Loading...
HomeMy WebLinkAbout2025, Hold Harmless Agreement, Port of Skagit County8/14/2025 Heather Rogerson, Dir. Planning & Dev. 214 EAST GALER STREET, SUITE 300 SEATTLE, WA 98102 206.233.9639 MAIN 866.727.0140 FAX PBSUSA.COM Hazardous Materials Survey Report Port of Skagit SWIFT Center Douglas Building 1960 Northern State Road Sedro-Woolley, Washington 98284 Prepared for: RMC Architects 1223 Railroad Avenue Bellingham, Washington 98225 October 30, 2023 PBS Project 41140.017 Hazardous Materials Survey Report RMC Architects Port of Skagit SWIFT Center – Douglas Building Sedro-Woolley, Washington i October 30, 2023 PBS Project 41140.017 Table of Contents TABLE OF CONTENTS ......................................................................................................................................... 1 1 INTRODUCTION ........................................................................................................................................... 1 1.1 Project Background................................................................................................................................................................... 1 1.2 Building Descriptions ............................................................................................................................................................... 1 1.3 Survey Process ............................................................................................................................................................................ 1 2 FINDINGS ...................................................................................................................................................... 1 2.1 Asbestos-Containing Materials (ACMs) ............................................................................................................................ 1 2.2 Lead-Containing Components ............................................................................................................................................. 5 3 RECOMMENDATIONS .................................................................................................................................. 6 3.1 Asbestos-Containing Materials (ACMs) ............................................................................................................................ 6 3.2 Lead-Containing Components ............................................................................................................................................. 6 3.3 Mercury-Containing Components ...................................................................................................................................... 6 3.4 PCB-Containing Components ............................................................................................................................................... 6 Supporting Data APPENDICES Appendix A: PLM Bulk Sampling Information PLM Bulk Sample Inventory PLM Bulk Sample Laboratory Data Sheets PLM Bulk Sample Chain of Custody Documentation Reference Drawings Appendix B: AA Lead Paint Chip Sampling Information AA Lead Paint Chip Sample Inventory AA Lead Paint Chip Laboratory Data Sheets AA Lead Paint Chip Chain of Custody Documentation Appendix C: PBS Inspector Certifications ©2021 PBS Engineering and Environmental Inc. Hazardous Materials Survey Report RMC Architects Port of Skagit SWIFT Center – Douglas Building Sedro-Woolley, Washington 1 October 30, 2023 PBS Project 41140.017 1 INTRODUCTION 1.1 Project Background PBS Engineering and Environmental Inc. (PBS) performed a hazardous materials survey of the Douglas Building at the Port of Skagit SWIFT Center in Sedro-Woolley, Washington in conjunction with the planned demolition of the structure. The intent of this investigation is to ensure compliance with applicable regulatory requirements that a "good faith inspection” for asbestos-containing materials (ACMs) be performed prior to renovation and restoration activities. All accessible areas associated with the project were inspected for the presence of ACMs, lead-containing paint (LCP), mercury containing components, and polychlorinated biphenyls (PCBs). PBS based its survey on drawings completed by Decker and Christensen Architects, dated April 25, 1960. 1.2 Building Descriptions The Douglas Building is a three-story concrete structure with a flat, ballasted roof, built in 1961. Interior floor finishes include: 9” vinyl floor tile, 12” vinyl floor tile, sheet vinyl flooring, ceramic tile, carpet, and concrete. Walls are typically concrete with plaster and a skim coat finish and ceiling feature 12” acoustical ceiling tiles which are glued to concrete. The exterior of the building is concrete, and windows are typically metal framed. 1.3 Survey Process Accessible areas included in the project scope were inspected by Asbestos Hazard Emergency Response Act (AHERA) Certified Building Inspectors Kaitlin Soukup (Cert. No. 179143, Exp. 10/14/2021), Claire Tsai (Cert. No. IRO-21-7316B, Exp. 1/18/2022), Toan Nguyen (Cert. No. IN-219206B, Exp. 4/14/2022) from August 18-30, 2021. This inspection included the basement, ground floor and 1st Floor of the central core and the entire east wing. From October 7-9, 2023. Janet Murphy (Cert. IMR-23-8300A 03/02/2024PBS inspect the 2nd Floor of the central core and west wing. Inaccessible areas were not inspected. These include those areas requiring selective demolition, fall protection, or confined space entry protocols to gain access. When observed, suspect materials were sampled. All samples were assigned a unique identification number and transmitted for analysis to Seattle Asbestos Test (NVLAP #201057-0) under chain-of-custody protocols. Samples were analyzed according to EPA Method 600R-93/116 using Polarized Light Microscopy (PLM), which has a reliable limit of quantification of 1% asbestos by volume. PBS endeavored to determine the presence and estimate the condition of suspect materials in all inaccessible areas included in the scope of work. While PBS has endeavored to identify the ACMs that may be found in concealed locations, additional unidentified ACMs may exist. 2 FINDINGS 2.1 Asbestos-Containing Materials (ACMs) The following materials were determined to contain greater than 1% asbestos as part of this investigation. • 9” vinyl floor tile (red, beige, gray, white, brown) and associated black mastic – throughout West and East Wings, Administration Corridor 801, 827, Staff Office 822, Medical Library 812, Waiting Area 808, Janitors Closet 816 A and B, Vault 809, – approximately 30,710 SF; • 9” vinyl floor tile (red, beige, gray, white, brown) and associated black mastic (concealed) under shower and tub inserts in Bathrooms throughout – approximately 300 SF; • 9” vinyl floor tile (red, beige, gray, white, brown) and associated black mastic (concealed) under carpet in Rooms 806, 810, 811, 813, 820, 819, 818, 817, 824, 825, 826, – approximately 7,200 SF; Hazardous Materials Survey Report RMC Architects Port of Skagit SWIFT Center – Douglas Building Sedro-Woolley, Washington 2 October 30, 2023 PBS Project 41140.017 • 9” vinyl floor tile (red, beige, gray, white, brown) and associated black mastic (concealed) under sheet vinyl in Corridors 901, 910,938, Nurses Station 907, Quiet Rooms 902, 903, 904, 905, 906, Physical Therapy Room 927– approximately 8,000 SF; • 9” vinyl floor tile (green) patch – Northeast Recreational Therapy Area (Room 435) – approximately 4 SF; • Fire Doors (presumed) – central core 2nd Floor, Corridor 901 and 938 – approximately 6 EA • Black sink undercoat – Southeast Laundry Room, Northeast Laundry Room and Medication Room 501, Medication Room 601, Medication Room 915, Utility Room 902, Utility Room 911, Kitchen 926, Exam Room 933, Exame Room 934, Medication Room 915, Nurses Work Room 929 – approximately 12 EA; • Texture on concrete ceilings – Southeast Bathroom 1 and 2 (Rm 330), Northeast Bath Room 1 ( Rm 427), Northeast Bath Room 1 and 2 (Rm 430) Southwest Dressing (Rm 132), Northwest Bathroom and Shower (Rm 130-131)– approximately 1,400 SF; • Black hanger mastic on metal duct – Basement, far ends of east and West Corridors – approximately 510 SF; • Hard mudded fitting insulation – ceiling hatches in hallway (341) at Southeast Home Room (334) and Northeast Exercise Room (434) – approximately 30 EA; • Hard mudded fitting insulation on 2” fiberglass straight run – wall hatch in Restrooms (130, 230, 330, 430, 502, 503, 602, 603, 706, 723, 724, 707, 814, 815, 920 and 924) – approximately 35 EA; • Hard mudded fitting insulation on 6” fiberglass