. THE NORTHWEST MAINTENANCE REMOVAL OF FIR NEEDLES, LEAVES, ETC. IS BEST DONE WITH A BLOWER; HAVE THE MATERIAL COLLECTED OFF THE PERVIOUS PAVEMENT, IF POSSIBLE. BE SURE GROUNDS PERSONNEL ARE TRAINED TO BAG GRASS CLIPPINGS INSTEAD OF BLOWING THEM ONTO A PERVIOUS SURFACE. BE SURE OTHER TRADES KNOW WHAT THE PERVIOUS SURFACES DO, AND EDUCATE THEM ON MAINTENANCE. SUB -CONTRACTORS HAVE DUMPED LOADS OF BARK, FERTILIZER, DIRT, SAND, ETC. ONTO PERVIOUS PAVEMENTS -NOT A GOOD PRACTICE! IF THERE ARE ROOF DRAINS HEADING TO PERVIOUS SURFACES, PLACE A CATCH BARREL BENEATH THEM TO FILTER OUT FINES AND DEBRIS. THE PERVIOUS SURFACES CAN USUALLY HANDLE THE WATER VOLUME, BUT WE WANT TO AVOID THE SUSPENDED FINES. IF THESE IS NO LEAVES, NEEDLES, DEBRIS, ETC. ON THOSE ROOF SURFACES, THIS IS NOT SUCH A CRITICAL PAVEMENT PATCH AND ISSUE. 1.5 z TRENCHING PER CITY 5' NEW CONC S/W 62' o DTLS AS SPECIFIED ON _ ..._.._.,_ THIS SET OF PLANS. ,,,, ,-- PERVIOUS CONCRETE - prWiN is rrnnirRpTF (If A C7 L/2 L/2 GRAVIT SEWER PIPE PIPE INVERT THE NEW WATER MAIN MUST BE INSTALLED SO AS TO BE CENTERED BETWEEN JOINTS ° OF THE EXG SEWER MAIN AT THE POINT OF CROSSING. a. L-ENCASE NEW WATER PIPE WITH CONC AS J SHOWN. CONCRETE ENCASEMENT MUST END WHERE NECESSARY TO ENSURE THAT JOINTS ARE NOT ENCASED. /"_q� UTILITY CROSSING DETAIL C� NTS cq 0 100-YEAR MAXIMUM RETENTION WATER SURFACE ELEVATION @ 57.93' �- CLEAN ROCK FOR 10 TYPICAL PARKING LOT SECTION PERLDTLINFILTRATION BED PREPARED NTS MAXIMUM SEASONAL GROUNDWATER DESIGN U W (n 86 i� Q LJJ 0 0 N 0 W N Z W W W o � C) C. C) a Fro C. o p Z U U U W a m a 0 L0 a Z ME.P4 PO ZF WASl G ,p 43211'b�' Fc�STE�F' \*6 LIONAL E�' WIDTH PER STD SPECIFICATIONS ELEVATION AT 54.1' (PER PANGEO INCORPORATED) DATE 09.11.08 UTILITY CONFLICT NOTE: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES, WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-5555 AND RECORD DRAWING CERTIFICATION THESE DRAWINGS CONFORM TO THE ONSTRUCTION RECORDS. PROJECT REF: FAC08-0024 ��S ? � ��9, THESE PLANS ARE APPROVED FOR CONFORMANCE WITH THE CITY OF AUBURN'$ ENGINEERING DIVISION REQUIREMENTS DRAWN KWT CHECKED AEP THEN POTHOLING ALL EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT RUPERT ENGINEERING, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. BY; _ DATE: A/�k TITLE/POSITION: C0 1AeArAf /L. . ry, CONFIRMED BY CITY: DATE: r h APPROVED BY: DATE APPROVED: JOB No. 08105 SHEET NO. C4 SHEET 4 OF 7 l 0 D z0/6 DECIDUOUS TREE #1 CHAINLOCK, LOCK 