HomeMy WebLinkAbout05-05-2026 Agenda Packet
Planning Commission
Regular Meeting
May 5, 2026 - 7:00 PM
City Hall Council Chambers
AGENDA
CALL TO ORDER
PUBLIC PARTICIPATION
A. The Planning Commission Meeting scheduled for Tuesday, May 5, 2026, at 7:00 p.m. will
be held in person and virtually.
Virtual Participation Link:
https://us06web.zoom.us/j/86985810812
Phone one-tap:
+12532050468,,86985810812# US
+12532158782,,86985810812# US (Tacoma)
Join via audio:
+1 253 205 0468 US
+1 253 215 8782 US (Tacoma)
877 853 5257 US Toll Free
888 475 4499 US Toll Free
Webinar ID: 869 8581 0812
PLEDGE OF ALLEGIANCE
ROLL CALL
AGENDA MODIFICATIONS
PUBLIC COMMENT
APPROVAL OF MINUTES
A. 04/07/26 Draft Minutes from the Regular Planning Commission Meeting
BUSINESS ITEM #1
A. City Clerks OPMA and Parliamentary Procedures
Staff Introduction/Presentation (Wood)
City Clerk to provide an overview of OPMA and Parliamentary Procedures
BUSINESS ITEM #2
A. Citywide Design Standards Update and Related Code Update
Staff Introduction/Presentation (Reed)
Page 1 of 289
Staff will present the proposed updates to the Citywide Design Standards and amended
code to Planning Commission for a recommendation to City Council.
B.Public Hearing
C.Deliberation and Vote
BUSINESS ITEM #3
A.Downtown Design Standards Update and Associated Zoning Code Update
Staff Introduction/Presentation (Tatro)
Staff will present the proposed updates to the Downtown Design Standards and amended
code to Planning Commission for a recommendation to City Council.
B.Public Hearing
C.Deliberation and Vote
BUSINESS ITEM #4
A.Density Bonus for Existing Buildings Code Update
Staff Introduction/Presentation (Goode)
The City of Auburn is updating the Density Bonus Code for Existing Buildings as required
under HB 1757. This update allows for the density bonuses awarded under Auburn City
Code 18.02.067 to expand to the Residential Conservancy Zone, the R-1 Residential Zone,
and the R-2 Residential Low Zone. Density bonuses awarded under this code section are
required to be within existing buildings and shall not expand the square footage of the
building or the building footprint.
B.Public Hearing
C.Deliberation and Vote
BUSINESS ITEM #5
A.Nonconforming Code Update
Staff Introduction/Presentation (Teague)
Staff to discuss an update to Chapter 18.54 “Nonconforming Structures, Land And Uses”.
COMMUNITY DEVELOPMENT REPORT
ADJOURNMENT
The City of Auburn Planning Commission is a seven member advisory body that provides
recommendations to the Auburn City Council on the preparation of and amendments to land use
plans and related codes such as zoning. Planning Commissioners are appointed by the Mayor and
confirmed by the City Council.
Actions taken by the Planning Commission, other than approvals or amendments to the Planning
Commission Rules of Procedure, are not final decisions; they are in the form of recommendations to
the City Council which must ultimately make the final decision.
Page 2 of 289
AGENDA BILL APPROVAL FORM
Agenda Subject: Meeting Date:
04/07/26 Draft Minutes from the Regular Planning Commission Meeting May 5, 2026
Department: Attachments: Budget Impact:
Community Development 04-07-2026 Minutes
Administrative Recommendation:
Background for Motion:
Background Summary:
See attached Minutes
Councilmember: Staff: Jason Krum
Page 3 of 289
Planning Commission
Regular Meeting
April 7, 2026 - 7:00 PM
City Hall Council Chambers
MINUTES
CALL TO ORDER
Chair Judi Roland called the meeting to order at 7:00 p.m. in the Council Chambers of
Auburn City Hall, 25 West Main Street.
PUBLIC PARTICIPATION
The Planning Commission Meeting was held in person and virtually.
PLEDGE OF ALLEGIANCE
Chair Roland led those in attendance in the Pledge of Allegiance.
ROLL CALL
Commissioners present: Chair Judi Roland, Vice Chair William Stewart, Julie Berry,
Lynn Walters, and Kirk Hiller. Commissioners Aaron Vanderpol and Ajay Ganesan were
excused.
Staff members present: Planning Services Manager Alexandria Teague, Senior Planner
Alyssa Tatro, Planner II Gabriel Clark, Senior City Staff Attorney Chandra Hein, and
Deputy City Clerk Rebecca Wood-Pollock.
AGENDA MODIFICATIONS
Business Item #3 (Citywide Design Standards Update and Related Code Update) and
Business Item #4 (Downtown Design Standards Update and Associated Zoning Code
Update) were removed from the agenda.
PUBLIC COMMENT
Bonnie Helms provided comments.
APPROVAL OF MINUTES
A.March 3, 2026 Draft Minutes from Regular Planning Commission Meeting
Commissioner Walters moved and Commissioner Hiller seconded to approve
the March 3, 2026, Planning Commission Meeting minutes.
MOTION CARRIED UNANIMOUSLY. 5-0
Page 4 of 289
BUSINESS ITEM #1
A.Critical Areas Ordinance Update
Staff Introduction/Presentation (Tatro)
Staff will present the proposed updates to the Critical Areas Ordinance,
Chapter 16.10 Auburn City Code (ACC) to Planning Commission for a
recommendation to City Council
Planner Tatro provided the Commission with a presentation on the Critical
Areas Ordinance Update, including its background and purpose, key
objectives, and an overview of each of the updates to the Code's sections,
including Definitions and Administration, Applicability, Exemptions and
Nonconforming Uses, Classification and Rating of Critical Areas, and Buffer
Areas and Setbacks. She also addressed geologic hazard areas, minimization
measures, mitigation framework and standards, stream regulations, site
potential tree height, existing and proposed stream buffers, vegetative
standards, comparisons to other jurisdictions, and a summary of the changes.
B.Public Hearing
Chair Roland opened the Public Hearing at 7:30 p.m.
Dylan Marcus provided comments.
Chair Roland closed the Public Hearing at 7:34 p.m.
C.Deliberation and Vote
The Commission discussed the Critical Areas Ordinance Update.
Vice Chair Stewart moved and Commissioner Walters seconded to
recommend to Council the proposed updates to the Critical Areas Ordinance
as recommended by staff.
MOTION CARRIED UNANIMOUSLY. 5-0
BUSINESS ITEM #2
A.Battery Energy Storage System (BESS) Code Update
Staff Introduction/Presentation (Clark)
Staff will present the proposed development standards and land use approval
pathways for BESS to Planning Commission for a recommendation to City
Council.
Planner Clark shared a presentation with the Commission on the Battery
Energy Storage System (BESS) Code Update, including its purpose, applicable
sections of the City Code, applicable regulations, an overview of the tiered
system and zoning classifications, public feedback and concerns, and staff
recommendations.
Page 5 of 289
The Commission discussed firefighter protocol for thermal events and incident
mitigation plans, Valley Regional Fire Authority (VRFA) resources and staffing,
differences in safety between the different tiers, battery certifications,
separation requirements, the steps in the application process, power
substations, noise pollution, the BESS moratorium, and expressed interest in
forming an ad hoc committee to do further research regarding BESS safety.
B.Public Hearing
Chair Roland opened the Public Hearing at 8:04 p.m.
Julien Lou, Dylan Marcus, and Bonnie Helms provided comments.
Chair Roland closed the Public Hearing at 8:15 p.m.
C.Deliberation and Vote
The Commission discussed power grids, setbacks, fire response, critical areas,
vulnerable populations, and the next steps in the process.
Vice Chair Stewart moved and Commissioner Hiller seconded to recommend
to City Council the proposed updates to the Battery Energy Storage System
Code as recommended by Staff.
MOTION CARRIES. 3-2. Commissioner Berry and Commissioner Walters
voted no.
The Commission discussed forming a fact finding committee for further
research and added that to next month's agenda.
COMMUNITY DEVELOPMENT REPORT
Manager Teague shared information about the new Home Depot location, unit lot
subdivisions, social media advertising for the Planning Commission, the A Street
Roundabout project, the awarded contract for the Auburn Theater, and shared that the
next meeting would be held on May 5, 2026.
ADJOURNMENT
There being no further business to come before the Planning Commission, the meeting
was adjourned at 8:32 p.m.
APPROVED this 5th day of May, 2026.
_____________________________ _______________________________
JUDI ROLAND, CHAIR Rebecca Wood-Pollock, Deputy City Clerk
Page 6 of 289
AGENDA BILL APPROVAL FORM
Agenda Subject: Meeting Date:
City Clerks OPMA and Parliamentary Procedures
Staff Introduction/Presentation (Wood)
City Clerk to provide an overview of OPMA and Parliamentary Procedures
May 5, 2026
Department: Attachments: Budget Impact:
Community Development PowerPoint Presentation
Administrative Recommendation:
Background for Motion:
Background Summary:
Councilmember: Staff: Jason Krum
Page 7 of 289
Page 8 of 289
AUBURN
VALUES
SERVICE
ENVIRONMENT
ECONOMY
CHARACTER
SUSTAINABILITY
WELLNESS
CELEBRATION
PLANNING COMMISSION
ROLES, LIMITATIONS, AND VOTING
PROCEDURES
Rebecca Wood, Deputy City Clerk
Shawn Campbell, City Clerk Page 10 of 289
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATIONSERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Created under Revised Code of Washington (RCW) 35.63
Purpose: to serve in an advisory capacity to the City Council
Role: to make recommendations to City Council regarding comprehensive planning, zoning and land use regulations, development standards, and other topics of discussion from the Community Development Department
PLANNING COMMISSION AS AN ADVISORY
BODY
Page 11 of 289
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATIONSERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Vote to make a recommendation to Council regarding comprehensive planning, zoning and land use regulations, development standards, and other materials the Community Development Department plans to bring to Council
Suggest amendments to proposed code changes and other materials the Community Development Department plans to bring to Council
Hold Public Hearings
Form Ad Hoc Committees
If the Commission forms an ad hoc Committee, it must contain a number of Commissioners fewer than a quorum of the body
Postpone a vote of the Planning Commission
Council may still vote on an issue even if the Planning Commission has not voted to recommend it to Council
Update the Planning Commission Rules of Procedure
Make any changes regarding meeting dates, rules, etc. not already dictated by City Code
ACTIONS WITHIN THE PLANNING
COMMISSION’S AUTHORITY
Page 12 of 289
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATIONSERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Take any action that falls under the
responsibility of City Council
Example: extend moratoriums, pass code changes, pass
legislation that enacts anything into law
Postpone a vote of the City Council
The City Council does not require a recommendation from
the Planning Commission prior to voting on an issue. While
the Commission’s recommendation is valued, it is not
required for a vote of the City Council
ACTIONS OUTSIDE OF THE PLANNING
COMMISSION’S AUTHORITY
Page 13 of 289
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATIONSERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
1.Staff Presentation
2.Discussion (Clarifying questions to Staff)
3.Public Hearing (if applicable)
4.Deliberation (additional thoughts, support,
concerns, opinions regarding the topic up for
vote)
5.Vote
ORDER OF EVENTS
Page 14 of 289
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATIONSERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Discussion is conducted after (or during) the staff
presentation on a topic, where Commissioners have
the opportunity to ask staff clarifying questions
regarding the content of the presentation and
materials provided in the agenda packet
Deliberation is conducted AFTER a staff
presentation and Public Hearing (if there is one),
where Commissioners can voice their opinions,
support, or concerns regarding the topic up for vote
DISCUSSION VS. DELIBERATION
Page 15 of 289
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATIONSERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
1.A Commissioner must be recognized the Chair and make a
motion
2.Another Commissioner must be recognized by the Chair and
second the motion
3.Chair asks for any further discussion on the topic
1.Amendment(s)
4.The Chair calls for a vote
5.The motion carries if a majority of the Commissioners
present votes in favor
1.Quorum of the body versus majority of members present
6.The motion fails if there is not a majority vote in favor
VOTING
Page 16 of 289
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATIONSERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
If you wish to amend a code as presented by staff:
1.The motion and second must be made to “Recommend to City Council the approvalof the code as presented by staff.”
2.The Chair will ask for any further discussion
3.A Commissioner may move to “Amend the code to make XXX changes”
1.Another Commissioner must second the motion to amend
2.Further discussion commences
3.Vote on the amendment
4.If the vote to amend passes, then the amended motion becomes the main motion
5.If the vote to amend fails, then the main motion stands as it was originally stated
4.The Chair will call for a vote for the main motion
1.If the vote to amend passes, then the new main motion is to “Recommend to City Council the approval of the code as amended.”
2.If the vote to amend fails, then the main motion will stand as “Recommend to City Council the approval of the code as presented by staff.’
5.The motion carries if a majority of the Commissioners present votes in favor
AMENDMENT (EXAMPLE)
Page 17 of 289
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATIONSERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
The motion must be clear for the record
Make a Recommendation: I move to recommend to Council the
adoption of Code Update XYZ as presented by staff
Make an Amendment and Recommendation: I move to recommend to
Council the adoption of Code Update XYZ as amended
Form an Ad Hoc Committee: I move to form an Ad Hoc Committee for
the purpose of gathering additional research and information regarding BESS safety and thermal event prevention with a report back to the Planning Commission at the XX/XX/XXXX Planning Commission meeting
Postpone a vote: I move to postpone the vote on Code Update XYZ
until the XX/XX/XXXX Planning Commission meeting
MAKING A MOTION
Page 18 of 289
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATIONSERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Questions regarding content or scheduling can be directed to
Alexandria Teague or other Community Development
Department staff
Questions regarding parliamentary procedure, OPMA, Rules of
Procedure, or other meeting protocols can be directed to
Rebecca Wood or Chandra Hein
Happy to help script proposed motions if you know about one you intend to make in advance
Help us help you! If you know what you want to do but don’t know proper verbiage or phrasing, just ask!
Informal body = informal motions, but they must still be clear for the record
Staff cannot steer you in one direction or another, but can interpret what you are trying to do and explain how you would go about it
QUESTIONS DURING A MEETING
Page 19 of 289
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATIONSERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
The Planning Commission is an advisory body, created to serve in an advisory capacity to the City Council
A motion must be clearly stated, seconded, and voted on before any further action can take place
Discussion vs. Deliberation
Don’t hesitate to ask questions
KEY TAKEAWAYS
Page 20 of 289
Rebecca Wood, Deputy City Clerk
AUBURN
VALUES
SERVICE
ENVIRONMENT
ECONOMY
CHARACTER
SUSTAINABILITY
WELLNESS
CELEBRATION
QUESTIONS?
Page 21 of 289
AGENDA BILL APPROVAL FORM
Agenda Subject: Meeting Date:
Citywide Design Standards Update and Related Code Update
Staff Introduction/Presentation (Reed)
Staff will present the proposed updates to the Citywide Design Standards
and amended code to Planning Commission for a recommendation to City
Council.
May 5, 2026
Department: Attachments: Budget Impact:
Community Development Staff Report , Exhibit 1
PowerPoint Presentation, Exhibit
2 Citywide Design Standards,
Exhibit 3 ACC18.31.200 Text
Amendment, Exhibit 4 ACC
18.23.040 Text Amendment,
Exhibit 5 ACC 18.07.030 Text
Amendment
Administrative Recommendation:
Planning Commission to deliberate and recommend that City Council approve the updated Citywide
Design Standards and associated amendment to Title 18, including Sections 18.31.200, 18.07.030
and 18.23.040 of the Auburn City Code.
Background for Motion:
Background Summary:
See attached Staff Report
Councilmember: Staff: Jason Krum
Page 22 of 289
PLANNING COMMISSION STAFF REPORT
AGENDA SUBJECT/TITLE:
Citywide Design Standards Update and Related Code Update
CITY FILE NO(s).:
City File No. ZOA26-0002
APPLICANT/AGENT/OWNERS:
City of Auburn
REQUEST:
Planning Commission to deliberate, hold a public hearing, and recommend that City Council approve the
updated Citywide Design Standards and associated Code updates to comply with HB 1293 state
requirements.
LOCATION:
Citywide
NOTIFICATION:
A Notice of Public Hearing (NOH) and SEP26-0003 Determination of Non-Significance (DNS) was issued
on March 6, 2026.
HEARING DATE:
May 5, 2026
SEPA STATUS:
A SEPA Environmental Checklist for a Non-Project Action with a threshold determination of non-
significance (DNS) was issued on March 6, 2026, with a public comment period ending on March 20,
2026, and an appeal period ending April 3, 2026.
STAFF:
Dinah Reed, Senior Planner, Dept. of Community Development
STAFF RECOMMENDATION:
Planning Commission to deliberate and recommend that City Council approve the updated Citywide
Design Standards and associated amendment to Title 18, including Sections 18.31.200, 18.07.030 and
18.23.040 of the Auburn City Code.
Page 23 of 289
Staff Member: Reed Date: March 19, 2026
Page 2 of 5
SUMMARY OF CODE CHANGES
Section ACC 18.31.200 Architectural and site design review standards and regulations
The purpose of the revisions in this section is as follows:
1) ACC 18.31.200(B)(1) clarifies for the types of new development that are applicable to the
design standards
2) ACC 18.31.200(B)(1)(a), (b), (c), (d) clarifies that apartment buildings, mixed-use
residential development, retirement apartments, congregate living facilities and senior
housing are no longer subject to conditional use permits, and non-residential development,
except for development within the industrial zones.
3) ACC 18.31.200(B)(3) removes Auburn Junction as a design review document. Auburn
Junction is a specific area defined in the downtown area. The Downtown Urban Center
Design Standards have largely superseded the Auburn Junction Design Standards, and they
are no longer needed.
4) ACC 18.31.200(C) removes standard (5) and (6) related to the threshold of a site and
exterior alteration. The specific threshold or levels of site and exterior alteration that would
trigger design review are now contained in the Citywide Design Standards.
5) ACC 18.31.200(F) pre-application meetings are no longer mandatory (required) but are
recommended. This update is related to HB 5290 in which cities should no longer make pre-
application meetings mandatory.
6) ACC 18.31.200(I) updates the requirements for design review departures (formerly called
adjustments). The Citywide Design Standards now contain specific departures for specific
design standards. The proposed standard-specific departures will allow for flexibility for
each development, while ensuring that the overall design of the development meets the
purpose and intent of the design standards. Applicants are still required to make findings
(explain) why the departure is necessary. This section also removes the requirement for
public notice for departures. Public notice is only required when a design review application
triggers a state environmental policy act review or exceeds 40 units. Therefore, it should
not be triggered for a design review departure.
7) ACC 18.31.200(J) updates the approval criteria for design review applications. The specific
standards listed in this section are no longer necessary. The proposed development must
be consistent with the standards contained in the Citywide Design Standards for it to be
approved.
Section ACC 18.07.030 Development standards (Residential Zones)
The proposed revision to ACC 18.07.030 is to reduce the front setback in the R-4, Residential High
and R-NM, Residential Neighborhood Mixed-Use zones to zero to allow for the “Storefront” option in
the Citywide Design Standards. This update allows for a storefront for a mixed-use or non-
residential use in the R-4 and R-NM zones to abut public sidewalks and help to create vibrant and
active pedestrian-oriented shopping and dining areas within Auburn. A zero front lot line is permitted
only where structures meet sight distance requirements in accordance with city engineering design
and construction standards.
Page 24 of 289
Staff Member: Reed Date: March 19, 2026
Page 3 of 5
Section ACC 18.23.040 Development standards (Commercial & Industrial Zones)
These revisions reduce the front setback in the C-1, Light Commercial, C-2, Heavy Commercial, and
M-1, Light Industrial zones to zero to allow for the “Storefront” option in the Citywide Design
Standards.
FINDINGS OF FACT:
Background Summary:
1. House Bill (HB) 1293, an Act related to streamlining development regulations for design review, was
passed by the Legislature in the 2023 Regular Session. HB 1293 requires counties and cities planning
under Revised Code of Washington (RCW) 36.70A.040 to have clear and objective development
regulations governing the exterior design of new development.
2. The updates to the existing Citywide Design Standards provide clear objectives for the planning and
design of development projects. The standards will preserve and protect the public health, safety, and
welfare of the citizens of Auburn. They will ensure that new multifamily, mixed -use, and commercial
development enhances the public’s experience of Auburn and promote increased walkability,
bicycling, and transit use in Auburn.
3. The updated design standards for redevelopment contain three different thresholds of construction
(building additions, remodels, and site improvements) that have been established based on the
percentage of the site improvement that affects the exterior appearance of the building/site and/or
cumulative increase in gross floor area.
4. Design “Departures” are provided for specific standards to allow for alternative design options
Page 25 of 289
Staff Member: Reed Date: March 19, 2026
Page 4 of 5
provided the reviewing authority determines the design meets the purpose of the standards and other
applicable criteria.
5. Block Frontage Standards are provided to achieve street level aesthetics and enhance pedestrian
environments by emphasizing ground-level designs for commercial, mixed-use and multifamily
developments. Key intersections along the future I line RapidRide bus stops on Auburn Way North are
designated to use Block Frontage Standards for future development proposals.
6. In accordance with ACC 14.03.060 Legislative nonproject decisions made by the city council under its
authority to establish policies and regulations are not classified as a “type” of project permit decision.
Legislative nonproject decisions include, but are not limited to, amendments to the text and map of
the comprehensive plan or development regulations.
7. Per ACC 18.68.030(B) a “Zoning Text Amendment” is an application to change the text of ACC Title
18. This type of application or initiation shall be processed as a legislative nonproject decision,
consistent with ACC 14.03.060. Public notice shall be provided consistently with ACC Title 14.
8. RCW 42.21C.135 provides authority of local governmental units to adopt rules, guidelines and model
ordinances by reference.
9. The associated text amendment to the updated design standards includes changes to ACC
18.31.200, ACC 18.07.030, and ACC 18.23.040.
10. The design standards update and text amendment were introduced and discussed with the Planning
Commission previously at the February 3, 2026, meeting and the March 3, 2026, meeting. Staff
provided memorandums and presentations.
11. A public Open House was held on February 4, 2026, at the Auburn Resource Center and was well
attended.
12. An email from Auburn Communications was sent on February 7, 2026, to a list of architects in the
region inviting them to review the new design standards located on the City’s public notices website.
Procedural Steps:
1. The proposed updates to the existing Citywide Design Standards and text amendment (zoning code
update) have been discussed with the Planning Commission previously at regular meetings on
February 3, 2026, and March 3, 2026.
2. Pursuant to Revised Code of Washington (RCW) 36.70A, the text amendment was transmitted to the
Washington State Department of Commerce on December 31, 2025. The 60-day notice period ended
on March 1, 2026.
3. A Determination of Non-Significance (DNS) (SEP26-0003) and Notice of Public Hearing (NOH) was
issued on March 6, 2026. Pursuant to Chapter 18.68 ACC, the following methods of noticing for the
Planning Commission public hearing were conducted:
Page 26 of 289
Staff Member: Reed Date: March 19, 2026
Page 5 of 5
a. The NOH was published in the Seattle Times on March 6, 2026.
b. The NOH was posted in three public locations (City Hall, City Annex, and the City’s Public
Land Use Notice webpage).
c. The NOH was mailed to property owners in the Citywide “designated” areas on Auburn Way N
(“designated” per the Citywide Design Standards) on March 19, 2026.
d. The SEPA checklist and notice (City File No. SEP26-0003) was uploaded to the Washington
State Department of Ecology SEPA registry on March 6, 2026.
e. No public comments were received during the SEPA comment period or the open house.
EXHIBITS:
1. Citywide Design Standards and Code Update Presentation
2. Citywide Design Standards
3. ACC 18.31.200 Text Amendment
4. ACC 18.23.040 Text Amendment
5. ACC 18.07.030 Text Amendment
Page 27 of 289
AUBURN
VALUES
S E R V I C E
ENVIRONMENT
E C O N O M Y
C H A R A C T E R
SUSTAINABILITY
W E L L N E S S
C E L E B R AT I O N
CITYWIDE DESIGN STANDARDS AND
RELATED CODE UPDATE
PLANNING COMMISSION
HEARING
PRESENTED BY
DINAH REED, SENIOR PLANNER
MAY 5 , 2026
Department of Community Development
Planning ⚫ Building ⚫ Development Engineering ⚫ Permit Center
Economic Development ⚫ Code Enforcement
Exhibit 1
Page 28 of 289
CITYWIDE DESIGN STANDARDS
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
➢House Bill (HB) 1293 an Act
relating to streamlining
development regulations for
design review was passed.
➢At the regular PC Meetings on
Feb 3, 2026 and Mar 3, 2026
staff introduced the revised
Citywide Design Standards and
Code Update.ExistingPage 29 of 289
CITYWIDE DESIGN STANDARDS UPDATE
PROCEDURAL STEPS
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
The text amendment was transmitted to WA State Dept.
of Commerce on Dec 31, 2025, per (RCW) 36.70A
Notice of Public Hearing and SEP26 -0003 DNS was
issued on Mar 6, 2026, and the NOH was re-issued on
April 24, 2026 , per Chapter 18.68 ACC.
No comments were received from WA Dept. of
Commerce on text amendments .
Page 30 of 289
CITYWIDE DESIGN STANDARDS UPDATE
BACKGROUND
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
➢To update existing City of Auburn “Citywide”
design standards.
➢To provide clear and objective development
regulations for the design review process.
➢The regulations apply to the exterior design of
new development.
Page 31 of 289
CITYWIDE DESIGN STANDARDS UPDATE
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
➢Applies to new development that is:
➢Non -residential
➢Mixed -use
➢Apartment buildings (with 7 or more units)
➢Do not apply to:
➢DUC zone
➢Middle housing
➢Non Mixed -use development in the M -1 and M -2
Industrial zones.
Page 32 of 289
CITYWIDE DESIGN STANDARDS UPDATE
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
➢Designated intersections will incorporate
“Mixed Block Frontage Standards” for new
development.
➢Enhance pedestrian environment
➢Emphasize ground level design
➢Promote street level aesthetic and pedestrian
security
Page 33 of 289
Map of
RapidRide
I Line
Bus Stop
Intersections
Along
Auburn Way
North
49th St NE
42nd St NE
37 th St NE
28th St NE
22nd St NE
15th St NE
Page 34 of 289
CITYWIDE DESIGN STANDARDS UPDATE
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
Mixed Block
Frontage
Standards include
development for
Storefronts
Page 35 of 289
EXAMPLES FOR LANDSCAPED BLOCK -FRONTAGE
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
Page 36 of 289
TRANSPARENCY STANDARDS
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
➢Block frontage designations contain distinct minimum
façade transparency standards.
Page 37 of 289
OTHER PROMINENT DESIGN STANDARDS
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
Page 38 of 289
OTHER PROMINENT DESIGN STANDARDS
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
Building
Massing and
Articulation
Page 39 of 289
PARKING
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
Page 40 of 289
CODE UPDATE – ACC 18.31.200(B)(1)
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
Page 41 of 289
CODE UPDATE – ACC 18.31.200(B)(1)(A)(B)
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
Page 42 of 289
CODE UPDATE – ACC 18.31.200(B)(1)(C)(D)
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
Page 43 of 289
CODE UPDATE – ACC 18.31.200(B)(3)
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
Page 44 of 289
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
CODE UPDATE – ACC 18.31.200(C)
Page 45 of 289
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
CODE UPDATE – ACC 18.31.200(F)
Page 46 of 289
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
CODE UPDATE – ACC 18.31.200(I)
Page 47 of 289
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
CODE UPDATE – ACC 18.31.200(J)
Page 48 of 289
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
CODE UPDATE – ACC 18.31.040
COMMERCIAL & INDUSTRIAL ZONES
Page 49 of 289
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
CODE UPDATE – ACC 18.31.030
RESIDENTIAL ZONES
Page 50 of 289
SERVICE ⚫ ENVIRONMENT ⚫ ECONOMY ⚫ CHARACTER ⚫ SUSTAINABILITY ⚫ WELLNESS ⚫ CELEBRATION
REQUEST
Planning Commission to deliberate and recommend
that City Council approve the updated Citywide Design
Standards and associated amendments to Title 18 to
comply with HB 1293 state requirements.
Page 51 of 289
AUBURN
VALUES
S E R V I C E
ENVIRONMENT
E C O N O M Y
C H A R A C T E R
SUSTAINABILITY
W E L L N E S S
C E L E B R AT I O N
Department of Community Development
Planning ⚫ Building ⚫ Development Engineering ⚫ Permit Center
Economic Development ⚫ Code Enforcement
Thank you,
Questions?