straight run (exposed) – Rooms 8, 15, 11 – approximately 5 EA; • Hard mudded fitting insulation on 4” fiberglass straight run (exposed) – Basement Corridors; Room 1, 11, 12, 16, 17 – approximately 46 EA; • Hard mudded fitting insulation on 4” fiberglass straight run (concealed) – throughout – approximately 1,000 EA; • Thermal system insulation on 6” pipe (exposed) – Basement Corridors; Rooms 7, 8, 9, 16, 17, 19 – approximately 1,420 LF; • Thermal system insulation on 6” pipe – Crawlspace accessed via floor hatch in East Wing and West center Utility Room (between elevator and Nurses’ Station) – approximately 26 LF. • Thermal system insulation on 4” pipe (exposed) – Basement Corridors; Rooms 1, 2, 7, 8, 9, 11, 16, 17, 18, 19, 23 – approximately 2,085 LF; • Thermal system insulation on 4” pipe – Crawlspace accessed via floor hatch in East and West Wings center Utility Room (between elevator and Nurses’ Station) – approximately 26 LF; • Hard white insulation on roof drains – in central core, East and West Wings concealed above ceilings – approximately 65 LF; • Thermal System Insulation – in Central Core, East and West Wings concealed above ceilings on the backs of ceiling tiles – approximately 6 SF; • Thermal system insulation on 4” pipe (concealed) – throughout above ceilings and in walls – approximately 2,000 LF; • Interior and exterior window frame caulk – throughout all elevations – approximately 16,676 LF; Hazardous Materials Survey Report RMC Architects Port of Skagit SWIFT Center – Douglas Building Sedro-Woolley, Washington 3 October 30, 2023 PBS Project 41140.017 • Soft, gray interior window putty – throughout all elevation – approximately 14,845 LF; • Cement asbestos board (CAB) - exterior wall panels at all elevations of building – approximately 5,576 SF; • Caulking/sealant – exterior CAB panels – approximately 8,925 LF. The following materials sampled and found not to contain detectable concentrations of asbestos as part of this investigation. • Green carpet mastic – Room 224 • Yellow carpet mastic – throughout • Gray leveling compound – throughout • Gray window putty – ground floor Clerks Office at interior of window • White counter laminate and yellow/clear mastic – Medicine Rooms, Dining Rooms, Nurses Station and Medication Rooms throughout • 9” blue vinyl floor tile and associated yellow mastic – Room 306 • 9” green and white streaked vinyl floor tile and mastic – Rooms 933 and 934 • 12” gray with white specks vinyl floor tile and associated yellow mastic – throughout • 12” white vinyl floor tile and associated yellow mastic – East and West Wing Custodial Cosets and Seclusion Room (NW-10) • Blue pebble pattern sheet vinyl flooring with associated cream and yellow mastics – East and West wing kitchens • Gray sheet vinyl flooring and associated cream mastic – 1st floor East Wing Nurses’ Station • Gray /light blue/tan pebble pattern sheet vinyl with fuzzy backing and yellow mastic – in Laundry Rooms, Exam Rooms, and Bathrooms throughout • Speckled sheet vinyl flooring and associated beige mastic – Hallway at Room 328 • Beige sheet vinyl flooring and associated yellow mastic – throughout • Tan sheet vinyl flooring and associated yellow or tan mastic – throughout • Brown sheet vinyl flooring and associated yellow mastic – throughout • Brown cementitious material – 3rd floor, under current flooring • Grout associated with quarry tile – Solarium (Room 909) • Tan quarry tile and mortar – Solarium (Room 909) • Grout associated with 1” ceramic floor tiles – Restrooms, Shower Rooms and Change Rooms, throughout • Mortar associated with 1” ceramic floor tiles – Restrooms, Shower Rooms, Change Rooms, throughout • Grout associated with 4” ceramic wall tiles – Restrooms, Shower Rooms, Change Rooms, throughout. • Mortar associated with 4” ceramic wall tiles – Restrooms, Shower Rooms, Change Rooms, throughout. • Yellow mastic associated with 4” ceramic wall tiles – Restrooms, Shower Rooms, Change Rooms, throughout Hazardous Materials Survey Report RMC Architects Port of Skagit SWIFT Center – Douglas Building Sedro-Woolley, Washington 4 October 30, 2023 PBS Project 41140.017 • 4” brown cove base and associated dark brown mastic – Patient Wings, Offices, Dining Rooms, Treatment Rooms throughout • 6” gray cove base and brown mastic - Patient Wings, Offices, Dining Rooms, Treatment Rooms throughout • 6” gray cove base and tan mastic - Patient Wings, Offices, Dining Rooms, Treatment Rooms throughout • Black threshold material – Restrooms throughout • Brown/Yellow/Cream mastic associated with fiberglass reinforced plastic panels – in Corridors, Shower Rooms and Change Rooms throughout • Yellow mastic behind corkboard strips – Rooms in East and West wing • Yellow mastic on back of wardrobe – Rooms in East wing • Gray sink undercoat – Room 310 • Joint compound and gypsum wallboard – 2nd floor Corridor • White skim coat on plaster ceiling and walls – throughout • 12” acoustical ceiling tile and tan mastic – throughout • 12” acoustical ceiling tile and white mastic – Sleeping Room 409 (NE-18) • 12” acoustical ceiling tile and brown mastic – throughout • Concrete masonry unit mortar – on walls in Mechanical Rooms , basement and stairwells • Red firestop – throughout • Gray duct sealant – throughout • Yellow mastic on metal duct – throughout crawlspace • Fiberglass wrap on column seam – Storage Room 18 • Fiberglass wrap with black mastic – throughout crawlspace and pipe chases • Black expansion joint in concrete masonry unit wall – Basement • White sealant at pipe penetration in floor – Southeast Utility Room • White sealant between sink and counter – East Wing Laundry Rooms • White caulk on gypsum wallboard panel – Southeast Home Room (334) ceiling hatch • White caulk between acoustic ceiling tile and wall – Patient Room 316 (SE-11) • White window frame caulk – throughout • Interior gray and white door frame caulk – throughout • Sealant between wall and column – Southeast Wing, north elevation • Mortar between terracotta blocks – South driveway at main entrance • Plaster on concrete (exterior) – Southeast Wing, south elevation • Texture on exterior concrete walls – West Wing Hazardous Materials Survey Report RMC Architects Port of Skagit SWIFT Center – Douglas Building Sedro-Woolley, Washington 5 October 30, 2023 PBS Project 41140.017 • Wall texture – administrative office Room 225 • White sealant on fasteners and rooftop vents – Roof throughout • Black sealant on roof vent – Roof, Center Core • Gray sealant behind fiberglass wall insulation – Penthouse Mechanical Room on Roof • Brown flashing sealant – Roof, Center Core • Asphaltic roofing under ballasted roofing system • Black waterproofing – East Wing, floor hatch in center Utility Room, east wall of elevator shaft Refer to Appendix A for specific samples locations and associated laboratory analysis. Refer to reference drawings provided in Appendix A to coordinate room numbers presented above. 2.2 Lead-Containing Components Seventeen (17) representative painted coatings were sampled for lead content. The samples were assigned unique identification numbers and transmitted to NVL Laboratories, Inc. (AIHA IH #101861) in Seattle, Washington under chain-of-custody protocols for analysis using Flame Atomic Absorption. Lead was detected in the following painted coatings. • Brown paint on metal flashing – exterior south elevation, 0.018% lead • Red paint on metal flashing – exterior north elevation, 0.013% lead • Yellow paint on concrete masonry unit wall – basement (0.016% lead) • White paint on concrete wall – Sleeping Room 307 (SE-19), 0.029% lead • White paint on concrete wall – 2nd Floor, room at end of corridor, 0.11% lead • Pink paint on plaster wall – West Wing Storage room, 0.072% lead • White paint on gypsum wallboard wall – West Wing Patient Room 116 (SW16), 0.19% lead • Gray paint on plaster wall – West Wing 1st Floor office, 0.021% lead The following painted coatings were sampled and determined not to contain detectable lead. • White paint on concrete wall – Rooftop Penthouse • White paint on metal trim – Rooftop Penthouse • Off-white paint on concrete wall – south elevation • Red paint on wooden door – north elevation • White paint on plaster wall – Sleeping Room 213 (NE-14) • White paint on concrete wall – Northeast Day Space • Blue paint on wood door – Northwest Wing Bathroom 1 Door • Brown wood counter – Northwest Wing Dining room counter • Blue paint on concrete stairs – Stairwell 2 Refer to Appendix B for specific sample locations and associated laboratory analysis. Hazardous Materials Survey Report RMC Architects Port of Skagit SWIFT Center – Douglas Building Sedro-Woolley, Washington 6 October 30, 2023 PBS Project 41140.017 2.3 Mercury-Containing Components All fluorescent light tubes are presumed to contain mercury. Approximately 3,704 four-foot, 500 two-foot light tubes, and 660 compact fluorescent bulbs were observed in the accessible areas of the building. 