HomeMy WebLinkAbout09D1972T" 0 CONSULTANTS QMML Andrey Ivantsov 2 W Main Steet Auburn, WA 98001 (253) 881-8181 ARCHITECT: The Kelmig Associates 216 A Street N.W. Auburn, WA 98001 (253) 939-3232 Fax: (253) 135-1309 STRIJCayRAL ENGMEER: SEGA Engineers 22939 BE 292nd Place Black Diamond, WA 98010 (3(00) 886-1011 Fax. (360) 886-1016 CIVIL ENGINEER Anstey Engineering Benjamin P. Anstey, P.E. 8621 NE 180th St. Bothell, WA 98011 (20(o) 303-1639 PROJECT DATA PROJECT LOCATION: 615 C STREET SW agSIE4SOR PARCEL *�a 1321049046 Auburn, WA 98001 FROJEC DESCRIPTION C-3 - HEAVY COMMERCIAL LANDSCAPE ARCHITECT TECT SELECTIVE DEMOLITION TO THE EXISTING BUILDING SETBACKS: David Lowman WILL BE DONE TO REMOVE ANY TOXIC MATERIALS AND FRONT: 20 feet Eagle Design, Inc. PREPARE THE BUILDING FOR AN ADDITION. A TWO (2) SIDE, INTERIOR: None 5561 S Holly St. STORY ADDITION WILL. BE CONSTRUCTED AROUND SIDE, STREET: 15 feet Seattle, WA 98118 THE EXISTING BUILDING TO PROVIDE ALL AMENITIES REAR: None l20(o) 811-1614 NECESSARY FOR THE MARVEL DELI'$ GROWING FAX (206) 611-1614 BUSINESS. THE SITE POST NEW CONSTRUCTION LANDSCAPING: GENERAL CONTRACTOR WILL BE 95Z% IMPERI/IOUB AND 42% PERVIOUS Street: 5' Type III AND THE BUILDING WILL TOTAL 16,518 F. SURVEY STANDARD BENCHMARK - NAVE) 88 BENCHMARK TAKEN FRON 03H MONUMENT AT 15TH STREET SW AND C STREET SW SURVEYOR: ELEV. 89.95' Warren T. Lay 104 Cedar Dr. SE SURVEY BY Auburn, WA 98002 WARREN T. LAY (253) 833449 104 CEDAR DR SE Fax: (253) 833-0192 AUBURN, WA 98002 PHONE: 253-833-114S PARKING ANALYSIS: SITE AREA: Other Retail Establishments - I per 500 at TOTAL SITE 9,380 OF = 19 spaces 11EXI$TING IMPERVIOUS Storage Up to 20,000 sq - I per 2,000 sq, ft, (3 min) 4,482 or = 3 spaces BUILDING FOOTPRINT Office - I per 300 sq rt PARKING ASPHALT 1,016 or = 4 spaces PARKING GRAVEL Restaurant- I per 100 sq ft 532 or = 5 spaces TOTAL PARKING AREA AREA/REQUIRED ROUND OFF PER 1852.10 9380/ 500 = 16.16 19 3 per 20,000 3 1016 / 300 = 358 4 532 / 100 = 532 5 31 REQUIRED PARKING TOTAL IMPERVIOUS NEW IMPERVIOUS BUILDING FOOTPRINT LANDSCAPING PARKING Total Required Parking 31 spaces IMPERVIOUS AREA Total Parking Provided 32 spaces Compact = 1 spaces (1 / 32 =21.81%). 3 Accessible parking spaces provided 2 Accessible Van space provided DRAWING INDEX 43fo50 or (l ac) FACILITIES SHEETS F-I SITE PLAN F-2 SITE SURVEY EXISTING 4,691 SF F-3 EROSION PLAN 10.1% F-4 UTILITIES PLAN 14,352 SF F-5 GRADING PLAN 16,100 SF LANDSCAPE 30,452 SF L-I LANDSCAPE PLAN 69Bge L-2 IRRIGATION PLAN 35,149 SF 805% 29.190 2183 SF 5.0ge 28,943 SF 663go 41,V13 SF 95•Sq° ICC/ANSI A111.1-2003 502B FLOOR SUWACES. PARKING SPACES AND ACCESS AISLES SHALL HAVE SURFACE SLOPES NOT STEEPER THAN 1:48. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING SPACES THEY SERVE. ;NOTE ROUGH GRADIf iG ,AND KEYSTONE WALL CONSTRUCTION COMPLETED UP IDER SEPARATE PERMIT EARTHWORK: CUT=803 CY FILL=118 CY NET = 118 CY PROPERTY PARCEL" KEYSTONE CORNER 132104SO20 RECENTLY COMPLETED WALL ENDS ZONE-C 'NO PARKING' AND 'FIRELINE' MARKINGS KEY STONE WALL TOP 81' MAX �' �. ... CJ 8� ° :_ 13 3r- A PER CITY OF AUBURN STANDARD DETAILS WITH +3'-6' CHAIN PROPERTY ELEVATION — .� �,. SIGN 'ONE WA)'' CORNER LINK FENCE GENERAL NOTES: DO NOT ENTER 1. THIS DEVELOPMENT PROJECT SHALL CONFORM TO THE CITY OF RECENTLY COMPLETED co �>.2 \' PLANT KEY STONE WALL ►n AUBURN'S REQUIREMENTS AND BE IN ACCORDANCE WITH THE APPROPRIATE - WAY — -� ""�► 0 F z � AREA ---- PLANS. ANY CHANGES FROM THE APPROVED PLAN WILL REQUIRE APPROVAL WITH +3'-6 CHAIN -- - ---- . -- LINK FENCE � ONLY _ � •.<m� 15 a'+ i� _._.._ _ gar , a!�;e ���. �, � � m - NEW SIDEWALK -. , 17� �. q 0 0 ± z FROM THE OWNER, ENGINEER, AND THE CITY. +� ` I w _ I - 5 r 6' 2. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE 'WASHINGTON a - - ,s� 2 3 I 4 '"ns,; �LOA iN6 "4 I 1 7L STATE DEPARTMENT OF TRANSPORTATION (WSDOT) STANDARD PAR4EL�"�'�;a iRe 8 -0 3 SP • 9'-21- SPCs+ 8' 6' SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION 132 0 91 _ i;% ,f (2002/LATE5T EDITION), EXCEPT WHERE SUPPLEMENTED OR MODIFIED BY THE ZONE-C �4� ` v' CITY'S CONSTRUCTION STANDARDS MANUAL. COPIES OF THE ABOVE PLANTING DOCUMENTS SHALL BE AVAILABLE AT THE JOB SITE DURING CONSTRUCTION.cYl N 1►- AREA 123 SF 6� AREA 100 SF " 0 `� 1 3. A PRE -CONSTRUCTION MEETING SHALL BE REQUIRED PRIOR TO THE START OF -a� \ ! UL E ALL CONSTRUCTION. CONTACT THE PUBLIC WORKS DEPARTMENT AT co `s ___. 