Page 52 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 1
Auburn Citywide Design-Standards_2026-02-24
City of Auburn
CITYWIDE DESIGN STANDARDS
Draft, February 24, 2026
Contents
Chapter 1: Introduction ............................................................................................................ 3
1.1 Purpose. ............................................................................................................................................................... 3
1.2 Applicability. ........................................................................................................................................................ 3
1.3 How the provisions of this chapter are applied. ........................................................................................ 4
1.4 Definitions ........................................................................................................................................................... 4
Chapter 2 – Block-Frontage Standards ................................................................................... 6
2.1 Purpose. ............................................................................................................................................................... 6
2.2 Block-frontage designation maps. .................................................................................................................. 6
2.3 About the transparency standards. ............................................................................................................... 8
2.4 Storefront standards. ...................................................................................................................................... 10
2.5 Landscaped block-frontage standards. ........................................................................................................ 12
2.6 Mixed block-frontage standards. .................................................................................................................. 14
2.7 Other/Undesignated block-frontage standards. ....................................................................................... 15
2.8 Ground-floor residential frontage standards. ........................................................................................... 16
2.9 Through-block connection frontage standards. ....................................................................................... 20
2.10 Corner site clarifications. ............................................................................................................................ 20
2.11 Mixed-use street corner standards. .......................................................................................................... 21
Chapter 3 - Site Planning ........................................................................................................ 22
3.1 Useable residential recreational space. ...................................................................................................... 22
3.2 Public Plazas and pedestrian-oriented space. ............................................................................................ 26
3.3 Parking lots, garages, and drive access design. .......................................................................................... 28
Page 53 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 2
Auburn Citywide Design-Standards_2026-02-24
3.4 Service areas and mechanical equipment. .................................................................................................. 34
Chapter 4 - Building Design .................................................................................................... 36
4.1 Building massing and articulation. ................................................................................................................ 36
4.2 Building details. ................................................................................................................................................. 40
4.3 Building materials. ............................................................................................................................................ 45
4.4 Blank wall treatment. ...................................................................................................................................... 50
4.5 Rooftop services area and mechanical equipment. .................................................................................. 53
Chapter 5 – Guidelines For All Developments ..................................................................... 54
5.1 Climate Friendly Design. ................................................................................................................................ 54
5.2 Defensive Space (CPTED). ............................................................................................................................ 54
Page 54 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 3
Auburn Citywide Design-Standards_2026-02-24
Chapter 1: Introduction
1.1 Purpose.
These design standards are authorized by the City Council as a major implementation tool of the
Auburn Comprehensive Plan. Overall, these standards intend to:
• Provide clear objectives for the planning and design of development projects.
• Preserve and protect the public health, safety, and welfare of the citizens of Auburn.
• Ensure that new multifamily, mixed-use, and commercial development enhances the public’s
experience of Auburn.
• Promote increased walking, bicycling, and transit use in Auburn’s Growth Centers.
1.2 Applicability.
(1) New development. The provisions of this chapter apply to all non-residential, mixed-use, and
apartment building (containing seven or more units on a single lot) developments within the City,
except:
(a) Developments within Downtown Urban Center, which are subject to their own design
standards.
(b) Middle housing developments that meet the standards of ACC 18.25.040 and 18.04.340(B) shall
follow the middle housing design standards of ACC 18.25.070.
(c) Non Mixed-Use developments within the M-1 and M-2 zones.
(2) Building additions, remodels, and site improvements. Three different thresholds have been
established to determine how the standards herein are applied to such projects.
(a) Level I improvements include all exterior remodels, building additions, and/or site improvements
that affect the exterior appearance of the building/site and/or cumulatively increase the gross
floor area on a site by less than 50 percent within three years of the date of permit issuance.
The requirement for such improvements is only that the proposed improvements meet
applicable standards herein, and do not lead to further nonconformance with the
aforementioned standards.
For example, if a property owner decides to replace a building façade’s siding, then the siding
shall meet the applicable exterior building material standards, but elements such as building
articulation would not be required.
(b) Level II improvements include all improvements that cumulatively increase the gross floor area
on a site by 50 percent to 100 percent within three years of the date of permit issuance. All
standards that do not involve repositioning the building or reconfiguring site development shall
apply to Level II improvements. In the case where the site includes multiple buildings and one or
more of those buildings aren’t being enlarged, such buildings are not required to be improved or
relocated.
(c) Level III improvements include all improvements that cumulatively increase the gross floor area
on a site by more than 100 percent within three years of the date of permit issuance. Such
developments shall conform to all applicable standards, except in a case where there are
multiple buildings on one site, and one or more buildings are not being enlarged. In that
Page 55 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 4
Auburn Citywide Design-Standards_2026-02-24
scenario, improvements to the building or buildings not being enlarged are not required, but
conformance with all other standards apply.
(3) Public buildings. Public buildings are exempt from the design standards herein, provided design
treatments are integrated to meet the following objectives:
(a) Enliven the pedestrian environment along the adjacent sidewalks.
(b) Incorporate a prominent and inviting entry visible from the street.
(c) Building design and materials should evoke a sense of permanence.
(d) Site and building design stands out from the surrounding context as a distinct landmark and
provides visual interest from all observable scales.
1.3 How the provisions of this chapter are applied.
Most sections within this chapter herein include the following elements:
(1) Purpose statements, which are overarching objectives.
(2) Standards use words such as “must” and “is/are required,” signifying required actions.
(3) Guidelines use words such as “should” or “is/are recommended,” signifying voluntary measures.
(4) Design “Departures” are provided for specific standards in this chapter. They allow alternative
designs provided the reviewing authority determines the design meets the purpose of the standards
and other applicable criteria. See ACC 18.31.200(I) for related procedures associated with
departures.
(5) Relationship to other codes and documents. Where provisions of this chapter conflict with
provisions in any other section of the Auburn City Code (ACC), this chapter prevails unless
otherwise noted.
(6) This chapter contains some specific standards that are easily quantifiable, while others provide a
level of discretion in how they are complied with. In the latter case, the applicant must demonstrate
to the director, in writing, how the project meets the purpose of the standard or standards.
1.4 Definitions
Definitions in Chapter 10.04, ACC apply to these standards. Below are supplemental definitions that
apply specifically to these design standards:
(1) Articulation - A method of styling the joints and transitions in the formal elements of architectural
design for the purpose of creating visual interest. Includes treatments to building joints and
transitions such as indents, projections, material changes, façade treatments.
(2) Belt Course - A molding or projecting course running horizontally along the face of a building.
(3) Canopy - A cover over a sidewalk providing protection from the rain or shade from the sun, which
is constructed of durable, permanent materials.
(4) Cornice - A horizontal decorative or ornamental molding located at the top of a building facade.
(5) Director - means the director of the Auburn Planning and Development Department.
(6) Façade – Street facing building elevations.
(7) Multifamily – Apartment buildings featuring seven or more dwelling units on a single lot.
Page 56 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 5
Auburn Citywide Design-Standards_2026-02-24
(8) Parking, structured - Parking contained within an enclosed building either part of or designed to
appear like it is part of the larger building complex, or a freestanding structure devoted exclusively
to above-grade parking.
(9) Plinth - A block used as the base of a column or other upright support.
(10) Public art - Any form of painting, mural, mosaic, sculpture, or other work of art, so long as it can be
appraised as a work of art and its value as such documented, displayed on the exterior of a building,
at or near the pedestrian entrance, or on a public plaza, and visible to users of the public right-of-
way at all times.
(11) Public plaza - An open space that is visible and accessible to the public at all times predominantly
open to the sky, and for use principally by people, as opposed to merely a setting for the building.
(12) Storefront – A building featuring a ground level abutting the sidewalk and complying with the
provisions of Section 2.4.
(13) Street level retail - Uses providing goods and services, including food and drink, adjacent to, visible
from, and directly accessible from the public sidewalk.
Page 57 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 6
Auburn Citywide Design-Standards_2026-02-24
Chapter 2 – Block-Frontage Standards
2.1 Purpose.
(1) To achieve the envisioned street level aesthetic and enhance the public’s experience of Auburn.
(2) To enhance pedestrian environments by emphasizing activated ground-level block-frontage designs
for commercial, mixed-use, and multifamily developments.
(3) To minimize potential negative impacts of driveways and off-street parking facilities on the
streetscape.
(4) To promote good visibility between buildings and the street for security for pedestrians and to
create a more welcoming and interesting streetscape.
2.2 Block-frontage designation maps.
(1) The block-frontage designations established by this chapter are maintained under the direction of
the director. All notations, references, and other information shown have the same force and effect
as if fully described in this title.
Page 58 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 7
Auburn Citywide Design-Standards_2026-02-24
Designated block frontages
Page 59 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 8
Auburn Citywide Design-Standards_2026-02-24
2.3 About the transparency standards.
All block-frontage designations contain distinct minimum façade transparency standards. The purposes
of these standards are to maintain “eyes on the street” for safety and create welcoming pedestrian
environments. The table below includes details in how they are measured.
Transparency standards
Transparency area
Storefront
Ground floor non-residential
on Landscaped block frontage
Residential buildings and
residential portions of
mixed-use buildings
The transparency area is on the
ground floor between 30” and 10’
above sidewalk grade
The transparency area is between
30” and 8’ above grade
All vertical surfaces of the façade are
used in the calculations
Other Transparency Provisions
Windows must be transparent
Ground-level window area for storefronts
and other non-residential uses that is
covered, frosted, or perforated in any
manner that obscures visibility into the
building must not count as transparent
window area. Also, mirrored glass and
highly-reflective or darkly-tined windows
must not be counted as transparent
windows.
Covered windows Perforated sign
Page 60 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 9
Auburn Citywide Design-Standards_2026-02-24
Transparency standards
Display windows & parking garages
Display windows may be used for up to
25% of non-residential transparency
requirements provided they are at least
30” deep to allow changeable displays and
the interior wall is non-structural so it can
be removed if the windows are not used
for display. Tack-on display cases as
shown in the far right example do not
qualify as transparent window area.
For parking garages (where allowed by
block frontage standards), the left image
illustrates how such a structure can meet
(and not meet) the applicable
transparency standards.
Integrated display windows Tack-on display cases
Parking garage with windows Parking garage without windows
Page 61 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 10
Auburn Citywide Design-Standards_2026-02-24
2.4 Storefront standards.
(1) Purpose. Storefronts abutting public sidewalks help to create vibrant and active pedestrian-
oriented shopping and dining areas within Auburn. The high visibility of such facades warrants
minimum design standards for transparency, weather protection, interior storefront depth and
height, and entries to better ensure the long term success of these buildings and their districts or
neighborhoods.
Storefront vision and key standards.
(2) Applicability.
Storefront standards apply to situations for Mixed and Undesignated block frontages where
developments choose to integrate storefronts on portions or all of their applicable block frontages.
(3) Standards. Applicable development must comply with the standards in Table 2.4 below.
Table 2.4
Storefront standards.
The symbol refers to DEPARTURE opportunities opportunities set forth in Section 1.3 with supplemental criteria in
subsection (4) below.
Element Storefront Standards
Ground-level
Land use See ACC 18.07.020 and 18.23.030, except:
Residential uses are prohibited except:
• Live/work units featuring ground level space that complies with minimum floor
to floor height and non-residential space depth herein.
• Lobbies and accessory-uses associated with multifamily residential uses are
allowed provided they are limited to 60% of block-frontages.
Page 62 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 11
Auburn Citywide Design-Standards_2026-02-24
Table 2.4
Storefront standards.
The symbol refers to DEPARTURE opportunities opportunities set forth in Section 1.3 with supplemental criteria in
subsection (4) below.
Element Storefront Standards
Floor to floor height for new
buildings
(applies to the minimum non-
residential space depth)
12’ minimum.
Non-residential space depth 20’ minimum.
Building placement Standards in this table apply when buildings are placed within 10’ of the required
sidewalk.
Building entrances Primary building entrances must face the street or a pedestrian-oriented space that
is adjacent to the street. For corner sites, the entry may face the corner, or one or
both streets.
Façade transparency
(see Section 2.3)
At least 50% of the transparency area.
Weather protection Weather protection is required along at least 50% of the storefront façade, and it
must be a minimum of 5’ deep and have 8’ to 12’ of vertical clearance.
Note: Weather protection that encroaches over the public right-of-way will
require a permit meeting the standards of ACC 12.60 and ACC 12.60.050.
The director may require reduced width weather protection where necessary to
avoid interfering with street trees, street lights, street signs, or extending beyond
the edge of the sidewalk.
Parking location Not applicable (sites are subject to applicable designated block frontage parking
location provisions).
Sidewalk width Sidewalks abutting storefronts must be at least 10’ wide. Where such sidewalks
extend beyond right-of-way limits, a public access easement is required to
accommodate the full sidewalk width. Upper floors may cantilever over the
sidewalk to the right-of-way edge or 4’, whichever is less.
(4) DEPARTURE criteria. Departures from the standards in Table 2.4 that feature the symbol will
be considered provided the alternative proposal meets the purpose of the standards and the
following criteria:
(a) Non-residential space depth. Reduced depths on up to 25 percent of the applicable block-
frontage will be considered where the applicant can successfully demonstrate the proposed
alternative design and configuration of the space is viable for a variety of permitted non-
residential uses.
(b) Facade transparency. Departures for facade transparency in the transparency area may be
reduced to a minimum of 35 percent for block-frontages if the façade design between ground-
level windows provides visual interest to the pedestrian and mitigates the impacts of blank walls.
(c) Weather-protection. The reduced extent (to no less than 35 percent) or width (to no less than
four-feet in width) will be considered provided the designs are proportional to architectural
Page 63 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 12
Auburn Citywide Design-Standards_2026-02-24
features of the building and building design trade-offs (elements that clearly go beyond minimum
building design standards in this chapter) meet the purpose of the standards.
2.5 Landscaped block-frontage standards.
(1) Purpose. To provide standards for an optional block frontage design along Mixed-designated
streets that incorporates modest landscaped setbacks, clear pedestrian connections between the
building and the sidewalk, and minimized surface parking lots along the frontages.
(2) Applicability. Standards herein apply as an option for development on Mixed designated block
frontages and a requirement for new multifamily development. Note that developments featuring
ground-level dwelling units along block frontages, such frontages are also subject to the provisions of
Section 2.8, Ground-floor residential frontage standards.
(3) Standards. Applicable developments are subject to the Landscaped block frontage standards set
forth in Table 2.5.
Landscaped frontage vision and key standards.
Table 2.5
Landscaped block-frontage standards.
The symbol refers to DEPARTURE opportunities opportunities set forth in Section 1.3 with supplemental criteria in
subsection (4) below.
Element Standards
Ground-level
Land use As set forth in ACC 18.07.020 and 18.23.030.
Building placement 10’ minimum setback or as required in the applicable zone, whichever is greater.
Block frontages with ground floor dwelling units must comply with Section 2.8 .
Page 64 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 13
Auburn Citywide Design-Standards_2026-02-24
Table 2.5
Landscaped block-frontage standards.
The symbol refers to DEPARTURE opportunities opportunities set forth in Section 1.3 with supplemental criteria in
subsection (4) below.
Element Standards
Building entrances Building entries must face the street or a pedestrian-oriented space that is
adjacent to the street. For corner sites, the entry may face the corner, or one or
both streets.
Façade transparency
(see Section 2.3)
For buildings with ground-level non-residential uses, at least 35% of the
transparency area.
For buildings with ground-level residential uses, at least 15% of the entire facade.
Weather protection Weather protection at least 3’ deep must be provided over individual residential
and commercial tenant entries and at least 5’ deep for shared residential and
professional office entries.
Parking location Surface level parking and access features must be located to the side or rear of
buildings. For sites with multiple buildings, no more than 50 percent of arterial
street block frontages may be occupied by parking and vehicular access
areas.
Driveways shall meet the standards of the Engineering Design and Construction
Standards.
Landscaping All areas between the sidewalk and the building must be landscaped, except for
walkways, porches, decks, and other areas meeting the definition of pedestrian -
oriented space. The required landscaping must meet the provisions of ACC
18.50.040(C) and 18.50.070.
For parking lot perimeter landscaping, see Section 3.3.
(4) DEPARTURE criteria. Departures to the Landscaped block-frontage standards in Table 2.5 that
feature the symbol will be considered provided the alternative proposal meets the purpose of the
standards and the following criteria:
(a) Building placement: Reduced setbacks will be considered for non-residential ground level
frontages where the façade effectively integrates a blend of storefront and landscaped frontage
elements. For example, window transparency levels should increase towards Storefront
standards at a proportional rate as the setback gets smaller.
(b) Façade transparency: Façade transparency in the transparency area may be reduced from the
minimum standards by 50 percent if the façade design between ground-level windows provides
visual interest to the pedestrian and mitigates the impacts of blank-walls.
(c) Parking location. Alternative designs may be considered with some parking located between the
street and a building or buildings where such design helps to better take advantage of the site’s
context. Design treatments must be included to mitigate the impact of parking areas along the
street (in terms of visual impacts and pedestrian access to the buildings from the street).
Page 65 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 14
Auburn Citywide Design-Standards_2026-02-24
2.6 Mixed block-frontage standards.
(1) Purpose. To provide for flexibility in the design of applicable block frontages while ensuring that
block frontages create a pedestrian-friendly environment.
(2) Applicability. Standards herein apply to all sites containing designated Mixed block frontages per
the maps in Section 2.2. Note that for developments featuring ground level dwelling units adjacent
to the street, the design of such block frontages are subject to Section 2.8.
(3) Standards. Applicable development may choose between Storefront standards set forth in Table
2.4 or Landscaped block frontage standards as set forth in Table 2.5 or some combination of the
two, with modifications noted in the scenarios below:
(a) A site with a proposed storefront building (or segment of a building), the building(s) will be
subject to the Storefront standards set forth in Table 2.4, except that for parking location
standards, sites will be subject to the provisions in the Landscaped block frontage standards in
Table 2.5.
(b) For a site that features a building or buildings with a mix of proposed Storefront and Landscaped
block frontage designs, the storefront building segments will be subject to the Storefront
standards set forth in Table 2.4, whereas everything else will be subject to the Landscaped block
frontage standards as set forth in Table 2.5.
(4) Blending frontages. Buildings may also employ designs that are a hybrid of storefront and
landscaped block frontage forms, where they feature a small landscaped setback (less than what is
required under the Landscaped block frontage standards), provided the window transparency levels
increase towards Storefront standards at a proportional rate as the setback gets smaller. Weather
protection isn’t required in frontage areas where there’s more than 16 inches of landscaping
adjacent to the façade (measured perpendicular to the façade). All other standards for Storefront
standards in Table 2.4 apply.
Page 66 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 15
Auburn Citywide Design-Standards_2026-02-24
2.7 Other/Undesignated block-frontage standards.
(1) Purpose. To provide for flexibility in the design of block frontages in areas where such flexibility is
warranted.
(2) Applicability. Standards herein apply to all commercial development on sites that are not
otherwise designated as a Mixed block frontage.
(3) Standards. Applicable developments are subject to the Other/Undesignated block frontage
standards in Table 2.7, except where developments integrate storefront buildings abutting the
sidewalk edge. Such storefront buildings are subject to the Storefront standards in Table 2.4.
Table 2.7
Other/Undesignated block-frontage standards.
The symbol refers to DEPARTURE opportunities opportunities set forth in Section 2.7 with supplemental criteria in
subsection (4) below.
Element Standards
Building placement Where allowed in the applicable zone, buildings may be placed within 10’ of the
required sidewalk, provided they meet Storefront standards in Table 2.4.
Buildings and portions thereof with ground floor dwelling units are subject to the
standards in Section 2.8.
Otherwise, buildings shall meet the applicable standards set forth in ACC
18.07.030 and 18.23.040.
Building entrances Building entrances facing the street are encouraged. At a minimum, at least one
building entry visible and directly accessible from the street is required.
Where buildings are setback from the property line, pedestrian connections from
the sidewalk are required.
Façade transparency
(see Section 2.3)
Storefronts adjacent to the back of the sidewalk are subject to Storefront façade
transparency standards in Table 2.4.
Other buildings designed with non-residential uses on the ground floor within 20
feet of sidewalk, at least 30% of the ground floor between 30” and 8’ above
grade.
For residential buildings, at least 15% of the entire façade.
Weather protection Weather protection at least 3’ deep must be provided over individual residential
and commercial tenant entries and at least 5’ deep for shared residential and
professional office entries.
Parking location There are no parking lot location restrictions, except for landscaped buffer
requirements set forth in ACC 18.50.040.C.4 and 18.50.040(B).
Driveways shall meet the standards of the Engineering Design and Construction
Standards.
Landscaping Sites are subject to the landscaping requirements of Section 3.3 and Chapter
18.50, ACC.
Page 67 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 16
Auburn Citywide Design-Standards_2026-02-24
(4) DEPARTURE criteria. Departures to the Other/Undesignated block-frontage standards in Table
20.26.170.3 that feature the symbol will be considered provided the alternative proposal meets
the purpose of the standards and the following criteria:
(a) Façade transparency: Façade transparency in the transparency area may be reduced from the
minimum standards by 50 percent if the façade design between ground-level windows provides
visual interest to the pedestrian and mitigates the impacts of blank-walls.
2.8 Ground-floor residential frontage standards.
(1) Purpose. The purpose of these standards is to:
(a) Enhance the privacy and security of residents living on the ground floor.
(b) Provide an effective visual and physical transition between the public realm and the private
realm.
(c) Enhance the relationship between the building and the street through high-quality landscape and
architectural design.
(2) Applicability. All developments with ground-floor residential uses adjacent to public streets, trails,
through-block connections or other internal pedestrian connections, parks, publicly accessible
common areas, and internal common space (hereafter collectively referred to as “public and semi-
public realm”) shall comply with the frontage standards herein.
(3) Standards. Design treatments must be integrated to enhance the character of the public and semi-
public realm while respecting the privacy of adjacent residential units. Design criteria applicable to
ground-floor residential frontages are as follows:
(a) Unit setback and elevation. Provide privacy for people living in the adjacent dwelling units and
ensure the applicable public and semi-public realm environment is comfortable through all of the
following measures:
(i) Provide a five-foot minimum setback from applicable public and semi-public realm elements.
The setback shall be measured from the edge of the applicable public (e.g., sidewalk) and
semi-public realm elements (e.g., walkway, pedestrian-oriented space, common open space).
When adjacent to an applicable public and semi-public realm element with no adjacent
walkway, the setback shall be measured from the outside edge (facing away from dwelling
unit) of a physical threshold feature (e.g., low fence or hedge) that separates semi-private
outdoor space with the applicable public and semi-public realm element as determined by the
Director.
DEPARTURES will be considered provided the design enhances the character of the
streetscape and respects the privacy of adjacent ground-floor residents.
(ii) Where the façade is within ten feet of a sidewalk (when allowed by the applicable zone) or
five feet from all other applicable public and semi-public realm elements, the ground floor
must be elevated a minimum average of 30-inches to improve privacy of such residential uses
and enhance their relationship to the street.
Page 68 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 17
Auburn Citywide Design-Standards_2026-02-24
Minimum setback between a ground floor residence and
applicable public and semi-public realm element
In the left example, the 5-foot setback area is used for raised planters next to a sidewalk. In the right example, the
minimum 5-foot setback area is used for a wall and landscaped bed next to a public space.
(c) Units with direct physical access and less than ten feet setback to the sidewalk or other
applicable public and semi-public realm elements must enhance the privacy of residents and
provide an effective transition between the public and private realm by integrating all of the
following measures:
(i) Provide a physical “threshold” feature, such as a hedge, retaining wall, rockery, stair, gate,
railing, or a combination of such elements on private property, not to exceed 42 inches in
height, that defines and bridges the boundary between the applicable public and semi-public
realm element and the private entry, porch, yard, or patio. Thresholds may screen, but not
completely block, eye-level views to and from the applicable public and semi-public realm
element.
(ii) Provide an outdoor space at least four feet deep and six feet wide (24 square feet minimum
area) in the front setback, such as a porch, patio, deck, or stoop. Where feasible, this space
shall be at the same level as the interior of the unit.
(iii) Provide a covered area, porch or protected entry space, or other architectural weather
protection at least three feet deep that provides cover for a person entering the unit and a
transitional space between outside and inside the dwelling.
(iv) Landscaping planters shall be integrated into transitional areas between the dwelling unit and
the adjacent public and semi-public realm element.
(v) Overhead building projections may cantilever over the outdoor space by up to 50 percent of
the minimum ground level setback.
DEPARTURES may be proposed for the design criteria in subsection (c) above provided the
design enhances the privacy of adjacent units and provides an effective and attractive transition
between the public and private realm.
Page 69 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 18
Auburn Citywide Design-Standards_2026-02-24
Guidelines and examples of ground-level residential frontages
The above images show ground-level residential frontages with setbacks of approximately 10 feet (left image) and 5 feet
(right image) along different street frontages for the same corner apartment building. These ground level units all have
their own private unit access from the sidewalk and are elevated above the sidewalk to enhance the privacy to the
units. The landscaping elements, brick posts, split-faced concrete block stoop walls, and black metal railings help to
provide an attractive and effective transition between the public and private realms.
Page 70 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 19
Auburn Citywide Design-Standards_2026-02-24
Guidelines and examples of ground-level residential frontages
Good examples: Upper left image includes a stoop design with brick terraced planters and low wrought iron fences.
Upper right and lower left images include low wrought iron fences that separate the sidewalk/pedestrian walkway from
the private open space. Lower center and right images include stoop designs with sidewalk level planters and concrete
terrace planters.
Bad examples: Despite the raised ground level, the shallow setback design in the left image above is insufficient to meet
the purpose of the standards. In the above right image, the upper level building cantilever doesn’t meet the standards
and creates a cold “cave stoop” like form. The large areas of unscreened concrete walls in both examples are
undesirable.
Page 71 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 20
Auburn Citywide Design-Standards_2026-02-24
2.9 Through-block connection frontage standards.
(1) Purpose. To promote through-block connection frontage designs that enhance the character and
safety of such connections.
(2) Applicability. These standards apply to development adjacent to through-block connections, when
required (see Section 3.4).
(3) Standards. Many, but not all standards depend on the type of connection and the adjacent use.
Specifically:
(a) Non-residential building elevations (including mixed-use development with ground floor
commercial uses) facing a through-block connection are subject to Other/Undesignated block
frontage standards in Section 2.7, except that such building elevations must feature at least 10
percent window transparency to enhance the safety and visibility of the trail and connection.
(b) Residential developments adjacent to a through-block connection are subject to both the
Landscaped block frontage standards in Section 2.5 and Ground-floor residential frontage
standards in Section 2.8.
Good examples of through-block connections in a residential context
2.10 Corner site clarifications.
Where a property fronts onto more than one street, each building frontage must comply with the
standards for the block-frontage upon which it fronts, with the following clarifications:
(1) Entrances. For corner sites, entrances may be provided on both streets, but only one entrance is
required.
(2) Transparency and weather protection standards associated with corner storefronts. The block
frontage containing the entry is subject to the full Storefront transparency and weather protection
standards in Table 2.4. The secondary block frontage associated with the corner establishment must
contain at least 50 percent of the required transparency and weather protection for Storefronts.
Page 72 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 21
Auburn Citywide Design-Standards_2026-02-24
2.11 Mixed-use street corner standards.
(1) Applicability/purpose. The mixed-use street-corner requirements apply to new mixed-use
developments located on street corner sites. The intent is to accentuate these high visibility
developments to the public and create a unique sense of place.
(2) Standards. At least one of the following special features must be included:
(a) Corner plaza.
(b) Cropped building corner with a special entry feature.
(c) Decorative use of building materials at the corner.
(d) Distinctive façade articulation.
(e) Sculptural architectural element.
(f) Other decorative elements that meet the purpose of the standards.
Acceptable high visibility street corner examples
The letters on the images refer to the special feature options above that are integrated into the design.
Page 73 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 22
Auburn Citywide Design-Standards_2026-02-24
Chapter 3 - Site Planning
3.1 Useable residential recreational space.
(1) Purpose.
(a) To create useable space that is suitable for leisure or recreational activities for residents.
(b) To create open space that contributes to the residential setting.
(2) Usable residential recreational space.
(a) All residential developments, including residential portions of mixed-use development, must
provide minimum usable recreational space equal to 10 percent of dwelling unit floor area. This
includes all dwelling units, but excludes hallways, lobbies, and other common areas. The
required recreational space may be provided in a combination of ways:
(i) Shared outdoor space. All of the required recreational space may be in the form of shared
outdoor space available to all residents and meeting the requirements of subsection (b)
below. Shared roof-decks located on the tops of buildings are addressed in subsection (v)
below.
(ii) Ground/grade-level individual outdoor space. All of the required recreational space for a unit
may be provided by ground-level outdoor space that is abutting and directly accessible to the
subject unit. Such recreational spaces must be:
(A) Outdoor spaces may be located in the front, side, or rear yard provided they are generally
level, feature no dimension less than ten-feet, and enclosed by a fence, railing, and/or hedge
at least 32-inches in height to qualify
(B) Private porches may qualify as outdoor space provided they are at least 36-square-feet in
area, with no dimension less than six-feet.
Individual ground-level open space that is in excess of minimum requirements must not be
used in the calculations for determining the minimum usable recreational space requirements
for other units in the development.
(iii) Balconies and other similar private outdoor spaces. Up to 50 percent of the required
recreational space for a unit may be provided by private balconies provided such spaces are
at least 36-square-feet in area, with no dimension less than four-feet (not including railings),
to provide a space usable for human activity.
Note: Balconies that encroach over the public right-of-way will require a permit meeting the
standards of ACC 12.60 and ACC 12.60.050.
(iv) Common indoor recreation-areas. Up to 50 percent of the required recreational space may
be provided by common indoor recreation areas meeting the following conditions:
(A) The space must meet ADA standards and must be located in a visible area, such as near an
entrance, lobby, or high traffic corridors.
(B) The space must be designed specifically to serve interior recreational functions and not
merely be leftover unrentable space used to meet the open space requirement.