2.4 PCB-Containing Components PBS used a Phillips Ballast Checker to inspect representative fluorescent light fixture ballasts throughout the work areas. PBS did not observe magnetic ballasts. All ballasts should be inspected prior to being disposed of. 3 RECOMMENDATIONS 3.1 Asbestos-Containing Materials (ACMs) PBS recommends that all ACMs that may be impacted by project activities be removed prior to impact. A qualified Washington State licensed asbestos abatement contractor should be employed to remove all such ACM according to applicable local, state, and federal regulations. The possibility exists that additional suspect ACMs may be present in concealed locations, including but not limited to, equipment, wall and ceiling cavities, and utility chases. These materials may include, but are not limited to, waterproofing membrane, internal gaskets, caulking and sealants of heating, ventilation, and air conditioning (HVAC) equipment and construction adhesives and wall mastics. In the event that suspect ACMs is uncovered during construction, contractors should stop work immediately and inform the owner promptly for confirmation testing. All untested materials should be presumed asbestos-containing or tested for asbestos content prior to impact. 3.2 Lead-Containing Components Representative interior and exterior painted coatings were found to contain lead. Impact of painted surfaces with detectable concentrations of lead requires construction activities to be performed according to Washington State Department of Labor and Industries (L&I) regulations for Lead in Construction. Impact of painted surfaces with detectable concentrations of metals in building materials and products requires construction activities to be performed according to Washington Administrative Code (WAC) 296-155-176 Lead in Construction and WAC 173-303 Dangerous Waste Regulations. Painted coatings may exist in inaccessible areas of the work area or in secondary coatings. Any previously unidentified painted coatings not sampled should be considered lead containing until sampled and proven otherwise. Dust control and housekeeping is crucial in preventing worker and occupant exposures. 3.3 Mercury-Containing Components Fluorescent lamps are known to contain mercury vapor. PBS recommends that all fluorescent lamps be carefully handled and recycled/disposed of in accordance with the contract documents and applicable regulations during construction activities. Breakage of lamps should be avoided to prevent potential exposures to mercury. L&I requires specific training, handling, engineering controls, and disposal practices when performing this work. All waste shall be handled in accordance with WAC 173-303. 3.4 PCB-Containing Components PBS recommends all light ballasts be inspected prior to disposal. Magnetic ballasts should be presumed to contain PCBs and properly removed, stored, transported and disposed of in accordance with WAC 173-303 Dangerous Waste Regulations and 40 CFR Part 761 Subpart D. Electronic ballasts do not contain PCBs and can be disposed of as general debris in compliance with applicable codes and endpoint facility requirements. Please do not hesitate to contact us if you have any questions regarding this report or require additional information. Hazardous Materials Survey Report RMC Architects Port of Skagit SWIFT Center – Douglas Building Sedro-Woolley, Washington 7 October 30, 2023 PBS Project 41140.017 Report prepared by: Report reviewed by: Janet Murphy Mark Hiley AHERA Building Inspector Senior Project Manager Cert. # 179143, Exp. 10/14/2021 APPENDIX A PLM Bulk Sampling Information PLM Bulk Sample Inventory PLM Bulk Sample Laboratory Data Sheets PLM Bulk Sample Chain of Custody Documentation Reference Drawings Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-01 Green carpet mastic 2nd floor, Room 224, southwest Layer 1: Green/trace black mastic NAD SATBlack mastic Layer 2: Trace gray brittle material NAD 41140.017-02 Yellow carpet mastic 2nd floor, Solarium Layer 1: Yellow mastic NAD SATGray leveling compound Layer 2: Gray brittle material NAD 41140.017-03 Yellow carpet mastic 1st floor, east wing, storage room Layer 1: Yellow mastic NAD SATBrown vinyl floor tile west of elevator Layer 2: Brown vinyl NADYellow mastic Layer 3: Yellow mastic NAD 41140.017-04 9" red vinyl floor tile 1st floor, northeast corridor near Layer 1: Red tile 3% Chrysotile SATBlack mastic Northeast Bath 1 Layer 2: Black mastic NAD 41140.017-05 9" red vinyl floor tile 1st floor, northeast corridor at door Layer 1: Red tile 3% Chrysotile SATBlack mastic to NE-4 Layer 2: Black mastic NAD 41140.017-06 9" vinyl floor tile 1st floor, southeast corridor at Layer 1: Red tile 3% Chrysotile SATBlack mastic Southeast Utility 2 Layer 2: Black mastic 4% Chrysotile 41140.017-07 9" red vinyl floor tile 1st floor, southeast corridor at SE-11 Layer 1: Red tile 3% Chrysotile SATBlack mastic Layer 2: Trace black mastic 4% Chrysotile 41140.017-08 9" beige vinyl floor tile 1st floor, northeast corridor at Layer 1: Beige tile 3% Chrysotile SATBlack mastic Northeast Bathroom 1 Layer 2: Black mastic NAD 41140.017-09 9" beige vinyl floor tile 1st floor , NE-4 Layer 1: Beige tile 3% Chrysotile SATBlack mastic Layer 2: Black mastic 4% Chrysotile 41140.017-10 9" beige vinyl floor tile 1st floor, southeast corridor at Layer 1: Beige tile 3% Chrysotile SATBlack mastic Southeast Bathroom 2 Layer 2: Trace black mastic 4% Chrysotile 41140.017-11 9" beige vinyl floor tile 1st floor at door to SE-19 Layer 1: Beige tile 3% Chrysotile SATBlack mastic Layer 2: Black mastic 3% Chrysotile 41140.017-12 9" green vinyl floor tile Northeast Recreational Therapy, Layer 1: Green tile 3% Chrysotile SATYellow mastic north Layer 2: Yellow mastic NAD 41140.017-13 9" blue vinyl floor tile Room 306 Layer 1: Blue vinyl NAD SATYellow mastic Layer 2: Yellow mastic NAD October 30, 2023 NAD - No Asbestos Detected 1 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-14 12" gray with white specks vinyl Northeast Day Space, threshold Layer 1: Gray/white tile NAD SATfloor tileYellow mastic Layer 2: Yellow mastic NADWhite leveling compound Layer 3: White brittle material NAD 41140.017-15 12" gray with white specks vinyl Northeast Exercise Room, floor Layer 1: Gray/white tile NAD SATfloor tile hatchYellow mastic Layer 2: Yellow mastic NAD 41140.017-16 12" tan vinyl floor tile Northeast corridor at NE-16 Layer 1: Tan tile NAD SATBlack mastic Layer 2: Black/yellow mastic NAD 41140.017-17 12" tan vinyl floor tile Northeast corridor at NE-4 Layer 1: Tan tile NAD SATBlack mastic Layer 2: Black mastic 4% Chrysotile 41140.017-18 12" tan vinyl floor tile Room SE-16 Layer 1: Tan tile NAD SATBlack mastic Layer 2: Black mastic 4% Chrysotile 41140.017-19 12" tan vinyl floor tile Room SE-4 Layer 1: Tan tile NAD SATBlack mastic Layer 2: Black mastic 4% Chrysotile 41140.017-20 12" white vinyl floor tile Northeast corridor, Chore Cabinet Layer 1: White tile NAD SATYellow/black mastic Layer 2: Trace black/yellow mastic NAD 41140.017-21 12" white vinyl floor tile Northeast corridor, Laundry Room Layer 1: White tile NAD SATYellow mastic Layer 2: Yellow mastic NAD 41140.017-22 12" white vinyl floor tile Southeast Utility 2 Layer 1: White tile NAD SATYellow mastic Layer 2: Yellow mastic NAD 41140.017-23 12" white vinyl floor tile Southeast Utility 1 Layer 1: White tile NAD SATYellow mastic Layer 2: Yellow mastic NAD 41140.017-24 Blue pebble sheet vinyl flooring Southeast wing, Kitchen 4 Layer 1: Blue vinyl NAD SATGray mastic Layer 2: Gray mastic NADLayer 3 Trace gray brittle material NAD 41140.017-25 Blue pebble sheet vinyl flooring Northeast wing, Kitchen 3 Layer 1: Blue vinyl NAD SATCream mastic Layer 2: Cream mastic NAD October 30, 2023 NAD - No Asbestos Detected 2 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab Gray leveling compound Layer 3: Gray brittle material NADYellow mastic Layer 4: Yellow mastic NAD 41140.017-26 Gray pebble sheet vinyl flooring Northeast Exercise Room, southwest Layer 1: Gray sheet vinyl NAD SATYellow mastic Layer 2: Gray fibrous material with yellow mastic NADLayer 3: Gray brittle material NAD 41140.017-27 Gray sheet vinyl flooring 1st floor east wing Nurses' Station Layer 1: Gray sheet vinyl NAD SATCream mastic Layer 2: Cream mastic NADGray