19'-0' BUILDING ADD�TQy EXISTING BUILDINGUl 253-931-3010 TO SCHEDULE A MEETING. ' FINISH FLOOR ELEV 81.0 FINISH FLOOR ELEV 81Id��� 6 ��.: ; _t3' yy -- — fL I - _ ' e 1321049046 1� in 24'-2%�cn 4. LOCATIONS SHOWN FOR EXISTING UTILITIES ARE APPROXIMATE. THE m 4 _ _ , -0, - e 1 8 9 V Ri INK 1 CONTRACTOR IS CAUTIONED THAT OVERHEAD UTILITY LINES MAY NOT BE 1 SHOWN ON THE DRAWINGS. IT SHALL BE THE CONTRACTORS RESPONSIBILITY 0 B� TO DETERMINE THE TRUE ELEVATIONS AND LOCATIONS OF ALL UNDERGROUND UTILITY LINES. IDENTIFICATION, LOCATION, MARKINGS, AND RESPONSIBILITY FOR, UNDERGROUND FACILITIES OR UTILITIES, IS GOVERNED777��i BY THE PROVISIONS OF CHAPTER 19.122 REVISED CODE OF WASHINGTON 1� +� (RCW). PRIOR TO STARTING CONSTRUCTION THE CONTRACTOR SHALL CALL 1-.,- I ! I ONE CALL C-0-425-5555) FOR UTILITY LOCATIONS (WATER, SANITARY - ■ j, , I �= n WB-40 801 - SEWER, STORM A SEWER, GAS, POWER, TELEPHONE, AND TELEVISION. ,�`; PL T1N102 ❑ 9O 13, y 14 g L II \ 1 �Ik`t ■ f, i�,' m I 25 NEW SIDEWALK LAWN ONLY N �- Q' t, r . /� ; _ I 5. PRIOR TO THE START OF CONSTRUCTION A PROPOSED ROUTE AND SCHEDULE FLANTI G 61 _ 333 SF ` I 16 11 U Vag A SUBMITTED TO THE CITY FOR 102 SF - r, 15la FOR HAULING MATERIAL 70 THE SITE SHALL BE =� � _ NEW SIDE A K APPROVAL. IF THE CITY BELIEVES THAT THE HAUL ROUTE WILL ADVERSELY I �,� - - - - - - - - - - - - - - - - 120'-0'p"- -0' 8'-0' 3 S ACES 6 9' = 21' 6' 9' 12-G. X12- '� B IMPACT THE STREET NETWORK, HAULING, MAY BE LIMITED TO APPROPRIATE S(;REEN 61 '�CxAIEBAGE AND FIRE OFF-PEAK HOURS OR ALTERNATE ROUTES AF?BAG i _� -+RUCK' URNING RADIUS � � � RECENTLY LETED 98'-5%' ?i KEY STONE WALL 6. THE CONT-. 4CTOR SHALL BE RESPONSIBLE FOR PUBLIC SAFETY ON AND PROPE Y - + �` ° TN +3'-6" CHAIN ° X ao AROUND THIS PROJECT. PRIOR TO THE START OF WORK, ALL METHODS ANILI D - -. CEO^rt per 25' 0' EQUIPMENT USED FOR TRAFFIC CONTROL AND STREET MAINTENANCE SHALL LINK FEN N 87 ° 17' 1 363.3-1' f r,x - 38'-0' %4'-0' _I BE SUBMITTED TO THE CITY FOR APPROVAL, CONTRACTORS AND THEIR ly SURETY SHALL BE LIABLE FOR INJURIES AND DAMAGES TO PERSONS AND I II y EXISTING •..._ ANTINCy� GARBAGE PROPERTY SUFFERED BECAUSE OF CONTRACTORS OPERATIONS OR NEGLIGENCE CONNECTED WITH THEM. PROPERTY 1. ALL CONSTRUCTION SURVEYING FOR EXTENSIONS OF PUBLIC FACILITIES _ _ COINER SHALL BE DONE UNDER THE DIRECTION OF A WASHINGTON LICENSE LAND _ EXISTING�UILDING SURVEYOR OR A WASHINGTON LICENSED PROFESSIONAL CIVIL ENGINEER NO CHANGE 'NO LEFT 'tU ' 8. CERTIFIED DRAWINGS ARE REQUIRED PRIOR TO PROJECT ACCEPTANCE 13 SPACES 1321049041 _ - �12 PACES REFER TO THE CITY'S RECORD CONSTRUCTION DOCUMENT HANDOUT EXISTING SITE ZONED FOR C3 EX STING I 9. ADDITIONAL PERMITS REQUIRED FROM CITY OF AUBURN: STORM FERMI z CONSTRUCTION PERMIT, SEWER PERMIT. `- N X _._ 4 SPACES M w EXISTING w w i ,ALL SIGNIFICANT TREES ON SITE ARE TO BE REMOVED. U - I=XISfiI PARKIi� 3 SPACES, EXISTIN o- i I SPAC S 0111 DRVE THROUGH _ I EXISTING 3 SPACES e_ I EXISTING 34 '"PACES �� �� � ��� � —� ��� �� � �� �.�� �� .� �� �. �.�. ��� ten•-. -,^n�w�� s .� �� EX. DRIVE EX. WALK NO CHANGE EX. DRIVE EX. WALK NO CHANGE � ~ —PAINT LINE — - ---- �------------------------- w — — — — — — — — — — — — — — — — — - t 8TH STREET SW ----------- ------ ---------------- — — — — — — -D A c~oCENTER LINE 5� - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --- - : WM GaN R tsoN o� T �1G'cEtS�S To P�1PA64 ----------------- - 13240"t*? CAAf rl- sE -STARnIP wvT=c .341cH wr T2Aa AS !� OVJ✓6R VVMueISTRMr>FS TMe ftJtr7r_#C ? RECORD DRAWING C E RT I F I CAT I O N THESE DRAWINGS CONFORM TO THE PROMR77W. TR A cRW Adair; ACRIMA&VT Z ANT CONTRACTOR'S CONSTRUCTION RECORDS. PROYTii+fD/ FLAN WN4. WefiW TO BE RpVZNO "M 481W* ' TM! IDS p►Ts lb ftA&1G 13Z/04go7. BY• DATE: NOTE: C riLL 1-800-424-5555 BEFORE YOU DIG TITLE/POSITION: off' 7-7-011 ONFIRMED BY CITY: DATE: O W O r- i V) u � 00 V-�- a V) Q �i Z 00 Q - cc, ctf iz p 3: n. ro ::D t.r , z Q CV Q F- z w J U I �. 9 0 C 0 W C (J_ L .J ?� _J V LLJ — U W Q c0 ; O 0- jl I E O I � U I I (_0 (D i- N, v�oo I 00 � r(,) I@� c0 (D 4_ 00 V) 00 Q c� CD ^ c a I w N a� - LLJ z _J N I N F- m O X � Q 00 0- W SITE LAN SCALIF- 1-20 I W — � ROJECT REF: FAC08-0017 W HESE PLANS ARE APPROVED- FOP, ONFORMANCE WITH THE'CITY OF AUBU',N'S m — NGINEERING DIVISION i2EG:�112EME°JTS. UJ z Q w Q z PPRRVED BY: A LLJ ,ATE APPROVED: 09D)`97X r a0 0 W a LEGEND DECIDUOUS TREES o CONIFER TREES IRRIGATION METER F CATCH BASIN LIGHT POLE 0 PHONE R15ER FIRE HYDRANT UTILITY POLE -0- WATER METER EB STREET LIGHTING BOX MANHOLE 0 NEW KEYSTONE _o----o—o 0 0-0- WALL PROPERTY LINE EXISTING WATER W— MAIN LINE —W_ __W— —ILL- NEW WATER MAIN LINE " M ■ k M M x M--� +�- TIGHT LINE 6' - ---TI— —TI-- —TI_— TL SANITARY SEWER LINE ----- — TOPO LINE — EXISTING 5 tiJ>�R E S MENT EXISTI 1I I WAT : 1 EAS ENT I PARCEL * CATCH BASIN IB2104SMO OUT TO NORTH 12' STEEL INV = 54,03 ZONE - C-3 NEW 12' DI TO SW I PR PI�RTI1' cb"� INV = 84.03 1 I Cof NItR 1 ___ 1 1 _ e2. Ico ' 83.3 y`� 82.3 , ' i 4D 1� N 89' 10, 53, W 10.06' ! ,' I 1 —� 1— — = '� I N87°17'18V 355.44' EXISTING ;.� _-- I I 1 .. I .0 -3 . EASEMENT " _ MH I ..�'< �. CHAIN LINK FENCE , ..I;.� w (� _ IN F OM EA5 OUT �I 1 TO NORTH I)IV AT -- CTR BASII�j= 5.91 I T E°, I 85.51` a_ 1 CONIFER, ' ,� $�1 RIB I I I Lc I If3.9 - ; 86- 3/4' WATER PARCEL «I I ' F------- ASPHALT�METER ----------'1304SI13 tJ _ ZONE - CjEXI5 NG I 1 1 ! t>J I /� u r ! 