(v) Shared roof-decks. For apartment buildings, up to 50 percent of the required recreational
space may be provided by shared roof-decks located on the top of buildings which are
Page 74 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 23
Auburn Citywide Design-Standards_2026-02-24
available to all residents and meet the requirements below. For mixed-use buildings, 100
percent of the required recreational space may be provided by shared roof-decks. Design
requirements:
(A) Space must feature hard surfacing, provide amenities such as seating areas, landscaping,
and/or other features that encourage use.
(B) Space must integrate landscaping elements (at least 20 percent of the space) that enhance
the character of the space and encourage its use.
Rooftop deck examples
(b) Shared recreational space design requirements. Shared recreational space can include
landscaped courtyards or decks, entrance plazas, gardens with walkways, children’s play areas,
pools, and water features provided they are accessible to all residents of the development.
Accessible areas used for storm water retention, infiltration, or other multipurpose recreational
and/or green spaces that meet the design criteria herein may qualify as shared recreational
space.
Special requirements for shared recreational spaces include the following:
(i) Shared recreational space must be located in centralized areas that are visible from units
within the development.
(ii)Shared recreational space must feature no dimension less than 15-feet in order to provide
functional leisure or recreational activity. Wider minimum dimensions are required
perpendicular to building elevations containing windows of dwelling units whose only solar
access is from the applicable building wall. Specifically:
(A) 20-feet minimum for such elevations up to three-stories tall.
(B) 25-feet minimum for such elevations four-stories tall.
(C) 30-feet minimum for such elevations five or more stories tall.
(iii)Shared recreational space must feature paths, landscaping, seating, and lighting plus play
structures, sports courts, and/or other pedestrian amenities to make the area more
functional and enjoyable for a range of users.
(iv)Stairways and service elements located within or on the edge of shared recreational space
must not be included in the open space calculations.
(v) Shared porches may qualify as shared recreational space, provided they are at least eight-feet
in depth and 96-square-feet in total area.
Page 75 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 24
Auburn Citywide Design-Standards_2026-02-24
Shared recreational space examples
The upper left example is a courtyard over a parking deck. Notice the transition elements between the
courtyard and adjacent residential units. The upper right courtyard is shared by ground -level commercial uses
and apartments above.
The left image above includes a covered gathering space with outdoor grills adjacent to a landscaped commons
with a central walkway. The right image is an example of shared indoor recreation space.
The left image above includes a turf play area with mounds for fun play. The right image shows traditional play
equipment.
Page 76 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 25
Auburn Citywide Design-Standards_2026-02-24
Shared recreational space – minimum widths when abutting building elevations
containing windows of dwelling units whose only solar access is from the applicable
building wall
20-feet minimum for such
elevations up to three-stories
tall.
25-feet minimum for such
elevations four-stories tall.
30-feet minimum for such
elevations five or more stories
tall
Page 77 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 26
Auburn Citywide Design-Standards_2026-02-24
3.2 Public Plazas and pedestrian-oriented space.
(1) Purpose.
(a) To encourage plazas and other pedestrian oriented spaces in downtown that enhance the
public’s opportunity for active and passive activities, such as dining, resting, people watching, and
recreational activities.
(b) To enhance the comfort and leisure capabilities of public plazas.
(c) To enhance the development character and attractiveness of the Downtown Urban Center.
(2) Applicability. These standards apply when publicly accessible plazas are included in the
development.
(3) Public plaza standards.
(a) Public plazas must abut and be within three feet in elevation of a public sidewalk. Ramps must be
provided consistent with ADA standards.
(b) Public plazas must be at least 25 feet wide.
(c) At least ten percent of the plaza area shall be planted with trees and other vegetation. Planters
with trees, shrubs, or other vegetation are permitted to count towards the ten percent.
(d) At least 20 percent of the plaza shall have physical or natural shade structures. Seated areas with
umbrellas, planted trees that will have a canopy radius of at least 2.5 feet, canopies, and other
shade structures are permitted to count towards the 20 percent.
(e) At least two feet of seating area (a bench or ledge at least 16-inches deep and appropriate
seating height) or one individual seat per 60-square-feet of plaza area or open space. Moveable
seating may be used to meet up to 75 percent of this requirement.
(f) Desirable public plaza features (to be encouraged) include site furniture, artwork, drinking
fountains, water features, kiosks, play structures, or other similar features.
Example of site development integrating pedestrian-oriented space
Page 78 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 27
Auburn Citywide Design-Standards_2026-02-24
All of the above spaces front onto sidewalks and include bordering storefronts to help enliven the spaces. The
bottom plaza includes a crushed rock surface, with concrete pathways on the side to facilitate pedestrian
movement. Note the mix of fixed and movable seating options.
Page 79 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 28
Auburn Citywide Design-Standards_2026-02-24
3.3 Parking lots, garages, and drive access design.
(1) Purpose.
(a) To create a safe, convenient, and efficient network for vehicle circulation and parking that
minimizes conflicts with pedestrian circulation and activity.
(b) To mitigate the visual impact of parking lots on the streetscape and development context.
(c) To enhance the function, safety, and visual appearance of parking garages.
(2) Parking lot pedestrian circulation and design.
The project must provide an integrated and connected pedestrian circulation network that
encourages walking and functions as one of the defining features of the development. Specifically:
(a) Pedestrian connections not less than five feet wide shall be provided through parking lots where
they separate building entrances from sidewalks and/or transit stops. Pedestrian connection
walkways are required to meet minimum ADA requirements.
(b) Pedestrian connections through parking lots shall be clearly defined by at least two of the
following:
(i) Six-inch vertical curb in combination with a raised walkway.
(ii) Textured paving, including across vehicular lanes, such as unit pavers, stamped and scored
concrete.
(iii) Bollards.
(iv) Trellis.
(v) Continuous landscape area on at least one side of the walkway that is at least three feet
wide.
(vi) Pedestrian-scale lighting.
(c) Parking lot walkways. For developments with large surface parking lots, one walkway shall be
provided for every four rows of parking, or at a maximum spacing of 200 feet.
(d) Crosswalks. Crosswalks are required when a walkway crosses an on-site paved area accessible
to vehicles.
(e) Raised crosswalks (speed tables). On sites larger than one acre, all crosswalks near major
building entrances, parking garage entries, vehicular entries to the site, and other high-traffic
areas shall be vertically raised to sidewalk level. The purpose of raised crosswalks is to provide a
continuous walking or rolling surface, increase the visibility of pedestrians, and slow the speed of
vehicular traffic. This requirement does not apply to crosswalks crossing public roadways.
(3) Through-block connection standards for the development of large sites.
Through-block connections may include private streets, shared pedestrian and vehicular access
routes, and other non-motorized routes that are intended to run between streets through an entire
block. The standards herein allow flexibility in the type of connections best suited for the particular
development and its use mix. The M and I zones are exempt from this standard. Specific regulations
for such through-block connections:
(a) The maximum distance between a street and through block connection or between through-
block connection is 500 feet.
Page 80 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 29
Auburn Citywide Design-Standards_2026-02-24
Development sites with smaller dimensions are not required to integrate through-block
connections with new development.
(b) Departures and exceptions to the through-block connection standards:
(i) The Director may approve a departure from the dimensional standards set forth in
subsection (a) by up to 25 percent provided the quality of the through-block connection
exceeds minimum design standards.
(ii) The Director may approve an exception from the dimensional standards set forth in
subsection (a) where topography, existing uses/construction, or other geographic conditions
prevent compliance or impose an unusual hardship on the applicant, provided the proposed
design maximizes pedestrian and vehicular connectivity on the site given the constraints.
(c) Public access easement. Such through-block connections shall be provided within a public access
easement.
(d) Alignment. Specific alignments for the through-block connections will be developed during the
development review process for applicable sites.
(e) Accessibility. Through-block connections must be accessible to the public at all times and may
take a variety of forms, depending on the block size and use mix, as specified in subsection (F),
Through-block connections, below.
(f) Cantilever design. Buildings may project or cantilever into minimum required easement areas on
building levels above the connection provided a 13-foot, six-inch vertical clearance is maintained
and all other regulations are met.
(g) Through-block connection types. Unless otherwise noted below and elsewhere in this chapter,
required through-block connections may take any of the following forms set forth below. A
combination of designs set forth above may be used for each connection.
(i) Private street. Such streets shall comply with the Engineering Design and Construction
Standards.
(ii) Alley. Alleys shall comply with the Engineering Design and Construction Standards.
(iii) Shared lane. The shared-lane approach can work well for lower traffic situations and helps
to reduce the total space needed to accommodate access. They must include a 20-foot wide
minimum two-way shared travel lane within a 32-foot wide public access easement. Parallel
or angled parking pockets may be integrated into the lane provided the public access
easement is widened accordingly. Landscape planters with a mixture of trees, shrubs, and
ground cover must be integrated on at least one side of the shared-lane.
(iv) Landscaped passageway design. This includes an eight-foot minimum width paved pathway
within a 24-foot public access easement. Six-foot minimum landscaping strips (with a mixture
of trees, shrubs, and ground cover) are required on each side of the path.
(v) Urban passageway design. This is a 12-foot minimum width concrete or unit paver walkway
within a public access easement (same width) with buildings generally on each side. The
building elevations on each side of an Urban passageway must include 40 percent
transparency between 30 inches and eight feet above grade. Weather protection is required
over all building entrances (at least three feet deep across the full width of the entrance).
Page 81 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 30
Auburn Citywide Design-Standards_2026-02-24
Shared lane examples
Image courtesy eya.com
Page 82 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 31
Auburn Citywide Design-Standards_2026-02-24
Landscaped and urban passageway examples
Landscaped passageway examples above and urban passageway examples below, though the lower right is a
blended example of urban and landscaped passageway.
(4) Vehicular access and design.
(a) Driveways. Driveways, where permitted by applicable Block Frontage Standards in Chapter 2,
shall meet the standards of the Engineering Design and Construction Standards, including, but
not limited to, standards for intersection spacing, distance from crosswalks, and width.
(b) Parking lot location and design. Parking lot location standards are set forth in the Block
Frontage Standards in Chapter 2. All other parking lot design standards are set forth in ACC
Chapter 18.52 unless modified herein.
(i) See subsection (2) above for interior parking lot pathways.
(ii) See subsection (5) below for parking lot landscaping standards.
(c) Garage and parking structures. Where such structures are located along a public street, they are
subject to applicable block frontage standards as set forth in Chapter 2. Supplemental standards:
(i) The ground level of free-standing parking structures shall include at least three of the
following elements along block frontages and/or other elevations adjacent to internal streets
and other required through-block connections, customer and/or resident parking lots, and
pedestrian-oriented space:
Page 83 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 32
Auburn Citywide Design-Standards_2026-02-24
(A) Pedestrian scale signs, associated with storefront uses integrated into the ground floor
frontage.
(B) Canopies and other forms of weather protection where the parking structure integrates
storefronts along the ground floor frontage.
(C) Plinths for columns.
(D) Ground level and/or terraced planting beds integrated between the sidewalk and the
parking structure.
(E) Ornamental tilework.
(F) Glass elevator and/or stair tower.
(G) Departure. Other design features will be considered provided they meet the purpose of
this section.
(ii) Upper levels of structured parking shall be screened or treated architecturally by two or
more of the following:
(A) Roughly square openings rather than horizontal.
(B) Planting designed to grow on the façade.
(C) Louvers.
(D) Expanded metal panels.
(E) Decorative metal grills.
(F) Spandrel (opaque) glass.
Departure. Other design features will be considered provided they meet the purpose of this
section.
(iii) Parking garage entries and service area entries should be well-integrated into the design of
the building and should not dominate the streetscape. They should be designed and sited to
complement, not subordinate, the pedestrian entry.
(iv) Where vehicles enter and exit a parking garage or service area across a sidewalk or internal
walkway, direct visibility between pedestrians and motorists shall be provided. Possible
treatments to meet this requirement may include setback entries, cropped wall corners, wall
openings, or other treatments to enhance safety and visibility. Treatments should also include
pavement markings or changes in pavement materials. Mirrors and electronic visual/audio
warnings alone are not acceptable methods of visibility.
(v) Parking garage entries shall meet the standards of the Engineering Design Standards, Chapter
10, which details requirements for adding visibility and/or auditory treatments between
pedestrians and motorists.
(vi) Garage entry doors and gates, if provided, shall be at least 50 percent transparent between
the bottom and top of the door or gate to enhance the safety of garage users.
(v) Lighting fixtures within garages are encouraged to be screened from view from the street.
(5) Parking lot landscaping.
(a) Surface parking lots consisting of ten or more stalls shall feature landscaped planter beds at a
ratio of one to every six stalls. Each planter bed shall include at least one tree, a minimum
caliper of two inches at the time of planting.
Page 84 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 33
Auburn Citywide Design-Standards_2026-02-24
(b) The minimum planter size shall be 100 square feet. Planters shall be protected by concrete
curbs and shall also feature shrubs and/or groundcover.
(c) Surface parking lots located adjacent to any street (excluding alleys) shall be screened by one or
a combination of the following:
(i) Low walls made of decorative concrete, masonry, or other similar material, not exceeding a
maximum height of 30 inches.
(ii) Raised planter walls (not exceeding a total height of 30 inches) planted with shrubs (a
minimum of 80 percent of which must be evergreen).
(iii) Landscape plantings consisting of trees (of which at least 80 percent are deciduous) and
shrubs and groundcover materials (of which at least 80 percent are evergreen).
(iv) All plant material used for parking lot screening shall provide clear views between 30 inches
and eight feet above the ground surface, for visibility and safety.
(v) Planting areas shall be a minimum of five feet in width and shall be irrigated.
DEPARTURES will be considered provided the design enhances the function, safety, convenience, or
visual appearance of the parking lot and mitigates the visual appearance on the streetscape and
development context.
Parking lot street buffer examples
Page 85 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 34
Auburn Citywide Design-Standards_2026-02-24
3.4 Service areas and mechanical equipment.
(1) Purpose.
(a) To minimize adverse visual, odor, and noise impacts of mechanical equipment, utility cabinets
and service areas at ground and roof levels.
(b) To provide adequate, durable, well-maintained, and accessible service and equipment areas.
(c) To protect residential uses and abutting properties from impacts due to location and utilization
of service areas.
(2) Location of ground related service areas and mechanical equipment.
(a) Service areas (e.g., loading docks, trash dumpsters, compactors, recycling areas, electrical panels,
and mechanical equipment areas, etc.) must be located for convenient service access while
avoiding negative visual, auditory, olfactory, or physical impacts on the streetscape environment,
pedestrian-oriented spaces, uses within the development, and abutting residentially zoned
properties.
(b) Exterior loading areas. Exterior loading areas for commercial uses must not be located within
20-feet of a residentially zoned property. Where the director finds that this is the only option
for locating an exterior loading area, design measures will be required to mitigate impacts to
adjacent uses, such as adding a masonry wall at least eight-feet high.
(c) Service areas must not be visible from the sidewalk and abutting properties. Where the director
finds that the only option for locating a service area is an area visible from a street, internal
walkway or pedestrian area, or from an abutting property, the area must be screened with
structural and/or landscaping screening measures.
(3) Screening of ground related service areas and mechanical equipment.
Service elements are encouraged to be integrated within the structure. Where they are not
provided within the structure, the following standards apply:
(a) Where screening of ground-level service areas is required [see subsection (2) above], the
following applies:
(i) A structural enclosure (including gates) must be constructed of masonry, heavy-gauge metal,
or decay-resistant material that is also used with the architecture of the main building.
Alternative materials other than those used for the main building may be allowed if the
finishes are similar in color and texture or if the proposed enclosure materials are more
durable than those for the main structure. The walls must be sufficient to provide full
screening from the affected roadway, pedestrian areas and adjacent use. The enclosure may
use overlapping walls to screen dumpsters and other materials.
(ii) Where the interior of a service enclosures is visible from surrounding streets, walkways, and
buildings, an opaque or semi-opaque horizontal cover or screen must be used to mitigate
unsightly views. The horizontal screen/cover should be integrated into the enclosure design
(in terms of materials and/or design).
(b) Where loading docks are sited along block frontages (only allowed when no other reasonable
options are available as determined by the director), they must be designed to minimize impacts
on the pedestrian environment. Standards:
(i) Configure loading docks/bays to minimize their frontage length along blocks.
Page 86 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 35
Auburn Citywide Design-Standards_2026-02-24
(ii) Integrate architectural and/or landscaping design features to screen loading dock elements
and add visual interest to pedestrians along adjacent sidewalks. See Blank Wall provisions of
Section 4.5 for standards and examples.
(4) Utility meters, electrical conduit, and other service utility apparatus.
(a) Utility equipment such as power and gas meters, electrical boxes, and small-scale battery
storage systems mounted in a location visible from the street, pedestrian walkway, shared
recreational space, or shared auto courtyards, shall have at least one of the following
treatments:
(i) Screened with vegetation or landscaping.
(ii) Integrated into the building’s architecture or screened with decay-resistant material similar
in color and texture to the main building.
(iii) Wrapped with a City approved utility wrap.
(b) Project designers are strongly encouraged to coordinate with applicable service providers early
in the design process to determine the best approach to meet these standards.
Utility meter location and screening - good and bad examples
Place utility meters in less visible locations. The lower left example is successfully tucked away in a less visible
location and screened by vegetation. The right image is poorly executed and would not be permitted in such
visible locations (along the sidewalk). Such meters must be coordinated and better integrated with the
architecture of the building.
Page 87 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 36
Auburn Citywide Design-Standards_2026-02-24
Chapter 4 - Building Design
4.1 Building massing and articulation.
(1) Purpose.
To employ façade articulation techniques that reduce the perceived scale of large buildings and add
visual interest from all observable scales.
(2) Façade-articulation. All buildings except free-standing parking structures must include façade-
articulation features at maximum-specified intervals to create a human-scaled pattern.
(a) Maximum facade-articulation intervals:
(i) Storefronts: 35 feet. Buildings 50 feet wide or less are exempt.
(ii) Large footprint non-residential buildings (individual establishments with a building footprint of
more than 50,000 square feet). 75 feet.
(iii) Residential buildings: 30 feet. Buildings 60 feet wide or less are exempt.
(b) Articulation features. At least two of the following articulation features must be employed for all
buildings in compliance with the maximum-specified façade-articulation intervals.
(i) Use of a window-fenestration pattern.
(ii) Use of weather protection features. An example is a different canopy for each articulation
interval (rather than a continuous canopy).
(iii) Use of vertical piers/columns (applies to all floors of the façade, excluding upper level
stepbacks).
(iv) Change in building height or roofline with a difference in height, slope or pitch, direction, or
shape (such as towers or dormers).
(v) Change in building material and/or siding style (applies to all floors of the façade, excluding
upper-level stepbacks).
(vi) Vertical elements such as a trellis with plants, green wall, art element that meet the purpose
of the standard.
(vii) Providing vertical building modulation of at least 12-inches in depth if tied to a change in
roofline or a change in building material, siding style, or color. Balconies may be used to
qualify for this option if they are recessed or projected from the façade by at least 18-inches.
Note: Façade-articulation features that encroach over the public right-of-way will require a
permit meeting the standards of ACC 12.60 and ACC 12.60.050.
DEPARTURES will be considered provided they meet the purpose of the standards and the
design criteria below.
Page 88 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 37
Auburn Citywide Design-Standards_2026-02-24
Façade articulation examples.
All three buildings above include a combination of window patterns, vertical building modulation, and changes in
building material/siding style. The varying styles of balconies in each also help to articulate the facades. The mixed -
use example on the let also uses separate awnings above the storefront to articulate the facade. The middle image
also uses roofline modulation.
The buildings on the left uses a combination of window patterns, vertical building modulation, roofline modulation,
and changes in building material/siding style. The middle image uses window patterns, awnings, and vertical piers.
The right image uses window patterns, vertical building modulation, and weather protection elements.
(c) DEPARTURE criteria associated with articulation standards. Proposals must meet the purpose
of the standards. The following criteria will be considered in determining whether the proposed
articulation treatment meets the “purpose”.
(i) Consider the type and width of the proposed articulation treatment and how effective it is in
meeting the purpose given the building’s current and desired context if a subarea plan is in
effect where the building is proposed.
(ii) Consider the applicable block-frontage designation. Undesigned block-frontages warrant
more flexibility than Mixed block-frontages.
(iii) Consider the size and width of the building. Smaller buildings (less than 120-feet wide)
warrant greater flexibility than larger buildings.
(iv) Consider the quality of façade materials in concert with doors, windows, and other façade
features and their ability to add visual interest to the street from a pedestrian scale and more
distant observable scales.
Page 89 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 38
Auburn Citywide Design-Standards_2026-02-24
(3) Maximum façade length. Facades of buildings longer than 150 feet and containing four or more
stories must include at least one of the following features to break up the massing of the building
and add visual interest. Freestanding parking structures are exempt from this standard.
(a) Provide vertical building modulation at least six-feet deep and 15-feet long. For multi-story
buildings, the modulation must extend through at least one-half of the building floors.
(b) Use of a contrasting vertically modulated design component featuring all the following:
(i) Utilizes a change in building materials that effectively contrast from the rest of the façade.
(ii) Component is modulated vertically from the rest of the façade by an average of six inches.
(c) Façade employs building walls with contrasting articulation that make it appear like multiple
distinct buildings. To qualify for this option, these contrasting façades must employ all the
following:
(i) Different building materials and/or configuration of building materials.
(ii) Contrasting window design (sizes or configurations).
(d) DEPARTURES to the above standards will be considered provided the design meets the
purpose of the standards. Supplemental consideration for approving alternative designs:
(i) Width of the façade. The larger the façade, the more substantial articulation/ modulation
features need to be.
(ii) Block-frontage designation and visibility/street context. Mixed block-frontages warrant the
most scrutiny than Undesignated block frontages, and narrow side streets warrant more
flexibility than collector or arterial streets.
(iii) The type of articulation treatment and how effective it is in meeting the purpose given the
building’s context.
Illustrating maximum façade length standards and good and bad examples.
Less than 150’ long: Meets standard
More than 150’ long: Does not meet standard
Page 90 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 39
Auburn Citywide Design-Standards_2026-02-24
Illustrating maximum façade length standards and good and bad examples.
Building incorporates a courtyard along the façade (technique #1 noted above) to effectively break it up into
smaller components: Meets standard.
The left building uses technique # 1 (vertical building modulation at least six -feet deep and 15-feet wide). The right
building uses technique #2 (contrasting vertical modulated design component) together with different window
fenestration designs on each side. Both examples are effective in breaking up the perceived scale of the building
and adding visual interest.
Page 91 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 40
Auburn Citywide Design-Standards_2026-02-24
4.2 Building details.
(1) Purpose.
(a) To encourage the incorporation of design details and small-scale elements into building façades
that are attractive at a pedestrian scale.
(b) To integrate window design that adds depth, richness, and visual interest to the façade.
(2) Façade details – Storefront block frontages and other storefront designs. Storefront
buildings must be enhanced with appropriate details. Such buildings must employ at least one detail
element from each of the three categories below for each façade articulation interval (see
subsection 4.1.2).
(a) Window and/or entry treatment, such as:
(i) Transom windows.
(ii) Roll-up windows/doors. [Use of this feature exempts buildings from having to meet detailed
standards in subsections (b) and (c) below.]
(iii) Recessed entry.
(iv) Decorative door.
(v) Other decorative or specially designed window or entry treatment could be proposed via
DEPARTURE provided they meet the purpose of the standards.
Examples of architectural elements and façade attachments.
i: Transom windows iii: Recessed entry
ii: Roll-up or similar windows/doors iv: Decorative door.
Page 92 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 41
Auburn Citywide Design-Standards_2026-02-24
Examples of architectural elements and façade attachments.
(b) Architectural elements and façade attachments, such as:
(i) Custom-designed weather protection element such as a steel canopy, glass, or retractable
awning. Custom-designed cloth awnings may be counted as a detail provided they are
constructed of durable, high-quality material.
(ii) Decorative rooflines, which could take a variety of forms. It could include an ornamental
molding, entablature, frieze or other roofline device visible from the ground level. If the
roofline decoration is in the form of a linear molding or board, then the molding or board
must be at least 8-inches wide. Such details could occur at an intermediate floor, where the
upper floors are set back beyond the front façade. Examples could also include a modern
interpretation of a traditional cornice line with distinct detailing.
(iii) Bay windows, trellises, towers, and similar elements.
(iv) The use of neon in artwork or to emphasize building features.
(v) Other architectural element or façade attachment details could be proposed via
DEPARTURE provided they meet the purpose of the standards.
Page 93 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 42
Auburn Citywide Design-Standards_2026-02-24
Examples of architectural elements and façade attachments.
i: Custom designed weather protection iii: Bay windows, trellises, towers, etc.
Left: retractable awning. Right: custom decorative canopy
Decorative tower
ii: decorative rooflines
v: Other details that meet the
purpose of the standards.
Left: decorative cornice and top floor. Right: decorative
projecting cornice feature.
Custom hanging bike rack and repair
station integrated as a storefront design
element
(c) Building material details, including:
(i) Use of decorative building materials/use of building materials. Examples include decorative
use of brick, tile, or stonework.
(ii) Decorative kick-plate, pilaster, base panel, or other similar feature.
(iii) Decorative belt course.
(iv) Decorative building-mounted light fixtures.
(v) Hand-crafted material, such as special wrought iron or carved wood.
(vi) Other building material details could be proposed via DEPARTURE provided they meet the
purpose of the standards.
DEPARTURES for façade detail standards of subsection (2) of this section will be considered
provided the façade (at the overall scale and at the individual articulation scale) meets the purpose
of the standards.
Page 94 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 43
Auburn Citywide Design-Standards_2026-02-24
Examples of Examples of building material details that enhance the
visual intrigue of the building
i: Decorative building materials iii: Decorative light fixtures.
ii: Decorative kick-plate, pilaster, base panel, or similar
iv: Hand-crafted material or other details that meet the purpose of the standards.
Page 95 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 44
Auburn Citywide Design-Standards_2026-02-24
4. Articulated building entries. The primary building entrance for an office building, hotel,
apartment building of more than 50 units, or community-based facility or other multi-story
commercial building must be designed as a clearly defined and demarcated standout architectural
feature of the building. Such entrances must be distinguishable from regular storefront entrances on
the building. Such entries must be scaled proportional to the building.
Acceptable building entry examples.
Page 96 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 45
Auburn Citywide Design-Standards_2026-02-24
4.3 Building materials.
(1) Purpose.
(a) To encourage the use of durable, high quality, and urban building materials that minimize
maintenance cost and provide visual interest from all observable vantage points.
(b) To promote the use of a distinctive mix of materials that helps to articulate façades and lends a
sense of depth and richness to the buildings.
(c) To place the highest priority on the first floor in the quality and detailing of materials at the
pedestrian scale.
(2) Applicability. Standards in this section apply to only to mixed-use developments.
(3) Special conditions and limitations for the use of certain cladding materials.
(a) Concrete block (a.k.a. Concrete Masonry Unit or CMU) may be used as a secondary cladding
material (no more than 1/3 of total façade cladding) on all building façades and other building
elevations facing parks, pedestrian-oriented spaces, and containing primary building entrances
provided it is incorporated with other permitted materials.
DEPARTURES will be considered for alternative designs that use concrete block as the primary,
but not the only, cladding material provided the design incorporates a combination of textures
and/or colors to add visual interest. For example, combining split or rock-façade units with
smooth blocks can create distinctive patterns. The figures below illustrate acceptable concrete
block use/designs.
Page 97 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 46
Auburn Citywide Design-Standards_2026-02-24
Acceptable concrete block use/design.
The above building uses smooth-faced CMU as
a contrasting feature that helps to highlight the
main building entry. The simple design helps to
add emphasis to the doors, canopy and
decorative sconce lights.
The above building illustrates an acceptable departure example,
as CMU is used as the primary cladding material. Note the use
of beige split-façade CMU’s above each of the awnings and
coupled with the use of smooth-faced gray CMU’s on the
vertical columns (which employ black accent tiles for added
interest).
(b) Metal siding may be used on all building façades and other building elevations facing parks,
pedestrian-oriented spaces, and containing primary building entrances provided it complies with
the following standards:
It must feature visible corner molding and trim and does not extend to the ground-level of non-
residential and mixed-use buildings and no lower than two-feet above grade for residential
buildings. Masonry, concrete, or other durable material must be incorporated between the
metal siding and the ground plane.
DEPARTURES will be considered provided the material’s integration and overall façade
composition meets the purpose of the standards.
Page 98 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 47
Auburn Citywide Design-Standards_2026-02-24
Acceptable metal siding examples
The upper building examples successfully use metal siding more as an accent element to help articulate the façade.
Metal siding is the primary material for the lower building examples. The lower left building integrate subtle
changes in color to go with articulation features and design details. The right building uses an intricate scaling
pattern combined with recessed windows to add depth and interest to the façade.
(c) Standards for the use of Exterior Insulation and Finish System (EIFS). Such material/finishes may
be used when it complies with the following:
i. EIFS is limited to no more than 20 percent of the total façade area and may not be the
primary cladding material on non-residential and mixed-use buildings.
ii. EIFS must feature a smooth or sand finish only.
iii. EIFS must be trimmed in wood, masonry, or other material and must be sheltered from
weather by roof overhangs or other methods.
iv. EIFS must not be used on the ground floor of facades containing non-residential uses.
DEPARTURES will be considered provided the material’s integration and overall façade
composition meets the purpose of the standards.