leveling compound Layer 3: Gray brittle material NAD 41140.017-28 Speckled sheet vinyl flooring Room 310 Layer 1: Beige sheet vinyl NAD SATBeige mastic Layer 2: Gray fibrous material with beige mastic NADGray leveling compound Layer 3: Gray brittle material NAD 41140.017-29 Beige sheet vinyl flooring Hallway at Room 328 Layer 1: Beige vinyl NAD SATYellow mastic Layer 2: Yellow mastic NAD 41140.017-30 Beige sheet vinyl flooring Southeast Recreational Therapy Layer 1: Beige vinyl NAD SATYellow mastic Room, northeast Layer 2: Yellow mastic NAD 41140.017-31 Beige sheet vinyl flooring Northeast Recreational Therapy Layer 1: Beige vinyl NAD SATYellow mastic Room, north Layer 2: Yellow mastic NAD 41140.017-32 Yellow mastic Room 319, under new sheet vinyl Layer 1: Yellow mastic NAD SATTan sheet vinyl flooring Layer 2: Tan vinyl NADYellow mastic Layer 3: Yellow mastic NAD 41140.017-33 Tan sheet vinyl flooring Room 328 Layer 1: Tan vinyl NAD SATYellow mastic Layer 2: Yellow mastic NAD 41140.017-34 Tan sheet vinyl flooring 1st floor, corridor at Northeast Bath 1 Layer 1: Tan vinyl NAD SATTan mastic Layer 2: Tan mastic NAD 41140.017-35 Brown sheet vinyl flooring Hallway at Room 328 Layer 1: Brown sheet vinyl NAD SATYellow mastic Layer 2: Yellow mastic NAD 41140.017-36 Brown sheet vinyl flooring 1st floor, east wing, Medication Layer 1: Brown vinyl NAD SATYellow mastic Room Layer 2: Yellow mastic NAD October 30, 2023 NAD - No Asbestos Detected 3 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-37 Brown cementitious material 3rd floor, east corridor Layer 1: Gray/brown sandy/brittle material NAD SATLayer 2: Yellow mastic NAD 41140.017-38 Brown cementitious material 2nd floor, east corridor Layer 1: Gray/brown sandy/brittle material NAD SATLayer 2: Yellow mastic NAD 41140.017-39 Yellow carpet mastic Outside of Room 331 Layer 1: Yellow mastic NAD SATVinyl floor tile Layer 2: Gray vinyl NADMasticLayer 3: Yellow mastic NADBrown cementitious material Layer 4: Gray/brown sandy/brittle material NAD 41140.017-40 Grout associated with quarry tile 2nd floor, Solarium Layer 1: Gray sandy/brittle material NAD SAT 41140.017-41 Tan quarry tile 2nd floor, Solarium Layer 1: Tan hard/brittle material NAD SATMortarLayer 2: Gray sandy/brittle material NAD 41140.017-42 Grout associated with 1" ceramic Room 312 Layer 1: Gray sandy/brittle material NAD SATfloor tile 41140.017-43 Grout associated with 1" ceramic Northeast Bath 2 Layer 1: Gray sandy/brittle material NAD SATfloor tile 41140.017-44 Mortar associated with 1" ceramic Room 312 Layer 1: Gray sandy/brittle material NAD SATfloor tile 41140.017-45 1" ceramic floor tile Southeast Shower 1, northeast Layer 1: White ceramic NAD SATGray mortar Layer 2: Gray brittle/sandy material NAD 41140.017-46 Mortar associated with 1" ceramic Northeast Bath 2 Layer 1: Gray sandy/brittle material NAD SATfloor tile 41140.017-47 Yellow mastic associated with 4" Southeast Shower 1 Layer 1: Yellow mastic NAD SATceramic wall tile 41140.017-48 Grout associated with 4" ceramic Room 312 Layer 1: White ceramic NAD SATwall tile Layer 2: Gray/light gray sandy/brittle material NAD 41140.017-49 Mortar associated with 4" ceramic Northeast Shower 2 Layer 1: White ceramic NAD SATwall tile Layer 2: Gray brittle/sandy material NAD October 30, 2023 NAD - No Asbestos Detected 4 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-50 Grout associated with 4" ceramic Room 312 Layer 1: White brittle material NAD SATwall tile 41140.017-51 Grout associated with 4" ceramic Southeast Shower 1 Layer 1: White brittle material NAD SATwall tile 41140.017-52 Grout associated with 4" ceramic Northeast Shower Room 2 Layer 1: White brittle material NAD SATwall tile 41140.017-53 4" brown cove base 3rd floor, west corridor Layer 1: Brown rubbery material NAD SATDark brown cove base mastic Layer 2: Dark brown mastic NAD 41140.017-54 6" gray cove base Corridor between SE-8 and SE-7 Layer 1: Gray rubbery material NAD SATBrown cove base mastic Layer 2: Brown mastic NAD 41140.017-55 6" gray cove base NE-20, south Layer 1: Gray rubbery material NAD SATTan cove base mastic Layer 2: Tan/brown mastic NADBrown cove base mastic 41140.017-56 6" gray cove base Basement, Scullery, north Layer 1: Gray rubbery material NAD SATCream cove base mastic Layer 2: Cream mastic NAD 41140.017-57 6" gray cove base 2nd floor at elevator Layer 1: Gray rubbery material NAD SATTan cove base mastic Layer 2: Tan mastic NAD 41140.017-58 Black threshold material Northeast Bath 2 Layer 1: Black/dark green brittle material NAD SAT 41140.017-59 Brown fiberglass reinforced plastic Southeast corridor at SE-9 Layer 1: Brown mastic NAD SATpanel mastic 41140.017-60 Brown fiberglass reinforced plastic Northeast corridor, south wall at Layer 1: Brown mastic NAD SATpanel mastic Northeast Bath 1 41140.017-61 Cream fiberglass reinforced Outside of Kitchen 3 Layer 1: Off-white mastic NAD SATplastic panel mastic 41140.017-62 Tan fiberglass reinforced plastic 2nd floor at Kitchen Door Layer 1: Tan/yellow mastic with paint NAD SATpanel mastic Layer 2: Trace white powdery material with paint NAD October 30, 2023 NAD - No Asbestos Detected 5 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-63 Cream fiberglass reinforced Basement, Scullery, south wall Layer 1: Off-white mastic NAD SATplastic panel mastic on concrete Layer 2: Gray sandy/brittle material NAD 41140.017-64 Yellow mastic behind corkboard strip SE-21 Layer 1: Yellow mastic NAD SAT 41140.017-65 Yellow mastic behind corkboard strip NE-10, southeast Layer 1: Yellow mastic NAD SATLayer 2: Trace brown wood debris NAD 41140.017-66 Yellow mastic on back of wardrobe SE-12 Layer 1: Yellow mastic NAD SAT 41140.017-67 Yellow mastic on back of wardrobe NE-18, center Layer 1: Yellow mastic NAD SAT 41140.017-68 Black sink undercoat Northeast Laundry, southwest Layer 1: Black soft/loose material 3% Chrysotile SAT 41140.017-69 Black sink undercoat Southeast Laundry, northwest Layer 1: Black soft/loose material 3% Chrysotile SAT 41140.017-70 Black sink undercoat 1st floor, east wing, Medication Layer 1: Black soft/loose material 3% Chrysotile SATRoom 41140.017-71 Black sink undercoat Room 315 Layer 1: Black soft/loose material 3% Chrysotile SAT 41140.017-72 Gray sink undercoat Room 310 Layer 1: Gray soft/loose material NAD SAT 41140.017-73 Joint compound 2nd floor, corridor at Staff Restroom Layer 1: White powdery material with paint NAD SATGypsum wallboard Layer 2: White chalky material with paper NAD 41140.017-74 White skim coat on plaster ceiling 1st floor, southeast Day Space Layer 1: White brittle material with paint NAD SATLayer 2: Gray sandy/brittle material NAD 41140.017-75 White skim coat on plaster wall 1st floor, southeast corridor at SE-19 Layer 1: White brittle material with paint NAD SATLayer 2: Gray sandy/brittle material NAD 41140.017-76 White skim coat on plaster wall 1st floor, east, storage west of Layer 1: White brittle material with paint NAD SATelevatorLayer 2: Gray sandy/brittle material NAD 41140.017-77 White skim coat on plaster wall NE-19, northeast Layer 1: White brittle material with paint NAD SATLayer 2: Gray sandy/brittle material NAD October 30, 2023 NAD - No Asbestos Detected 6 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-78 White skim coat on plaster wall Northeast corridor at NE-10 Layer 1: White brittle material with paint NAD SATLayer 2: Gray sandy/brittle material NAD 41140.017-79 White skim coat on plaster wall 3rd floor, corridor at kitchen Layer 1: White brittle material with paint NAD SATLayer 2: Gray sandy/brittle material NAD 41140.017-80 White skim coat on plaster wall 3rd floor, Solarium Layer 1: White brittle material with paint NAD SATLayer 2: Gray sandy/brittle material NAD 41140.017-81 Thick texture on ceiling Northeast Bath 2, center Layer 1: White powdery material with paint 2% Chrysotile SAT 41140.017-82 Thick texture on ceiling Northeast Bath 1 Layer 1: White powdery material with paint 2% Chrysotile SAT 41140.017-83 Thick texture on ceiling Southeast Bath 1 Layer 1: White powdery material with paint 2% Chrysotile SAT 41140.017-84 12" pinhole acoustic ceiling tile NE-18, center Layer 1: Gray fibrous material with paint NAD SATTan mastic Layer 2: Brown mastic with paint NAD 41140.017-85 12" fissure pinhole acoustic ceiling tile NE-18, center Layer 1: Gray fibrous material with paint NAD SATWhite glue dot Layer 2: White powdery material NAD 41140.017-86 12" fissure pinhole acoustic ceiling tile SE-3, center Layer 1: Gray fibrous material with paint NAD SATTan mastic Layer 2: Yellow mastic NADBeige mastic 41140.017-87 12" acoustic ceiling tile 1st floor, east