18F�.1 ATE O U r �UJA5 EN7 I ua I r' i -- tl3" EXISTING i. • �� -a = An CONCRETE I I I z �? I EXISTING , I I jJ -W`y 1 - Z I ;` �/GRAVEL PARKING/�� _ EXISTING BUILDING co a RN. FLR. ELEV. 87.0' 86.5' FOR BUILDING PAD PARCEL � f• . I 1321049046 O _ 184.3 SPTIC TANK TO BE ABANDONED N 64.1. 1 I PbR KING COUNTY HEALTH f' �26°-0' 51 _ I Dtf?ARTMENT CODES '` r 33 -0 8 i SEPT,�qE IS TO BE REMOVED FROM I SEPTIC T�NK BY AN APPROVED 1 i 945 PUMPER ME TANK VOID 15 TO 1 C. 184.4 BE FILLED WITH COMPACTED AGGREGA�- ® -% - - - - - - - -a s - - - - - - DECIDUOUS 4 - TREES i AND THE BOTTOM OF THE TANK I , ,., WILL BE PUNCTURED FOR DRAINAGE ; I Q :' P40NC) PURPOSES TO PREVENT THE SEPTIC TANK � ro � 842 P055115I1 ITY OF FILLING c JOB VERIFY V ROCKERY Qi II i -' I IE I PLANTER ' Q PLANTE� D ! 56,"I _ i o OXi i p Di I I I l 86 85.E t m III i 3 m, �1I M. EX CATC� `'ra/ ASPHALT,BASIN NEW 12'� � OUT TO NE cra 1 o' IE=8424It 11 I l e I N 64' 41' 58' E 10.�0' Cr-muOWER �'a , TANK LOCATION ��/ ASPHALT i'�_y CHAIN LINK + FENCE } _ ;�I,X CHAIN LINK FENCE 35-__--- _-.__--_--_---_._..___f' - - _ _ _ frf, - j S8 7'181 / f f PARCEL "� 186,4 TRANSFORME ` 132104W41 ;a f< ZONE - C-3 EXISTING NEIGHBOR BUILDING PUGET SOUND POWER AND LIGHT COMPANY - EASEMENT BEGINNING TAT HTE SOUTHEAST CORNER OF SAID PROPERT, THENCE NORTH 03'54'36' WENT ALONG THE EAST LINE OF SAID PROPERTY A DISTANCE OF 34.0 FEET. THENCE CONTINUOING ALONG SAID EAST LINE NORTH 0512'02' WEST A DISTANCE OF 85.45 FEET TO THE NORTH LINE OF SAID PROPERTY: THENCE NORTH 89'10'53' WEST ALONG SAID NORTH LINE A DISTANCE OF 10.06 FEET. THENCE SOUTH 05'12'02' WEST PARALLEL WITH SAID EAST LINE A DISTANCE OF 86.50 FEET: THENCE SOUTH 02'54'36' EAST PARALLEL WITH SAID EAST LINE TO THE SOUTH LINE OF SAID PROPERTY THENCE SOUTH 89'10'53' EAST ALONG SAID LINE TO THE TRUE POINT OF BEGINNING. SURVEY PROVIDED BY WARREN T. LAY E 15TING D IVEWA I I NI .I I I CHAIN LINK_ FENCE I 81GN ON -- A 3' BY 3' CONCRETE; PAD SURVEY STANDARD BENCHMARK - NAVD 88 BENCHMARK TAKEN FROM 03H SURVEY BY WARRENT T. LAY 104 CEDAR DR SE AUBURN, WA 98002 PHONE: 253-033-1149 NOTE: CALL 1-800-424-5555 BEFORE YOU DIG IOPERT711 �ORNERjj p I z 1 LL, j III II I ua ills 1 I IZ I I 4 I (L II Iz I� E1� I Lu i�TAFII ! I 1 I I LINE ENTER it I I 1 , II i I cn 4PERTY QORNER II j 1 I I II I II I I II I I II I I II I I II I I EXISTING SURVEY SCALE RECORD DRAWING CERTIFICATION THESE DRAWINGS CONFORM TO THE CONTRACTOR'S CONSTRUCTION RECORDS. BY E DATE: '7"p TITLE/POSITION: CONFIRMED BY CITY: DATE: 0 PROJECT REF: FAC08-0017 THESE PLANS ARE APPROVED FOR CONFORMANCE WITH THE CITY OF AUBURN'S ENGINEERING DIVISION REQUIREMENTS. APPROVED BY: DATE APPROVED: w i o \ i cu N 0 C, o Q \ aI p W T W o [L 00 o Q m X fn W WW J of 4J inV) o 0 o Q v=i cn z 0 w CL w F— Q 0 I 13N o 0 ta•. v cu Q 0 W (� C/1 F w W 2 N N � O W W 000 00 V m 00 Q I 7- 00 Q 00 w z I z M N a NfL Q z w U (n O (/) O 00 O w LIL W Q U) ., LLI vI Z ry w Q I cD m Q 0 0 CL 0 U Qo 0 c_ U') O =3 cd) C) � O ff a� � 00QQoCD �-- O ^ C00 n N Ln L- 0) W _j " _n =z LLJ NI-0 coos X's Q �= 00 ML- I, LLJ C �) LL1 Ill / n LLJ r m —_ czz W (� ) a wCL Q L. LL1 r O i 00 O w Q PARCEL" 1321049020 ZONE - C-3 I II I I II I I II I I I II I I II I I II I I II I I II I II I I II I 1 I II I I I II I I II I I II I I II I I 11 I I II I I 1 I II I I II I II II I I II I I II I I I II I I II I 1 I II I I II I I II I I II I I u I I u I 1 I II I I II I I li I I U I I II I I II I I II I 1 I Il I I II I 1 I II I I U I I II I I II I I II I I II I I II I I II I I II I N87°17'18'W 355.44' I II I _ I II I ��NBTRIlCTI{�N:_: � I u I 16EE C.1TV DETAl j II II I II I I II I I II I I II I I II I dG ADDITION XK TING BUILDING FINISH FLOOR ELEV. 81.0'! I II PARCEL • ��ASPHALT�� a� II j 1NCx 132104W46 3 jj 'E PARKING �� c ► II I I n I I I II I PROVIDE CATCH BASIN PROTECTION i ii I PER ER06ION-04 I n I ! /LJLf r i _/L _L r, fLLLL LZLLLL/�LLL=/LLB_=LLL 13:�49041 ZONE - C-3 EXISTING N,=!GHBOR BUILDING PARCEL " 242104W65 IK i i li W d I II _ .� S8TfT18'� '�� j I II j II I II RI HT OFI AY I I1 I I II I II I II I Il I TEMPORARY ERROSION CONTROL PLA. SCALE 120 CITY OF AUBURN ER05ION CONTROL NOTES: I. WITHIN THE CITY OF AUBURN, ALL REQUIRED SEDIMENTATION AND EROSION CONTROL FACILITIES INDICATED ON THE PLANS MU;?,T BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR OTHER CONSTRUCTION ACTIVITIES THESE FACILITIES SHALL BE MAINTAINED AND UPGRADED IF NECESSARY TO INSURE THE SEDIMENT -LADEN WATER AN,L> STORM DRAINAGE RUNOFF DOES NOT IMPACT THE ADJACENT PROPERTIES, NATURAL DRAINAGE WAYS, OR THE EXISTING CITY STORM DRAINAGE SYSTEM. 2, THE SOURCES FOR ALL MATERIAL IMPORTED INTO THE SITE SHALL BE APPROVED BY THE CITY. 3. THE STORM DRAINAGE DETENTION (RETENTION IF INFILTRATION SYSTEM 15 USED), SEDIMENTATION AND EROSION CONTROL FACILITIES DEPICTED ON THE APPROVED DRAWINGS ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS, ADDITIONAL DRAINAGE AND EROSION CONTROL FACILITIES MAY BE REQUIRED AS 61TUATIoNS WARRANT DURING CONSTRUCTION. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT, AND ADDITIONS TO THESE CONTROL SYSTEMS SHALL BE THE RESPON° IBILITY OF THE PERMITTEE. 4. THE TEMPORARY EROSION CONTROL FACILITIES, INCLUDING ALL PERIMETER CONTROLS AND THE DETENTION (RETENTION IF INFILTRATION SYSTEM 15 USED) CONTROL PONDS, SHALL REMAIN IN PLACE UNTIL FINAL 61TE CONSTRUCTION IS COMPLETED. AFTER CITY APPROVAL_ THE CONTRACTOR WILL BE RESPONSIBLE FOR REMOVING ALL TEMPORAEi:Y FACILITIES, 5. THE CONTRACTOR WILL BE REQUIRED TO WATER THE SITE, AS NECESSARY, TO REDUCE DUST EMISSIONS AS A RESULT OF CONSTRUCTION ACTIVITY. THE CONTRACTOR SHALL SWEEP ALL AFFECTED PUBLIC ROADS, AS NECESSARY, TO REMOV= MATERIAL DEPOSITED AS A RESULT OF PROJECT CONSTRUCTION ACTIVITY. 6, ALL AREAS OF ACTIVE EARTHWORK WHICH HAVE THE. POTENTIAL FOR EROSION AND SEDIMENTATION IMPACT ON ADJACENT PROPERTIES, NATURAL DRAINAGE WAYS, CR THE EXISTING CITY STORM DRAINAGE SYSTEM MUST ME BE STABILIZED ACCORDING TO THE FOLLOWING 5CHEDULF: FROM APRIL I TO SEPTEMBER 30, AREAS AT FINAL GRADE AND TH05E THAT ARE SCEDULED TO REMAIN UNWORKED FOR MORE THAN THIRTY DAYS SHALL BE STABILIZED WITHIN TEN DAYS. FROM O:TOBER I TO MARCH 31, EARTHWORK ACTIVITIES SHALL BE CONDUCTED IN STAGES IN ORDER TO MINIMIZE EXP05URF. EXPOSED SOILS WITH AN AREA GREATER THAN 5.000 SQUARE FEET THAT ARE SCHEDULED TO REMAIN UNWORKED FOR MORE THAN 24 HOURS AND EXPOSED AREAS OF LESS THAN 5,000 SQUARE FEET THAT WILL REMAIN UNWORKED FOR MORE THAN SEVEN DAYS SHALL BE STABILIZED IMMEDIATELY. NOTE: CALL 1-800-424-5555 BEFORE YOU DIG RECORD DRAWING CERTIFICATION THESE DRAWINGS CONFORM TO THE CONTRACTOR'S CONSTRUCTION RECORDS. BY DATE:6 TITLE/POSITION: M/ CONFIRMED BY CITY: DATE: D' co n o \ I cd cu 0 o CDQ Q m CD P po 0\0 r, m L11 J m K 0 d i S p p 0 Q (n z O N w SV�13 N � o 3 QIJ F-1 C%1 w w F O F_ Qw w O N � 0 w o �- F-- w 00 00 ry Z 00 (n Q Q I > z 3: 00 Q OC` 0_ cl-- M _TF D Ln S z m C_ Q N Q z �i J U }j CN d w C- a p w L.L w .:L LAJ V) r M Q _D w O CL 0-) O r") U CD O C cf) CD O 00 0 Co + 00 C CD Q G CD ^ a W � N � zww _i N f- O X Q co O = Q 00 M 0- 1 W �-- z LU z PROJECT REF: FAC08-0017 f-- LU V.LJ THESE PLANS ARE APPROVED FOR CONFORMANCE WITH THE CITY OF AUBURN'S m — ENGINEERING DIVISION REQUIREMENTS.Ldz a °- ui Q z APPROVED BY: LLJ DATE APPROVED: o9D/97R C� co w <z r n-1 GENERAL FILL REQUIREMENTS 1. REMOVE TOP SIOL AND ALL ORGANIC MATERIALS FROM THE SURFACE OF THE SITE IN ALL AREAS TO BE FILLED 2. COMPACT THE EXISTING GROUND TO A FIRM AND UNYIELDING SURFACE AFTER STRIPPING OPERATION 3. PROVIDE FILL MATERIAL CONSISTING OF WELL -GRADED SAND AND GRAVEL WITH LESS THAN 5 PERCENT PASSING THE 0200 SIEVE BASED ON THAT FRACTION PASSING THE 3/4' SIEVE 4. COMPACT STRUCTURAL FILL IN PARKING LOT AREAS, DRIVES, AND AT THE BUILDING LOCATION TO SrA. IN NOT MORE THAN 8 INCH LIFTS. 5. IF PROLONGED DRY WEATHER OCCURES UP TO IM. FINES WILL BE ACCEPTABLE 6. IF WEATHER 15 NOT DRY MAXI LIH MOISTURE CONTENT 2 TO 4 PERCENT MAXIMUM ALLOWED 1. TYPICAL PARTIAL SIZES LONGER THAN 3 INCHES SHALL BE EXCLUDED FROM THE TOP FOOT OF FILL NOTHING LARGER THAN 6 INCH DIAMETER SHALL BE ACCEPTED. 8. COMPACT TO S5,% MDD THROUGHOUT AS INDEPENDENTLY TESTED BY VERIFICATION LABRITORY. CONSTRUCTION SEQUENCE: 1. ATTEND PRECON5TRUCTION MEETING WITH CITY AUBURN 2. CLEARING AND GRADING LIMITS ESTABLISHED PER GRADE 4 FILL PLAN BY ANSTEY ENGINEERING. CONTRACTOR SHALL OBTAIN A COPY OF APPROVED GRADING PLANS AT CITY OF AUBURN OR FROM ARCHITECT 3. CONTRACTOR SHALL VERIFY THAT ALL DITCHES AND 5WALE5 AS SHOWN BY THE GRADING PLANS ARE INSTALLED TO DIRECT ALL SURFACE WATER TO THE TEMPORARY SEDIMENT POND AS CLEARING AND GRADING PROCESS. NO UNCONTROLLED SURFACE WATER SHALL BE ALLOWED TO LEAVE THE SITE AT ANY TIME DURING THE GRADING OPERATIONS. 4. FILL AND GRADE SITE 5. REMOVE/ABANDON EX. STRUCTURES 4 UTILITIES AS REQUIRED. 6, REMOVE EROSION 4 SEDIMENTATION CONTROL MEASURES UPON FINAL SITE STABILIZATION AND APPROVAL FROM CITY OFFICIAL. 1. SWEEP STREETS AS NECESSARY OR AS DIRECTED BY CITY INSPECTOR 8. CLEAN ON -SITE AND DOWNSTREAM PUBLIC STORM SYSTEM AS NECESSARY TO REMOVE ANY DEPOSITED SEDIMENTS. UTLITY CONFLICT NOT CAUTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATIONS PRIOR TO CONSTRUCTION. TH15 SHALL INCLUDE CALLING UTILITY LOCATE AT 1-800-424-5555 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSING TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST, LOCATION OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION, IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT ANSTEY ENGINEERING TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. SITE PLAN NOTES 1. SEE ARCHITECTURAL SITE PLAN BY THE KEIMIG ASSOCIATES FOR SITE LAYOUT/ DIMENSIONING. VERIFY ANY D15CREPENCIE6 WITH THIS ANSTEY ENGINEERING PRIOR TO CONSTRUCTION. SEE DETAIL AND PROJECT SOILS REPORT FOR CURB AND PAVING SECTION. 