Page 99 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 48
Auburn Citywide Design-Standards_2026-02-24
Acceptable and unacceptable EIFS examples.
The upper building examples mix EIFS with brick and other materials and integrate trim details around windows to
add a sense of depth to the façade. The lower left building uses EIFS is between the window and sidewalk - this
design is prohibited. The lower right building uses EIFS as the primary siding material, which is prohibited.
Page 100 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 49
Auburn Citywide Design-Standards_2026-02-24
(d) Cementitious wall board paneling/siding may be used provided it meets the following provisions:
i. Cement board paneling/siding may not be used on ground-level elevation (containing non-
residential uses) of mixed-use building facades.
ii. Where cement board paneling/siding is the dominant siding material, the design must
integrate a mix of colors and/or textures that are articulated consistent with windows,
balconies, and modulated building surfaces and are balanced with façade details that add visual
interest from the ground-level and adjacent buildings.
DEPARTURES will be considered provided the material’s integration and overall façade
composition meets the purpose of the standards.
Acceptable and unacceptable cementitious wall board examples.
The above buildings use cementitious wall board in different textures and colors to help articulate the façade.
The wall board panels covering a large area in a single color in the left building would not meet the purpose of the
standards. The right building’s design is a better example and combines larger panels (dark maroon color) with
horizontal wall board siding (beige color) as effective articulation features. Below is a similar acceptable example.
Page 101 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 50
Auburn Citywide Design-Standards_2026-02-24
4.4 Blank wall treatment.
(1) Purpose.
(a) To avoid untreated blank walls.
(b) To retain and enhance the character of Auburn’s streetscapes.
(2) Blank wall definition. “Blank wall” means:
(a) For storefront and other buildings placed within ten feet of the sidewalk, a ground floor wall or
portion of a ground floor wall over 10-feet in height and a horizontal length greater than 15-feet
and does not include a transparent window or door.
(b) For all other buildings, a ground floor wall or portion of a ground floor wall over 10-feet in
height and a horizontal length greater than 30-feet and does not include a transparent window
or door.
Blank wall definition.
(3) Blank wall treatment standards. Untreated blank walls adjacent to a public street, pedestrian-
oriented space, common usable open space, or pedestrian walkway are prohibited. Methods to treat
blank walls can include:
(a) Display windows at least 16-inches of depth to allow for changeable displays. Tack-on display
cases do not qualify as a blank wall treatment.
(b) Landscape planting bed at least five-feet deep or a raised planter bed at least two-feet high and
three-feet deep in front of the wall with planting materials that are sufficient to obscure or
screen at least 60 percent of the wall’s surface within three years.
(c) Installing a vertical trellis in front of the wall with climbing vines or plant materials.
(d) Installing a mural. Commercial advertisements are not permitted on such murals. The use of
neon in artwork is permitted.
DEPARTURES. Other design including special building detailing that adds visual interest at a
pedestrian scale will be considered. Such detailing must use a variety of surfaces.
For large visible blank walls, a variety of treatments may be required to meet the purpose of the
standards.
Page 102 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 51
Auburn Citywide Design-Standards_2026-02-24
Blank wall treatment examples.
Buildings A-C feature acceptable treatments including a combination of high quality materials and landscaping (A),
decorative lighting/sculptural element (B), and special building detailing (C). The display cases in Building D don’t
meet the 16” depth requirement, nor do they meet the purpose of the standards.
Page 103 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 52
Auburn Citywide Design-Standards_2026-02-24
(4) Firewalls. Firewalls along property lines are exempt from the above standards, but where they are
visible to the public (from the adjacent street), they must be designed to provide visual interest from
all observable distances. Examples may include the use of varying materials, textures, and/or colors,
the use of green or living walls, and/or the use of modulated building walls to form design patterns.
Murals are also encouraged as a firewall treatment. Commercial advertisements are not permitted
on such murals.
Acceptable firewall design where visible to the public.
The left images uses a combination of paint bands and climbing vines to enhance the appearance of this large
exposed firewall. The building in the right image uses simple scoring patterns and change in materials and color
on part of the top floor to add visual interest.
Plain-gray concrete block firewalls
such as this are not allowed when
visible from the street.
Page 104 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 53
Auburn Citywide Design-Standards_2026-02-24
4.5 Rooftop services area and mechanical equipment.
(1) Purpose.
To obscure service and mechanical equipment from the visual sightlines of people walking through
Auburn.
(2) Rooftop equipment screening.
(a) All rooftop mechanical equipment, including air conditioners, heaters, vents, and similar
equipment must be effectively screened from public view. Screening shall be integrated with the
architecture of the building.
Examples of how to screen roof-mounted mechanical equipment
The left illustration shows how rooftop mechanical equipment can be located and screened effectively. The right
images shows effective location and screening, including side walls and a trellis to screen views from taller
surrounding buildings.
Page 105 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 54
Auburn Citywide Design-Standards_2026-02-24
Chapter 5 – Guidelines For All Developments
5.1 Climate Friendly Design.
(1) Purpose.
To encourage design techniques that reduce greenhouse gas emissions (GHG) and help buildings be
more resilient to extreme heat and wildfire smoke.
(2) Applicability. The following standards are recommended, not required.
(3) Guidelines. Projects are encouraged to incorporate one or more of the following:
(a) Design buildings in accordance with the principles and guidelines of Passive House, LEED, or
Built Green design.
(b) Buildings designed with triple glazed windows.
(c) Buildings designed with exterior shading features on windows to help regulate heat gain and
energy used for cooling. Shading features can be operable or inoperable.
5.2 Defensive Space (CPTED).
(1) Purpose.
To encourage design techniques that reduce the rate of crime associated with persons and
property.
(2) Applicability. The following standards are recommended, not required.
(3) Guidelines. Projects are encouraged to incorporate one or more of the following:
(a) Building entryways should be oriented to be visible from other buildings, apartments, and
houses.
(b) Screening such as landscaping, fences, and screen wall should not block visibility and make two-
way surveillance difficult.
(c) Lighting for trails and bike paths should be provided at an appropriate scale and have
appropriate spacing to avoid creation of dark spots of insufficiently lighted areas.
(d) Over-illumination and glare should be avoided where pedestrians and vehicles meet to minimize
pedestrian vehicle conflicts.
Page 106 of 289
ACC 18.31.200, Architectural and site design review standards and regulations Page 1 of 9
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
18.31.200 Architectural and site design review standards and
regulations.
A. Intent and Purpose. The architectural and site design regulations provide an administrative
review process for evaluating the design and arrangement of development. The architectural
and site design regulations are intended to be consistent with and implement the policies of
the comprehensive plan. The purposes of these design review regulations are to:
1. Foster good decision-making for development through architectural and site design
within the context of the community’s built and natural environmental character, scale and
diversity;
2. Promote the use of appropriate scale of buildings and the configuration of open space
and parking areas for development to safely and comfortably accommodate pedestrian
activities;
3. Coordinate the interrelationship of buildings and public and private open space;
4. Discourage monotony in building design and arrangement, while promoting harmony
among distinct building identities; and
5. Mitigate, through design and site plan measures, the visual impact of large building
facades, particularly those which have high public visibility (encourage the creative use of
architectural and landscape features in order to reduce the actual and perceived scale and
bulk of structures).
B. Applicability. The following land uses, types of development activities, including all related
site improvements, and geographic areas, are subject to the architectural and site design
standards and the processes and regulations for conducting design review contained in this
chapter:
1. Apartment buildings, s (Formerly Multiple-Family) and Mixed-Use Developments, Congregate
living development, and Non-residential development. The following land uses and types of
development are subject to the city’s apartment and mixed-use design standards
document unless addressed by a different set of architectural and site design standards
applicable to a specific geographic area:
Page 107 of 289
ACC 18.31.200, Architectural and site design review standards and regulations Page 2 of 9
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
a. Apartment buildings, containing seven or more units on a single lot, development
inclusive of seven or more units in all zones in the city where permitted outright or as a
conditional useallowed and not otherwise addressed through the city’s residential infill
development standards (Chapter 18.25 ACC); and
b. Mixed-Use Residential Development. Mixed-use development containing residential
living units in all zones in the city where allowed permitted outright or as a conditional
use; and
c. Retirement apartments, congregate living facilities and senior housing complexes in
all zones in the city where permitted outright or as a conditional useallowed; and
d. Non-residential development, except for development within the M-1 and M-2
zones.
2. Downtown Urban Center. The following locations of development activities are subject to
the city’s downtown urban design standards document:
a. Properties located within the boundaries of the DUC, downtown urban center
zoning district boundary, as identified on the comprehensive zoning map.
3. Auburn Junction. The following locations of development activities are subject to the
city’s Auburn Junction design standards document:
a. Properties located within the boundaries of West Main Street, 2nd Street SE/SW, A
Street SE, and A Street SW as identified with ACC 18.29.070, downtown urban design
standards.
4. Northeast Auburn Special Planning Area. The following locations of development activities
are subject to the city’s Auburn Gateway architectural and site design standards document:
a. Properties located within the boundaries of the Auburn Gateway Project as defined
by the development agreement approved by city Resolution No. 4756, or as may be
subsequently amended. The Auburn Gateway architectural and site design is
addressed in Section 4 of that resolution and provided as Attachment 4 to the
resolution.
C. Exemptions. The following activities as determined by the community development director
shall be exempt from the provisions of the design standards:
Page 108 of 289
ACC 18.31.200, Architectural and site design review standards and regulations Page 3 of 9
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
1. Any building activity that does not require a building permit; or
2. Interior construction work which does not alter the exterior of the structure; or
3. Normal or routine building and site maintenance/repair that is exempt from issuance of
a permit, including the repair or maintenance of structural members; or
4. Interior alterations that do not modify an existing site condition.; or
5. Site and exterior alterations that do not exceed 10 percent of the assessed valuation of
the property building or land per the most recent county records; or
6. Building additions that are less than 10 percent of the existing floor area of the existing
building. Any cumulative floor area increase from the adoption date of the ordinance
establishing the architectural and site design standard that totals more than 10 percent
shall not be exempt unless the community development director determines compliance
with these standards would be infeasible and/or unreasonable.
D. Design Standard Documents. Adopted by reference are the following architectural and site
design documents, copies of which shall be maintained by the city clerk. These documents
contain the standards for the design and development of the built environment. The
community development director or designee shall have the authority to apply the standards to
specific development proposals. The following specific architectural and design standards
documents may be amended upon approval by the community development director:
1. Mixed-use and apartment (formerly multiple-family) developmentCitywide design
standards.
2. Auburn Gateway architectural and site design standards.
3. Downtown urban design standards.
4. Auburn Junction design standards.
E. Timing of Administrative Design Review.
1. Design review shall be conducted by the community development director or designee
prior to or concurrent with the processing of building permits and/or review of
discretionary land use approvals/permits.
Page 109 of 289
ACC 18.31.200, Architectural and site design review standards and regulations Page 4 of 9
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
2. The decision on the administrative design review shall be issued prior to issuance of the
building permits and/or issuance of discretionary land use approvals/permits.
F. Pre-Application Meeting Recommendation with– When Required Associated With a Design Review.
A pre-application conference is recommended for all other projects subject to the city’s
architectural and site design review but is not required.
1. A pre-application conference is requiredstrongly recommended for the following
instances:
a. For aApartments in the R-3 and R-4 residential zonesbuildings; and
b. For mMixed-use development; and containing residential living units located within
R-3 and R-4 residential zones; and
c. For mixed-use development containing residential living units located within
commercial zones; and
cd. For retirement apartments, congregate living facilities and senior housing
complexes. located within R-3 and R-4 residential zones, and all commercial zones.
2. A pre-application conference is strongly recommended for all other projects subject to
the city’s architectural and site design review but is not required.
G. Design Review Submittal Requirements. In addition to any other documentation required for
submittal of a complete application for building permit or discretionary land use
approvals/permits, the following items shall be required for the architectural and site design
review:
1. Elevation drawings prepared by an architect licensed in the state of Washington of all
proposed construction, including dimensional drawings at one-eighth inch equals one foot
or comparable scale showing the type of exterior materials, color (where applicable),
exterior finishes for buildings and accessory structures, location and elevations of exterior
lighting for buildings, the type, style and model of exterior lighting fixtures (where
applicable), parking areas, and fenestration details;
2. A to-scale landscape plan prepared by a landscape architect licensed in the state of
Washington showing existing vegetation to be retained and proposed vegetation to be
Page 110 of 289
ACC 18.31.200, Architectural and site design review standards and regulations Page 5 of 9
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
installed inclusive of the common and botanical name of all vegetation, the location and
quantity of vegetation, the initial planting size and methods of irrigation;
3. A context vicinity map that shows all structures on the property and within 200 feet in
each direction of the subject property drawn approximately to scale;
4. A neighborhood circulation plan consistent with the provisions of Chapter 17.16 ACC
(Neighborhood Circulation Plan); and
5. Conceptual plans for any public infrastructure, including roads, water, sewer, and storm
facilities.
H. Interpretations.
1. The community development director shall be authorized to interpret the meaning of
words, phrases and sentences which relate to the implementation of the specific
architectural and design standards document. Any interpretations regarding
implementation of the specific architectural and design standards document shall be made
in accordance with its intent or purpose statements and the intent and purpose statements
of this chapter. For interpretations, life safety and public health regulations shall be given
priority over all other regulations.
2. Administrative interpretations may be appealed to the hearing examiner as prescribed
in ACC 18.70.050.
I. Design Review DeparturesAdjustments.
1. Authority for Design Review DeparturesAdjustments. The community development director
or designee shall have the authority, subject to the provisions for departures within design
standard documentsof this section and upon such conditions as the community
development director or designee may deem necessary to comply with the provisions of
this section, to approve design departures or alternative design treatments. adjustments as
follows:
a. An adjustment to architectural or site design requirements such that no more than
two of the total number of required menu items in the city of Auburn apartment and
mixed-use design standards are out of compliance.
Page 111 of 289
ACC 18.31.200, Architectural and site design review standards and regulations Page 6 of 9
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
b. An adjustment to required building wall and roof modulation standards, as
contained in the city of Auburn apartment and mixed-use design standards, up to 20
percent of the amount of any quantified standards contained therein.
c. An adjustment to the architectural or site design requirements that remains
consistent with the purpose and intent of the architectural and site design standards.
2. Required Findings to Grant Design Review DeparturesAdjustments. Each determination
granting a departurean adjustment by the community development director or designee
shall be supported by written findings showing specifically wherein all of the following
conditions exist:
a. That the granting of such departure adjustment meets the purpose of the
standards and any other applicable departure criteria that applies to the specific
standarddoes not constitute a grant of special privilege inconsistent with the
limitations upon uses of other properties in the vicinity and/or zone of the subject site;
and
b. That the granting of such departure adjustment will not adversely affect the
established character of the surrounding neighborhood, discourage maintenance or
upgrades on surrounding properties nor result in perpetuation of those design
qualities and conditions which the comprehensive plan intends to eliminate or avoid ;
and
c. That the project incorporates alternate design characteristics that are equivalent or
superior to those otherwise achieved by strict adherence to the standard. stated menu
options; and
3. Public Notification and Action on Design Review Adjustment Applications. Upon the filing of
a properly completed application and associated request for a design review adjustment,
the community development director or designee shall comply with the city’s Type II land
use review requirements for issuance of a properly noticed and appealable land use
decision.
34. Appeal of Director’s Decision on Design Review Departures. Adjustment
a. If a written objection to the initial determination notice is filed within 14 business
days of said notification, the community development director or designee shall
Page 112 of 289
ACC 18.31.200, Architectural and site design review standards and regulations Page 7 of 9
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
reconsider the initial determination in light of the objection(s) as raised and render a
final decision on the permit. This final decision shall result in either the community
development director’s affirmation of the original determination of approval, the
approval with additional modifications or denial.
b. Upon completion of the community development director’s reconsideration, all
parties notified of the original determination shall receive notification of the
community development director’s final decision. Any party aggrieved by the
community development director’s final decision may file an appeal of that decision to
the hearing examiner in accordance with the city’s land use appeal provisions. Such
appeals for hearing examiner review must be filed within 14 business days from the
date the written decision was made and shall include the following:
i. The appeal shall be filed on forms provided by the department of planning and
development.
ii. The appeal shall clearly state the decision being appealed, setting forth the
specific reason, rationale, and/or basis for the appeal.
iii. Fees associated with the appeal shall be paid to the city upon filing of the
appeal in accordance with a fee schedule established by resolution.
5. Upon filing of a timely and complete appeal, the hearing examiner shall conduct a
public hearing to consider the merits of the appeal. This hearing shall be subject to the
city’s public noticing and public hearing requirements and shall include notification of all
parties notified of the community development director’s final decision. The hearing
examiner may affirm the community development director’s decision or may remand the
matter to the community development director for further review in accord with the
examiner’s direction.
6. If no written objection is filed to the initial determination within the specified time limits,
the community development director shall render a final decision on the permit in accord
with the initial determination.
J. Approval Criteria for Design Review. The community development director or designee may
approve, modify and approve, or deny an application for an administrative design review. Each
Page 113 of 289
ACC 18.31.200, Architectural and site design review standards and regulations Page 8 of 9
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
determination granting approval or approval with modifications shall be supported by written
findings showing the applicant satisfies all the following criteria:
1. The plans and supplemental materials submitted to support the plan meet the
requirements of the specific architectural and site design documents; and
2. The proposed development is consistent with the comprehensive plan.
3. The proposed development meets required setback, landscaping, architectural style
and materials, such that the building walls have sufficient visual variety to mitigate the
appearance of large facades, particularly from public rights-of-way, single-unit detached
dwellings and middle housing.
4. In addition to the criteria in subsections (J)(1) through (J)(3) of this section, for
apartments and retirement apartment projects, the director or designee must determine
that the following key review criteria have been met:
a. The proposed development is arranged in a manner that either:
i. Provides a courtyard space creating a cohesive identity for the building cluster
and public open space furnished to facilitate its use; or
ii. Possesses a traditional streetscape orientation that provides clearly identifiable
and visible entries from the street, views from residential units onto the street and
reinforces pedestrian-oriented streetscape characteristics (e.g., building edge
abutting sidewalk, entries onto the street); or
iii. Faces and facilitates views of a major open space system;
b. The proposed development provides a variety in architectural massing and
articulation to reduce the apparent size of the buildings and to distinguish vertical and
horizontal dimensions;
c. The proposed development contains a combination of elements such as
architectural forms, massing, assortment of materials, colors, and color bands
sufficient to distinguish distinct portions and stories of the building;
Page 114 of 289
ACC 18.31.200, Architectural and site design review standards and regulations Page 9 of 9
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
d. Residential buildings in large apartment projects or mixed-use projects are
physically integrated into the complex possessing sufficiently different appearance or
placement to be able to distinguish one building from another;
e. Unit entrances are individualized by use of design features that make each
entrance distinct or which facilitate additional personalization by residents;
f. Areas dedicated to parking are sufficiently visually broken up and contain a
complement of vegetative materials to project a landscaped appearance;
g. Where applicable, a transition is created that minimizes impacts from apartments
and mixed-use development projects on neighboring lower density residential dwelling
units; and
h. Where applicable, in cases of granting density or height bonuses, the project has
provided community benefits, facilities or improvements above and beyond those
required in the municipal code and supports the goals, objectives and policies of the
comprehensive plan. (Ord. 6959 § 1 (Exh. A), 2024; Ord. 6728 § 4 (Exh. D), 2019; Ord. 6408 § 1,
2012; Ord. 6287 § 2, 2010; Ord. 6245 § 15, 2009.)
Page 115 of 289
ACC 18.23.040, Development standards Page 1 of 4
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
18.23.040 Development standards.
A. Hereafter, no use shall be conducted and no building, structure and appurtenance shall be
erected, relocated, remodeled, reconstructed, altered or enlarged unless in compliance with the
requirements in Tables 18.23.040A (C-1, C-2, and C-AG Zone Development Standards) and
18.23.040B (M-1 and M-2 Zone Development Standards) and in compliance with the provisions
of this title, and then only after securing all permits and approvals required hereby. These
standards may be modified through either an administrative variance or variance, subject to
the procedures of Chapter 18.70 ACC.
Table 18.23.040A. C-1, C-2 and C-AG Zone Development Standards
Development Standard
Requirement by Zone
C-1
Light Commercial
C-2
Heavy Commercial
C-AG
Mixed-Use
Commercial
Minimum lot area None None None1
Minimum lot width, depth None None None
Maximum lot coverage None None None
Minimum setbacks Minimum setbacks required for structures. See also ACC 18.31.070 for
specific exceptions to these setback standards.
Front 20 ftNone4 20 ftNone4 20 ft
Side, Interior None2 None2 None2
Side, Street 15 ft 15 ft 15 ft
Rear None2 None2 None2
Height limit Maximum allowable height of structures. See also ACC 18.31.030
Page 116 of 289
ACC 18.23.040, Development standards Page 2 of 4
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Development Standard
Requirement by Zone
C-1
Light Commercial
C-2
Heavy Commercial
C-AG
Mixed-Use
Commercial
(Height limitations – Exceptions) for specific height limit exceptions.
Maximum height 45 ft3 75 ft 75 ft
Additional development standards None None None
Fences and hedges See Chapter 18.31 ACC
Landscaping See Chapter 18.50 ACC
Parking See Chapter 18.52 ACC
Signs See Chapter 18.56 ACC
Lighting See Chapter 18.55 ACC
Nonconforming structures, land and
uses
See Chapter 18.54 ACC
Notes:
1 Residential uses: no minimum lot size; provided, that residential density does not exceed 20 units per gross
acre (this includes privately owned open space tracts but excludes dedicated public roads).
2 A 25-foot setback is required when adjacent to a residential zone.
3 Buildings within the Auburn north business area, as established by Resolution No. 2283, may exceed 45 feet
if one additional foot of setback is provided from each property line (or required minimum setback) for each
foot the building exceeds 45 feet in height.
4 In addition to meeting setback requirements, all structures must meet sight distance requirements in
accordance with city engineering design and construction standards.
Page 117 of 289
ACC 18.23.040, Development standards Page 3 of 4
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Table 18.23.040B. M-1 and M-2 Zone Development Standards
Development Standard
Requirement by Zone
M-1
Light Industrial
M-2
Heavy Industrial
Minimum lot area None None
Minimum lot width, depth None None
Maximum lot coverage None None
Minimum setbacks Minimum setbacks required for structures. See also ACC 18.31.070 for
specific exceptions to these standards.
Front 20 ftNone 30 ft
Side, Interior None1 None1
Side, Corner 20 ft 30 ft
Rear None1 None1
Height limit Maximum allowable height of structures. See also ACC 18.31.030 (Height
limitations – Exceptions) for specific height limit exceptions
Maximum height 45 ft2 45 ft2
Additional development standards None None
Page 118 of 289
ACC 18.23.040, Development standards Page 4 of 4
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Development Standard
Requirement by Zone
M-1
Light Industrial
M-2
Heavy Industrial
Fences and hedges See Chapter 18.31 ACC
Landscaping See Chapter 18.50 ACC
Parking See Chapter 18.52 ACC
Signs See Chapter 18.56 ACC
Lighting See Chapter 18.55 ACC
Nonconforming structures, land and
uses
See Chapter 18.54 ACC
Notes:
1 A 25-foot setback is required when adjacent to a residential zone.
2 Buildings may exceed 45 feet if one foot of setback is provided from each property line (or required
minimum setback) for each foot the building exceeds 45 feet.
(Ord. 6959 § 1 (Exh. A), 2024; Ord. 6885 § 1 (Exh. A), 2022; Ord. 6728 § 3 (Exh. C), 2019; Ord. 6433 § 26, 2012.)
Page 119 of 289
ACC 18.07.030, Development standards Page 1 of 4
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
18.07.030 Development standards.
Table 18.07.030. Residential Development Standards
Standard RC R-1 R-2 R-3 R-4 R-NM R-F
A Minimum density units
or lots per acre (lot area
per unit)1, 5
0.25
(174,000
sf of lot
area per
unit)
1 (43,500
sf of lot
area per
unit)
7 (6,222
sf lot area
per unit)
12 (3,630
sf lot area
per unit)
16 (2,723
sf lot area
per unit)
30 (1,452
sf lot area
per unit)
7 (6,222
sf lot area
per unit)
B Minimum lot size
(square feet)8
174,000 43,500 4,400 2,700 2,200 2,200 4,400
C Minimum lot width
(feet)2, 5, 7
125 125 40 20 for
interior
lots; 35
for
exterior
lots
20 for
interior
lots; 35
for
exterior
lots
20 for
interior
lots; 35
for
exterior
lots
40
D Units allowed
1 Base units allowed per
lot 6
4 4 4 4 4 4 4
2 Base units per lot
allowed with transit or
affordability bonus 6
6 6 6 6 6 6 6
3 Lot area per unit above
base (B1 or B2 as
applicable) allowance
(square feet) 6
X X 1,250 750 N/A N/A 1,250
4 Maximum units per lot 6 6 6 6 20 N/A N/A 6
Page 120 of 289
ACC 18.07.030, Development standards Page 2 of 4
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Standard RC R-1 R-2 R-3 R-4 R-NM R-F
E Minimum setbacks
(feet)2, 3, 10
1 Residence front
setback3
35 35 10 109 10None 10None 109
2 Garage (minimum front
setback required from
street access)3
20 20 20 20 20 20 20 unless
alley-
loaded
then 15
provided
there are
20 feet
from any
garage
3 Setback to any property
line for barns, stables,
or similar structures for
enclosure of large
domestic animals
For other animals, see
the supplemental
development standards
for animals in ACC
18.31.220
75 X X X X X X
4 Setback to any property
line for any corral,
exercise yard, or arena
for large domestic
animals
For other animals, see
the supplemental
development standards
for animals in ACC
35 X X X X X X
Page 121 of 289
ACC 18.07.030, Development standards Page 3 of 4
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Standard RC R-1 R-2 R-3 R-4 R-NM R-F
18.31.220
5 Interior side setback 20 10 5 5 5 5 5
6 Street side setback3
In all zones, 20 feet
minimum street side
setback required from
street access.
35 20 10 10 10 10 10
7 Rear setback3 35 20 15 15 10 10 15
8 Rear setback, detached
structure3, 8
In all zones, 20 feet
minimum street side
setback required from
street access.
15 15 10 5 5 5 10
F Maximum impervious
area (%)
25 50 75 80 90 90 75
G Maximum building
height (feet)
35 35 35 45 75 75 45
H Maximum height of
accessory buildings and
structures
354 35 24 24 24 24 24
I Minimum front setback
area landscape strip
(feet)
N/A N/A N/A 5 10 10 N/A
J Minimum side setback
area landscape strip
N/A N/A N/A 5 10 10 N/A
Page 122 of 289
ACC 18.07.030, Development standards Page 4 of 4
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Standard RC R-1 R-2 R-3 R-4 R-NM R-F
(feet)
K Minimum landscaped
open space (%)
N/A N/A See
Chapter
18.50 ACC
See
Chapter
18.50 ACC
See
Chapter
18.50 ACC
See
Chapter
18.50 ACC
N/A
1 See Chapter 18.32 ACC for calculating density.
2 All minimum lot widths, setbacks, and landscaping strips are subject to demonstration to the satisfaction of
the city engineer that all required utility infrastructure, access requirements, and street elements can be
accommodated in accordance with the city engineering design standards and construction standards.
3 In addition to meeting setback requirements, all structures must meet sight distance requirements in
accordance with city engineering design and construction standards.
4 Barns and other specialized structures used for agricultural purposes may exceed the height limits.
5 Provision applicable to residential subdivision.
6 See ACC 18.02.067 for calculating units allowed per lot.
7 Applies to new parent lots within a unit lot subdivision.
8 When abutting an alley, detached accessory dwelling units are allowed within the rear setback.
9 Non-residential, mixed use, and apartment buildings may have either no or a reduced front setback if the
applicable Citywide “Storefront” design standards are met.
10 Minimum setbacks required for structures. See also ACC 18.31.070 for specific exceptions to these setback
standards.
(Ord. 6959 § 1 (Exh. A), 2024; Ord. 6661 § 3, 2018; Ord. 6600 § 10, 2016; Ord. 6245 § 5, 2009.)
Page 123 of 289
AGENDA BILL APPROVAL FORM
Agenda Subject: Meeting Date:
Downtown Design Standards Update and Associated Zoning Code
Update
Staff Introduction/Presentation (Tatro)
Staff will present the proposed updates to the Downtown Design Standards
and amended code to Planning Commission for a recommendation to City
Council.
May 5, 2026
Department: Attachments: Budget Impact:
Community Development Staff Report , Exhibit 1
PowerPoint Presentation, Exhibit
2 Chapter 18.29 ACC Text
Amendment, Exhibit 3 Downtown
Design Standards, Exhibit 4 DUC
Zoning Districts Map, Exhibit 5
ACC 18.02.070 Text Amendment
Administrative Recommendation:
Planning Commission to deliberate and take action to recommend to City Council approval of the
updated Downtown Urban Center Design Standards and amendments to Chapter 18.29 ACC.
Background for Motion:
Background Summary:
See attached Staff Report
Councilmember: Staff: Jason Krum
Page 124 of 289
PLANNING COMMISSION STAFF REPORT
AGENDA SUBJECT/TITLE:
Downtown Design Standards Update and Downtown Urban Center Zoning Code Update
CITY FILE NO(s).:
City File No. ZOA26-0003
APPLICANT/AGENT/OWNERS:
City of Auburn
REQUEST:
Planning Commission to hold a public hearing, deliberate, and take action on the updated Downtown
Urban Center Design Standards and associated zoning code amendments to Chapter 18.29 Auburn City
Code (ACC) to implement the Downtown Subarea Plan and comply with HB 1293.