wing at Nurses' Layer 1: Brown fibrous material with paint NAD SATBrown mastic Station Layer 2: Brown mastic NAD 41140.017-88 12" acoustic ceiling tile 2nd floor, room at end of east Layer 1: Brown fibrous material with paint NAD SATTan mastic corridor Layer 2: Brown mastic NADBrown mastic 41140.017-89 Concrete masonry unit mortar Basement corridor at Room 23 Layer 1: Gray sandy/brittle material with paint NAD SAT 41140.017-90 Concrete masonry unit mortar Basement corridor at Room 23 Layer 1: Gray sandy/brittle material with paint NAD SAT 41140.017-91 Red firestop Basement , Room 1, south Layer 1: Red soft/elastic material NAD SAT 41140.017-92 Gray duct sealant Room 19 Layer 1: Gray brittle material NAD SAT October 30, 2023 NAD - No Asbestos Detected 7 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-93 Yellow mastic on metal duct Basement, west hall, at Room 20 Layer 1: Yellow mastic NAD SAT 41140.017-94 Yellow mastic on metal duct 1st floor crawlspace Layer 1: Yellow mastic NAD SAT 41140.017-95 Fibrous wrap on column seam Basement, Room 18, east Layer 1: Off-white woven fibrous material NAD SATLayer 2: Yellow mastic NAD 41140.017-96 Fiberglass wrap with black mastic 1st floor crawlspace Layer 1: Yellow fibrous material NAD SATLayer 2: Silver foil NADLayer 3: Tan paper with black mastic NAD 41140.017-97 Black hanger mastic on metal duct Basement hallway near Room 6 Layer 1: Black brittle material 3% Chrysotile SAT 41140.017-98 Black hanger mastic on metal duct Basement, west hall at Room 20 Layer 1: Black brittle material 3% Chrysotile SAT 41140.017-99 Black expansion joint in concrete Basement, east hall by Room 8 Layer 1: Black soft/elastic material with debris NAD SATmasonry unit wall 41140.017-100 White sealant at pipe penetration in 1st floor Southeast Utility, southwest Layer 1: White soft/elastic material NAD SATfloor 41140.017-101 White sealant between sink and Southeast Laundry Room, northwest Layer 1: White soft/elastic material with paint NAD SATcounter 41140.017-102 White sealant between sink and Northeast Laundry Room, southwest Layer 1: White soft/elastic material with debris NAD SATcounter 41140.017-103 White caulk on gypsum wallboard Ceiling hatch in Southeast Home Layer 1: White brittle material NAD SATpanelRoom 41140.017-104 White caulk between acoustic Room SE-11 Layer 1: Off-white soft/elastic material with paint NAD SATceiling tile and wall 41140.017-105 Hard mudded fitting 1st floor, ceiling hatch in Southeast Layer 1: Off-white woven fibrous material NADHome Room Layer 2: White powdery material 6% Chrysotile 5% Amosite October 30, 2023 NAD - No Asbestos Detected 8 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-106 Hard mudded fitting 1st floor, ceiling hatch in Northeast Layer 1: Off-white woven fibrous material NAD SATExercise Room Layer 2: White powdery material 5% Chrysotile 4% Amosite 41140.017-107 Hard mudded fitting on 6" Room 8 Layer 1: Off-white woven fibrous material NAD SATfiberglass straight run Layer 2: White powdery material 8% Chrysotile 3% AmositeLayer 3: Off-white woven fibrous material NADLayer 4: White powdery material NAD 41140.017-108 Hard mudded fitting on 6" hard Basement, west hall Layer 1: Off-white woven fibrous material NAD SATstraight run Layer 2: White powdery material 10% Chrysotile 7% Amosite 41140.017-109 6" hard straight run insulation Basement hall at Room 18, south Layer 1: Off-white woven fibrous material NAD SATLayer 2: White powdery material 11% Chrysotile 8% Amosite 41140.017-110 6" hard straight run insulation Basement, west hall Layer 1: Off-white woven fibrous material NAD SATLayer 2: White powdery material 6% Chrysotile 15% Amosite 41140.017-111 6" hard straight run insulation Basement, west hall at Room 19 Layer 1: Off-white woven fibrous material NAD SATLayer 2: White powdery material 12% Chrysotile 10% Amosite 41140.017-112 Hard mudded fitting on 4" straight run Basement, near room 18 Layer 1: Off-white woven fibrous material NAD SATLayer 2: White powdery material 10% Chrysotile 9% Amosite 41140.017-113 Hard mudded fitting on 4" straight run Basement, west hall at Room 18 Layer 1: Off-white woven fibrous material NAD SATLayer 2: White powdery material 13% Chrysotile 8% Amosite 41140.017-114 Hard mudded fitting on 4" straight run Basement, west hall at Room 19 Layer 1: Off-white woven fibrous material NAD SATLayer 2: White powdery material 11% Chrysotile 7% Amosite 41140.017-115 Hard mudded fitting on 4" Basement hall at Room 12 Layer 1: Silver foil NAD SAT October 30, 2023 NAD - No Asbestos Detected 9 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab fiberglass straight run Layer 2: Tan paper with mastic and woven NADfibrous materialLayer 3: Yellow fibrous material NAD 41140.017-116 Hard mudded fitting on 4" Basement, Room 2 Layer 1: Silver foil NAD SATfiberglass straight run Layer 2: Tan paper with mastic and woven NADfibrous materialLayer 3: Yellow fibrous material NAD 41140.017-117 Hard mudded fitting on 4" Basement, Room 1 Layer 1: Off-white woven fibrous material NAD SATfiberglass straight run Layer 2: White powdery material 13% Chrysotile 8% AmositeLayer 3: Off-white woven fibrous material NADLayer 4: White powdery material 9% Chrysotile 6% Amosite 41140.017-118 Soft white window frame caulk NE-3, north wall, center Layer 1: White soft/elastic material with paint NAD SAT 41140.017-119 Soft white window frame caulk SE-20, north wall, west Layer 1: White soft/elastic material with paint NAD SAT 41140.017-120 Soft gray window putty SE-20, north wall, west Layer 1: Brown soft material with paint 4% Chrysotile SAT 41140.017-121 Soft black window putty NE-3, north wall, center Layer 1: Black soft/elastic material with paint NAD SATand debris 41140.017-122 Hard brown window frame caulk NE-2, south wall, center Layer 1: Brown hard brittle material with paint NAD SAT 41140.017-123 Exterior window frame sealant South elevation of northeast wing Layer 1: Gray soft material with paint 3% Chrysotile SAT 41140.017-124 Exterior window frame sealant East elevation of northeast wing Layer 1: Gray soft material with paint 3% Chrysotile SAT 41140.017-125 Interior gray window putty Divider between east wing Day Layer 1: Gray brittle material with paint NAD SATRooms 41140.017-126 Interior gray window frame caulk 1st floor, northeast Exercise Room Layer 1: Gray soft material with paint 2% Chrysotile SAT 41140.017-127 Interior gray window frame caulk 1st floor, northeast Exercise Room Layer 1: Gray soft material with paint 2% Chrysotile SAT 41140.017-128 Soft gray window putty NE-2, south wall, center Layer 1: Gray soft material with paint 4% Chrysotile SAT October 30, 2023 NAD - No Asbestos Detected 10 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-129 Exterior window glazing Southwest corner of southeast wing Layer 1: Gray brittle material with paint NAD SAT 41140.017-130 Gray exterior window glazing Northeast wing, east elevation Layer 1: Trace gray brittle material with paint NAD SAT 41140.017-131 Interior window glazing 2nd floor, Utility Room in east wing Layer 1: Gray brittle material NAD SAT 41140.017-132 Interior gray and white door frame 1st floor dining Layer 1: Off-white soft/elastic material with NAD SATcaulkgray paint 41140.017-133 Panel below window East elevation of Southeast wing, Layer 1: Trace gray fibrous material with paint 35% Chrysotile SATunder covered area 41140.017-134 Panel above window East elevation of Northeast wing, Layer 1: Trace gray fibrous material with paint 28% Chrysotile SATunder covered area 41140.017-135 Sealant between wall and column Southeast wing, north elevation Layer 1: Gray soft/elastic material with paint NAD SAT 41140.017-136 Mortar between terracotta blocks South driveway at main entrance Layer 1: Gray sandy/brittle material with paint NAD SAT 41140.017-137 Plaster on concrete Southeast wing, south elevation, west Layer 1: Gray sandy/brittle material with paint NAD SAT 41140.017-138 Plaster on concrete Southeast wing, south elevation, west Layer 1: Gray sandy/brittle material with paint NAD SAT 41140.017-139 Plaster on concrete Southeast wing, south elevation, west Layer 1: Gray sandy/brittle material with paint NAD SAT 41140.017-140 White sealant on fasteners Roof, bottom edge of penthouse, Layer 1: Gray soft/elastic material NAD SATsoutheast room 41140.017-141 White sealant on roof vent Roof, east wing, southwest edge Layer 1: White/gray soft material NAD SAT 41140.017-142 White sealant on roof vent Northeast roof edge Layer 1: White soft/elastic material NAD SAT 41140.017-143 Black sealant on roof vent Southeast corner of center core Layer 1: Black soft/elastic