4 STAPLE TO STAKE (2) 2x2 FIR STAKES DRIVEN TO REFUSAL SET PLUMB $ IN LINE 2" LAYER BARK MULCH 2" 015HED EDGE PULL BACK BURLAP AND REMOVE WiRE BASKET 50/50 TOPSOIL/ NATIVE 501L MIX NT PIT 3 TIMES )TBALL DiAM. AT TOP I ►^ilc:E AT BOTTOM TREE STAK I NC, DETAIL N.T.5. CD �V Pk NT PIT 3 TIMES >TBALL DIAM. AT TOP :E AT BOTTOM 2" LAYER BARK 2" 015HED EDGE FOLD BACK TOP THIRD OF BURLAP 50/50 TOPSOIL/ NATIVE 501L MIX SHRUB PLANTING DETAIL N.T.5. INS CID 1 /01 1 X') I �N GD I AY11141 '1 ENCL GARB %D E%3 9 CD 12 1 i3 1 14 PARCEL NUMBER 5125400355 ��. PERVIOUS CONCRETE ---� 1: 6 I 7 A CD 00 PLANT PIT 5 TIMES ROOTBALL DIAM. AT TOP TWICE AT BOTTOM. IIIII CONIFEROUS TREE ...,,.,IIIII III I1111�' �IIIIIIIIIIII ,I i , �� II 2x2 FIR TREE STAKE �nIIIIIIIIIIIIIIIIIIIII �IIIIIIII 1 CHAINLOCK, LOCK 11 I1111I11111", 4 STAPLE TO STAKE Ii11I1111.,,,,,i III II iI IIIIIIIIiIIIIIIIIin� 2" BARK MULCH ���snl��Ilnllll I 2" DISHED EDGE UNFOLD TOP THIRD OF BURLAP $ REMOVE WIRE BASKET 50/50 TOPSOIL/ NATIVE SOIL MIX CONIFEROUS TREE STAK I N6 N.T.S. &'-0' WOOD FENCE LANDSCAPE PLAN N0T� COMPLY WITH ALL G I TY ORDINANCES AND OBTAIN ALL REC: U I RED PERMITS AND I NSPEGT I ONS MIX ORGAN I G COMPOST WITH STOGKP I LED TOPSOIL AT A FATE OF I G .Y GOMPOST TO 5 G.Y. TOPSOIL INSTALL 5" BARK MULCH IN ALL PLANT BEDS PROVIDE ONE YEAR WRITTEN WARRANTY FOR ALL MATERIALS AND LABOR INSTALL AUTOMATIC, IRRIGATION AS PER PLAN NO SUBSTITUTIONS WITHOUT WRITTEN CONSENT OF LANDSGAfiz'E ARCH I TEGT AND G I TY REPAIR OR REPLAGE ANY DAMAGE TO UTILITIES OR FACILITIES TO OWNERS SATISFAGTION LOCATE AND PROTECT ALL UNDERGROUND UTILITIES TILL ALL ON51TE COMPOST SOIL MIX TO 18" DEPTH. ONCE PLACED DEG I DUOUS TREE GAL I PER MEASURED AT 4.5' MINI MUM ABOVE ROOT BALL. CONIFEROUS TREE HT MEASURED FROM TOP OF GROUND AT TIME OF PLANTING. INSTALL ROOT BARRIER WHERE TREES ARE WITHIN 8' OF PAVED `,,REA5 PROVIDE SOIL FERTILITY ANALYSIS AND ADD FERTILIZER AND OTHER NUTRIENTS TO MATCH RECOMMENDATIONS REMOVE ALL ROCKS AND DEBRIS OVER 4" FROM TOPSOIL MIX LA N HYDROSEED M X LAWN SEED SHALL BE "EGO -LAWN" SEED AS SUPPLIED BY WILOFLONER FARM I0I115 HWY 12 W. , RR#2 COLDWATER, ONTARIO LOK IEO pH: 566-476-1455 SEED RATE WILL BE 5LB/1,000 5.F. WITH FERTILIZER AND MULGH FATE AS PER SPEGIFIGATiONS SECTION 5.08. PLANT LIST 31th Street N.W. r SITE 8 5t. NF 'O 26th St. NE hst- NE ' 23rd Street N.E. y 15th Street 15th Street N.E N VICINITY MAP SCALE- N.T.S. ACER RUBRUM 'ARMSTRON6' - ARMSTRON6 MAPLE 2" GAL. B$ B