LOCATION:
Downtown Urban Center
NOTIFICATION:
A Notice of Public Hearing (NOH) was issued on April 13, 2026.
HEARING DATE:
May 5, 2026
SEPA STATUS:
A Notice of Adoption of an Existing Final Environmental Impact Statement (FEIS) was issued on March 12,
2026 (SEP26-0004). The City has adopted the Downtown Subarea Plan Planned Action FEIS to satisfy
SEPA requirements for this non-project action.
STAFF:
Alyssa Tatro, Senior Planner, Dept. of Community Development
STAFF RECOMMENDATION:
Planning Commission to deliberate and take action to recommend to City Council approval of the updated
Downtown Urban Center Design Standards and amendments to Chapter 18.29 ACC.
SUMMARY OF UPDATES
Downtown Design Standards
At a high level, the proposed Downtown Design Standards update:
• Implements the goals and policies of Auburn’s Downtown Subarea Plan related to economic
vitality, walkability, placemaking, and community identity;
Page 125 of 289
Staff Member: Tatro Date: March 23, 2026
Page 2 of 6
• Replaces discretionary, guideline-based provisions with clear, measurable, and objective
standards in compliance with HB 1293;
• Prioritizes pedestrian-oriented design;
• Improves predictability and transparency in the development review process while maintaining
the character of downtown; and
• Allows flexibility through departures, rather than subjective discretion.
The existing Downtown Design Standards rely on intent-based guidelines and qualitative evaluation.
Compliance with the design standards is often determined by whether a proposal meets the intent of a
guideline, which requires staff judgment and interpretation. The proposed standards instead rely on
objective criteria such as minimum and maximum dimensions, percentages, and clearly defined
requirements. This allows projects to be evaluated based on measurable outcomes rather than subjective
interpretation, which will improve consistency and predictability in the application of the standards.
1. Block-Frontage-Based Framework:
The proposed update replaces the Pedestrian I and Pedestrian II Street classification system with a block-
frontage-based framework. Frontage types such as Storefront, Mixed, and Landscaped are assigned to
streets and blocks and are paired with standards for building placement, ground-floor design,
transparency, weather protection, and parking location.
2. Emphasis on Pedestrian Experience and Economic Vitality:
The proposed standards strengthen requirements for active ground floors, prominent building entrances,
transparency, and weather protection along key streets. These standards are intended to encourage
walking, increase foot traffic to businesses, and create streets that are comfortable and engaging year-
round.
3. Ground-Floor Residential Design Standards:
The proposed update introduces clearer standards for ground-floor residential units, including setbacks,
elevation, and the transition between public sidewalks and private space. These standards are designed
to protect resident privacy while maintaining active and visually interesting streetscapes.
4. Flexibility Through Departures:
Rather than relying on subjective judgement, the proposed standards identify specific provisions that may
be modified through a departure process. Departures are limited in scope and must demonstrate how the
alternative design meets the stated purpose of the standard. This approach allows flexibility while
maintaining transparency and consistency.
Page 126 of 289
Staff Member: Tatro Date: March 23, 2026
Page 3 of 6
Chapter 18.29 – Downtown Urban Center Zoning Code Update
At a high level, the proposed Downtown Urban Center zoning code update:
• Aligns zoning districts and development standards with the recently adopted Downtown Plan;
• Updates use regulations to better reflect intended land use patterns within each district;
• Revises parking standards to reduce minimum requirements;
• Clarifies applicability;
• Adds a new Planned Action Standards section to implement the Downtown Subarea Planned
Action Environmental Impact Statement (EIS); and
• Includes overall changes to ensure clarity and consistency with state law.
1. Expanded and Refined Implementing Districts:
The Downtown Urban Center remains a land use designation, and the proposed revisions refine
implementing district structure. These districts are more clearly defined with specific purposes and
development expectations. Each district now includes clearer intent language and specific density and
height limits, helping align zoning with the Downtown Plan’s land use framework.
2. Updated Use Regulations by District:
The existing code generally prohibits a list of uses across the entire Downtown Urban Center. The
proposed code reorganizes use limitations so that prohibited uses are identified by district rather than
applied uniformly. The update also adds a new section for uses requiring a Conditional Use Permit.
3. Revisions to Parking Standards:
The proposed code significantly updates parking requirements across the Downtown Urban Center.
Changes include:
• Reducing or eliminating minimum parking requirements for several residential uses;
• Establishing no minimum parking requirements for affordable housing, senior housing, and small
commercial uses; and
• Eliminating parking requirements for ground-floor nonresidential uses in mixed-use buildings.
4. District Development Standards:
The proposed code reorganizes development standards so that they are clearly applied by district. For
example:
• Core districts continue to use the FAR-based system with bonuses;
• The Neighborhood Residential district includes minimum density, lot size, and setback standards
Page 127 of 289
Staff Member: Tatro Date: March 23, 2026
Page 4 of 6
tailored to middle housing; and
• Commercial and industrial districts include standards that address compatibility with adjacent
residential areas.
5. Addition of Planned Action Standards:
The proposed code adds a new section establishing Planned Action Standards for the Downtown Urban
Center. This text is taken directly from the Planned Action Ord. (No. 7006) adopted by Council on
December 15, 2025. The purpose of adding the text in code is for ease of access for staff and the public.
This section implements the Downtown Subarea Planned Action EIS and allows qualifying projects to rely
on the existing environmental review rather than completing separate SEPA reviews.
6. Minor Text and Process Updates:
These changes are primarily administrative and intended to improve clarity and consistency. Additional
updates include updating references and cross-references, minor adjustments to exemption language
and bonus features section, and inclusion of existing sign regulations from the Design Standards into code
for ease of access.
FINDINGS OF FACT:
Background Summary:
1. In December 2025, the City of Auburn adopted the Downtown Subarea Plan, which establishes a
long-term vision and land use framework for the Downtown Urban Center, including anticipated
growth, development patterns, and urban design expectations.
2. The Downtown Urban Center Design Standards and Chapter 18.29 ACC zoning regulations
function as the primary implementation tools for achieving the goals and policy direction
established in the Downtown Subarea Plan.
3. The existing Downtown Design Standards were originally adopted in 2007 and most recently
amended in 2021 and rely in part on discretionary, guideline-based provisions.
4. House Bill 1293 requires cities planning under the Growth Management Act to adopt clear and
objective design standards and limit reliance on subjective design review.
5. The proposed Downtown Design Standards update establishes a more objective and predictable
regulatory framework, including a block-frontage-based system that organizes standards based
on street context and frontage type.
6. The updated standards include defined applicability thresholds that determine when and how
standards apply to new development, additions, and site modifications, ensuring that
requirements are proportional to the scale of development.
Page 128 of 289
Staff Member: Tatro Date: March 23, 2026
Page 5 of 6
7. The proposed standards include a structured departures process that allows flexibility from
specific standards when alternative designs meet the intent of the standards, while maintaining
overall design quality and consistency.
8. The proposed amendments to Chapter 18.29 ACC align zoning regulations with the Downtown
Subarea Plan by refining implementing districts and establishing a district-based structure for use
regulations and development standards.
9. The updated zoning framework differentiates development standards by district, reflecting varying
intensities of development across the Downtown Urban Center. The standards will preserve and
protect the public health, safety, and welfare of the citizens of Auburn and support a more
walkable, mixed-use, and transit-oriented downtown environment.
10. In accordance with ACC 14.03.060 Legislative nonproject decisions made by the city council
under its authority to establish policies and regulations are not classified as a “type” of project
permit decision. Legislative nonproject decisions include, but ar e not limited to, amendments to
the text and map of the comprehensive plan or development regulations.
11. Per ACC 18.68.030(B) a “Zoning Text Amendment” is an application to change the text of ACC
Title 18. This type of application or initiation shall be processed as a legislative nonproject
decision, consistent with ACC 14.03.060. Public notice shall be provided consistently with ACC
Title 14.
12. Revised Code of Washington (RCW) 42.21C.135 Gives authority of local governmental units to
adopt rules, guidelines and model ordinances by reference.
13. The design standards update and text amendment were introduced and discussed with the
Planning Commission previously at the February 3, 2026, meeting and the March 3, 2026,
meeting. Staff provided memorandums and presentations.
14. A public Open House was held on February 11, 2026, at City Council Chambers and
approximately 20 attendees were present.
15. An email from Auburn Communications was sent on February 7, 2026, to a list of architects in the
region inviting them to review the new design standards located on the City’s public notices
website.
Procedural Steps:
1. The proposed updates to the existing Downtown Design Standards and text amendment (zoning
code update) have been discussed with the Planning Commission previously at regular meetings
on February 3, 2026, and March 3, 2026.
2. Pursuant to RCW 36.70A, the text amendment was transmitted to the Washington State
Department of Commerce on December 31, 2025. The 60-day notice period ended on March 1,
2026.
Page 129 of 289
Staff Member: Tatro Date: March 23, 2026
Page 6 of 6
3. A Notice of Adoption of an existing FEIS was issued on March 12, 2026.
4. A Notice of Public Hearing (NOH) was issued on April 13, 2026. Pursuant to Chapter 18.68 ACC,
the following methods of noticing for the Planning Commission public hearing were conducted:
a. The NOH was published in the Seattle Times on April 13, 2026.
b. The NOH was posted in three public locations (City Hall, City Annex, and the City’s Public
Land Use Notice webpage).
c. The NOH was mailed to property owners in the Downtown Urban Center by April 25, 2026.
EXHIBITS:
1. Downtown Design Standards and Code Presentation
2. Chapter 18.29 ACC Text Amendment
3. Downtown Design Standards
4. DUC Zoning Districts Map
5. ACC 18.02.070 Text Amendment
Page 130 of 289
AUBURN
VALUES
S E R V I C E
ENVIRONMENT
E C O N O M Y
C H A R A C T E R
SUSTAINABILITY
W E L L N E S S
C E L E B R AT I O N
PLANNING COMMISSION – PUBLIC
HEARING
DOWNTOWN DESIGN
STANDARDS AND CODE
UPDATE
PRESENTED BY
ALYSSA TATRO, SENIOR PLANNER
MAY 5, 2026
Department of Community Development
Planning Building Development Engineering Permit Center
Economic Development Code Enforcement
Page 131 of 289
SERVICE
ENVIRONMENT
ECONOMY
CHARACTER
SUSTAINABILITY
WELLNESS
CELEBRATION
BACKGROUND
AND PURPOSE
Page 132 of 289
DOWNTOWN DESIGN STANDARDS AND CODE
Downtown
Subarea Plan
Downtown Downtown
Design
Standards
Chapter 18.29 Chapter 18.29
ACC – Text
Amendment
Page 133 of 289
SERVICE
ENVIRONMENT
ECONOMY
CHARACTER
SUSTAINABILITY
WELLNESS
CELEBRATION
GOALS OF
UPDATE
IMPLEMENT DOWNTOWN
SUBAREA PLAN
COMPLIANCE WITH HB
1293
Page 134 of 289
PROCEDURAL STEPS
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Presentation on Feb 3, 2026, and March 3, 2026,
Planning Commission Meeting
Text Amendment sent to the Department of
Commerce on Dec 31, 2025. No comments
received
Notice of Public Hearing issued March 24, 2026
Page 135 of 289
SERVICE
ENVIRONMENT
ECONOMY
CHARACTER
SUSTAINABILITY
WELLNESS
CELEBRATION
PUBLIC
OUTREACH
Page 136 of 289
SERVICE
ENVIRONMENT
ECONOMY
CHARACTER
SUSTAINABILITY
WELLNESS
CELEBRATION
OVERVIEW OF
CHANGES
Replace discretionary guidelines with objective
standards
Improve predictability and transparency
Strengthen pedestrian-oriented design
Refine zoning districts and use regulations
Reduce or eliminate certain parking requirements
And add a Planned Action framework for
environmental review
Page 137 of 289
DOWNTOWN DESIGN STANDARDS
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Page 138 of 289
BLOCK-
FRONTAGE
STANDARDS:
Page 139 of 289
STOREFRONT BLOCK-FRONTAGE
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Page 140 of 289
LANDSCAPED
BLOCK-
FRONTAGE
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Page 141 of 289
TRANSPARENCY
STANDARDS
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Page 142 of 289
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Support multimodal transit
Support local businesses
Pedestrian friendly environment
Page 143 of 289
APPLICABILITY
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Level 1
Improvements
Level 2
Improvements
Level 3
Improvements
Page 144 of 289
DEPARTURES
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Page 145 of 289
CHAPTER 18.29 ACC – TEXT AMENDMENT
Page 146 of 289
CHAPTER 18.29 ACC – OVERVIEW OF CHANGES
Refine the
implementing
districts of the
DUC
Clarify permitted
and prohibited
uses by district.
Refine
development
standards
Add a Planned
Action section to
align with the
Downtown
Subarea EIS.
Improve
organization,
consistency, and
clarity within the
chapter.
Page 147 of 289
DOWNTOWN
URBAN CENTER
ZONING MAP
Page 148 of 289
DUC CORE 125 AND DUC CORE 75
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Page 149 of 289
DUC NEIGHBORHOOD RESIDENTIAL (N-R)
Page 150 of 289
DUC HEALTH & WELLNESS (H-W)
Page 151 of 289
DUC COMMERCIAL AND INDUSTRIAL ZONES
DUC M-1 – Light
Industrial
DUC C-1 – Light
Commercial
DUC C-2 – Heavy
Commercial
Page 152 of 289
DUC FLEX RESIDENTIAL (F-R)
Page 153 of 289
IMPACT OF CHANGES
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Improves clarity and predictability in design review
Ensures compliance with HB 1293
Alignment with the vision of the Downtown
Subarea Plan
Page 154 of 289
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
REQUEST
Planning Commission to deliberate and recommend that
City Council approve the updated Downtown Design
Standards and associated amendments to Title 18 to
comply with HB 1293 state requirements.
Page 155 of 289
AUBURN
VALUES
S E R V I C E
ENVIRONMENT
E C O N O M Y
C H A R A C T E R
SUSTAINABILITY
W E L L N E S S
C E L E B R AT I O N
Department of Community Development
Planning Building Development Engineering Permit Center
Economic Development Code Enforcement
Thank you,
Questions?
Page 156 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 1 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Chapter 18.29
DUC DOWNTOWN URBAN CENTER DISTRICT
Sections:
18.29.010 Intent.
18.29.020 Scope.
18.29.030 Process.
18.29.040 Definitions.
18.29.050 Use limitations.
18.29.053 Uses/activities requiring an administrative use permit.
18.29.054 Uses/activities requiring a conditional use permit.
18.29.055 Deviation from development standards.
18.29.04557 Implementing districts.
18.29.060 Development standards.
18.29.070 Design standards.
18.29.080 Planned action standards.
18.29.010 Intent.
The downtown urban center zone is intended to create a distinct and strong identity for
downtown Auburn by establishing land use and design standards for review of development
proposals within the core area of the city of Auburn’s designated urban center, in order to
implement the city of Auburn downtown plan and the goals, policies and objectives of the
Auburn comprehensive plan. The downtown urban centeris zone is intended to produce a
concentration and mixture of commercial, office, medical, retail, residential and civic uses
within the downtown area; to encourage private and public investment, attract shoppers and
visitors, and appeal to existing and new residents; to provide a development pattern that
supports pedestrian movement, bicycles and use of public transit; and to provide opportunities
to increase the city’s tax base, thereby helping to fund public improvements and public services.
(Ord. 6071 § 6 (Exh. A), 2007.)
Page 157 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 2 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
18.29.020 Scope.
A. AThe downtown urban center district zone may be applied to any property designated as
“Downtown” on the Auburn comprehensive plan map.
B. Site plan and building design review and approval shall be required for all public and private
development activities requiring permits within athe downtown urban center districtzone
unless exempted under subsection C of this section. The planning and development director is
given the authority to require building design and site plans consistent with the design
standards contained or referenced herein and to require revisions as necessary in order to
ensure development is consistent with the purpose of this chapter.
C. The following activities, as determined by the director, shall be exempt from the provisions
of this chapter if the property has frontage on a pedestrian street as deflned in the downtown
urban center design standards:
1. Interior alterations that do not alter the exterior appearance of a structure or modify an
existing site condition;
2. Normal or routine building and site maintenance/repair that is exempt from permit
requirements; and
3. Any remodeling or expansion of existing single-unit detached residences and middle
housing developments. with no change in use or addition of dwelling units involved.
D. The following activities, as determined by the director, shall be exempt from the provisions
of this chapter if the property does not have frontage on a pedestrian street as deflned in the
downtown urban center design standards:
1. Interior alterations that do not alter the exterior appearance of a structure or modify an
existing site condition;
2. Site and exterior alterations that do not exceed 10 percent of the assessed valuation of
the property (building or land) per the most recent county records;
3. Building additions that are less than 10 percent of the existing fioor area of the existing
building(s). Any cumulative fioor area increase (from the adoption date of the ordinance
codifled in this chapter) that totals more than 10 percent shall not be exempt; unless the
Page 158 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 3 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
director determines compliance with these standards would be unfeasible and/or
unreasonable;
4. Normal or routine building and site maintenance/repair that is exempt from permit
requirements;
5. Any remodeling or expansion of existing single-unit detached residences with no
change in use or addition of dwelling units involved. (Ord. 6959 § 1 (Exh. A), 2024; Ord. 6287 § 2,
2010; Ord. 6230 § 1, 2009; Ord. 6071 § 6 (Exh. A), 2007.)
18.29.030 Process.
A. Compliance with all development and design standards contained or referenced herein
shall occur in conjunction with any required permit process. The director shall provide
appropriate forms that shall accompany a permit application. The director may approve,
approve with conditions, or deny a building or site development permit application to ensure
compliance with these standards. Any decision regarding a permit application shall be set forth
in writing and contain flndings of fact and conclusions that support the decision made.
B. The decision of the director shall be flnal unless the applicant or any affected party appeals
the decision to the hearing examiner. All appeals shall be in accordance with ACC 18.70.050(B)
through (E). (Ord. 6071 § 6 (Exh. A), 2007.)
18.29.040 Definitions.
These words shall have the following meanings for the purposes of this chapter:
A. “Canopy” means a cover over a sidewalk providing protection from the rain, which is
constructed of durable, permanent materials.
B. “Director” means the director of the Auburn dDepartment of Community planning and
dDevelopment.
Page 159 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 4 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
C. “Green roof” means a roof designed with principles of environmental sustainability,
involving the use of vegetation and storm water collection and cleaning. It may or may not be
accessible.
D. “Health club” means a use that offers exercise and recreational activities for tenants and/or
the general public, either with or without a fee.
E. “Parking, below grade” means any portion of a structure containing parking that is located
below the average flnished grade around a building.
F. “Parking, structured” means parking contained within an enclosed building, designed to
appear like it is part of the larger building complex, or a freestanding structure devoted
exclusively to above-grade parking.
G. “Performing space” means any interior or exterior area designated for live performing and
entertainment.
H. “Public art” means any form of painting, mural, mosaic, sculpture, or other work of art, so
long as it can be appraised as a work of art and its value as such documented, displayed on the
exterior of a building, at or near the pedestrian entrance, or on a public plaza, and visible to
users of the public right-of-way at all times.
I. “Public meeting room” means a space that can be used by the general public and having a
capacity of at least 50 people. It may operate under a reservation or nominal fee system and
must be easily accessible from a lobby or plaza.
J. “Public plaza” means an open space that is visible and accessible to the public at all times,
predominantly open to the sky, and for use principally by people, as opposed to merely a
setting for the building.
K. “Street level retail” means uses providing goods and services, including food and drink,
adjacent to, visible from, and directly accessible from the public sidewalk.
L. “Water feature” means a fountain, cascade, stream, fall, pond of water, or combination
thereof, that serves as a focal point, located outside of a building, publicly visible and accessible,
and active during daylight hours. (Ord. 6287 § 2, 2010; Ord. 6071 § 6 (Exh. A), 2007.)
Page 160 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 5 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
18.29.050 Use limitations.
Hereafter, all buildings, structures or properties may be used for any use, unless speciflcally
prohibited herein. Ground fioor retail, restaurants and/or office use is required for all building
frontages facing Main Street. All uses shall be subject to review and approval by the director.
A. The following uses are prohibited in all DUC zoning districts:
A. Sexually oriented businesses as deflned in Chapter 18.74 ACC.
B. All industrial uses as deflned in the North American Industrial Classiflcation System
(2022 Edition), categories 48 through 49 (transportation), 31 through 33 (manufacturing)
and 42 (wholesale trade).
C. Outdoor storage of materials and equipment (except during active construction
projects).
D. New automobile maintenance and repair businesses.
E. Work release facilities; secure community transition facilities.
F. Wrecking yards.
G. Solid waste transfer stations.
H. Car washes.
I. New gasoline stations.
J. Street-level ministorage.
K. Outdoor sales of vehicles, boats or equipment.
L. Drive-in/drive-through facilities with direct vehicular driveway access onto Main
Street.
M. All marijuana-related businesses and marijuana cooperatives.
N. New single-unit detached dwellings; except for DUC neighborhood residential
district.
1. Battery Energy Storage Systems, Tier III.
2. New motor freight terminals.O. Other uses may be prohibited by the director if the use
is determined to be inconsistent with the intent of this zone or is of the same general
character of the other prohibited uses listed in this section. (Ord. 6959 § 1 (Exh. A), 2024;
Ord. 6642 § 10, 2017; Ord. 6071 § 6 (Exh. A), 2007.)
Page 161 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 6 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
3. Other uses may be prohibited by the director if the use is determined to be inconsistent
with the intent of the downtown urban center or is of the same general character of the
other prohibited uses listed in this section.
4. Solid waste transfer stations.
5. Use as dwelling units of (1) recreational vehicles that are not part of an approved
recreational vehicle park, (2) boats, (3) automobiles, and (4) other vehicles.
6. Work release facilities; secure community transition facilities.
B. The following uses are prohibited in the DUC Core 75, Core 125, and H-W Districts:
1. All industrial uses as defined in the North American Industrial Classification System
(2022 Edition), categories 48 through 49 (transportation), 31 through 33 (manufacturing)
and 42 (wholesale trade), except wine production facility, small craft distillery, small craft
brewery with a tasting room and/or tourism.
2. All marijuana-related businesses and marijuana cooperatives.
3. Car washes.
4. Drive-in/drive-through facilities with direct vehicular driveway access onto Main Street.
5. New automobile maintenance and repair businesses.
6. New fueling stations.
7. New single-unit detached dwellings.
8. Outdoor sales of vehicles, boats or equipment.
9. Outdoor storage of materials and equipment (except during active construction
projects).
10. Sexually oriented businesses as defined in Chapter 18.74 ACC.
11. Street-level ministorage.
12. Wrecking (tow) yards.
C. The following uses are prohibited in the DUC N-R District:
Page 162 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 7 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
1. Agricultural enterprises.
2. All industrial uses as defined in the North American Industrial Classification System
(2022 Edition), categories 48 through 49 (transportation), 31 through 33 (manufacturing)
and 42 (wholesale trade).
3. All marijuana-related businesses and marijuana cooperatives.
4. Apartments (more than 20 units).
5. Café, or coffee shop over 4,000 sf in floor area.
6. Car washes.
7. Civic, social and fraternal clubs.
8. Co-living (more than 80 sleeping units).
9. Commercial over 4,000 sf in floor area.
10. Convenience store over 4,000 sf in floor area.
11. Drive-in/drive-through facilities with direct vehicular driveway access onto Main Street.
12. Group residence facilities (7 or more residents).
13. Hospitals (except animal hospitals).
14. Library, museum.
15. New automobile maintenance and repair businesses.
16. New fueling stations.
17. Outdoor sales of vehicles, boats or equipment.
18. Outdoor storage of materials and equipment (except during active construction
projects).
19. Nursing homes.
20. Sexually oriented businesses as defined in Chapter 18.74 ACC.
21. Street-level ministorage.
Page 163 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 8 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
22. Use as dwelling units of (1) recreational vehicles that are not part of an approved
recreational vehicle park, (2) boats, (3) automobiles, and (4) other vehicles.
23. Wrecking (tow) yards.
D. The following uses are prohibited in the DUC M-1 District:
1. Apartments, standalone.
2. Live/work unit, standalone.
3. Manufacturing, assembling and packaging – Heavy intensity.
4. Marijuana cooperative.
5. New single unit detached dwellings.
6. Nursing home, assisted living facility.
7. Pharmacies.
8. Senior housing, except developments vested prior to Resolution No. 5187.
9. Work/live unit, standalone.
10. Youth community support facility.
E. The following uses are prohibited in the DUC C-1 District:
1. All industrial uses as defined in the North American Industrial Classification System
(2022 Edition), categories 48 through 49 (transportation), 31 through 33 (manufacturing)
and 42 (wholesale trade).
2. All marijuana-related businesses and marijuana cooperatives.
3. Ambulance, taxi, and specialized transportation facility.
4. Apartment units, as part of a mixed-use development.
5. Apartments, standalone.
6. Battery Energy Storage System, Tier II.
7. Building and landscape materials sales.
Page 164 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 9 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
8. Car washes.
9. Commercial recreation facility, outdoor.
10. Construction and heavy equipment sales and rental.
11. Drive-in/drive-through facilities with direct vehicular driveway access onto Main Street.
12. Equipment rental and leasing.
13. Heliport.
14. Kennel, animal boarding.
15. Mobile home, boat, or RV sales
16. Nursery.
17. Outdoor sales of vehicles, boats or equipment.
18. Outdoor storage of materials and equipment (except during active construction
projects).
19. Regional retail establishment.
20. Senior housing, except developments vested prior to Resolution No. 5187.
21. Sexually oriented businesses as defined in Chapter 18.74 ACC.
22. Sports and entertainment assembly facility.
23. Street-level ministorage.
24. Vehicle services – Repair/body work
25. Wrecking (tow) yards.
F. The following uses are prohibited in the DUC C-2 District:
1. All marijuana-related businesses and marijuana cooperatives.
2. Apartments, standalone.
3. Battery Energy Storage System, Tier II.
4. Building contractor, heavy
Page 165 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 10 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
5. Construction and heavy equipment sales and rental
6. Live/work unit, standalone.
7. Manufacturing, assembling and packaging – Heavy intensity.
8. New single unit detached dwellings.
9. Nursing home, assisted living facility.
10. Pharmacies.
11. Senior housing, except developments vested prior to Resolution No. 5187.
12. Warehousing and distribution.
13. Work/live unit, standalone.
14. Wrecking (tow) yards.
15. Youth community support facility.
G. The following uses are prohibited in the DUC F-R District:
1. All marijuana-related businesses and marijuana cooperatives.
2. Apartments, standalone.
3. Battery Energy Storage System, Tier II.
4. Co-living units, more than 80 sleeping units.
5. Live/work unit, standalone.
6. Manufacturing, assembling and packaging – Heavy intensity.
7. Mixed-use, more than 20 units.
8. Nursing home, assisted living facility.
9. Pharmacies.
10. Senior housing, except developments vested prior to Resolution No. 5187.
11. Work/live unit, standalone.
12. Wrecking (tow) yards.
13. Youth community support facility.
Page 166 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 11 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
18.29.053 Uses/activities requiring an administrative use permit.
A. The following uses/activities may be permitted in the DUC Core 75, Core 125, and H-W
Districts when an administrative use permit has been issued pursuant to the provisions
of Chapter 18.64 ACC:
1. Animal daycare businesses that feature outdoor exercise areas and/or kennels.
2. A. Expansions of existing automobile maintenance and repair businesses.;
3. B. Expansions of existing gasoline (fueling) stations.;
1. C. Animal daycare businesses that feature outdoor exercise areas and/or kennels;
1. D. Wine production facility; small craft distillery; small craft brewery; and a tasting
room is an outright allowed use in the DUC zone. (Ord. 6368 § 8, 2011; Ord. 6269 § 32, 2009.)
B. The following uses/activities may be permitted in the DUC N-R District when an
administrative use permit has been issued pursuant to the provisions of Chapter 18.64
ACC:
1. Government facilities.
2. Grocery or specialty food store.
3. Neighborhood recreational buildings and facilities owned and managed by the
neighborhood homeowners’ association.
4. Personal service shop, over 4,000 sf in floor area.
5. Privately owned and operated parks and playgrounds and not homeowners’
association-owned recreational area.
6. Religious institutions, less than one acre lot size. Reference ACC 18.31.165 for
standards related to homeless encampments hosted by a religious organization.
7. Restaurant.
C. The following uses/activities may be permitted in the DUC M-1 District when an
administrative use permit has been issued pursuant to the provisions of Chapter 18.64
ACC:
Page 167 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 12 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
1. Any commercial use abutting a residential zone which has hours of operation
outside of the following: Sunday: 9:00 a.m. to 10:00 p.m. or Monday – Saturday: 7:00
a.m. to 10:00 p.m.
2. Conference/convention facility.
3. Construction and heavy equipment sales and rental.
4. Entertainment, commercial.
5. Government facilities; this excludes offices and related uses that are permitted
outright.
6. Indoor emergency housing or shelter. Reference ACC 18.31.160 for specific
standards.