material NAD SAT 41140.017-144 Black sealant on roof vent Southwest edge of center core Layer 1: Black soft/elastic material NAD SAT 41140.017-145 Gray sealant behind fiberglass wall Roof fan room, 2nd furthest south Layer 1: Gray/off-white soft/elastic material NAD SATinsulation October 30, 2023 NAD - No Asbestos Detected 11 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-146 Brown sealant on roof flashing Northeast corner of center core Layer 1: Brown/dark gray soft/elastic material NAD SATwith trace paint 41140.017-147 Asphaltic roofing Center core, west wing, center Layer 1: Black asphaltic material NAD SATLayer 2: Black asphaltic fibrous material NADLayer 3: Black asphaltic material NAD 41140.017-148 Asphaltic roofing Center core, east wing Layer 1: Black asphaltic material NAD SATLayer 2: Black asphaltic fibrous material NADLayer 3: Black asphaltic material NADLayer 4: Yellow fibrous material NAD 41140.017-149 Asphaltic roofing Roof over north covered bridge Layer 1: Black asphaltic material NAD SATLayer 2: Black asphaltic fibrous material NADLayer 3: Black asphaltic material NAD 41140.017-150 Styrofoam Center core, center, south of Layer 1: White foamy material NAD SATAsphaltic roofing penthouses Layer 2: Black asphaltic material NADLayer 3: Black asphaltic fibrous material NADLayer 4: Black asphaltic material NAD 41140.017-151 Asphaltic roofing East wing, center zig zag roof Layer 1: Black asphaltic material with sand NAD SATBrown fiberboard Layer 2: Black asphaltic material NADLayer 3: Black asphaltic fibrous material NADLayer 4: Black asphaltic material NADLayer 5: Black asphaltic fibrous material NADLayer 6: Black asphaltic material NADLayer 7: Yellow fibrous material NAD 41140.017-152 Asphaltic roofing Northeast wing, west Layer 1: Black asphaltic fibrous material NAD SATLayer 2: Black asphaltic material NADLayer 3: Yellow fibrous material NAD 41140.017-153 Asphaltic roofing Northeast wing, east Layer 1: Black asphaltic material NAD SATLayer 2: Black asphaltic fibrous material NADLayer 3: Black asphaltic material NADLayer 4: Yellow fibrous material NAD October 30, 2023 NAD - No Asbestos Detected 12 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-154 Asphaltic roofing Southeast wing, west Layer 1: Black asphaltic material NAD SATLayer 2: Black asphaltic fibrous material NADLayer 3: Black asphaltic material NADLayer 4: Black asphaltic fibrous material NADLayer 5: Black asphaltic material NADLayer 6: Trace white foamy material NAD 41140.017-155 Asphaltic roofing Southeast wing, east Layer 1: Black asphaltic material NAD SATLayer 2: Black asphaltic fibrous material NADLayer 3: Black asphaltic material NADLayer 4: Yellow fibrous material NADLayer 5: Trace white foamy material NAD 41140.017-156 Concrete masonry unit mortar Southeast wing, wall hatch at Layer 1: Off-white sandy/brittle material NAD SATrestrooms 41140.017-157 Black waterproofing East wing, floor hatch in center Layer 1: Black asphaltic material NAD SATUtility roof, east wall of elevatorshaft 41140.017-158 Black mastic on fiberglass straight Northeast wing, wall hatch at Layer 1: Yellow mastic NAD SATrunrestrooms Layer 2: Silver foil NADLayer 3: Tan paper with black mastic NAD 41140.017-159 Black mastic on fiberglass straight Southeast wing, east custodial Layer 1: Silver foil NAD SATruncloset, crawlspace Layer 2: Black mastic NADLayer 3: Yellow fibrous material NAD 41140.017-160 Black mastic on fiberglass straight Southeast wing, wall hatch at Layer 1: Silver foil NAD SATrunrestrooms Layer 2: Tan paper with black mastic NADLayer 3: Yellow mastic NAD 41140.017-161 Black mastic on fiberglass straight Southeast wing, Dining Area, Layer 1: Silver foil NAD SATruncrawlspaceLayer 2: Tan paper with black mastic NAD 41140.017-162 Yellow mastic behind fiberglass Southeast wing, Phone Room, Layer 1: Yellow/off-white mastic NAD SATduct insulation crawlspace Layer 2: Off-white fibrous material NAD October 30, 2023 NAD - No Asbestos Detected 13 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-163 Hard mudded fitting insulation on Southeast wing, wall hatch north Layer 1: Off-white woven fibrous material NAD SAT2" fiberglass straight run of drinking fountain Layer 2: White powdery material 4% Chrysotile 7% Amosite 41140.017-164 Hard mudded fitting insulation on Southeast wing, wall hatch north Layer 1: Off-white woven fibrous material NAD SAT2" fiberglass straight run of drinking fountain Layer 2: White powdery material 4% Chrysotile 8% Amosite 41140.017-165 Hard mudded fitting insulation on Southeast wing, in wall behind Layer 1: Off-white woven fibrous material NAD SAT2" fiberglass straight run drinking fountain Layer 2: White powdery material 3% Chrysotile 6% Amosite 41140.017-166 6" straight run thermal system East wing, center Utility Room, Layer 1: Off-white woven fibrous material with NAD SATinsulationcrawlspacepaintLayer 2: White powdery material 5% Chrysotile 7% Amosite 41140.017-167 6" straight run thermal system East wing, center Utility Room, Layer 1: Off-white woven fibrous material with NAD SATinsulationcrawlspacepaintLayer 2: White powdery material 8% Chrysotile 11% Amosite 41140.017-168 6" straight run thermal system East wing, center Utility Room, Layer 1: Off-white woven fibrous material with NAD SATinsulationcrawlspacepaintLayer 2: White powdery material 9% Chrysotile 9% Amosite 41140.017-169 4" straight run thermal system East wing, center Utility Room, Layer 1: Off-white woven fibrous material with NAD SATinsulationcrawlspacepaintLayer 2: White powdery material 11% Chrysotile 9% Amosite 41140.017-170 Sealant around cement asbestos Covered bridge at north elevation, Layer 1: Gray brittle material with paint 3% Chrysotile SATboard panel east 41140.017-171 Gray pebble pattern sheet vinyl Room 134 medical patient Layer 1: Debris NAD NVLWhite backing treatment Layer 2: Gray sheet vinyl NADYellow mastic Layer 3: Beige paper backing with soaked in NADtan brittle mastic October 30, 2023 NAD - No Asbestos Detected 14 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-172 Gray pebble pattern sheet vinyl Laundry 2nd floor core north Layer 1: Yellow/tan sheet vinyl with marble NAD NVLGray backing patternLayer 2: Off-white paper backing with soaked NADin white mastic 41140.017-173 Tan pebble pattern sheet vinyl Room 937, 2nd floor Isolation Layer 1: Tan sheet vinyl with marble pattern NAD NVLTan fuzzy backing Room Layer 2: Off-white paper backing with soaked NADin white mastic 41140.017-174 Gray sheet vinyl with blue spots Ground floor west wing kitchen Layer 1: White rubbery vinyl with green NAD NVLGray mastic floor speckles and covering transparent sheetGray leveling compound Layer 2: White brittle mastic with gray leveling NADsandy material 41140.017-175 Gray streaked sheet vinyl Ground floor west wing Dining Layer 1: Debris NAD NVLYellow mastic Room Layer 2: Beige rubbery vinyl NADLayer 3: Tan brittle mastic NAD 41140.017-176 Gray rubber flooring Ground floor NW wing reception Layer 1: Gray rubbery vinyl NAD NVLWhite mastic area Layer 2: White brittle mastic with gray leveling NADsandy material 41140.017-177 9" Green and white streaked vinyl Room 933 Floor 2 Layer 1: Green rubbery vinyl NAD NVLfloor tile Layer 2: Tan brittle mastic NADYellow mastic 41140.017-178 Carpet Room 930 2nd floor general Layer 1: Multi-colored fibrous material with NAD NVLYellow mastic storage white plastic mesh Brown sheet vinyl Layer 2: White and yellow brittle mastic with NADYellow mastic white fibrous/plastic meshLayer 3: Brown rubbery vinyl NADLayer 4: Tan brittle mastic NAD 41140.017-179 12" white vinyl floor tile Ground floor NW wing at NW-10 Layer 1: Debris on tile corner NAD NVL(replacement)Layer 2: White vinyl tile NADDark yellow mastic Layer 3: Dark yellow soft mastic NAD 41140.017-180 9" brown vinyl floor tile Ground floor NW wing Room Layer 1: Brown vinyl tile 2% Chrysotile NVLBlack mastic SW-21 Layer 2: Black asphaltic mastic with debris 3% Chrysotile October 30, 2023 NAD - No Asbestos Detected 15 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-181 Yellow carpet mastic 1st floor central core counseling Layer 1: Yellow brittle mastic NAD NVL9" gray vinyl floor tile office Layer 2: Gray vinyl tile 2% ChrysotileBlack mastic Layer 3: Black asphaltic mastic NAD 41140.017-182 Brown sheet vinyl with streaks Room 907 Nurse's station Floor 2 Layer 1: Brown rubbery vinyl NAD NVLYellow mastic central core Layer 2: Tan brittle mastic NADBrown flooring (poured)Layer 3: Gray sandy material NAD 41140.017-183 Brown flooring (poured)Ground floor NW Dining Room Layer 1: Tan soft mastic with gray sandy NAD NVLunder brown