A5 SHOWN THUJA PL I GATA - REDCEDAR 6-S' HT. B $ B AS SHOWN i PINUS CONTORTA - SHORE PINE 6-5' HT. B$ B AS SHOWN Q rrl r GINKGO B i LOBA 'AUTUMN GOLD" - AUTUMN GOLD GINKGO 2" GAL. B $ B AS SHOWN BERBERI5 DARWINI - DARWIN5 BARBERRY 5 GAL. 4' O.G. MAHONIA AOUIFOLiUM - ORE60N6RAPE 5 GAL. 4' O.G. THUJA PYRAMIDALIS '5MA6ARD' - EMERALD GREEN ARBORVITAE (o-7' HT. B$ B 5' O.C. 0 THUJA PYRAMIDALIS 'SMA6ARD' - EMERALD GREEN ARBORVITAE 5-6' HT. 13413, 5' O.G. 0 CHOISYA TERNATA 'AZTEG PEARL'- AZTEG PEARL MEXICAN ORANGE 5 GAL. 4' O.G. 0 VIBURNUM TINUS 'SPRING BOUQUET' - SPRING BOUQUET LAURESTiNU5 VIBURNUM 5 GAL. 4" O.G. 6) PRUNUS LAUR. 'OTTO LUYKEN' - OTTO LUYKEN LAUREL 5 GAL. 4' O.G. C SYRIN&A VULGARiS - LILAC 5 GAL. AS SHOWN MYRICA CALIFORNICA - WAX MYRTLE 5 6AL. AS SHOWN VIBURNUM DAVIDI - DAVID VIBURNUM 5 GAL. 4' O.G. FUJ I APPLE ESPALL I ER ATTACHED TO FENCE ® 6' BENCH C6 CEANOTHUS 6LORIOSUS 'PT REYES - PT REYES GEANOTHUS i GAL. 5' O.G. GO COTONEASTER DAMERI - BEARBERRY COTONEASTER i 6AL. 5' O.G. AR AJU6A REPTANS - AJUGA 4" POTS 15" O.G. LOCATE AS NOTED LAWN HYDR05EED "EGO -LAWN" SEED AT A RATE OF 5 LB./1,000 S.F. AND 1,500 LB. FIBER PER ACRE, GUARANTEE 100% COVERAGE WITHIN ONE YEAR 2 $ 5 MAN GRANITE BOULDERS IN FERN GARDEN LOCATE AS INDICATED FERN GARDEN FLANTS DEER FERN, ROYAL FERN, SWORD FERN, JAPANESE TASSEL FERN, LICORICE FERN PLANT 16AL SIZE E16HT OF EACH VARIETY IN FERN GARDEN AREA INSTALL 5-8" ROUND GRANITE RIVER ROCK AT BASE OF ALL BERMS $ 5" ORGAN I G COMPOST AS MULCH OVER ALL BERMS HERE3 GARDEN PLANTS BASIL, CHIVES, TARRAGON, OREGANO, PARSLEY, ROSEMARY $ THYME PLANT I GAL 51ZE ONE OF EACH VARIETY IN HERB GARDEN AREA FD�ENN I AL VEGETABLE PLANTS ANISE, DILL, MINT, ASPARAGUS, ELEPHANT EARL I C, RHUBARB, SWEET POTATO $ YAM PLANT ONE OF EACH VARIETY SIZE AS AVAILABLE IN PERENNIAL GARDEN AREA PROJECT REFERENCE: FAGOS-0024 This plan sheet reflects the city of Auburn's minimum landscape requirements. r�e�qatu APPROVED Bpi': >9 P-A DATE APPROVED. - 3 0 CAR ___JL/ Record Drawing Certification STATE OF • -" N WASHINGTON These drawing c�lform to t e Contractors REGISTERED Construction Records. LANDSCAPE ARCHITECT ----� Bi: DATE: DAVID B.