7. Kennel, animal boarding.
8. Library, museum.
9. Lodging – Hotel or motel.
10. Religious institutions, lot size less than one acre.
11. Religious institutions, lot size more than one acre.
12. Sports and entertainment assembly facility.
13. Supportive housing (permanent). Reference ACC 18.31.160 for specific standards.
14. Transitional housing. Reference ACC 18.31.160 for specific standards.
15. Utility transmission or distribution line or substation.
16. Wrecking (tow) yard.
D. The following uses/activities may be permitted in the DUC C-1 District when an
administrative use permit has been issued pursuant to the provisions of Chapter 18.64
ACC:
1. Animal daycare (excluding kennels and animal boarding).
Page 168 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 13 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
2. Any commercial use abutting a residential zone which has hours of operation
outside of the following: Sunday: 9:00 a.m. to 10:00 p.m. or Monday – Saturday: 7:00
a.m. to 10:00 p.m.
3. Auto parts sales with installation services.
4. Auto/vehicle sales and rental.
5. Automobile washes (automatic, full or self-service).
6. Drive-through espresso stands.
7. Drive-through facility, including banks and restaurants.
8. Entertainment, commercial.
9. Fueling station.
10. Government facilities; this excludes offices and related uses that are permitted
outright.
11. Library, museum.
12. Printing and publishing (of books, newspaper and other printed matter).
13. Private school – Specialized education/training (for profit).
14. Repair service – Equipment, appliances.
15. Utility transmission or distribution line or substation.
E. The following uses/activities may be permitted in the DUC C-2 District when an
administrative use permit has been issued pursuant to the provisions of Chapter 18.64
ACC:
1. Ambulance, taxi, and specialized transportation facility.
2. Any commercial use abutting a residential zone which has hours of operation
outside of the following: Sunday: 9:00 a.m. to 10:00 p.m. or Monday – Saturday: 7:00
a.m. to 10:00 p.m.
3. Commercial recreation facility, outdoor.
Page 169 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 14 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
4. Conference/convention facility.
5. Government facilities; this excludes offices and related uses that are permitted
outright.
6. Kennel, animal boarding.
7. Library, museum.
8. Manufacturing, assembling and packaging – Medium intensity.
9. Senior housing, except developments vested prior to Resolution No. 5187.
10. Sports and entertainment assembly facility.
11. Utility transmission or distribution line or substation.
F. The following uses/activities may be permitted in the DUC F-R District when an
administrative use permit has been issued pursuant to the provisions of Chapter 18.64
ACC:
1. Civic, social and fraternal clubs.
2. Commercial retail establishment, over 4,000 sf in floor area.
3. Government facilities.
4. Grocery or specialty food store, over 4,000 sf in floor area.
5. Religious institutions, less than one acre lot size. Reference ACC 18.31.165 for
standards related to homeless encampments hosted by a religious organization.
1.6. Restaurant, café, or coffee shop, over 4,000 sf in floor area.
18.29.054 Uses/activities requiring a conditional use permit.
A. The following uses/activities may be permitted in the DUC Core 75, Core 125, and H-W
Districts when a conditional use permit has been issued pursuant to the provisions of
Chapter 18.64 ACC:
Page 170 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 15 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
1. Battery Energy Storage System, Tier II.
B. The following uses/activities may be permitted in the DUC N-R District when a
conditional use permit has been issued pursuant to the provisions of Chapter 18.64
ACC:
1. Religious institutions, one acre or larger lot size. Reference ACC 18.31.165 for
standards related to homeless encampments hosted by a religious organization.
2. Transmitting towers.
3. Utility facilities and substations. Excludes all public and private utility facilities
addressed under ACC 18.02.040(E).
C. The following uses/activities may be permitted in the DUC M-1 when a conditional use
permit has been issued pursuant to the provisions of Chapter 18.64 ACC:
1. Heliport.
2. All marijuana-related businesses.
3. Battery Energy Storage System, Tier II.
D. The following uses/activities may be permitted in the DUC C-2 District when a
conditional use permit has been issued pursuant to the provisions of Chapter 18.64
ACC:
1. Heliport.
2. Marijuana retailer.
E. The following uses/activities may be permitted in the DUC F-R District when a
conditional use permit has been issued pursuant to the provisions of Chapter 18.64
ACC:
1. Hospitals (except animal hospitals).
2. Nursing homes.
3. Religious institutions, one acre or larger lot size. Reference ACC 18.31.165 for
standards related to homeless encampments hosted by a religious organization.
4. Transmitting towers.
Page 171 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 16 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
5. Utility facilities and substations. Excludes all public and private utility facilities
addressed under ACC 18.02.040(E).
18.29.055 Deviation from development standards.
Any development project that seeks to deviate from any development standard listed in ACC
18.29.060 must be granted an administrative variance or variance, depending on the threshold
of relief, pursuant to the provisions of Chapter 18.70 ACC. (Ord. 6959 § 1 (Exh. A), 2024; Ord. 6269
§ 12, 2009; Ord. 6071 § 6 (Exh. A), 2007.)
18.29.04557 Implementing districts.
Downtown urban center zone is intended to create a distinct and strong identity for downtown
Auburn by establishing land use and design standards for review of development proposals
within the core area of the city of Auburn’s designated urban center. This zone is intended to
produce a concentration and mixture of commercial, office, medical, retail, entertainment,
residential and civic uses within the downtown area; to encourage private and public
investment, attract shoppers and visitors, and appeal to existing and new residents; to provide
a development pattern that supports pedestrian movement, bicycles and use of public transit;
and to provide opportunities to increase the city’s tax base, thereby helping to fund public
improvements and public services. In order to implement the city of Auburn Downtown Plan
and the goals, policies and objectives of the Auburn Comprehensive Plan, the zone downtown
is divided into the following districts:
A. DUC Downtown Core -125 District. DUC-The Core 125 district is implemented only in the
downtown urban center and is intended for higher density residential and mixed-uses and
commercial activity. Storefronts in this district that are located on a Pedestrian I street are
required to contain retail, residential, or personal services uses. The DUC Core is subject to
uses and development standards of this chapter and the downtown urban design guidelines.
Development in the DUC downtown Core 125 district shall not exceed 125 feet in vertical height
and is subject to other applicable height restrictions found in Chapter 18.38 ACC.
Page 172 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 17 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
B. DUC Downtown Core -75 District. The DUC downtown coreCore -75 district zone is consistent
with requirements described in the DUC downtown cCore -125, except a maximum 75-vertical-
foot height limit shall apply.
C. DUC Downtown Core-55 District. The DUC downtown core-55 zone is consistent with the
requirements described in the DUC downtown core-125 except a maximum 55-vertical-foot
height limit shall apply.
D. DUC N-R Neighborhood Residential District. The N-R district overlaps with residential areas of
downtown and is intended to support moderate density residential housing types such as
fourplexes, sixplexes, townhomes, and small apartment buildings. The N-R district allows for
middle housing options, which are designed to support gradual inflll development. The district
does allow for limited non-residential uses. This district is subject to uses and development
standards of this chapter and the downtown urban design guidelines. R-2 uses per ACC Table
18.07.020 allowed subject to the development standards of this chapter and the downtown
urban design guidelines.Development in the N-R district shall not exceed 45 feet in vertical
height.
CE. DUC H-W Health and Wellness District. This districtzonedistrict is to be used exclusively for
the hospital area, located in the vicinity of 2nd Street NE and Auburn Avenue, and is intended to
be used for medical and related uses and those uses compatible with the medical community.
Residential may be included as part of vertical mixed-use development with medical being the
primary development use. Storefronts in this district that are located on a Pedestrian I street
are required to contain retail, residential, or personal services uses. This district is subject to the
uses and development standards of this chapter and the downtown urban design guidelines.
Developments in the DUC H-W district shall not exceed 125 feet in vertical height.
EF. DUC M-1 Light Industrial District. The DUC M-1 district is intended to accommodate a variety
of light to medium intensity industrial and manufacturing uses. The primary goal of the district
is to preserve land for industrial use; however, some commercial uses are also allowable. While
allowed, outdoor storage will be regulated in a manner that mitigates visual impacts, taking
surrounding uses and vehicular corridors into consideration. This district is subject to uses and
development standards of this chapter and the downtown urban design guidelines. M-1 zone
uses allowed per ACC Table 18.23.030, subject to the development standards of this chapter
and the downtown urban design guidelines. Developments in the DUC M-1 45 feet in vertical
height.
Page 173 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 18 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
F. DUC C-1 Light Commercial District. The DUC C-1 district is intended for lower intensity
commercial uses that are adjacent and compatible with residential neighborhoods. This district
represents the primary commercial designation for small- to moderate-scale commercial
activities that are developed in a manner which is consistent with and attracts pedestrian-
oriented activities. This district encourages a broad mix of small-scale uses that are conducive
to attracting shoppers and pedestrians. This district is subject to uses and development
standards of this chapter and the downtown urban design guidelines. Developments in the
DUC C-1 district shall not exceed 45 feet in vertical height.
G. DUC C-2 Heavy Commercial District. The DUC C-2 district is intended to allow for medium-to-
high intensity commercial uses, primarily uses that are oriented to automobiles. The uses in
this classiflcation may be larger in scale and building size and have more potential for impacts
to surrounding properties and street systems than those uses permitted in the more restrictive
commercial classiflcations. This district is subject to uses and development standards of this
chapter and the downtown urban design guidelines. Developments in the DUC C-2 district shall
not exceed 75 feet in vertical height.
HG. DUC F-R Residential-Flex Residential District. The DUC F-R is districtzone is intended to
promote craft industrial /commercialand commercial uses that are compatible with residential
areas (i.e., workshop, brewery, etc.). This district is subject to uses and development standards
of this chapter and the downtown urban design guidelines.R-F zone uses allowed per ACC Table
18.07.020, subject to the development standards of this chapter and the downtown urban
design guidelines. Developments in the DUC F-R district shall not exceed 45 feet in vertical
height. (Ord. 6959 § 1 (Exh. A), 2024.)
18.29.060 Development standards.
A. The following zoning development standards apply to the DUC Core 75, Core 125, and H-W
Districts:
1. A. Minimum lot area: none.
2. B. Minimum lot width: none.
3. C. Minimum lot depth: none.
4. D. Floor Area Ratio. Floor area ratio is the cumulative amount of fioor area within a
building as a multiple of the lot area.
Page 174 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 19 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Floor Area Ratio (FAR)1
Basic Allowable “As of Right” Maximum Allowable Wwith Bonuses
Nonresidential2 Residential2 Nonresidential Residential3 Combined4
3.0 2.0 4.0 3.5 5.0
1 Floor area is measured to the inside face of exterior walls. The following shall be excluded from fioor area
calculation:
a All space below flnished grade.
b Space dedicated to structured parking.
c Space used for any bonus feature listed in subsection E of this section.
2 Minimum required FAR is 0.75; basic allowable FAR is 1.0.
3 Hotels, nursing homes, assisted living centers, etc., shall be considered residential for the purpose of
calculating FAR.
4 Allowable FAR for nonresidential and residential uses may be added together within a project, for a
combined total.
5 FAR for the DUC H-W district based on mixed use development.
1.5. E. Bonus Features Allowing Increased Floor Area Ratio. An applicant may be
required to provide a legally binding agreement or easement to ensure any of the below
features is maintained over the life of the project.
Page 175 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 20 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Feature Additional Gross Floor
Area for Each Feature
Street level retail 100 sf of fioor area for
each linear foot of retail
frontage
Restaurant 100 sf of fioor area for
each linear foot of
restaurant frontage
Public plaza 5 sf of fioor area for
each sf of plaza
Widening public
sidewalk
4 sf of fioor area for
each sf of sidewalk
made available for
public use
Canopy 4 sf of fioor area for
each sf of canopy
Daycare 104 sf of fioor area for
each sf of daycare
Health club 2 sf of fioor area for
each sf of health club
Performing space 2 sf of fioor area for
each sf of performing
space
Public meeting room 25 sf of fioor area for
each sf of meeting
room
Page 176 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 21 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Feature Additional Gross Floor
Area for Each Feature
Public art (arts
commission approval
required)
10 sf of fioor area for
each $100 of valuation
Water feature 10 sf of fioor area for
each $100 of valuation
Structured parking 10.5 sf of fioor area for
each sf of required
parking above grade
Below grade parking 1 sf of fioor area for
each sf of required
parking below grade
(including half-level
plate below grade)
Green roof 2 sf of fioor area for
each sf of green roof
Public restrooms 10 5 sf of fioor area for
each sf of public
restroom
Contribution to a public
park or cultural facility
such as a library,
museum or theater
within 0.5 miles of the
DUC zone; also, any
project including a
performance or
entertainment venue is
eligible for these
10 sf of fioor area for
each $100 of
contribution towards
acquisition or
development. This can
be used to exceed both
maximum FAR and
maximum building
height by up to 25%.
Page 177 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 22 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Feature Additional Gross Floor
Area for Each Feature
bonuses, based upon
the value of
construction
Development of open
space such as open
roof decks, balconies,
lanais or parts of the
building and improved
for outdoor living;
including rooftop
daycare play areas, dog
walking areas, etc.
5 10 sf of fioor area for
each sf of open space
F. Maximum Building Height. Maximum building height within the DUC zone shall be
based on each zoning district 75 feet, unless bonus height is permitted per subsection E
of this section.
1. If retail uses occupy the ground fioor, the minimum height for that fioor shall be 14 feet.
2. Mechanical penthouses, stair/elevator overruns, and antennas may be
excluded from building height calculation, provided they extend no more than
20 feet above the roof deck.
3. Maximum building height may be increased by up to 20 percent if the top is
designed as a nonhabitable, architectural element. This element may extend above
the increased height limit.
6. G. Minimum Building Height. The minimum height for any new structure shall be two
stories for the full extent of the building footprint.
7. Signs. The design of all signs shall be in conformance with the design standards
referenced in ACC 18.29.070. Any permanent or permanently affixed sign that projects
into the public right-of-way is subject to a right-of-way use permit. Allowable types,
numbers and sizes of signs shall be as follows:
Page 178 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 23 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
a. Freestanding: not allowed, except for monument signs as described within the
downtown Auburn design standards; no more than one per street frontage;
maximum size: 64 square feet, calculated at a rate of one square foot of sign area
per lineal foot of site frontage; minimum entitlement shall be 32 square feet;
maximum height: flve feet.
b. Wall signs: maximum area of 150 square feet per building facade, calculated at a
rate of one square foot of sign area for every lineal foot of facade; minimum
entitlement shall be 16 square feet.
c. Suspended signs: attached under a marquee or canopy: one double-faced sign, no
greater than three square feet per face allowed for each building entrance;
minimum clearance above grade: eight feet.
d. Portable Signs: may be allowed for each business entrance, subject to the following:
i. Signs may be placed within the public right-of-way, within 12 feet of a business
entrance, subject to the guidelines provided by the director in consultation with
the city engineer such that sign placement does not interfere with pedestrian or
vehicular traffic, does not create a sight hazard, and conforms to the
requirements of the Americans with Disabilities Act. Additional portable signage
may be authorized in order to support downtown events that are permitted or
sanctioned by the city.
ii. The sign shall be in accordance with the provisions of ACC 18.56.030(L).
iii. The sign area cannot exceed 42 inches in height, 32 inches in width, and be
limited to two faces.
iv. Portable signs are not permitted to be affixed to city infrastructure located
within the right-of-way (e.g., street lights, flre hydrants, public art). This includes
a prohibition of chaining or otherwise securing portable signs to such
infrastructure.
v. Signs may be displayed during business hours and shall not be displayed when
the business is closed.
vi. No landscaping may be covered, cut, damaged, or modifled to accommodate a
portable sign. The city may require replacement of any damaged landscaping
pursuant to Chapter 18.50 ACC.
vii. All portable signs shall have the permit number affixed to the back of the sign.
e. Temporary signs: allowed subject to the provisions provided in ACC 18.56.030(B).
Page 179 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 24 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
B. The following zoning development standards apply to the DUC N-R District:
1. Minimum lot area: new lots shall be a minimum of 2,000 square feet.
2. Minimum density: 7 units or lots per acre.
3. Minimum lot width: 20 feet, 35 for corner lots.
4. Minimum lot depth: none.
5. Maximum impervious surface: 75%.
6. Setbacks:
a. Front: 10 feet.
b. Front, garage: 20 feet.
c. Side, street: 10 feet.
d. Side, interior: 5 feet.
e. Rear: 5 feet.
f. Rear, garage: 20 feet.
7. Units per lot: subject to the standards contained in ACC 18.07.030(D)(1), (2), and (3).
8. Signs: subject to the signs standards contained in ACC 18.56.040(A).
C. The following zoning development standards apply to the DUC M-1 District:
1. Minimum lot area: none.
2. Minimum lot width: none.
3. Minimum lot depth: none.
4. Maximum impervious surface: none.
5. Setbacks:
a. Front: none.
b. Side, street: none, subject to the Engineering Design Standards.
c. Side, interior: none, 25 feet when adjacent to a residential zone.
d. Rear: none, 25 feet when adjacent to a residential zone.
6. Apartment buildings and mixed-use developments: subject to the zoning development
standards of ACC 18.29.060(A).
1.7. Signs: subject to the signs standards contained in ACC 18.56.040(D).
Page 180 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 25 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
D. The following zoning development standards apply to the DUC C-1 District:
1. Minimum lot area: none.
2. Minimum lot width: none.
3. Minimum lot depth: none.
4. Maximum impervious surface: none.
5. Setbacks:
a. Front: none.
b. Side, street: none, subject to the Engineering Design Standards.
c. Side, interior: none, 25 feet when adjacent to a residential zone.
d. Rear: none, 25 feet when adjacent to a residential zone.
6. Apartments buildings and mixed-use developments: subject to the zoning development
standards of ACC 18.29.060(A).
7. Signs: subject to the signs standards contained in ACC 18.56.040(B).
D. The following zoning development standards apply to the DUC C-2 District:
1. Minimum lot area: none.
2. Minimum lot width: none.
3. Minimum lot depth: none.
4. Maximum impervious surface: none.
5. Setbacks:
a. Front: none.
b. Side, street: none, subject to the Engineering Design Standards.
c. Side, interior: none, 25 feet when adjacent to a residential zone.
d. Rear: none, 25 feet when adjacent to a residential zone.
6. Apartments buildings and mixed-use developments: subject to the zoning development
standards of ACC 18.29.060(A).
7. Signs: subject to the signs standards contained in ACC 18.56.040(E).
E. The following zoning development standards apply to the DUC F-R District:
Page 181 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 26 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
1. Minimum lot area: new lots shall be a minimum of 3,000 square feet.
2. Minimum density: 7 units or lots per acre.
3. Minimum lot width: 20 feet, 35 for corner lots.
4. Minimum lot depth: none.
5. Maximum impervious surface: 75%.
6. Setbacks:
a. Front: none.
b. Side, street: none, subject to the Engineering Design Standards.
c. Side, interior: none.
d. Rear: none, 25 feet when adjacent to a residential zone.
7. Units per lot: see R-F zone under ACC 18.07.030.
8. Mixed-use developments: subject to the zoning development standards of ACC
18.29.060(A).
1.9. Signs: subject to the signs standards contained in ACC 18.56.040(B).
F. The following zoning development standards apply to all DUC districts:
1. Maximum Building Height. Maximum building height within the DUC shall be based
on each zoning district, subject to the airport overlay and Part 77 Surfaces, unless
bonus height is permitted per subsection E of this section.
a. Mechanical penthouses, stair/elevator overruns, and antennas may be excluded
from building height calculation, provided they extend no more than 20 feet
above the roof deck.
a.b. Maximum building height may be increased by up to 20 percent if the top is
designed as a nonhabitable, architectural element. This element may extend
above the increased height limit.
2. H.Parking Ratios. The following parking standards shall apply within the a DUC
districtzone in lieu of any standard noted in ACC 18.52.020 or provision of ACC
18.52.030:
Page 182 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 27 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Use Type Minimum Required
Maximum
Allowed for
Surface
Parking Lots
Retail 2 stalls/1,000 nsf 4 stalls/1,000
nsf1
Office 2 stalls/1,000 nsf 4 stalls/1,000
nsf
Residential (mixed-use,
apartment, live/work,
work/live)
0.51 stall per dwelling
unit
2 stalls per
dwelling unit
Residential (middle housing) 1 stall per dwelling
unit outside of one-
half mile walking
distance of a major
transit stop
2 stalls per
dwelling unit
outside of
one-half mile
walking
distance of a
major transit
stop
Residential (single unit
detached) over 1,200 nsf
1 stall per residence N/A
Residential (single unit
detached), 1,200 nsf and
under
0 N/A
Affordable housing units 0 N/A
Senior housing 0 1 stall per unit
Child care centers (including
home based daycares)
0 N/A
Page 183 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 28 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Use Type Minimum Required
Maximum
Allowed for
Surface
Parking Lots
Commercial (nonresidential
business purposes, including
retail, office, wholesale,
general merchandise, and
food services) over 3,000 nsf
2 stall per 1,000 nsf 4 stalls per
1,000 nsfa
Commercial (nonresidential
business purposes, including
retail, office, wholesale,
general merchandise, and
food services) 3,000 nsf and
under
0 N/A
Ground fioor nonresidential
in mixed use buildings
0 N/A
Restaurant 0.5 stall per 4 seats 1 stall per 4
seats
Industrial 0.5 stall per 1,000 nsf N/A
1 nsf = net square feet
a. 1. Parking requirements for uses not listed shall be determined by a study of
parking demand for that use, as prepared by a qualifled professional and as
accepted by the director.
2. Retail and restaurant uses less than 3,000 nsf in area shall be exempt from
parking requirements.
b. 3. Uses sharing a common parking facility may reduce the required number of
stalls by 25 percent.
c. 4. Required parking may be located off site, so long as it is: (a) located within the a
DUC zonedistrict, (b) within 1,000 feet of the property, (c) connected to the property
by streets improved with sidewalks or walkways, and (d) tied to the site by a
Page 184 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 29 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
contractual agreement reviewed and approved by the city attorney that is flled with
the city and deed of record at the county.
5. On-street parking that is located directly adjacent to a development site may be
used to satisfy minimum parking requirements and shall not be included in
determining maximum surface parking allowances.
d. 6. If subject to the standards provide in ACC 18.29.060(A), Ddedicated off-site
parking provided within a parking structure may be used to provide FAR bonuses
for a project on a separate site, provided the parking structure is located consistent
with this chapter.
e. 7. The maximum standards noted in the table above may be exceeded if all stalls
above the maximum limit are provided within a parking structure.
f. 8. Compliance with these standards is not required for a change of use within an
existing building or whenever there is an expansion of an existing building or a new
building replaces an existing building that does not increase the fioor area by more
than 25 percent.
9. In lieu of providing the minimum parking required by this section, an applicant may
request to pay for each required parking stall into a special fund that will be used to
provide and upgrade municipal parking to serve the DUC zone. The per-stall fee shall be
as specified in the city’s fee schedule.
I. Signs. The design of all signs shall be in conformance with the design standards
referenced in ACC 18.29.070. Allowable types, numbers and sizes of signs shall be as
follows:
1. Freestanding: not allowed, except for monument signs as described within the
downtown Auburn design standards; no more than one per street frontage; maximum
size: 64 square feet, calculated at a rate of one square foot of sign area per lineal foot of
site frontage; minimum entitlement shall be 32 square feet; maximum height: five feet.
2. Wall signs: maximum area of 150 square feet per building facade, calculated at a
rate of one square foot of sign area for every lineal foot of facade; minimum entitlement
shall be 16 square feet.
3. Suspended signs attached under a marquee or canopy: one double-faced sign, no
greater than three square feet per face allowed for each building entrance; minimum
clearance above grade: eight feet.
4. Portable Signs. Portable signs may be allowed for each business entrance, subject to
the following:
Page 185 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 30 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
a. Signs may be placed within the public right-of-way, within 12 feet of a business
entrance, subject to the guidelines provided by the director in consultation with the
city engineer such that sign placement does not interfere with pedestrian or
vehicular traffic, does not create a sight hazard, and conforms to the requirements
of the Americans with Disabilities Act. Additional portable signage may be
authorized in order to support downtown events that are permitted or sanctioned
by the city.
b. The sign shall be in accordance with the provisions of ACC 18.56.030(L).
c. The sign area cannot exceed 42 inches in height, 32 inches in width, and be
limited to two faces.
d. Portable signs are not permitted to be affixed to city infrastructure located
within the right-of-way (e.g., street lights, fire hydrants, public art). This includes a
prohibition of chaining or otherwise securing portable signs to such infrastructure.
e. Signs may be displayed during business hours and shall not be displayed when
the business is closed.
f. No landscaping may be covered, cut, damaged, or modified to accommodate a
portable sign. The city may require replacement of any damaged landscaping
pursuant to Chapter 18.50 ACC.
g. All portable signs shall have the permit number affixed to the back of the sign.
3. J. Landscaping. Landscaping shall be provided as deflned in the downtown Auburn
design standards, except for development subject to the middle housing and single
unit detached design standards.
4. Fences: Fencing shall be subject to the standards in ACC 18.31.020(A) through (F);
except for the DUC M-1 district in which the standards of ACC 18.31.020 (G) and (H)
also apply. Where there is a confiict between ACC 18.31.020 and the downtown
design standards shall govern.
5. Outdoor lighting: Outdoor lighting shall be subject to the standards in Chapter 18.55
ACC. Where there is a confiict between Chapter 18.55 and the downtown design
standards shall govern.
18.29.070 Design standards.
Page 186 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 31 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Adopted by reference are the downtown Auburn design standards and the Auburn Junction
design standards, a copy of which shall be maintained by the city clerk. These documents
contain standards for development of the built environment in the DUC zoning districtse. The
director shall have the authority to apply the standards to speciflc development proposals.
These standards may be amended upon approval by the community development director.
(Ord. 6828 § 1 (Exh. A), 2021; Ord. 6532 § 29, 2014; Ord. 6419 § 2, 2012; Ord. 6287 § 2, 2010; Ord. 6190 § 1,
2008; Ord. 6071 § 6 (Exh. A), 2007.)
18.29.080 Planned action standards.
A. Purpose of the planned action. The purpose of this section is to:
1. Set forth a procedure designating certain project actions within a speciflc subject site
as “planned actions” consistent with state law, RCW 43.21C.031; and
2. Provide the public with an understanding as to what constitutes a planned action
and how land use applications which qualify as planned actions will be processed by
the city; and
3. Streamline and expedite the development review process for this designated
planned action by relying on completed and existing detailed environmental analysis
for the subject site; and
4. Combine environmental analysis with land use planning; and
5. Apply the city’s development regulations together with the mitigation measures
described in the environmental impact statement (EIS) and this chapter to address
the impacts of future development contemplated by the planned action.
B. Findings. The city council makes the following flndings:
1. The City is subject to the requirements of the GMA (Chapter 36.70A RCW) and is
applying Planned Action to an Urban Growth Area (UGA).
2. The procedural requirements of Chapter 36.70A RCW have been complied with.
3. The procedural and substantive requirements of SEPA (Chapter 43.21C RCW) have
been complied with.
Page 187 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 32 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
4. The City has an adopted Comprehensive Plan complying with the GMA and is
replacing the 2001 Auburn Downtown Plan with the 2024 Auburn Downtown
Subarea Plan.
5. An EIS has been prepared for the Planned Action Area and the City Council flnds that
the EIS adequately identifles and addresses the probable signiflcant environmental
impacts associated with the type and amount of development planned to occur in
the designated Planned Action Area.
6. The 2024 Auburn Downtown Subarea Plan and Planned Action EIS, together with
adopted City development and environmental regulations, will adequately mitigate
signiflcant impacts from development within the Planned Action Area.
7. The regulation of land and development is subject to the authority and general
police power of the City, and the City reserves its powers and authority to
appropriately amend, modify, and revise such land use controls in accordance with
applicable law.
8. The 2024 Auburn Downtown Subarea Plan and EIS identify the location, type, and
amount of development contemplated by the Planned Action.
9. Essential public facilities deflned in RCW 47.06.140 are excluded from the Planned
Action and are not eligible for review or permitting as Planned Action Projects unless
they are an accessory to or part of a project that otherwise qualifles as a planned
action.
10. The Planned Action is located entirely within a UGA and applies to a deflned area
that is smaller than the overall City boundary.
11. Public services and facilities are adequate to serve the proposed Planned Action with
implementation of the City’s adopted Engineering Design Standards and the
Comprehensive System Plans.
12. The City has provided several opportunities for meaningful public involvement in the
2024 Auburn Downtown Subarea Plan and EIS including a community meeting
consistent with RCW 43.21C.440, and has considered all comments received, and, as
appropriate, has modifled the proposal or mitigation measures.
13. Future projects that are implemented consistent with the Downtown Subarea
Planned Action EIS and mitigation measures will protect the environment, beneflt
the public, and enhance economic development.
C. Applicability of the Planned Action.
Page 188 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 33 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
1. Planned Action Area. This section applies to approximately 360 acres included in the
Auburn downtown subarea project area as described in the Downtown Subarea
Planned Action EIS issued by the City on January 22, 2025 (and any addenda thereto)
and shown in Exhibit A of Ord. No. 7006 are designated as the Downtown Planned
Action Area.