2. POST BUILDING ADDRESS WITH 18' HIGH LETTERS ON FACE OF BUILDING AS REQUIRED BY THE CITY OF AUBURN. FLEXIBLE GUIDE POST DELINEATOR WITH 3 ROWS. 1/2" REFLECTIVE TAPS`, TW, EXISIM MC>�IT CURB PER WSOOT F-10,64-00 88' EDGE OF PROPERTY EDGE OF PROPERTY AC PVMT 0041M MELLOW, y' T��y KE 1 I I • ti � r• �' �. 81, x _ _.. STONE .... a an :` > •- 4�>. tt . .. �.._..._, ,.._ ,._ TOP OF 81'CNE WALL ., _..ti::.. ,.awe ',.,fe:,.,lr. • w� NEW BI:IILD'I% i` 1C1' 8b.5 85 :,... s •d: • . d 85' • a • 84' EXISTNG __ • C-CURS DETAIL 82' SI' PRECAST CONCRETE CURB 80" SCALE NTS SITE CR%r-%F*O;ps GECTION SCALE- V 1-36 H 1-6 88' __ EDGE OF PROPERTY ___ _ EDGE OF_.PROPERTr TOP OF Y!3TONE _ i GRADE DB,S EXISTING BUILDING SLAB 81' __ _ TOP OF KEYSTONE - ! ST - -WALL 5' W FINISH GRADE 865' _ _ _ _ _�__ _ 81'. 86' _ ___ ...' '. ,• . _ , ; • . SIDEWALK'M;i CM _ _. _ • , ,. NEW ING "PAD 86 3' • , d , �7 TT _. •s s a �• WAL FINISH N • • d .: �. �OMPAc�.r�k•' : � • � ' :: .: . • �. %.. ' - •' •: :: ' � :.. •,.:.. -86 .: r FWD _— : • , _ mEMTHG GRADE 4. 84 dF WALL 03, 1 I I I I I JOPERI`Y CORNER 1 __j KEYS NE WALL 3'-(o' TOP ELEV. 1.0' TYF k BW 84'. PARCEL " 13210 VI3 PERIMETER OF SITE PER DETAIL EROSION-02 ING WORK KVUC3H UKAL) INCH HNLJ rct T 5 I VNt WALL CONSTRUCTION WAS COMPLETED UNDER SEPARATE PERMIT 'GRA08-0004 NOTE: CALL 1-800-424-5555 BEFORE YOU DIG FINISH GRADING PLAN SCALE- 90,11 ,ROUGH GRADING AND WA .L CATCH BASE PROTECTION CONSTRUCTION WERE STANDARD CITY DETAIL EROSION-04 COMPLETED UNDER SEPEf-'ATE SIL CONTROL FENCE GRADING PERMIT STANDARD CITY DETAIL EROSION-02 RECORD DRAWING CERTIFICATION I PROJECT REF: FAC08-0017 THESE DRAWINGS CONFORM TO THE CONTRACTOR'S CONSTRUCTIOW RECORDS. BY: UDATE:6 TITLE/POSITION: �. SfCtic.. wCONFIRMED BY CITY: DATE:4rO7e� i THESE PLANS ARE APPROVED FOR CONFORMANCE WITH THE CITY OF AUBURN'S ENGINEERING DIVISION REQUIREMENTS. APPROVED BY: ) ) �,'A� DATE APPROVED: w F f- w w V) 0 ' a 3 p O a V) z O V) w w Q 0 O z U w 0 IY C`•, I— OI -'-•I o r' W 00 o0 V) Cr) T_ Z ~ oo c" a a I > Z 00 <( 00 w z 1 !z cy- M m N Z Q N Q .I LLJ ry a E � 0 U CD O CD CD co m V-) _ (_0ou N -� CD 00 Q c O C � � UJ J w $. W ~O Z -F J to Q � co m C L- uj W Qz LIJ LLl W z r m a cz Ld z C7 Q w < z w w 1 W f- w w z fn POD/ oc) In CD SOUTH PROPERTY LINE NORTH PROPERTY LINE SOUTH PROPERTY LINE NORTH PROPERTY LINE I CD O NEW BUILDING NC) C) w >_ a - co RIDGE 86.51 GUARD RAIL J ELEV. 81.0 vV ........ ELEV_ 51.0 0 cl) < 0- LLj ._.._ ._..-.._.._.._.-------- < 0 3-1 0 (Y a. X ELEV. 86-0 ......... --­---------- - ........... 0 V) 0 ELEV; 860- - ........... ELEV. 8r:,.o ------- .................................... ........ --­-­---------------- --------------------- ------------ ................ .-ELEV. 85.0--- ELEV, 840 ............ ...... ............... ........ ........ .............. ------------------- .................. > 0- -------- ELEV. < . .. . .. . .. . . . .. . .. . . _.._..�. _._._ _._._ _ ................ ..... ELEV. 820 .............................. w ELEV. 83.0 ------- ELEV� 83D___ ...... ___._ ............. ... ................................... < ELEV, 81.0 ---------- ....... ELEV;82.0___ -0- ...... .............. ............. ........ ........... . . ..... ............ ELEV.- 810 ...... DI WATER "Ot 8' DI "TER PIPE EAST CROSS SECTION /-46\ WEST CROSS SECTION cn z0 SCALEH a I' a 30' SCALE- H Is 30' V) v > LA V J KEYSTONE WALL ;TOP 81.0 4' MIN CLASS 5 AC RIDGE = 66.5 RIDGE 865 RIDGE 865 O'MIN 5/8'-CRU5HED ROCK ELEV. 81.0 ........................... .. .... ....................... FHM GRADE 865f .. ............... ................ .......... ...................... ................. ­­- ----- -------- ELEV. 86,0 t........ A L ....... ELEV. 840 ....... ....... .7, 13'-22' OF 1-1/4'CRUSHED ROCK, 43'X2 4- - - _­11.7- - ___­_,_-­­i�_ - - i ELEV. 83.0 _,,­__,,­,,,,,­_­, '_­­­­'_­ - "­_ i I' CMP ARCH PIPE lift. Mp _--mill 4. A ELEV. 82D ---- ------ ............. ELEV. BID ...... -C -----------------­ ............ .... ......... F3111 TYPE 2:46' CB% T I PE 2' - - - ­ - -- - 14' MIN CIDF RIM z 860 95-W RIM = 8( .0 95.9Y 14'MIN Rim 8&0 bf.-ff 14'MH 0i V 82.0 1.97 IE 820 Li IE 82.0 21.2: L CCNFCL MN #1 54" ............ L-82D N 0 9-T H "SO DRAIN PROFILE�' ~� i RIM = 851 616-6W! IE A SCALE. H 1' • 30' E A. 44 . A . '. '. J* .•4 , : - (O'NIN. OF 50- CRUSHED ROCK UPPER ORIFICE - 4' e 134.11 v■11 5, BOTTOM ORIFICE I'm GI5#I 48- Ty 2 RIM a ee4tq.(b* 5TIRRORNGEPTOR 6TC 4501 RIM 2 BID %4p.(Vs IE - ~ . IE = 01-e1 IN bVtV KEYSTONE W,4LL TOP 810 RIDGE ■ 86.51 RIDGE O�P,5 swil 61. IE = 01.1a OUTbobj GMF ARCH PIPE DETAIL i 7117 ELEV. 81.0 -­------­---- --------- - ------ ELEV. 66.0 . .. . ...... N.T.5, ELEV.85.0 ................ V) ............ ------- ........ ------- ELEV. 84.24 .......... ...... . --------- uj . ...... .. ..... BOW 2 83,5 A! -----------_- ------ _Aq c H 1% 0.1 ELEV. 820 ELEV, 81.0r. .. .... .. ......... . ....... . ....... - ------------------------- - .. . ............ - ........... NEW 40' MH 02 TYPE 2 C5 E544 RIM 2 wo IE m 81B WEST 121%.40' LEGEND IE = 81.5 N-S C5' 4 TYPE 2-4a' GE' 3 TYPE 2-4V C15' 2 TYPE 2-40' RIM m e*.6 85. 92; RIM m 86.0 is.90, RIM x 8(02 POST INDICATOR VALVE IE 820 ISI.-72: 15 820 IE 02Z IRRIGATION METER STOW NOTE SANITARY SEWER NOTES: WATER NOTES WITH DOUBLE CHECK Fm wx 91. qs, VALVE 2' -24' FlJqB TYP, FOR BACKFLOW PREVENTION SEE STANDARD DETAIL 1. RESTORE AREA AROUND DETAIL REFER TO CITY STANDARD CATCH BASIN Im 5TOW-02 FOR STORM EX 6SMH TO AS GOOD OR CONTROL STRUCTURE BETTER CONDITION. WATER LIGHT POLE C14 0 U T H /D NORTH DRAIN PROFILE 1 0 F- SCALE- SURVEY BENCHMARK - NAVD 88 RIM OF THE 54' CONTROL STRUCTURE WILL BE e�&,l 2. CORE DRILL AND RECHANNEL REFERENCE DESIGN STANDARDS > o Ld 0 v ■ 1' ■ 5' THE INVERT ELEVATION WILL BE al,S5 EXISTING MANHOLE AS REQUIRED FOR BACKFLOW PREVENTION PHONE RISER I.- LLJ 00 00 THE BOTTOM ORIFICE WILL BE 1' 3. CONNECT TO MH W CORE 4SEAL BOOT DOMESTIC 101.2.1 H V) 0:� (n T_ THE TOP ORIFICE WILL BE 4' AT ELEV 83.95 IRRIGATION 1.01.2.2 A FIRE HYDRANT z I-_ oo THE OVERFLOW OF THE 12' STANDPIPE WILL BE 85.0 4. INSTALL SIDE SEWER PER < V) < I I PER DESIGN STANDARD STD DETAIL SEWER-02 FIRE 1.01.5-2 E THE BOTTOM OF THE MANHOLE LIE) WILL BE a5.5 UTILITY POLE > SEWER AND 1.01-5.2 C ADD 00 WATER 1 EASEMENT VALVE TO FIRE LINE THE 100 YEAR PEAK FLOW WILL BE 0.48CF6 AT ELEV 13r;,.O EXISTING WATER METER < - 00 EASEMEN I AT POINT OF CONNECTION THE 25 YEAR PEAK FLOW WILL BE 03(oCFS AT ELEV 84.5 CATCH BASIN L'i -72 -�7 1 EXISTING MANHOLE 5 TO PUBLIC WATERMAIN �b PARCEL STREET LIGHTING BOX 0:� 1321049020 THE 10 YEAR PEAK FLOW WILL BE 0.25CFS AT ELEV 84.2 ELEV 835� b3.0 1 1> THE 2 YEAR PEAK FLOW WILL BE O.OFCFS AT ELEV 81SO 'T;F):W- - - - - - I \ I/ . ,l/ - ZONE- C MANHOLE z m N INVERT -7to < - --- ---- A IT- 13 W 354.121 NEW KEYSTONE < IE z 1159 -6" < 105 z . ..... WALL CONNECT TO EX H PROPERTY LINE - ------ Lu PAt I - C5% Z_ KA ftwmffijj�, V C EXISTING WATER-w- -LL�- ---w- _W_ NEIGHBORING SITE PARCEL 5 MAIN LINE 5 T A (o 4.w 4 V'P6 V.7 1321049113 1*3 1 V) -7-1 ZONE C CONNECT TO. F---- 86-- NEW WATER EXISTING WAT MAIN WITH 8' * I i - -­ i MAIN LINE cn 0 TAPPING SADDLE ' 1 11 - - I I LOW HAZA AND 8' GATE I I I o7f7f * t ur-- I --I , I ROOF DRAIN/ -TI,_ _TL_ -TL- 0 00 i I u W.- Flmm ] I' METER o F- (7) VALVE I I I I DOUBLE C ECK TIGHT LINE 6' _j C 4 PIMIN ......... ur"T, 8- 2 RIM IE - te r 6 0 2 EX H w w tA �l 7�li 110 2, W41F-F- tTl I I c(l VAJ_vl� Ij I ', I I VALVE PE LA.. I 86;D G _cy, oxi 1 1.012 1" SANITARY _66- so -I%- _l% (D Ift I I tu qt" 1 INSTALL 8' POST 0 �zll It x 1­4 STOW DRAIN -6-- 8 - SO- V) I INDICATOR VALVE 0 :z FIRE $pRi E of �iTOPO LINE Lij LINE PER RE I 1>70 I > J� U-,l I M LO M LINE FERMT I ! WATER PITTING TABLELi D I w P�ARCEL Fu > LE) STA 4+98 0 L",21045046Ov (L l=­ CB E544 I- &'SO BEND MJxMJ 15, WATERLINE DOUBLE CHECK �INISH FLOOR ELEV. 81.0' f I EASEMENT VALVE PER IE 01�5 WEST 12- ID15_2E CATCH CL E PROVIDE 6TORZ Zffi I I I BASIN IE 815 N-S 21' W. 0 1 5TA 5+12 CONNECTION PER Lo iQWLU I- I I I , IOCOA SID WATER-01 FDC 00 1 RI HT OF W, Y 1- 5 114' MVO FIRE HYDRANT ASSY 0 11, If= INCII=LE RTEf;4AL (_0 MAINTAIN 5'z0'CLEARANCE i L 4 �j i i j z C: TREET E I- 8'x(o'X8'TEE MJxFL ------ I- 9>' GATE VALVE FLxMJ AROUND FIR HYDRANT N.9% (D 2 "a, C) I LLI TL <t I- 8' GATE VALVE FLXMJ CD C-D i AN _�TL� I I 1 00 I'lo WATERLINE p I - I I I 1� - (D d) I- CONCRETE BLOCKING c -0 00cn ---- ----- ---- Lu (Jo c: It, w i < co STA 5+10 zZ lu m �3 z I Lc) -0 - -- ---- _k X, � :�i -4 1- a'x4'x8' TEE MJxMJ Ljj CF. colww- n CB#2' Ap ------ 7- (D 0 w t ---- w (L Lmtj I- CONCRETE BLOCKING 065 8 5 LLJ I . -F ro. 0 < 5TA 5+S5 1> INSTALL 350 LF OF (_0 0 = < 1 30 BEND 00 M fa- L-1- Lij 8' DI WATER �MAIN PARCEL Ef 60NI �EC TO .�;fs In 0 CONCRETE BLOCKING 5TA �41 w I . ! , . ExIONG ic, INCH LAS SET SHALL BE SUBMITTED WA� R MAIN T (D TO THE LOCAL JURISDICTION NEIGHBORING SITE WIT 8' TAPPI�G, NOTES: EXISTING BUILDING SAD LE LE AND 5' I. KEYSTONE WALLS TO BE INSTALLED PER BY THE LEVEL 'U'CONTRACTOR FJ 1 GAT VALVE (9 > AND APPROVED 13Y THE MANUFACTURER'S INSTRUCTIONS. FIRE MARSHAL. BLOCKING, N uj a -- PIPING, AND RODDING DETAILS RESTORE DISTURBED AREA RECORD DRAWING CERTIFICATION -0017 LL1 SHALL N PROVIDED. SURROUNDING 51DE6EWER PROJECT REF: FAC08 APPROVAL OF CIVIL PLANS (D DOES NOT APPROVE THE FOR SEWER DETAIL REFERENCE UTILITY PLAN Lu THESE DRAWINGS CONFO[,M TO THE THESE PLANS ARE APPROVED FOR INSTALLATION OF THE "WLER STANDARD CITY DETAIL SCALE- V-20' CONTRACTOR'S INSTRUCTIORECORDS. CONFORMANCE WITH THE CITY OF AUBURN's 0 L SYSTEM SUPPLY 5EW!R-02 z ENGINEERING DIVISION REQUIREMENTS. cz BY: DATE: NOTE: CALL 1-800-424-5555 BEFORE YOU DIG TITLE/POSITION: Lll'#A) $"of &yise