• LOWMAN CERTIFICATE NO. 387 Title%coition:. Confirmed by City Lam' DATE: z a 11­� [� C\2 z o o U f� co w LO� nz 'Q 03 A v� A ­11 P4 REVISION PER CITY 12-q-05 REVISION PER CITY :2-26-Oq REVISION PER CITY 6--22-Oq REVISION PER CITY -1-07-Oq F'EVISION PER CITY -1-23-Oq ►Rl"t o� 7 IODA0/G NOTES DE516N BASED ON 20 GPM @ 60 P51 MIN. IF LE55 FOUND, CONTACT LANDSCAPE ARCHITECT BEFORE INSTALLATION. PROVIDE ALL PERMITS AND INSPECTIONS. PROVIDE ONE YEAR WRITTEN WARRANTY ON ALL PARTS AND LABOR. NO SUBSTITUTIONS. PLAN 15 DIA6RAMATIC AND ACTUAL FIELD LAYOUT 15 THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR 15 TO PROVIDE MAINTENANCE AND OPERATION MANUALS TO OWNER AT FINAL WALK THRU. CONTRACTOR 15 TO PROVIDE TIME OF OPERATION CALCULATIONS FOR MAY THRU OCTOBER TO PROVIDE A MAXIMUM OF I" PER WEEK TOTAL PRECIPITATION FROM COMBINED WEATHER AND IRRIGATION. INSTALL RAIN SENSOR IN SECURE BUILDING LOCATION TO SHUT OFF IRRIGATION DURING WET PERIODS. CONTRACTOR SHALL MONITOR THE IRRIGATION SYSTEM AND ADJUST CONTROLLER TIMING TO REFLECT CLIMATIC AND WEATHER GHAN6E5 AT LEAST ONCE PER MONTH DURING FIRST 5EA50N OF OPERATION TO INSURE OVERWATERIN6 OR UNDERWATERIN6 15 NOT OCCURRING AND THAT NO OVER51FRAY ON PAVING OCCURS. ALL PIPE OR WIRE UNDER PAVING SHALL BE IN 5CH40 PVC SLEEVE AT LEAST 16" DEEP AND TWICE DIAM. OF INSERT PIPE. MEET ALL CODES PERTAINING TO ALL ASPECTS OF THE IRRIGATION SYSTEM. ANY DAMAGE TO FACILITIES OF UTILITIES WILL BE REPAIRED OR REPLACED TO OWNERS SATISFACTION, CALL BEFORE YOU 0161 LOCATE ALL UNDERGROUND FEATURE5 BEFORE TRENCHING. FIFE 5IZINO PIPE5 TO BE 51ZED ACCORDING TO THE FOLLOWING TABLE: 0-10 GPM = 5/4" PIPE II-18 GPM = I" PIPE 11-25 GPM = 1 1/4" PIPE 26-54 GPM = 1 1/2" PIPE 56-55 GPM = 2" PIPE ALL PIPE SIZING 15 BASED ON OL200 PVC, PIPE CONTRACTOR TO DETERMINE PPE 5IZE5 PER THE ABOVE CHART. r'K114H GRAI)E/TOP OF MULCH -UP SPRAY OR ROTOR SPRINKLER: RLEX STREET ELL 5 PIPE RISER ASSEMBLY: RB ELLS ANS 12' SWING PIPE LATERAL PIPE .� SCH 40 TEE OR ELL POP-UP SPRAT' OR ROTOR SPRINKLER DETAIL 30-INCH LENGTH OF WIRE, COILED COILED WATER PROOF CONNECTION (1 OF 2) VALVE BOX WITH COVER: 12-INCH SIZE FINISH GRADE/TOP OF MULCH REMOTE CONTROL VALVE: PVC SCH 80 NIPPLE (3") PVC SCH 40 ELL PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) PVC SCH 40 MALE ADAPTER PVC SCH 40 TEE OR ELL PVC MAINLINE PIPE RE1„IOTE CONTROL. VALVE DETAIL NOTE: PROVIDE QUICK COUPLER KEY & HOSE SWIVEL TO FIT QUICK COUPLER Lli FINISH GRADE/TOP OF MULCH QUICK -COUPLING VALVE: 10" VALVE PIT 3" NIPL. �3-INCH MINIMUM DEPTH 3/4-INCH WASHED GRAVEL GALV. STREET ELL —CONC. BRICK GALV. 12" NIPL. _—GALV. STREET ELL PVC SCH 40 TEE OR ELL PVC MAINLINE PIPE I \_ \\-- - GALV. ELL #4 REBAR W/ S.S. PIPE CLAMPS OU I CK- COUPL INCH VALVE IRRIGATION PLAN 10 