2. Environmental Document. A Planned Action Project determination for a site-speciflc
project application within the Downtown Planned Action Area shall be based on the
environmental analysis contained in the Downtown Subarea Planned Action EIS. The
mitigation measures contained in this section, as well as Exhibit B of Ord. No. 7006, are
based upon the flndings of the Downtown Subarea Planned Action EIS and shall, along
with adopted City regulations, provide the framework the City will apply appropriate
conditions on qualifying Planned Action Projects within the Downtown Planned Action
Area.
3. Planned Action Designated. Uses and activities described in the Downtown Subarea
Planned Action EIS (and any addenda thereto), subject to thresholds (ACC 18.29.080(D))
and the mitigation measures contained in this section, are designated Planned Action
Projects pursuant to RCW 43.21C.440. A development application for a site-speciflc
project located within the Downtown Planned Action Area that meets the criteria in ACC
(ACC 18.29.080(D) and (E) may be designated a Planned Action Project pursuant to the
process in ACC 18.28.080(I).
D. Planned Action Thresholds. Subject to the zoning regulations for the site and the mitigation
measures described in this chapter, the maximum levels of development described below have
been evaluated in the Downtown Subarea Planned Action EIS, as described in the EIS (and any
addenda thereto), and are planned actions pursuant to RCW 43.21C.031. In order to qualify as a
planned action, total cumulative development within the Downtown Planned Action Area that
has been permitted under this chapter shall meet all of the following criteria:
1. Land Use. The following general types of land uses are considered Planned Actions:
a. Single-unit detached housing and middle housing;
b. Multi-family housing (apartments and co-living housing);
c. Mixed-use (vertical or horizontal);
d. Retail, commercial, office, services;
e. Restaurants and bars;
Page 189 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 34 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
f. Craft industry/light industrial, small food production;
g. Arts/entertainment (gallery, theater, flne arts studios);
h. Medical offices and hospital;
i. Open space, passive or active parks, trails, recreation;
j. Civic, cultural, government, and utility facilities as identifled in the Plan and
allowed in the Auburn Zoning Code;
k. Uses allowed in the Zoning Code provided for each implementing district (Chapter
18.29 DUC);
l. Other uses applicable to the 2024 Auburn Downtown Subarea Plan that are similar
to uses listed above as determined by the Community Development Director or
designee;
m. Multi-modal transportation improvements consistent with the Comprehensive
Transportation Plan and the Planned Action EIS; and
n. Enlargement or intensiflcation of uses existing at the time the Planned Action Area
is approved, so long as such enlargement or intensiflcation complies with the
Zoning Code to the extent practical.
2. Planned Action Uses. A land use shall qualify as a Planned Action Project land use
when:
a. It is within the Downtown Planned Action Area; and
b. It is within one or more of the land use categories described above; or
c. It is a common accessory use or appurtenance to a permitted use.
3. A Planned Action Project may be a single Planned Action land use, or a combination
of Planned Action land uses in a mixed-use development.
4. Development Thresholds. The following amount of new various land uses are
contemplated by the Planned Action (Table 2 Ord. No. 7006):
Page 190 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 35 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
a. Shifting development amounts between land use identifled above may be
permitted provided the transportation thresholds are not exceeded and the
development impacts identifled in the Downtown Subarea Planned Action EIS are
mitigated consistently with the mitigation measures.
b. Further environmental review may be required pursuant to WAC 197-11-172, if
any individual Planned Action Project or combination of Planned Action Projects
exceed the development thresholds specifled above and/or alter the assumptions
and analysis in the Downtown Subarea Planned Action EIS.
5. Transportation Thresholds.
a. Level of Service Threshold. The City uses an LOS rating system to evaluate the
operations of its roadway system. LOS is a concept used to describe traffic
operations from the driver’s perspective. LOS ratings are deflned by intersection
delay in seconds—LOS ranges from LOS A, which signifles no congestion and little
delay, to LOS F, which signifles substantial congestion and delay. All intersections
currently meet the City’s minimum LOS standards. As of Dec. 2025, one
intersection does not meet the City’s minimum LOS standards: C Street NW & 3rd
Street NW – LOS F. This intersection is currently identifled in the Comprehensive
Transportation Plan and 6-Year Transportation Improvement Plan for future
mitigation.
b. Concurrency. All Planned Action Projects shall meet the City's transportation
concurrency requirement standards and the level of service thresholds according
to the Comprehensive Transportation Plan and Engineering Design Standards.
Applicants shall be required to document that the project meets concurrency
standards.
c. Impact Fee. In order to mitigate transportation related impacts, all Planned Action
Projects shall pay impact fees, with adjustments made for any applicable credits.
d. Mitigation. Each Planned Action Project shall provide its proportionate share of
transportation capital improvements analyzed in the Planned Action EIS. The City
Engineer shall have the discretion to adjust the allocation of responsibility for
required improvements between individual Planned Action Projects based on
their identifled impacts.
Page 191 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 36 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
e. Discretion. The City Engineer shall have discretion to determine incremental and
total trip generation, consistent with Chapter 19.04 ACC for each Planned Action
Project proposed under this Planned Action.
E. Elements of the Environment and Degree of Impacts. A Planned Action Project that would result
in a signiflcant change in the type or degree of adverse impacts to any element(s) of the
environment analyzed in the Planned Action EIS will not qualify as a Planned Action Project.
F. Changed Conditions. Should environmental conditions change signiflcantly from those
analyzed in the Downtown Subarea Planned Action EIS, the City’s SEPA Responsible Official or
designee may determine that the Planned Action designation is no longer applicable until
supplemental environmental review is conducted.
G. Review Criteria for Planned Actions. The City’s SEPA Responsible Official or designee may
designate projects as “Planned Action Projects”, pursuant to RCW 43.21C.030, applications that
meet the following conditions:
1. The proposal is located within the Planned Action Area identifled above.
2. The proposed uses and activities are consistent with those described in the
Downtown Subarea Planned Action EIS and this Section.
3. The proposal is within the Planned Action thresholds and other criteria of this
Section.
4. The proposal is consistent with the Auburn Comprehensive Plan and the 2024
Auburn Downtown Subarea Plan.
5. The proposal’s signiflcant adverse environmental impacts have been identifled in the
Downtown Subarea Planned Action EIS.
6. The project’s signiflcant impacts will be mitigated by application of the measures
identifled ACC 18.29.080(J) and other applicable City regulations, together with any
conditions, modiflcations, variances, design review, or special permit that may be
required.
7. The project complies with all applicable local, state, and/or federal laws and
regulations, and the SEPA Responsible Official or designee determines that these
laws and regulations constitute adequate mitigation.
Page 192 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 37 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
8. The project is not an essential public facility as deflned by RCW 36.70A.200 unless
the essential public facility is an accessory to or part of a development that is
designated as a Planned Action Project.
H. Effect of Planned Action Designation. Designation as a Planned Action Project by the City’s SEPA
Responsible Official or designee means that a qualifying proposal has been reviewed in
accordance with this Section and found to be consistent with the development parameters and
thresholds established herein and with the environmental analysis contained in the Downtown
Subarea Planned Action EIS
I. Planned Action Permit Process. Applications for Planned Action Projects shall be reviewed
pursuant to the following process:
1. Development applications shall meet all applicable requirements of the Auburn
Municipal Code and this Section in place at the time of the Planned Action Project
application.
2. Applications for Planned Action Projects shall:
a. Be made on forms provided by the City;
b. Include the SEPA checklist in WAC 197-11; and
c. Meet all applicable requirements of the Auburn Municipal Code and this Section.
3. The City’s SEPA Responsible Official or designee shall determine whether the
application is complete as provided in Title 14 ACC.
4. If the application for a project within the Planned Action Area, as deflned in Exhibit A
of Ord. No. 7006, then the application will be reviewed to determine if it is consistent
with the criteria of this ordinance and thereby qualifles as a Planned Action Project.
5. The decision of the City’s SEPA Responsible Official or designee determining if a
project is a Planned Action Project is a Type 1 decision. The City’s SEPA Responsible
Official or designee shall notify the applicant of their decision in writing to the
applicant or project representative, as listed on the application, and federally
recognized tribal governments and agencies with jurisdiction over the Planned
Action Project pursuant to RCW 43.21C.440.
6. If the project is determined to qualify as a Planned Action Project, it shall proceed in
accordance with the applicable permit review procedures specifled in Title 14 ACC,
Page 193 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 38 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
except that no SEPA threshold determination, EIS, or additional SEPA review shall be
required.
7. Notice of application for a Planned Action Project shall be consistent with Title 14
ACC.
8. If notice is otherwise required for the underlying permit, the notice shall state that
the project has qualifled as a Planned Action Project. If notice is not otherwise
required for the underlying permit, no special notice is required by this Ordinance.
9. To provide additional certainty about applicable requirements, the City or applicant
may request consideration and execution of a development agreement for a
Planned Action Project, consistent with RCW 36.70B.170.
10. If a project is determined to not qualify as a Planned Action Project, the City SEPA
Responsible Official or designee shall notify the applicant and prescribe a SEPA
review procedure consistent with the City’s SEPA regulations and requirements of
state law. The notice shall describe the elements of the application that result in
failure to qualify as a Planned Action Project.
11. Projects that fail to qualify as Planned Action Projects may incorporate or otherwise
use elements of the Downtown Subarea Planned Action EIS, as well as other relevant
SEPA documents, to meet their SEPA requirements. The City SEPA Responsible
Official or designee may limit the scope of SEPA review for the non-qualifying project
to those issues and environmental impacts not previously addressed in the
Downtown Subarea Planned Action EIS.
J. Planned Action Mitigation Measures. The planned action mitigation measures set forth in
Exhibit B attached to Ord. No. 7006 and codifled in this chapter and incorporated herein by this
reference shall apply to the project identifled therein. Exhibit B shall not be codifled with the
provisions of this chapter but shall be on flle and available for review in the office of the city
clerk.
K. Amendments. Amendments to this chapter may be initiated by the city, the proponent, or the
proponent’s successor, and shall occur as follows:
1. The director may interpret the words and meaning of certain conditions in order to
resolve confiicts in implementation. All words in the ordinance codifled in this
chapter shall carry their customary and ordinary meaning.
Page 194 of 289
Chapter 18.29 ACC, DUC Downtown Urban Center District Page 39 of 39
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
2. If changes to the language of the ordinance codifled in this chapter are required,
such proposed changes shall be reviewed by the director. If, in the estimation of the
director, the proposed change is minor, then the proposed change shall be
forwarded directly to the city council for its consideration. If, in the estimation of the
director, the change is major, the proposed change shall be referred to the planning
commission which shall conduct a public hearing and make a recommendation to
the city council.
Page 195 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 1
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
City of Auburn
DOWNTOWN DESIGN STANDARDS
Draft, February 24, 2026
Contents
Chapter 1: Introduction ............................................................................................................ 3
1.1 Purpose. ............................................................................................................................................................... 3
1.2 Applicability. ........................................................................................................................................................ 3
1.3 How the provisions of this chapter are applied. ........................................................................................ 4
1.4 Definitions ........................................................................................................................................................... 5
Chapter 2 – Block-Frontage Standards ................................................................................... 6
2.1 Purpose. ............................................................................................................................................................... 6
2.2 Block-frontage designation maps. .................................................................................................................. 7
2.3 About the transparency standards. ............................................................................................................... 8
2.4 Storefront block-frontage standards. .......................................................................................................... 10
2.5 Landscaped block-frontage standards. ........................................................................................................ 14
2.6 Mixed block-frontage standards. .................................................................................................................. 16
2.7 Other/Undesignated block-frontage standards. ....................................................................................... 16
2.8 Ground-floor residential frontage standards. ........................................................................................... 18
2.9 Through-block connection frontage standards. ....................................................................................... 21
2.10 Corner site clarifications. ............................................................................................................................ 22
2.11 High-visibility street corner standards. .................................................................................................... 23
Chapter 3 - Site Planning ........................................................................................................ 24
3.1 Useable residential recreational space. ...................................................................................................... 24
3.2 Public plazas. ..................................................................................................................................................... 28
3.3 Parking lots, garages, and drive access design. .......................................................................................... 29
Page 196 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 2
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
3.4 Service areas and mechanical equipment. .................................................................................................. 35
Chapter 4 - Building Design .................................................................................................... 37
4.1 Building massing and articulation. ................................................................................................................ 37
4.2 Roofline design ................................................................................................................................................. 41
4.3 Building details. ................................................................................................................................................. 45
4.4 Blank wall treatment. ...................................................................................................................................... 49
4.5 Rooftop services area and mechanical equipment. .................................................................................. 52
Page 197 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 3
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Chapter 1: Introduction
1.1 Purpose.
These design standards are authorized by the City Council as a major implementation tool of the
Auburn Comprehensive Plan and the Downtown Auburn Subarea Plan. Overall, these standards intend
to:
• Provide clear objectives for the planning and design of development projects.
• Preserve and protect the public health, safety, and welfare of the citizens of Auburn.
• Ensure that new multifamily, mixed-use, and commercial development enhances the public’s
experience of Auburn’s Downtown Urban Center.
• Promote increased walking, bicycling, and transit use in Auburn’s Downtown Urban Center.
1.2 Applicability.
(1) New development. The provisions of this chapter apply to all development within the Downtown
Urban Center, except:
(a) Single-unit detached dwellings shall follow the single-unit detached siting and design standards of
ACC 18.31.050.
(b) Middle housing developments that meet the standards of ACC 18.25.040 and 18.04.340(B) shall
follow the middle housing design standards of ACC 18.25.070.
(c) Activities identified in ACC 18.29.020(C).
(2) Building additions, remodels, and site improvements. Three different thresholds have been
established to determine how the standards herein are applied to such projects.
(a) Level I improvements include all exterior remodels, building additions, and/or site improvements
that affect the exterior appearance of the building/site and/or cumulatively increase the gross
floor area on a site by less than 50 percent within three years of the date of permit issuance.
The requirement for such improvements is only that the proposed improvements meet
applicable standards herein, and do not lead to further nonconformance with the
aforementioned standards.
For example, if a property owner decides to replace a building façade’s siding, then the siding
shall meet the applicable exterior building material standards, but elements such as building
articulation would not be required.
(b) Level II improvements include all improvements that cumulatively increase the gross floor area
on a site by 50 percent to 100 percent within three years of the date of permit issuance. All
standards that do not involve repositioning the building or reconfiguring site development shall
apply to Level II improvements. In the case where the site includes multiple buildings and one or
more of those buildings aren’t being enlarged, such buildings are not required to be improved or
relocated.
(c) Level III improvements include all improvements that cumulatively increase the gross floor area
on a site by more than 100 percent within three years of the date of permit issuance. Such
developments shall conform to all applicable standards, except in a case where there are
multiple buildings on one site, and one or more buildings are not being enlarged. In that
Page 198 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 4
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
scenario, improvements to the building or buildings not being enlarged are not required, but
conformance with all other standards apply.
(3) Public buildings. Public buildings are exempt from the design standards herein provided design
treatments are integrated to meet the following objectives:
(a) Enliven the pedestrian environment along the adjacent sidewalks.
(b) Incorporate a prominent and inviting entry visible from the street.
(c) Building design and materials should evoke a sense of permanence.
(d) Site and building design stands out from the surrounding context as a distinct landmark and
provides visual interest from all observable scales.
1.3 How the provisions of this chapter are applied.
Most sections within this chapter herein include the following elements:
(1) Purpose statements, which are overarching objectives.
(2) Standards use words such as “must” and “is/are required,” signifying required actions.
(3) Guidelines use words such as “should” or “is/are recommended,” signifying voluntary measures.
(4) Design “Departures” are provided for specific standards in this chapter. They allow alternative
designs provided the reviewing authority determines the design meets the purpose of the standards
and other applicable criteria. See ACC 18.31.200(I) for related procedures associated with
departures.
(5) Relationship to other codes and documents. Where provisions of this chapter conflict with
provisions in any other section of the Auburn City Code (ACC), this chapter prevails unless
otherwise noted.
(6) This chapter contains some specific standards that are easily quantifiable, while others provide a
level of discretion in how they are complied with. In the latter case, the applicant must demonstrate
to the director, in writing, how the project meets the purpose of the standard or standards.
Page 199 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 5
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
1.4 Definitions
Definitions in Chapter 18.04 ACC apply to these standards. Below are supplemental definitions that
apply specifically to these design standards:
(1) Articulation - A method of styling the joints and transitions in the formal elements of architectural
design for the purpose of creating visual interest. Includes treatments to building joints and
transitions such as indents, projections, material changes, façade treatments.
(2) Belt Course - A molding or projecting course running horizontally along the face of a building.
(3) Canopy - A cover over a sidewalk providing protection from the rain or shade from the sun, which
is constructed of durable, permanent materials.
(4) Cornice - A horizontal decorative or ornamental molding around a wall or just below a ceiling.
(5) Director - means the director of the Department of Community Development or designee.
(6) Multifamily – Apartment building(s) featuring seven or more dwelling units on a single lot.
(7) Parking, structured - Parking contained within an enclosed building either part of or designed to
appear like it is part of the larger building complex, or a freestanding structure devoted exclusively
to above-grade parking.
(8) Plinth - A block used as the base of a column or other upright support.
(9) Public art - Any form of painting, mural, mosaic, sculpture, or other work of art, so long as it can be
appraised as a work of art and its value as such documented, displayed on the exterior of a building,
at or near the pedestrian entrance, or on a public plaza, and visible to users of the public right-of-
way at all times.
(10) Public plaza - An open space that is visible and accessible to the public at all times predominantly
open to the sky, and for use principally by people, as opposed to merely a setting for the building.
(11) Street level retail - Uses providing goods and services, including food and drink, adjacent to, visible
from, and directly accessible from the public sidewalk.
Page 200 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 6
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Chapter 2 – Block-Frontage Standards
2.1 Purpose.
(1) To achieve the envisioned street level aesthetic and enhance the public’s experience of Auburn’s
Downtown Urban Center.
(2) To enhance pedestrian environments by emphasizing activated ground-level block-frontage designs
for commercial, mixed-use, and multifamily developments.
(3) To minimize potential negative impacts of driveways and off-street parking facilities on the
streetscape.
(4) To promote good visibility between buildings and the street for security for pedestrians and to
create a more welcoming and interesting streetscape.
Page 201 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 7
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
2.2 Block-frontage designation maps.
(1) The block-frontage designations established by this chapter are maintained under the direction of
the director. All notations, references, and other information shown have the same force and effect
as if fully described in this title.
Designated block frontages in Downtown
Page 202 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 8
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
2.3 About the transparency standards.
All block-frontage designations contain distinct minimum façade transparency standards. The purposes
of these standards are to maintain “eyes on the street” for safety and create welcoming pedestrian
environments. The table below includes details in how they are measured.
Transparency standards
Transparency area
Storefront
Ground floor non-residential
on Landscaped block frontage
Residential buildings and
residential portions of
mixed-use buildings
The transparency area is on the
ground floor between 30” and 10’
above sidewalk grade
The transparency area is between
30” and 8’ above grade
All vertical surfaces of the façade are
used in the calculations
Other Transparency Provisions
Windows must be transparent
Ground-level window area for storefronts
and other non-residential uses that is
covered, frosted, or perforated in any
manner that obscures visibility into the
building must not count as transparent
window area. Also, mirrored glass and
highly-reflective or darkly-tined windows
must not be counted as transparent
windows.
Covered windows Perforated sign
Page 203 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 9
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Transparency standards
Display windows & parking garages
Display windows may be used for up to
25% of non-residential transparency
requirements provided they are at least
30” deep to allow changeable displays and
the interior wall is non-structural so it can
be removed if the windows are not used
for display. Tack-on display cases as
shown in the far-right example do not
qualify as transparent window area.
For parking garages (where allowed by
block frontage standards), the left image
illustrates how such a structure can meet
(and not meet) the applicable
transparency standards.
Integrated display windows Tack-on display cases
Parking garage with windows Parking garage without windows
Page 204 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 10
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
2.4 Storefront block-frontage standards.
(1) Purpose. Storefront block-frontages are the most vibrant and active shopping and dining areas
within Auburn. Blocks designated as Storefront block-frontages include continuous storefronts
placed along the sidewalk edge with small scale shops and many business entries.
There are two tiers of Storefront block frontage designations: Class A and Class B. Class B
Storefronts have slightly relaxed ground-level use, transparency, and weather protection standards.
Storefront block frontage vision and key standards.
Page 205 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 11
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
(2) Applicability.
(a) Class A Storefront standards apply to designed Storefront block frontages as set forth in the
block frontage map above.
(b) Class B Storefront standards apply to situations for Mixed and Undesignated block frontages
where developments choose to integrate storefronts on portions or all of their applicable block
frontages.
(3) Standards. Applicable development must comply with the standards in Table 2.4 below.
Table 2.4
Storefront block-frontage standards.
The symbol refers to DEPARTURE opportunities as set forth in Section 1.3 with supplemental criteria in subsection
(4) below.
Element Class A Storefront Standards Class B Storefront Standards
Ground-level
Land use See ACC18.29.050 for use provisions,
except:
Residential uses are prohibited except
lobbies and accessory-uses associated
with multifamily residential uses are
allowed provided they are limited to
30% of block-frontages.
See ACC18.29.050 for use provisions,
except:
Residential uses are prohibited except:
• Live/work units featuring ground
level space that complies with
minimum floor to floor height and
non-residential space depth herein.
• Lobbies and accessory-uses
associated with multifamily
residential uses are allowed provided
they are limited to 60% of block-
frontages.
Floor to floor height for new
buildings
(applies to the minimum non-
residential space depth)
14’ minimum.
12’ minimum.
Non-residential space depth 30’ minimum.
20’ minimum.
Building placement Buildings must be placed at the back
edge of the required sidewalk.
Additional setbacks are allowed for a
widened sidewalk or providing open
space for public use such as plazas,
courtyards, and seating areas.
Standards in this table apply when
buildings are placed at the back edge of
the required sidewalk.
Building entrances Primary building entrances must face the street or a pedestrian-oriented space
that is adjacent to the street. For corner sites, the entry may face the corner, or
one or both streets.
Façade transparency
(see Section 2.3)
At least 60% of the transparency area.
At least 50% of the transparency area.
Page 206 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 12
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Table 2.4
Storefront block-frontage standards.
The symbol refers to DEPARTURE opportunities as set forth in Section 1.3 with supplemental criteria in subsection
(4) below.
Element Class A Storefront Standards Class B Storefront Standards
Weather protection
Note: Weather protection that
encroaches over the public right-of-
way will require a permit meeting
the standards of ACC 12.60 and
ACC 12.60.050.
Weather protection is required along at
least 60% of the storefront façade, and
it must be a minimum of 5’ deep and
have 8’ to 14’ of vertical clearance.
The director may require reduced
width weather protection where
necessary to avoid interfering with
street trees, street lights, street signs,
or extending beyond the edge of the
sidewalk.
Weather protection is required along at
least 50% of the storefront façade, and
it must be a minimum of 5’ deep and
have 8’ to 12’ of vertical clearance.
The director may require reduced
width weather protection where
necessary to avoid interfering with
street trees, street lights, street signs,
or extending beyond the edge of the
sidewalk.
Parking location New surface level parking and access
features adjacent to the street are
prohibited. Parking may be placed
below, above, and/or behind
storefronts. Driveways are allowed
from designated Storefront block
frontages only when no other option
exists.
Not applicable (sites are subject to
applicable designated block frontage
parking location provisions).
Sidewalk width Sidewalks abutting storefronts must be
at least 10’ wide. Where such sidewalks
extend beyond right-of-way limits, a
public access easement is required to
accommodate the full sidewalk width.
Upper floors may cantilever over the
sidewalk to the right-of-way edge or 4’,
whichever is less.
(4) DEPARTURE criteria. Departures from the standards in Table 2.4 that feature the symbol will
be considered provided the alternative proposal meets the purpose of the standards and the
following criteria:
(a) Non-residential space floor to floor height. Some flexibility for reduced non-residential floor to
floor heights may be allowed (up to 25 percent of such space) to allow for a greater variety of
such spaces where the applicant can successfully demonstrate the proposed alternative design
and configuration of the space is viable for a variety of permitted non-residential uses.
(b) Non-residential space depth. Reduced depths on up to 25 percent of the applicable block-
frontage will be considered where the applicant can successfully demonstrate the proposed
alternative design and configuration of the space is viable for a variety of permitted non-
residential uses.
(c) Facade transparency. Departures for facade transparency in the transparency area may be
reduced to a minimum of 35 percent for block-frontages if the façade design between ground-
level windows provides visual interest to the pedestrian and mitigates the impacts of blank walls.
Page 207 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 13
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
(d) Weather-protection. The reduced extent (to no less than 50 percent of Class A and no less
than 35 percent of Class B Storefront block-frontages) or width weather-protection features (to
no less than four-feet in width) will be considered provided the designs are proportional to
architectural features of the building and building design trade-offs (elements that clearly go
beyond minimum building design standards in this chapter) meet the purpose of the standards.
Page 208 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 14
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
2.5 Landscaped block-frontage standards.
(1) Purpose. To provide standards for an optional block frontage design along Mixed-designated
streets that incorporates modest landscaped setbacks, clear pedestrian connections between the
building and the sidewalk, and minimized surface parking lots along the frontages.
(2) Applicability. Standards herein apply as an option for development on Mixed designated block
frontages and a requirement for new multifamily development. Note that developments featuring
ground-level dwelling units along block frontages, such frontages are also subject to the provisions of
Section 2.8, Ground-floor residential frontage standards.
(3) Standards. Applicable developments are subject to the Landscaped block frontage standards set
forth in Table 2.5.
Landscaped frontage vision and key standards.
Table 2.5
Landscaped block-frontage standards.
The symbol refers to DEPARTURE opportunities opportunities set forth in Section 1.3 with supplemental criteria in
subsection (4) below.
Element Standards
Ground-level
Land use As set forth in ACC 18.29.050 and 18.07.020.
Building placement 5’ minimum setback.
No minimum setback is required for upper building levels. Block frontages with
ground floor dwelling units must comply with Section 2.8.
Building entrances Building entries must face the street or a public plaza that is adjacent to the
street. For corner sites, the entry may face the corner, or one or both streets.
Page 209 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 15
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Table 2.5
Landscaped block-frontage standards.
The symbol refers to DEPARTURE opportunities opportunities set forth in Section 1.3 with supplemental criteria in
subsection (4) below.
Element Standards
Façade transparency
(see Section 2.3)
For buildings with ground-level non-residential uses, at least 35% of the
transparency area.
For buildings with ground-level residential uses, at least 15% of the entire facade.
Weather protection Weather protection at least 3’ deep must be provided over individual residential
and commercial tenant entries and at least 5’ deep for shared residential and
professional office entries.
Parking location Surface level parking and access features must be located to the side or rear of
buildings. For sites with multiple buildings, no more than 50 percent of arterial
street block frontages may be occupied by parking and vehicular access
areas.
Landscaping All areas between the sidewalk and the building must be landscaped, except for
walkways, porches, decks, and other areas meeting the definition of public plazas.
The required landscaping must meet the provisions of ACC 18.50.040(C) and
18.50.070.
For parking lot perimeter landscaping, see Section 3.3.
(4) DEPARTURE criteria. Departures to the Landscaped block-frontage standards in Table 2.5 that
feature the symbol will be considered provided the alternative proposal meets the purpose of the
standards and the following criteria:
(a) Building placement. Reduced setbacks will be considered for non-residential ground level
frontages where the façade effectively integrates a blend of storefront and landscaped frontage
elements. For example, window transparency levels should increase towards Class B Storefront
standards at a proportional rate as the setback gets smaller.
(b) Façade transparency. Façade transparency in the transparency area may be reduced from the
minimum standards by 50 percent if the façade design between ground-level windows provides
visual interest to the pedestrian and mitigates the impacts of blank-walls.
(c) Parking location. Alternative designs may be considered with some parking located between the
street and a building or buildings where such design helps to better take advantage of the site’s
context. Design treatments must be included to mitigate the impact of parking areas along the
street (in terms of visual impacts and pedestrian access to the buildings from the street).
Page 210 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 16
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
2.6 Mixed block-frontage standards.
(1) Purpose. To provide for flexibility in the design of applicable block frontages while ensuring that
block frontages create a pedestrian-friendly environment.
(2) Applicability. Standards herein apply to all sites containing designated Mixed block frontages per
the map in Section 2.2. Note that for developments featuring ground level dwelling units adjacent to
the street, the design of such block frontages are subject to Section 2.8.
(3) Standards. Applicable development may choose between the Class B Storefront standards set
forth in Table 2.4 or Landscaped block frontage standards as set forth in Table 2.5 or some
combination of the two, with modifications noted in the scenarios below:
(a) A site with a proposed storefront building (or segment of a building), the building(s) will be
subject to the Class B Storefront standards set forth in Table 2.4, except that for parking
location standards, sites will be subject to the provisions in the Landscaped block frontage
standards in Table 2.5.
(b) For a site that features proposed a building or buildings with a mix of proposed Storefront and
Landscaped block frontage designs, the storefront building segments will be subject to the Class
B Storefront standards set forth in Table 2.4, whereas everything else will be subject to the
Landscaped block frontage standards as set forth in Table 2.5.
(4) Blending frontages. Buildings may also employ designs that are a hybrid of storefront and
landscaped block frontage forms, where they feature a small landscaped setback (less than what is
required under the Landscaped block frontage standards), provided the window transparency levels
increase towards Class B Storefront standards at a proportional rate as the setback gets smaller.