APPROVED BY: 5,eAA a_ < CONFIRMED BY CITY&2_DATlE:6/r-/,lY DATE APPROVED: Lli 09P197A ='NISH G=ADEfTOP Cf MULCH ' fl-l1P SPRAY OR 7ZOTOR SPRINKLER: AARLEX STREET EL, UING PIPE RISER A83EMEILY: BARS ELLS ANS 12' �IUING PIPE VC LATERAL PIPE r-VC °ICH d0 TEE OR :LL pop -Up SPRAY OR ROTOR SPRINKLER I )ETAIL 30-INCH LENGTH OF WIRE, COILED COILED WATER PROOF CONNECTION (1 OF 2) VALVE BOX WITH COVER: 12-INCH SIZE FINISH GRADE/TOP OF MULCH REMOTE CONTROL VALVE: PVC SCH 80 NIPPLE (3") PVC SCH 40 ELL PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) PVC SCH 40 MALE ADAPTER PVC SCH 40 TEE OR ELL PVC MAINLINE PIPE REMOTE CONTROL VALVE D E T A I L UTILITY CONFLICT NOTE: CAUTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 I-WO-424-5555 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOU.Jt`I ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT POE ENGINEERING, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. mnTc• DRn\/InF nlllr.K "INISH GRADE/TOP OF MULCH UICK-COUPLING VALVE: 0" VALVE PIT ALV. 3" NIPL -INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL ;ALV. STREET ELL ONC. BRICK ALV. 12" NIPL. ALV. STREET ELL 'VC SCH 40 TEE OR ELL 'VC MAINLINE PIPE ,ALV. ELL f 4 REBAR W/ S.S. I I �/ I I I PIPE CLAMPS QUICK-COUFL 1II G; V 4LVE 1A- 6 N T TE5 I RR1 ATI OI Y LE(=�END O RAINBIRD 1800 SERIES POP-UP ON SWING PIPE RISER PER DETAIL RAINBIRD 100-FEB CONTROL VALVE IN 5TD. BOX PER DETAIL RAINBIRD E5P-6LX+ CONTROLLER WALL MOUNT POWER BY ELECTRICIAN Q RAINBIRD 53LVC QUICK COUPLER PER DETAIL N I" FEBCO a50 PVC IN JUMBO BOX PER COA WATER-06 SEE CIVIL PLANS DQ I" CRANE GATE VALVE IN 10" PIT AS IRR, P.O.G. II-1 I" METER FOR IRRIGATION PER CITY WATER-06 DETAIL BY UTILITIES CONTRACTOR 1 1/2" 5CH40 PVC MAIN AT 15" DEPTH MIN CL200 PVC LATERALS AT 12" DEPTH MIN. 51ZEP PER CHART DESIGN BASED ON II/al/a GPM 6 60 P51 MIN, IF LESS FOUND, CONTACT LANDSCAPE ARCHITECT BEFORE INSTALLATION. PROVIDE ALL PERMITS AND INSPECTIONS. PROVIDE ONE YEAR WRITTEN WARRANTY ON ALI. PARTS AND LABOR. NO SUBSTITUTIONS. PLAN 15,DIAGRAMATIC AND ACTUAL FIELD LAYOUT 15 THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR IS TO PROVIDE MAINTENANCE AND OPERATION MANUALS TO OUNER AT FINAL WALK THRU, CONTRACTOR IS TO PROVIDE TIME OF OPERATION CALCULATIONS FOR MAY THRU OCTOBER TO PROVIDE A MAXIMUM OF 1" PER WEEK TOTAL PRECIPITATION FROM COMBINED WEATHER AND IRRIGATION: INSTALL RAIN SENSOR IN SECURE BUILDING LOCATION TO SHUT OFF IRRIGATION DURING WET PERIODS. CONTRACTOR SHALL MONITOR THE IRRIGATION ;SYSTEM AND ADJUST CONTROLLER TIMING TO REFLECT CLIMATIC AND WEATHER CHANGES AT LEAST ONCE PER MONTH DURING FIRST SEASON OF OPERATION TO INSURE OVERWATERING OR UNDERWATERING 15 NOT OCCURRING AND THAT NO OVER5PRAY ON PAVING OCCURS. ALL PIPE OR WIRE UNDER PAVING SHALL BE IN 5CH40 PVC SLEEVE AT LEAST IS" DEEP AND TWICE pIAM. OF INSERT PIPE. MEET ALL CODES PERTAINING TO ALL ASPECTS OF THE IRRIGATION SYSTEM. ANY DAMAGE TO FACILITIES OF UTILITIES WILL BE REPAIRED OR REPLACED TO OWNERS SATISFACTION. CALL BEFORE YOU DIG! LOCATE ALL UNDERGROUND FEATURES BEFORE TRENCHING. FIFE 151ZING PIPES TO BE SIZED ACCORDIN('i TO THE FOLLOWING TABLE: 0-10 GPM = 3/4' PIPE 11-IS GPM = 1" PIPE 19-25 GPM = 1 1/4' PIPE 26-34 GPM = 1 1/2' PIPE 36-55 GPM = 2" PIPE ALL PIPE SIZING IS BASED ON (1200 PVC PIPE CONTRACTOR TO DETERMINE PIPE SIZES PER THE ABOVE CHART. .- A. STATE OF WASHINGTON REGISTERED LANDSCAPE ARCHITECT D VID B. LOWMAN CERTIFICATE NO. 387 RRIOATICN FLAN 9 —5 PROJECT REF: FAC05-001-1 These plans are approved for conformance with the Clty of Auburn's Engineering Division Requirements. APPROVED BY: DATE APPROVED: PROJECT REFERENCE: FAC,08-0011 This plan sheet reflects the city of Auburn's minimum landscape requirements. APPROVED BY: DATE APPROVED: Record Drawing Certification These drawings conform to Contractors Construction Records. _ SYr /DATE r Title/position: Confirmed by Glty DATE: IllOrE : THE 1AR14A7"1ON SYSTEM WA.S Ato -- 1,-r s 7-,4c.LEb . v Cd z a� I� CIO co O o GD PC:) I c� c0 +' I co � v T-+ CC) cD 0 C\2 v v� H 0 to cQ LO O�yQ�N -.._I aj D O 'd m A cn A � Pd IU K O Sheet L.._ _ 09DNZZ 1�OT�� COMPLY WITH ALL G I TY ORD I NANCE5 AND OBTAIN ALL RE001 RED PERMITS AND I NSPEGTI ON5 INSTALL 6" COMP05TED TOP501L IN ALL PLANTING AREAS. INSTALL 5" BARK MULCH IN ALL PLANT BEDS PROVIDE ONE YEAR WRITTEN WARRANTY FOR ALL MATERIALS AND LABOR INSTALL AUTOMATIC, I RR I GAT I ON AS PER PLAN NO 5UE35TITUTIONS WITHOUT WRITTEN CONSENT OF LANDSCAPE ARCHITECT AND CITY REPAIR OR REPLACE ANY DAMAGE TO UTILITIES Off: FACILI'l IE5 TO OWNERS SATISFACTION LOCATE AND PROTECT ALL UNDERGROUND UTILITIES TILL PARKING LOT ISLAND 501L TO 18" DEPTH. DEG I DUOU5 TREE GAL I PER MEASURED AT 4.5' M I N I MIJM ABOVE ROOT BALL. CONIFEROUS TREE HT MEASURED FROM TOP OF GROUND AT TIME OF PLANTING. INSTALL ROOT BARRIER WHERE TREES ',�RE WITHIN 6 OF FAMED AAr�EA5 DECIDUOUS TREE 01 CHAINLOCK, LOCK 4 STAPLE TO STAKE (2) 2x2 FIR STAKES DRIVEN TO REFUSAL SET PLUMB 4 INLINE 2' LAYER BARK MULCH 2' DISHED EDGE PULL BACK BURLAP AND REMOVE WIRE BASKET 50/50 TOPSOIL/ NATIVE SOIL MIX SIT PIT 3 TIMES ITBALL DIAM. AT TOP iwlc:E AT BOTTOM TREE STAKING DETAIL N.T.S. UTILITY CONFLICT NOTE: CAUTION: � • r (,% ^� PL aNT PIT 3 TIMES ��"' • w KOT13ALL DIAM. AT TOP TWICE AT BOTTOM 2' LAYER BARK —" 1' DISHED EDGE FOLD BACK TOP THIRD OF BURLt-:P 50/50 TOPSOIL: NATIVE SOIL MI:: SHME3 PLANTING DETAIL KTA. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEP 1- OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTIL , ITIF 5 AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THI5 SHALL INCLUDE CALLING UTILITY LOCATE 9 1-600-424-5555 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PH`'SICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT POE ENGINEERING, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. 'IT 3 TIMES 4LL DIAM. AT TOP ,T BOTTOM. ONIFEROUS TREE K2 FIR TREE STAKE CHAINLOCK, LOCK STAPLE TO STAKE BARK MULCH 'DISHED EDGE NFOLD TOP THIRD IF BURLAP 4 REMOVE In BASKET 0/50 TOPSOIL/ ATIVE SOIL MIX CONIFEROU5 TREE STAKING NT,S. 132104,1113 ZONE-C 1321014g020 MARVEL DELI 15210441046 LONGHORN RESTAURANT 132104104-7 6TH STREET 5W SIGHT DISTANCE PLAN, T 5 FLAhr L I ST LIOUIDAMER STYRACIFLUA - 5WEETGUM 2" GAL. 64B SPACED AS 5HOWN AGER PLATANOIDE5 - NORWAY MAPLE 2" GAL. B$ B SPACED AS SHOWN CHAMAECYPARI5 NOOTKATEN515 - WEEPING ALASKA CEDAR 6--I' HT. 64 B SPACED AS SHOWN 2 AGER RUBRUM RED SUNSET - RED SUNSET MAPLE 2" GAL. 665 SPACED AS SHOWN ® 12 MAHONIA AOUIPOLIUM.- OREGONORAPE 2 GAL. 4' O.G. '�►�` 11 THUJA PYRAMIDAL15 '5MA6ARD' - EMERALD GREEN ARBORVITAE 5-6' HT. B4 B 3' O.C. 0 22 COTONEASTER PARNEYI - PARNEY GOTONEASTER 3 GAL. 4' O.G. O a JUNIPEROU5 CHINEN515 'OLD GOLD'- OLD GOLD JUNIPER 5 GAL. 4' O.G. ® 16 PRUNUS LAUR. 'OTTO LUYKEN' - OTTO LUYKEN LAUREL 2 GAL. 4' O.C. GD GOTONEASTER DAMERI - BEARBERRY GOTONEA5TER 4" POTS IS" O.G. IN ALL PLANT BEDS Linear Application of DeepRoot Tree Root Barriers at Time of Installing Concrete Sidewalks and Curbs TYPICAL SECTION OF CURB AND GUTTER WI TH DEEPROOT TREE ROOT BARRIER INSET INTO CONCRETE. 1 BARRIER INSTALLED IN A TRENCH IN 5UBGRZADE WHICH 15 ��7" THEN COMPACTED. BARRIER IS SET 50 THAT TOP EDGE WILL BE 2' (5CM) BELOW FINISH GRADE OF CURB, AND SET FLUSH WITH EDGE OF CURB. BARRIER RIBS FACE TOWARD TREE ROOTS. Top of root barrier 2' (5cm) below finish grade of curb INSTALLATION SEQUENCE: I. Prepare base and subgrade Concrete 2. Trench to appropriate depth for Installation of \ root barrier so that top of barrier Is 2' (5cm) below finish grade of top of curb. Compacted crushed base 3. Place root barrier In trench, vertical ribs must Fare toward tree roots. } 4. Backfill and compact to requirements. subgrade compaction 5. Place form material against barrier (It may be Typical DeepRoot UB 24-2, nailed from the outside of the form) optional use of UB 18-2 TYPICAL SECTION OF CURB, GUTTER AND SIDEWALK INSTALLATION SEQUENCE: WITH DEEPROOT TREE ROOT BARRIER INSET INTO CONCRETE BARRIER INSTALLED IN A TRENCH IN 6U55RADE WHICH 16 THEN COMPACTED. BARRIER 16 SET 60 THAT TOP EDGE WILL BE 2' (5CM) ABOVE COMPACTED BASE for halfway between base and finish grade of 6W). BARRIER RIBS FACE TOWARD TREE ROOTS. Concrete IAANx a a d Subgrade compaction Compacted crushed base. T Ica[ pee Root UB 0 lonaPus�of UB 0- To pp of root barrier (5cm) below finish a J:' . grade of curb 4 Base; •.,�� }.: :..�.$.�,r f ::?`,;: 6ubgra 5/8' (lbmm) I Deep�ct UB 2q-2, `II UB 18-2 or LB 12-1- G — s-01 LAN L)SGAPE FLAN I. Prepare base and subgrade 2. Trench to appropriate depth for Installation of root barrier so that top of barrier Is 2' (5cm) below finish grade of top of sidewalk (or halfway between top of compacted base and finish grade of SW) 3. Place root barrier In trench, vertical ribs must face toward tree roots. 4. Backflll and compact to requirements. 5. Place form material against barrier lit may be nailed from the outside of the form) IMPORTANT NOTE: Tree location must align with 'as -built' center of barrier. Typical DeepRoot UB 24-2.Optlonal use of UB 18-1. Minimum 6 panels or 12 linear feet (3b6m). FAC05-001-1 PROJECT REF, These plans are approved for conformance with the '�d CFt9 of Auburn's Encjin! ruj D 161 ants. APPROVED BY. DATE APPROVED. > '� FAC06-001-1 PROJECT REFERENCE, This plan eheet reflects the city of Auburn'e minimum landscape requirements. rrr��� nn APPROVED BY. (% Q DATE APPROVED, Record Drawing Certification . STATE poF WASHINGTDN These drawings conform to the Contractors REGISTERED - LVOSCAPE ARCHITECT Corot tion Records. -. _ R DATIi, (yt�p a (yam w CERTIFICAtEtNO. 397 Tltleipoeltion. confirmed bg City ASS e ~;;R, cc) O bL co {' I co I— Q) a> --I Cf) CO CD CD C\2 ru—�J w C% W E­ 0 cD Lo wMw rl" 1 Cy (V U ) A � Ix O Z Z Y Q Sheet L-I of