STATE OF WASHINGTON REGISTERED LANDSCAPE ARCHITECT DAVID B. LOWMAN 15th CERTIFICATE NO. 387 31th Street N.U1 W z SITE 26th St. N.E 23rd Street N.E. ZO Street 15th Street NE MAP I=INI!5H SFAi PVC, SCH 40 ELL FVC SCH aO NI('P'LE (I. EN6TH AS PEOVIRM, I OF :2,) SO-tP"H LINV.lkR LEN&TH OF k`;l, d C IL.Fl7 YlATERfPZ -_--r CONNECTION; 10 TA& RAIN BIPD VIP SERUEr-, VAN-VE volt' 141714 colli -P, PVC SCH 40 F-1 ALE A1,i;AM ER TQNFM_0�2" 1BRIGK (I OF 4) 3 Itk!H "NIPVM GLF 1T! c P 3/4-ItdC;ti N?r� ti6�R,YI'.L Ci T`.rRc L Z01le KIT FAIN 151IRD XC • 0'7S-f-'RF-P3F° tP 4l,T> Lr-,/_o'5 VAL1--IE, BAC-K FLMH PRESWRE n-17- ILAaTIN FILTER{, TRICKLE CONTROL VALVE N/ BACK FLUSH FILTER CAP: POLYETItr"I..LNI~ 0*71RIFUTION T1,"Ns i-AIN DIRT % OR Vffrl- i.Ii5lPIFWI0N TIJ311`46 RAIN BIID rl' -025 (Tif"IG.A,1.? rcr OFavL.cfi -IFIN1I N1 TR�APE -t'PJL.TI OVILET EIMIT I[FIR, RAIN BIRD XERI-1 Xe-10' b --v2--w.H roLYETiI i-Em,. C'IF='C; RAIN FIRD X55 BLACK S'TIRIFE T1131f0v car- &RA v'E. f3;.- R 3E-r) MULTI -OUTLET EMITTER IN 6" PI`!' 114-INCH TUBING: POLYETHYLENE DISTRIBUTIONTUBING RAIN BIRO P F-025 OR VINYL DISTRIBU`NION'TUBING RAIN BIRD DT 025 (TYPICAL) SINGLE OUTLET EMITTER: RAIN BIRD XERI-BUG EMITTER XB--XXPC OR PRESSURE COMPENSATING MODULE PC-XX WI'I H DiFPUSER CAP DBC-025 _.._..__.. 1/4-IhdOIIBARB"iRAIJSFER'TEE: RAIN BIRD XBF31EE 1/4-INCH TUBING STAVtE: RAIN BIRD TS 025 `� - -- lf2-INCH POLYETHYLENE TUBIN(k NOTE: RAIN BIRD XBS 81_ACK STRIPE TUBING USE XERIMAN TOOL XM-TOOL TO INSERT CONNECTOR DIRECTLY INTO 112-INCH POLYETHYLENE TUBING, EMITTERS AROUND PLANT ON 1/4 INCH TUBING IRS OATION LEOEND Q RAINBIRD 1800 POP-UP ON SWING PIPE RISER RAINBIRD 100-FEB CONTROL VALVE PER DETAIL Fc] RAINBIRD ESP CONTROLLERS, WALL MOUNT, ONE FOR Q RAINBIRD 55 LVC OUIGK COUPLER, 55K � 5H-0 _ N I" FEBCO 850 DCV IN JUMBO BOX I" CRANE GATE VALVE A5 IRR. P.O.G. I" CRANE GATE VALVE AS IRR. P.O.G. 0 5/4" H05E BIB ON 4x4 POST W/ 5TL. RISER. 1 1/2" 5CH40 PVC, MAIN AT 18" DEPTH MIN. GLASS 200 PVC LATERALS AT 12" DEPTH MIN. Iv co z a� w � O N co J � 0 O � A to Ia .A) N ':3 C o� 71 REVISIONS r r_t c i D Lo r 10 23rd W z SITE 8, 26th St. NE I Street NE N VICINITY MAP SCALE- N.T.S. v A ct r o rTl ® tj rpl woo 1 i1®1 4� ,w 00 1 w 0 o L_ c~i� =j= w = is L) Y a Ca V) r, z --- O, z wQ LU uj > do 0- z F-Z m Q� - ,o m Q co 1►\ '1V ARCHITECTS PLANNERS JOB NUMBER- 01-11 DATE 06 -10-09 9\t1v3, LA, STUDY FOR SIGHT LINE PER HEARING EXAMINER FOR SGREEN VISION PLANTING SHEET Al _ OF 07 /oDAO/b