sheet vinyl materialLayer 2: Brown sandy material NADLayer 3: Gray cementitious material NAD 41140.017-184 Brown flooring (poured)Floor 2 corridor 938 under tan Layer 1: Tan brittle mastic with brown and NAD NVLsheet vinyl gray sandy material 41140.017-185 Yellow carpet mastic 2nd floor solarium Layer 1: Yellow brittle mastic with gray NAD NVLGray leveling compound leveling sandy material 41140.017-186 Gray leveling compound Floor 2 SW Day Room Layer 1: Gray leveling sandy material NAD NVL 41140.017-187 9" white vinyl floor tile Room SW-22 Layer 1: Off-white vinyl tile 3% Chrysotile NVLBlack mastic Layer 2: Black asphaltic mastic with debris 4% Chrysotile 41140.017-188 4" Gray covebase Ground floor west wing clerks Layer 1: Gray rubbery material NAD NVLTan mastic office Layer 2: White brittle mastic with debris NAD 41140.017-189 Brown covebase 2nd floor Quiet Room opposite Layer 1: Brown rubbery material with adhesive NAD NVLYellow mastic Room 906 Layer 2: Tan brittle mastic NAD 41140.017-190 Gray wall plaster Ground floor west wing clerks Layer 1: Gray/white sandy crumbly material NAD NVLoffice 41140.017-191 Gray wall plaster 1st floor west Wind Hall Layer 1: Gray sandy material NAD NVL 41140.017-192 White plaster 1st floor Counseling office Layer 1: White sandy material with paint NAD NVLGray plaster Layer 2: Gray sandy material NAD October 30, 2023 NAD - No Asbestos Detected 16 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-193 Gray window putty Ground floor clerk office interior Layer 1: Gray rubbery material NAD NVLwindow 41140.017-194 White laminate with gold sparkles Ground floor Med room west Layer 1: Laminate off-white color with golden NAD NVLYellow mastic wing speckles, yellow adhesive and tan fibrous material 41140.017-195 White laminate and clear mastic Ground floor west wing reception Layer 1: Laminate white color with tan NAD NVLadhesive 41140.017-196 Composite joint compound and 2nd floor west wing hall 910 Layer 1: White compacted powdery material NAD NVLgypsum wallboard Layer 2: White chalky material with paper NAD 41140.017-197 1" white ceramic floor tile Ground floor NW wing restroom Layer 1: White ceramic tile NAD NVLGray grout next to reception Layer 2: Gray cementitious material NAD 41140.017-198 1" white ceramic floor tile Ground floor west wing shower Layer 1: White ceramic tile NAD NVLGray grout room Layer 2: Gray cementitious material with NADfibers debris 41140.017-199 Blue ceramic wall tile 2nd floor shower 925 Layer 1: Blue ceramic tile NAD NVLGroutLayer 2: Gray cementitious material with NADdebris 41140.017-200 12" white ceiling tile Ground floor west wing dining Layer 1: Brown brittle mastic with tan NAD NVLBrown mastic area fibrous material 41140.017-201 12" white ceiling tile Ground floor west wing Room Layer 1: Beige fibrous material with thin white NAD NVLYellow mastic SW-5 powdery material and white paintLayer 2: Yellow brittle mastic NAD 41140.017-202 12" white ceiling tile Ground floor west wing NW-16 Layer 1: Beige fibrous material with thin white NAD NVLYellow mastic powdery material and white paintLayer 2: Yellow brittle mastic NAD 41140.017-203 12" white ceiling tile 1st floor hall central core Layer 1: Tan compressed fibrous material with NAD NVL Brown mastic thin texture material and white paintLayer 2: Brown brittle mastic NAD October 30, 2023 NAD - No Asbestos Detected 17 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-204 12" white ceiling tile 2nd floor central core kitchen Layer 1: Tan compressed fibrous material with NAD NVLlarge holes - nailed in behind nurse's station thin white powdery material and white paint 41140.017-205 Black sink undercoat 2nd floor west wing medication Layer 1: Black asphaltic crumbly material 2% Chrysotile NVLroom 41140.017-206 Yellow mastic behind FRP Ground floor west wing shower Layer 1: Yellow brittle mastic with fibers NAD NVLwainscotroom 2 debris 41140.017-207 Yellow mastic behind FRP Ground floor west wing hall Layer 1: Yellow brittle mastic with sandy NAD NVLwainscotmaterial and paint 41140.017-208 Texture on concrete wall Stairwell #2 Layer 1: Crumbly white sandy material with NAD NVLpaint 41140.017-209 Texture on concrete wall Stairwell #2 Layer 1: Crumbly white sandy material with NAD NVLpaint 41140.017-210 Texture on concrete wall Stairwell #3 Layer 1: Crumbly white sandy material with NAD NVLpaint 41140.017-211 Ceiling texture Room 230 toilets Layer 1: Crumbly white compacted texture 3% Chrysotile NVLmaterial with paint 41140.017-212 Ceiling texture Room 130 toilets Layer 1: Crumbly white/tan compacted 4% Chrysotile NVLtexture material with paint 41140.017-213 Ceiling texture Room 130 toilets Layer 1: Crumbly off-white compacted 3% Chrysotile NVLtexture material with paint 41140.017-214 Texture on concrete wall NW elevation west wing Layer 1: Crumbly thin gray cementitious NAD NVLmaterial with beige, light gray and yellow paint 41140.017-215 Texture on concrete wall SW elevation SW wing Layer 1: Crumbly thin gray cementitious NAD NVLmaterial with beige, light gray and yellow paint October 30, 2023 NAD - No Asbestos Detected 18 of 19 Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 PLM ASBESTOS SAMPLE INVENTORY PBS Sample #Material Type Sample Location Lab Description Lab Result Lab 41140.017-216 Texture on concrete wall NW elevation NW wing Layer 1: Crumbly thin gray cementitious NAD NVLmaterial with beige, light gray and yellow paint 41140.017-217 Texture on wall Floor 1 Room 225 Layer 1: White compacted texture material NAD NVLwith gray paint Layer 2: Thin white sandy material with NADred/beige paint 41140.017-218 Texture on wall Floor 1 Room 225 Layer 1: White compacted texture material NAD NVLwith gray paint Layer 2: Thin white sandy material with NADred/beige paint 41140.017-219 Texture on wall Floor 1 Room 225 Layer 1: White compacted texture material NAD NVLwith gray paint Layer 2: Thin white sandy material with NADred/beige paint 41140.017-220 Black rubber roofing Roof over west patient wing Layer 1: Black asphaltic fibrous material NAD NVLWhite Styrofoam with granulesBlack asphaltic roofing Layer 2: White soft material NADLayer 3: Black rubbery sheet NAD 41140.017-221 TSI debris on the back of ceiling 1st floor hall above ceiling tiles Layer 1: White chalky material with paper NAD NVLtilesLayer 2: White gray fibrous sandy material 16% Chrysotile 41140.017-222 Hard insulation on pipe elbow On water line above 1st floor Layer 1: White woven fibers NAD NVLceiling Room 219 Layer 2: White gray fibrous sandy material 24% Chrysotile 41140.017-223 Hard insulation on roof drain elbow 1st floor hall above the ceiling Layer 1: White woven fibers NAD NVLLayer 2: White gray fibrous sandy material 38% Amosite October 30, 2023 NAD - No Asbestos Detected 19 of 19 APPENDIX B AA Lead Paint Chip Sampling Information AA Lead Paint Chip Sample Inventory AA Lead Paint Chip Laboratory Data Sheets AA Lead Paint Chip Chain of Custody Documentation Port of Skagit SWIFT Center Douglas Building PBS Engineering + Environmental PBS Project #41140.017 AA LEAD PAINT CHIP SAMPLE INVENTORY PBS Sample #Paint Color / Component or Substrate Sample Location Results (mg/kg)Results (%)Lab 41140.017-Pb01 White / Concrete / Wall Center core, roof, north elevation of penthouse <54 <0.0054 NVL 41140.017-Pb02 White / Metal / Trim Center core, roof, east elevation of penthouse <52 <0.0052 NVL 41140.017-Pb03 Off-white / Concrete / Wall Northeast wing, south elevation <53 <0.0053 NVL 41140.017-Pb04 Red / Wood / Door Northeast wing, north elevation <56 <0.0056 NVL 41140.017-Pb05 Brown / Metal / Flashing Southeast wing, southwest 180 0.018 NVL 41140.017-Pb06 Red / Metal / Flashing Northeast wing, north 130 0.013 NVL 41140.017-Pb07 Yellow / Concrete masonry unit / Wall Basement, hallway at Room 23 160 0.016 NVL 41140.017-Pb08 White / Plaster / Wall NE-14, northeast <52 <0.0052 NVL 41140.017-Pb09 White / Concrete / Wall Northeast wing Day Space, northwest <55 <0.0055 NVL 41140.017-Pb10 White / Concrete / Wall SE-19, north wall 290 0.029 NVL 41140.017-Pb11 White / Concrete / Wall 3rd floor, room at end of east corridor 1100 0.11 NVL 41140.017-Pb12 Pink / Plaster / Wall West wing storage 720 0.072 NVL 41140.017-Pb13 White / Gypsum wallboard / Wall West wing SW16 1900 0.19 NVL 41140.017-Pb14 Gray / Plaster / Wall West wing 1st floor office 210 0.021 NVL 41140.017-Pb15 Blue / Wood / Door Northwest wing Bath 1 door <160 <0.016 NVL 41140.017-Pb16 Brown / Wood / Counter Northwest wing dining room counter <480 <0.048 NVL 41140.017-Pb17 Blue / Concrete / Stair Stairwell 2 <120 <0.012 NVL October 30, 2023 mg/kg = Milligrams per kilogram < = Less than the Limit of Detection 1 of 1 Sincerely, Nick Ly, Technical Director RE: Total Metal Analysis Method: EPA 7000B Lead by FAA <paint> Item Code: FAA-02 August 30, 2021 PBS Environmental - Seattle Kaitlin Soukup 214 E Galer St. Suite. 300 Seattle, WA 98102 Enc.: Sample results NVL Batch # 2115243.00 Client Project: 41140.017 Location: SWIFT Center - Douglas Building Dear Ms. Soukup, NVL Labs received 11 sample(s) for the said project on 8/27/2021. Preparation of these samples was conducted following protocol outlined in EPA 3051/7000B , unless stated otherwise. Analysis of these samples was performed using analytical instruments in accordance with EPA 7000B Lead by FAA <paint>. The results are usually expressed in mg/Kg and percentage (%). Test results are not blank corrected. For recent regulation updates pertaining to current regulatory levels or permissible exposure levels, please call your local regulatory agencies for more detail. At NVL Labs all analyses are performed under strict guidelines of the Quality Assurance Program. This report is considered highly confidential and will not be released without your approval. Samples are archived after two weeks from the analysis date. Please feel free to contact us at 206-547-0100, in case you have any questions or concerns. page 1 of 4 Analysis Report Total Lead (Pb) SWIFT Center - Douglas Building PBS Environmental - SeattleClient: 214 E Galer St. Suite. 300 Seattle, WA 98102 Ms. Kaitlin SoukupAttention: Address: Project Location:Samples Received: 11 Samples Analyzed: 11 Client Project #: 41140.017 Batch #: 2115243.00 Date Received: 8/27/2021 Lab ID Client Sample # Sample Weight (g) Results in mg/Kg Results in percent RL in mg/Kg Matrix: Paint Method: EPA 3051/7000B 21098619 41140.017-Pb01 0.1866 54 <54 0.0054< 21098620 41140.017-Pb02 0.1906 52 <52 0.0052< 21098621 41140.017-Pb03 0.1870 53 <53 0.0053< 21098622 41140.017-Pb04 0.1788 56 <56 0.0056< 21098623 41140.017-Pb05 0.1893 53 180 0.018 21098624 41140.017-Pb06 0.1802 55 130 0.013 21098625 41140.017-Pb07 0.1987 50 160 0.016 21098626 41140.017-Pb08 0.1913 52 <52 0.0052< 21098627 41140.017-Pb09 0.1810 55 <55 0.0055< 21098628 41140.017-Pb10 0.1914 52 290 0.029 21098629 41140.017-Pb11 0.1897 53 1100 0.11 FAA-02 ClientSampled by: Shalini PatelAnalyzed by: Nick LyReviewed by: 08/30/2021Date Analyzed: 08/30/2021Date Issued: Bench Run No:2021-0830-02 mg/ Kg =Milligrams per kilogram RL = Reporting Limit Percent = Milligrams per kilogram / 10000 '<' = Below the reporting Limit Note : Method QC results are acceptable unless stated otherwise. Unless otherwise indicated, the condition of all samples was acceptable at time of receipt. Nick Ly, Technical Director page 2 of 4 PBS Environmental - Seattle 2115243.00 11 Company NVL Batch Number Total Number of Samples SWIFT Center - Douglas Building 1 DayTAT 8/30/2021Due Date 11:45 AMTime (866) 727-0140Fax kaitlin.soukup@pbsusa.comEmail Project Manager Ms. Kaitlin Soukup (206) 233-9639Phone Rush Samples Rush TAT NoAH 41140.017Project Name/Number:Project Location: Sample ID Description A/RLab ID LEAD LABORATORY SERVICES Subcategory Item Code Flame AA (FAA) Metals FAA-02 EPA 7000B Lead by FAA <paint> 214 E Galer St. Suite. 300 Seattle, WA 98102 Address 41140.017-Pb011 A21098619 41140.017-Pb022 A21098620 41140.017-Pb033 A21098621 41140.017-Pb044 A21098622 41140.017-Pb055 A21098623 41140.017-Pb066 A21098624 41140.017-Pb077 A21098625 41140.017-Pb088 A21098626 41140.017-Pb099 A21098627 41140.017-Pb1010 A21098628 41140.017-Pb1111 A21098629 Office Use Only Print Name Company Date TimeSignature Faxed Emailed Company Date TimeSignature ClientSampled by Kelly AuVuReceived by CourierRelinquished by Shalini PatelAnalyzed by Results Called by NVL NVL 8/27/21 8/30/21 1145 Print Name Entered By: Kelly AuVu Date: 8/27/2021 Time: 11:59 AM Special Instructions: page 3 of 4 page 4 of 4 Sincerely, Shalini Patel, Manager Metals Lab RE:Total Metal Analysis Method: EPA 7000B Lead by FAA <paint> Item Code: FAA-02 October 11, 2023 PBS Environmental - Seattle Janet Murphy 214 E Galer St. Suite. 300 Seattle, WA 98102 Enc.: Sample results NVL Batch # 2316179.00 Client Project: 41140.017 Location: Douglas Building Core West Wing 2nd & 3rd Fl. Dear Ms. Murphy, NVL Labs received 6 sample(s) for the said project on 10/10/2023. Preparation of these samples was conducted following protocol outlined in EPA 3051/7000B , unless stated otherwise. Analysis of these samples was performed using analytical instruments in accordance with EPA 7000B Lead by FAA <paint>. The results are usually expressed in mg/Kg and percentage (%). Test results are not blank corrected. For recent regulation updates pertaining to current regulatory levels or permissible exposure levels, please call your local regulatory agencies for more detail. At NVL Labs all analyses are performed under strict guidelines of the Quality Assurance Program. This report is considered highly confidential and will not be released without your approval. Samples are archived after two weeks from the analysis date. Please feel free to contact us at 206-547-0100, in case you have any questions or concerns. page 1 of 4 Analysis Report Total Lead (Pb) Douglas Building Core West Wing 2nd & 3rd Fl. PBS Environmental - SeattleClient: 214 E Galer St. Suite. 300 Seattle, WA 98102 Ms. Janet MurphyAttention: Address: Project Location:Samples Received: 6 Samples Analyzed: 6 Client Project #: 41140.017 Batch #: 2316179.00 Date Received: 10/10/2023 Lab ID Client Sample # Sample Weight (g) Results in mg/Kg Results in percent RL in mg/Kg Matrix: Paint Method: EPA 3051/7000B 23097749 41140.017-Pb12 0.1983 50 720 0.072 23097750 41140.017-Pb13 0.1366 73 1900 0.19 23097751 41140.017-Pb14 0.2149 47 210 0.021 23097752 41140.017-Pb15 0.0631 160 <160 0.016< 23097753 41140.017-Pb16 0.0209 480 <480 0.048< 23097754 41140.017-Pb17 0.0845 120 <120 0.012< FAA-02 ClientSampled by: Yasuyuki HidaAnalyzed by: Shalini PatelReviewed by: 10/10/2023Date Analyzed: 10/11/2023Date Issued: Small sample size (<0.05g) for 41140.017-Pb16Comments: Bench Run No:2023-1010-07 mg/ Kg =Milligrams per kilogram RL = Reporting Limit Percent = Milligrams per kilogram / 10000 '<' = Below the reporting Limit Note : Method QC results are acceptable unless stated otherwise. Unless otherwise indicated, the condition of all samples was acceptable at time of receipt. Shalini Patel, Manager Metals Lab page 2 of 4 PBS Environmental - Seattle 2316179.00 6 Company NVL Batch Number Total Number of Samples Douglas Building Core West Wing 2nd & 3rd Fl. 3 DaysTAT 10/13/2023Due Date 10:15 AMTime (866) 727-0140Fax janet.murphy@pbsusa.comEmail Project Manager Ms. Janet Murphy (206) 233-9639 (206) 409-9904Cell Phone Rush Samples Rush TAT NoAH 41140.017Project Name/Number:Project Location: Sample ID Description A/RLab ID LEAD LABORATORY SERVICES Subcategory Item Code Flame AA (FAA) Metals FAA-02 EPA 7000B Lead by FAA <paint> 214 E Galer St. Suite. 300 Seattle, WA 98102 Address 41140.017-Pb121 A23097749 41140.017-Pb132 A23097750 41140.017-Pb143 A23097751 41140.017-Pb154 A23097752 41140.017-Pb165 A23097753 41140.017-Pb176 A23097754 Office Use Only Print Name Company Date TimeSignature Faxed Emailed Company Date TimeSignature ClientSampled by Kelly AuVuReceived by CourierRelinquished by Yasuyuki HidaAnalyzed by Results Called by NVL NVL 10/10/23 10/10/23 1015 Print Name Entered By: Fatima Khan Date: 10/10/2023 Time: 12:47 PM Special Instructions: page 3 of 4 page 4 of 4 APPENDIX C PBS Inspector Certifications 03/02/2024 03/02/2023 ASBESTOS INSPECTOR / MANAGEMENT PLANNER REFRESHER Course Date: Expiration Date:Certificate:IMR-23-8300A for Online, Course Location: For verification of the authenticity of this certificate contact: PBS Engineering and Environmental Inc. Andy Fridley, Instructor In accordance with TSCA Title II, Part 763, Subpart E, Appendix C of 40 CFR AHERA is the Asbestos Hazard Emergency Response Act enacting Title II of Toxic Substance Control Act (TSCA) HAS SUCCESSFULLY COMPLETED THE TRAINING COURSE JANET MURPHY THIS IS TO CERTIFY THAT CCB #SRA0615 4-Hr Training __________________________ 4412 S Corbett Avenue Portland, OR 97239 503.248.1939 Kaitlin M. Soukup AHERA Building Inspector This is to certify that 4 hours of online refresher training as an 179143 Certificate Number Instructor: Oct 14, 2020 Date(s) of Training Expires in 1 year. to comply with the training requirements of has satisfactorily completed TSCA Title II, 40 CFR 763 (AHERA) EPA Provider # 1085 N/AExam Score: (if applicable) Andre Zwanenburg EXHIBIT B Orange & Blue indicate areas authorized for interior damage.