Weather protection isn’t required in frontage areas where there’s more than 16 inches of
landscaping adjacent to the façade (measured perpendicular to the façade). All other standards for
Class B Storefront standards in Table 2.4 apply.
2.7 Other/Undesignated block-frontage standards.
(1) Purpose. To provide for flexibility in the design of block frontages in areas where such flexibility is
warranted.
(2) Applicability. Standards herein apply to all development on sites that are not otherwise designated
as a Storefront, Mixed, or Landscaped block frontage.
(3) Standards. Applicable developments are subject to the Other/Undesignated block frontage
standards set forth in Table 2.7, except where developments integrate storefront buildings abutting
the sidewalk edge. Such storefront buildings are subject to the Class B Storefront standards set
forth in Table 2.4.
Page 211 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 17
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Table 2.7
Other/Undesignated block-frontage standards.
The symbol refers to DEPARTURE opportunities opportunities set forth in Section 2.7 with supplemental criteria in
subsection (4) below.
Element Standards
Building placement Where allowed in the applicable zone, buildings may be placed up to the sidewalk
edge, provided they meet Class B Storefront block-frontage standards in Table
2.4. Buildings and portions thereof with ground floor dwelling units are subject to
the standards in Section 2.8.
Otherwise, there is no minimum or maximum setback provided buildings meet
applicable standards herein.
Building entrances Building entrances facing the street are encouraged. At a minimum, at least one
building entry visible and directly accessible from the street is required.
Where buildings are setback from the property line, pedestrian connections from
the sidewalk are required.
Façade transparency Storefronts abutting the back of the sidewalk are subject to Class B Storefront
façade transparency standards in Table 2.4.
Other buildings designed with non-residential uses on the ground floor within 10
feet of sidewalk, at least 30% of the ground floor between 4-8 feet above the
sidewalk.
For residential buildings, at least 15% of the entire façade (all vertical surfaces
generally facing the street).
Weather protection Buildings within 16” of the back of the sidewalk are subject to Class B Storefront
block-frontage weather protection standards in Table 2.4.
For all other buildings, weather protection at least 3’ deep must be provided over
individual residential and commercial tenant entries and at least 5’ deep for
shared residential and professional office entries.
Parking location There are no parking lot location restrictions, except for landscaped buffer
requirements set forth in PMC 20.58.005.
Landscaping Sites are subject to the landscaping requirements of Section 3.3 and Chapter
18.50 ACC.
(4) DEPARTURE criteria. Departures to the Other/Undesignated block-frontage standards in Table
2.7 that feature the symbol will be considered provided the alternative proposal meets the
purpose of the standards and the following criteria:
(a) Façade transparency. Façade transparency in the transparency area may be reduced from the
minimum standards by 50 percent if the façade design between ground-level windows provides
visual interest to the pedestrian and mitigates the impacts of blank-walls.
Page 212 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 18
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
2.8 Ground-floor residential frontage standards.
(1) Purpose. The purpose of these standards is to:
(a) Enhance the privacy and security of residents living on the ground floor.
(b) Provide an effective visual and physical transition between the public realm and the private
realm.
(c) Enhance the relationship between the building and the street through high-quality landscape and
architectural design.
(2) Applicability. All developments with ground-floor residential uses adjacent to public streets, trails,
through-block connections or other internal pedestrian connections, parks, publicly accessible
common areas, and internal common space (hereafter collectively referred to as “public and semi-
public realm”) shall comply with the frontage standards herein.
(3) Standards. Design treatments must be integrated to enhance the character of the public and semi-
public realm while respecting the privacy of adjacent residential units. Design criteria applicable to
ground-floor residential frontages are as follows:
(a) Unit setback and elevation. Provide privacy for people living in the adjacent dwelling units and
ensure the applicable public and semi-public realm environment is comfortable through all of the
following measures:
(i) Provide a five foot minimum setback from applicable public and semi-public realm elements.
The setback shall be measured from the edge of the applicable public (e.g., sidewalk) and
semi-public realm elements (e.g., walkway, public plaza, shared outdoor space). When
adjacent to an applicable public and semi-public realm element with no adjacent walkway, the
setback shall be measured from the outside edge (facing away from dwelling unit) of a
physical threshold feature (e.g., low fence or hedge) that separates semi-private outdoor
space with the applicable public and semi-public realm element as determined by the
Director.
DEPARTURES will be considered provided the design enhances the character of the
streetscape and respects the privacy of adjacent ground-floor residents.
(ii) Where the façade is within ten feet of a sidewalk (when allowed by the applicable zone) or
five feet from all other applicable public and semi-public realm elements, the ground floor
must be elevated a minimum average of 30-inches to improve privacy of such residential uses
and enhance their relationship to the street.
Page 213 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 19
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Minimum setback between a ground floor residence and
applicable public and semi-public realm element
In the left example, the 5 foot setback area is used for raised planters next to a sidewalk. In the right example, the
minimum 5 foot setback area is used for a wall and landscaped bed next to a public space.
(c) Units with direct physical access and less than ten feet setback to the sidewalk or other
applicable public and semi-public realm elements must enhance the privacy of residents and
provide an effective transition between the public and private realm by integrating all of the
following measures:
(i) Provide a physical “threshold” feature, such as a hedge, retaining wall, rockery, stair, gate,
railing, or a combination of such elements on private property, not to exceed 42 inches in
height, that defines and bridges the boundary between the applicable public and semi-public
realm element and the private entry, porch, yard, or patio. Thresholds may screen, but not
completely block, eye-level views to and from the applicable public and semi-public realm
element.
(ii) Provide an outdoor space at least four feet deep and six feet wide (24 square feet minimum
area) in the front setback, such as a porch, patio, deck, or stoop. Where feasible, this space
shall be at the same level as the interior of the unit.
(iii) Provide a covered area, porch or protected entry space, or other architectural weather
protection at least three feet deep that provides cover for a person entering the unit and a
transitional space between outside and inside the dwelling.
(iv) Landscaping planters shall be integrated into transitional areas between the dwelling unit and
the adjacent public and semi-public realm element (see examples below).
(v) Overhead building projections may cantilever over the outdoor space by up to 50 percent of
the minimum ground level setback.
DEPARTURES may be proposed for the design criteria in subsection (c) above provided the
design enhances the privacy of adjacent units and provides an effective and attractive transition
between the public and private realm.
Page 214 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 20
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Guidelines and examples of ground-level residential frontages
The above images show ground-level residential frontages with setbacks of approximately 10 feet (left image) and 5 feet
(right image) along different street frontages for the same corner apartment building. These ground level units all have
their own private unit access from the sidewalk and are elevated above the sidewalk to enhance the privacy to the
units. The landscaping elements, brick posts, split-faced concrete block stoop walls, and black metal railings help to
provide an attractive and effective transition between the public and private realms.
Page 215 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 21
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Guidelines and examples of ground-level residential frontages
Good examples: Upper left image includes a stoop design with brick terraced planters and low wrought iron fences.
Upper right and lower left images include low wrought iron fences that separate the sidewalk/pedestrian walkway from
the private open space. Lower center and right images include stoop designs with sidewalk level planters and concrete
terrace planters.
Bad examples: Despite the raised ground level, the shallow setback design in the left image above is insufficient to meet
the intent of the standards. In the above right image, the upper level building cantilever doesn’t meet the standards and
creates a cold “cave stoop” like form. The large areas of unscreened concrete walls in both examples are undesirable.
2.9 Through-block connection frontage standards.
(1) Purpose. To promote through-block connection frontage designs that enhance the character and
safety of such connections.
(2) Applicability. These standards apply to development adjacent to through-block connections, when
required (see Section 3.4).
(3) Standards. Many, but not all standards depend on the type of connection and the adjacent use.
Specifically:
(a) Non-residential building elevations (including mixed-use development with ground floor
commercial uses) facing a through-block connection are subject to Other/Undesignated block
frontage standards in Section 2.7, except that such building elevations must feature at least 10
percent window transparency to enhance the safety and visibility of the trail and connection.
(b) Residential developments adjacent to a through-block connection are subject to both the
Landscaped block frontage standards in Section 2.5 and Ground-floor residential frontage
standards in Section 2.8.
Page 216 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 22
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Good examples of through-block connections in a residential context
2.10 Corner site clarifications.
Where a property fronts onto more than one street, each building frontage must comply with the
standards for the block-frontage upon which it fronts, with the following clarifications:
(1) Entrances. For corner sites, entrances may be provided on both streets, but only one entrance is
required unless the site fronts a Storefront block frontage on both sides, in which case the entrance
shall be provided on the corner or on each street.
(2) Transparency and weather protection standards associated with corner storefronts.
(a) For corner-sites featuring a Storefront block frontage designation on one street, corner
buildings must meet applicable Storefront block frontage transparency and weather protection
standards. Such storefront buildings may be built up to the sidewalk along the other block
frontage, provided they contain at least 50 percent of the required Class A transparency and
weather protection on Storefront block frontages. Where such corner buildings contain
additional storefront uses on the non-Storefront block frontage, then those storefronts are
subject to the full Class A Storefront block frontage transparency and weather protection
standards.
(b) For street corners with Storefront designations on both block frontages, buildings must employ
the full transparency on the dominant frontage (based on the frontage width or established
neighborhood pattern), and a 50 percent reduction in minimum transparency and weather
protection is permitted on the secondary façade associated with the corner establishment.
Other storefront uses the corner establishment are subject to the full Storefront block frontage
transparency and weather protection standards.
(c) For corner storefront establishments without a Storefront designation on either street, the
block frontage containing the entry is subject to the full Class B Storefront block frontage
transparency and weather protection standards. The secondary block frontage associated with
the corner establishment must contain at least 50 percent of the required transparency and
weather protection for Class B Storefront block frontages.
Page 217 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 23
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
2.11 High-visibility street corner standards.
(1) Applicability/purpose. The high visibility street-corner requirements apply to the following sites
to accentuate designated street-corners with high visibility to the public:
(a) Street corners where at least one block frontage is designated Storefront block frontage.
(b) Other sites where a storefront building is proposed.
(2) Standards. At least one of the following special features must be included [the Figure below
illustrates acceptable examples]:
(a) Corner plaza.
(b) Cropped building corner with a special entry feature.
(c) Decorative use of building materials at the corner.
(d) Distinctive façade articulation.
(e) Sculptural architectural element.
(f) Other decorative elements that meet the purpose of the standards.
Acceptable high visibility street corner examples
The letters on the images refer to the special feature options above that are integrated into the design.
Page 218 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 24
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Chapter 3 - Site Planning
3.1 Useable residential recreational space.
(1) Purpose.
(a) To create useable space that is suitable for leisure or recreational activities for residents.
(b) To create open space that contributes to the residential setting.
(2) Applicability. These standards apply to residential developments, including portions of mixed-use
development, that include usable recreational or open space towards a density bonus. Otherwise,
the following text are guidelines that do not have to be met.
(3) Usable residential recreational space.
(a) All residential developments, including residential portions of mixed-use development, must
provide minimum usable recreational space equal to 5 percent of dwelling unit floor area. This
includes all dwelling units, but excludes the floor area of hallways, lobbies, and other common
areas. The required recreational space may be provided in a combination of ways:
(i) Shared outdoor space. All of the required recreational space may be in the form of shared
outdoor space available to all residents and meeting the requirements of subsection (b)
below. Shared roof-decks located on the tops of buildings are addressed in subsection (v)
below.
(ii) Ground/grade-level individual outdoor space. All of the required recreational space for a unit
may be provided by ground-level outdoor space that is abutting and directly accessible to the
subject unit. Such recreational spaces must be:
(A) Outdoor spaces may be located in the front, side, or rear yard provided they are generally
level, feature no dimension less than ten-feet, and enclosed by a fence, railing, and/or hedge
at least 32-inches in height to qualify
(B) Private porches may qualify as outdoor space provided they are at least 36-square-feet in
area, with no dimension less than six-feet.
Individual ground-level open space that is in excess of minimum requirements must not be
used in the calculations for determining the minimum usable recreational space requirements
for other units in the development.
(iii) Balconies and other similar private outdoor spaces. Up to 50 percent of the required
recreational space for a unit may be provided by private balconies provided such spaces are
at least 36 square feet in area, with no dimension less than four feet (not including railings),
to provide a space usable for human activity.
(iv) Common indoor recreation-areas. Up to 50 percent of the required recreational space may
be provided by common indoor recreation areas meeting the following conditions:
(A) The space must meet ADA standards and must be located in a visible area, such as near an
entrance, lobby, or high traffic corridors.
(B) The space must be designed specifically to serve interior recreational functions and not
merely be leftover unrentable space used to meet the open space requirement.
Page 219 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 25
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
(v) Shared roof-decks. For apartment buildings, up to 50 percent of the required recreational
space may be provided by shared roof-decks located on the top of buildings which are
available to all residents and meet the requirements below. For mixed-use buildings, 100
percent of the required recreational space may be provided by shared roof-decks. Design
requirements:
(A) Space must feature hard surfacing, provide amenities such as seating areas, landscaping,
and/or other features that encourage use.
(B) Space must integrate landscaping elements (at least 20 percent of the space) that enhance
the character of the space and encourage its use.
Shared roof-deck examples
(b) Shared outdoor space design requirements. Shared outdoor space can include landscaped
courtyards or decks, entrance plazas, gardens with walkways, children’s play areas, pools, and
water features provided they are accessible to all residents of the development. Accessible areas
used for storm water retention, infiltration, or other multipurpose recreational and/or green
spaces that meet the design criteria herein may qualify as shared recreational space.
Special requirements for shared outdoor spaces include the following:
(i) Shared outdoor space must be located in centralized areas that are visible from units within
the development.
(ii)Shared outdoor space must feature no dimension less than 15-feet in order to provide
functional leisure or recreational activity. Wider minimum dimensions are required
perpendicular to building elevations containing windows of dwelling units whose only solar
access is from the applicable building wall. Specifically:
(A) 20-feet minimum for such elevations up to three-stories tall.
(B) 25-feet minimum for such elevations four-stories tall.
(C) 30-feet minimum for such elevations five or more stories tall.
(iii)Shared outdoor space must feature paths, landscaping, seating, and lighting plus play
structures, sports courts, and/or other pedestrian amenities to make the area more
functional and enjoyable for a range of users.
(iv)Stairways and service elements located within or on the edge of shared recreational space
must not be included in the open space calculations.
Page 220 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 26
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
(v) Shared porches may qualify as shared outdoor space, provided they are at least eight feet in
depth and 96-square-feet in total area.
Shared outdoor and indoor recreational space examples
The upper left example is a courtyard over a parking deck. Notice the transition elements between the
courtyard and adjacent residential units. The upper right courtyard is shared by ground -level commercial uses
and apartments above.
The left image above includes a covered gathering space with outdoor grills adjacent to a landscaped commons
with a central walkway. The right image is an example of shared indoor recreation space.
The left image above includes a turf play area with mounds for fun play. The right image shows traditional play
equipment.
Page 221 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 27
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Shared outdoor space – minimum widths when abutting building elevations containing
windows of dwelling units whose only solar access is from the applicable building wall
20-feet minimum for such
elevations up to three-stories
tall.
25-feet minimum for such
elevations four-stories tall.
30-feet minimum for such
elevations five or more stories
tall
Page 222 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 28
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
3.2 Public plazas.
(1) Purpose.
(a) To encourage plazas and other pedestrian oriented spaces in downtown that enhance the
public’s opportunity for active and passive activities, such as dining, resting, people watching, and
recreational activities.
(b) To enhance the comfort and leisure capabilities of public plazas.
(c) To enhance the development character and attractiveness of the Downtown Urban Center.
(2) Applicability. These standards apply when publicly accessible plazas are included in the
development.
(3) Public plaza standards.
(a) Public plazas must abut and be within three feet in elevation of a public sidewalk. Ramps must be
provided consistent with ADA standards.
(b) Public plazas must be at least 25 feet wide.
(c) At least 10 percent of the plaza area shall be planted with trees and other vegetation. Planters
with trees, shrubs, or other vegetation are permitted to count towards the 10 percent.
(d) At least 20 percent of the plaza shall have physical or natural shade structures. Seated areas with
umbrellas, planted trees that will have a canopy radius of at least 2.5 feet, canopies, and other
shade structures are permitted to count towards the 20 percent.
(e) At least two feet of seating area (a bench or ledge at least 16-inches deep and appropriate
seating height) or one individual seat per 60-square-feet of plaza area or open space. Moveable
seating may be used to meet up to 75 percent of this requirement.
(f) Desirable public plaza features (to be encouraged) include site furniture, artwork, drinking
fountains, water features, kiosks, play structures, or other similar features.
Example of site development integrating public plazas
Page 223 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 29
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Example of site development integrating public plazas
All of the above spaces front onto sidewalks and include bordering storefronts to help enliven the spaces. The
bottom plaza includes a crushed rock surface, with concrete pathways on the side to facilitate pedestrian
movement. Note the mix of fixed and movable seating options.
3.3 Parking lots, garages, and drive access design.
(1) Purpose.
(a) To create a safe, convenient, and efficient network for vehicle circulation and parking that
minimizes conflicts with pedestrian circulation and activity.
(b) To mitigate the visual impact of parking lots on the streetscape and development context.
(c) To enhance the function, safety, and visual appearance of parking garages.
(2) Parking lot pedestrian circulation and design.
The project must provide an integrated and connected pedestrian circulation network that
encourages walking and functions as one of the defining features of the development. Specifically:
(a) Pedestrian connections not less than five feet wide shall be provided through parking lots where
they separate building entrances from sidewalks and/or transit stops. Pedestrian connection
walkways are required to meet minimum ADA requirements.
(b) Pedestrian connections through parking lots shall be clearly defined by at least two of the
following:
(i) Six-inch vertical curb in combination with a raised walkway.
(ii) Textured paving, including across vehicular lanes, such as unit pavers, stamped and scored
concrete.
(iii) Bollards.
(iv) Trellis.
Page 224 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 30
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
(v) Continuous landscape area on at least one side of the walkway that is at least three feet
wide.
(vi) Pedestrian-scale lighting.
(c) Parking lot walkways. For developments with large surface parking lots, one walkway shall be
provided for every four rows of parking, or at a maximum spacing of 200 feet.
(d) Crosswalks. Crosswalks are required when a walkway crosses an on-site paved area accessible
to vehicles.
(e) Raised crosswalks (speed tables). On sites larger than one acre, all crosswalks near major
building entrances, parking garage entries, vehicular entries to the site, and other high-traffic
areas shall be vertically raised to sidewalk level. The purpose of raised crosswalks is to provide a
continuous walking or rolling surface, increase the visibility of pedestrians, and slow the speed of
vehicular traffic. This requirement does not apply to crosswalks crossing public roadways.
(3) Through-block connection standards for the development of large sites.
Through-block connections may include private streets, shared pedestrian and vehicular access
routes, and other non-motorized routes that are intended to run between streets through an entire
block. The standards herein allow flexibility in the type of connections best suited for the particular
development and its use mix. Specific regulations for such through-block connections:
(a) The maximum distance between a street and through block connection or between through-
block connection is 330 feet.
Development sites with smaller dimensions are not required to integrate through-block
connections with new development.
(b) Departures and exceptions to the through-block connection standards:
(i) The Director may approve a departure from the dimensional standards set forth in
subsection (a) by up to 25 percent provided the quality of the through-block connection
exceeds minimum design standards.
(ii) The Director may approve an exception from the dimensional standards set forth in
subsection (a) where topography, existing uses/construction, or other geographic conditions
prevent compliance or impose an unusual hardship on the applicant, provided the proposed
design maximizes pedestrian and vehicular connectivity on the site given the constraints.
(c) Public access easement. Such through-block connections shall be provided within a public access
easement.
(d) Alignment. Specific alignments for the through-block connections will be developed during the
development review process for applicable sites.
(e) Accessibility. Through-block connections must be accessible to the public at all times and may
take a variety of forms, depending on the block size and use mix, as specified in subsection (F),
Through-block connections, below.
(f) Cantilever design. Buildings may project or cantilever into minimum required easement areas on
building levels above the connection provided a 13-foot, six-inch vertical clearance is maintained
and all other regulations are met.
(g) Through-block connection types. Unless otherwise noted below and elsewhere in this chapter,
required through-block connections may take any of the following forms set forth below. A
combination of designs set forth above may be used for each connection.
Page 225 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 31
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
(i) Private street. Such streets shall comply with the Engineering Design and Construction
Standards.
(ii) Alley. Alleys shall comply with the Engineering Design and Construction Standards.
(iii) Shared lane. The shared-lane approach can work well for lower traffic situations and helps
to reduce the total space needed to accommodate access. They must include a 20-foot wide
minimum two-way shared travel lane within a 32-foot wide public access easement. Parallel
or angled parking pockets may be integrated into the lane provided the public access
easement is widened accordingly. Landscape planters with a mixture of trees, shrubs, and
ground cover must be integrated on at least one side of the shared-lane.
(iv) Landscaped passageway design. This includes an eight-foot minimum width paved pathway
within a 24-foot public access easement. Six-foot minimum landscaping strips (with a mixture
of trees, shrubs, and ground cover) are required on each side of the path.
(v) Urban passageway design. This is a 12-foot minimum width concrete or unit paver walkway
within a public access easement (same width) with buildings generally on each side. The
building elevations on each side of an Urban passageway must include 40 percent
transparency between 30 inches and eight feet above grade. Weather protection is required
over all building entrances (at least three feet deep across the full width of the entrance).
Shared lane examples
Image courtesy eya.com
Page 226 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 32
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Landscaped and urban passageway examples
Landscaped passageway examples above and urban passageway examples below, though the lower right is a
blended example of urban and landscaped passageway.
(4) Vehicular access and design.
(a) Driveways. Driveways, where permitted by applicable Block Frontage Standards in Chapter 2,
shall meet the standards of the Engineering Design and Construction Standards, including, but
not limited to, standards for intersection spacing, distance from crosswalks, and width.
(b) Parking lot location and design. Parking lot location standards are set forth in the Block
Frontage Standards in Chapter 2. All other parking lot design standards are set forth in ACC
Chapter 18.52 unless modified herein.
(i) See subsection (2) above for interior parking lot pathways.
(ii) See subsection (5) below for parking lot landscaping standards.
(c) Garage and parking structures.
(i) The ground level of free-standing parking structures shall include at least three of the
following elements:
(A) Pedestrian scale signs.
(B) Canopies.
Page 227 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 33
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
(C) Plinths for columns.
(D) Containers for seasonal plantings.
(E) Ornamental tilework.
(F) Glass elevator and/or stair tower.
(G) An element, as approved by the City, which meets the intent of this section.
(ii) Upper levels of structured parking shall be screened or treated architecturally by two or
more of the following:
(A) Roughly square openings rather than horizontal.
(B) Planting designed to grow on the façade.
(C) Louvers.
(D) Expanded metal panels.
(E) Decorative metal grills.
(F) Spandrel (opaque) glass.
(G) An element, as approved by the City, which meets the intent of this section.
(iii) Parking garage entries and service area entries should be well-integrated into the design of
the building and should not dominate the streetscape. They should be designed and sited to
complement, not subordinate, the pedestrian entry. They shall meet the standards of the
Engineering Design Standards, Chapter 10.
(iv) Garage entry doors and gates, if provided, shall be at least 50 percent transparent between
the bottom and top of the door or gate in order to enhance the safety of garage users.
(v) Lighting fixtures within garages are encouraged to be screened from view from the street.
(5) Parking lot landscaping.
(a) Surface parking lots consisting of ten or more stalls shall feature landscaped planter beds at a
ratio of one to every six stalls. Each planter bed shall include at least one tree, a minimum
caliper of two inches at the time of planting.
(b) The minimum planter size shall be 100 square feet. Planters shall be protected by concrete
curbs and shall also feature shrubs and/or groundcover.
(c) Surface parking lots located adjacent to any street (excluding alleys) shall be screened by one or
a combination of the following:
(i) Low walls made of decorative concrete, masonry, or other similar material, not exceeding a
maximum height of 30 inches.
(ii) Raised planter walls (not exceeding a total height of 30 inches) planted with shrubs (a
minimum of 80 percent of which must be evergreen).
(iii) Landscape plantings consisting of trees (of which at least 80 percent are deciduous) and
shrubs and groundcover materials (of which at least 80 percent are evergreen).
(iv) All plant material used for parking lot screening shall provide clear views between 30 inches
and eight feet above the ground surface, for visibility and safety.
(v) Planting areas shall be a minimum of five feet in width and shall be irrigated.
Page 228 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 34
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
DEPARTURES will be considered provided the design enhances the function, safety, convenience, or
visual appearance of the parking lot and mitigates the visual appearance on the streetscape and
development context.
Parking lot street buffer examples
Page 229 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 35
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
3.4 Service areas and mechanical equipment.
(1) Purpose.
(a) To minimize adverse visual, odor, and noise impacts of mechanical equipment, utility cabinets
and service areas at ground and roof levels.
(b) To provide adequate, durable, well-maintained, and accessible service and equipment areas.
(c) To protect residential uses and abutting properties from impacts due to location and utilization
of service areas.
(2) Location of ground-related service areas and mechanical equipment.
(a) Service areas (loading docks, trash dumpsters, compactors, recycling areas, electrical panels, and
mechanical equipment areas) must be located for convenient service access while avoiding
negative visual, auditory, olfactory, or physical impacts on the streetscape environment, public
plazas, uses within the development, and abutting residentially zoned properties.
(b) Exterior loading areas. Exterior loading areas for commercial uses must not be located within
20-feet of a residentially zoned property. Where the director finds that this is the only option
for locating an exterior loading area, design measures will be required to mitigate impacts to
adjacent uses, such as adding a masonry wall at least eight-feet high.
(c) Service areas must not be visible from the sidewalk and abutting properties. Where the director
finds that the only option for locating a service area is an area visible from a street, internal
walkway or pedestrian area, or from an abutting property, the area must be screened with
structural and/or landscaping screening measures.
(3) Screening of ground related service areas and mechanical equipment.
Service elements are encouraged to be integrated within the structure. Where they are not
provided within the structure, the following standards apply:
(a) Where screening of ground-level service areas is required [see subsection (2) above], the
following applies:
(i) A structural enclosure (including gates) must be constructed of masonry, heavy-gauge metal,
or decay-resistant material that is also used with the architecture of the main building.
Alternative materials other than those used for the main building may be allowed if the
finishes are similar in color and texture or if the proposed enclosure materials are more
durable than those for the main structure. The walls must be sufficient to provide full
screening from the affected roadway, pedestrian areas and adjacent use. The enclosure may
use overlapping walls to screen dumpsters and other materials.
(ii) Where the interior of a service enclosures is visible from surrounding streets, walkways, and
buildings, an opaque or semi-opaque horizontal cover or screen must be used to mitigate
unsightly views. The horizontal screen/cover should be integrated into the enclosure design
(in terms of materials and/or design).
(b) Where loading docks are sited along block frontages (only allowed when no other reasonable
options are available as determined by the director), they must be designed to minimize impacts
on the pedestrian environment. Standards:
(i) Configure loading docks/bays to minimize their frontage length along blocks.
(ii) Integrate architectural and/or landscaping design features to screen loading dock elements
and add visual interest to pedestrians along adjacent sidewalks. See Blank Wall provisions of
Section 4.5 for standards and examples.
Page 230 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 36
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
(4) Utility meters, electrical conduit, and other service utility apparatus.
(a) Utility equipment such as power and gas meters, electrical boxes, and small-scale battery
storage systems shall have at least one of the following treatments:
(i) Screened with vegetation or landscaping.
(ii) Integrated into the building’s architecture or screened with decay-resistant material similar
in color and texture to the main building.
(iii) Wrapped with a City approved utility wrap.
(b) Project designers are strongly encouraged to coordinate with applicable service providers early
in the design process to determine the best approach in meeting these standards.
Utility meter location and screening - good and bad examples
Place utility meters in less visible locations. The lower left example is successfully tucked away in a less visible
location and screened by vegetation. The right image is poorly executed and would not be permitted in such
visible locations (along the sidewalk). Such meters must be coordinated and better integrated with the
architecture of the building.
Page 231 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 37
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Chapter 4 - Building Design
4.1 Building massing and articulation.
(1) Purpose.
To employ façade articulation techniques that reduce the perceived scale of large buildings and add
visual interest from all observable scales.
(2) Façade-articulation. All buildings must include façade-articulation features at maximum-specified
intervals to create a human-scaled pattern. These standards apply to building elevations facing
streets and parks.
(a) Maximum facade-articulation intervals:
(i) Storefronts: 35 feet. Buildings 50 feet wide or less are exempt.
(ii) Large footprint non-residential buildings (individual establishments with a building footprint of
more than 50,000 square feet). 75 feet.
(iii) Residential buildings: 30 feet. Buildings 60 feet wide or less are exempt.
(b) Articulation features. At least two of the following articulation features must be employed for all
buildings in compliance with the maximum-specified façade-articulation intervals.
(i) Use of a window-fenestration pattern.
(ii) Use of weather protection features. An example is a different canopy for each articulation
interval (rather than a continuous canopy).
(iii) Use of vertical piers/columns (applies to all floors of the façade, excluding upper level
stepbacks).
(iv) Change in building height or roofline with a difference in height, slope or pitch, direction, or
shape (such as towers or dormers).
(v) Change in building material and/or siding style (applies to all floors of the façade, excluding
upper-level stepbacks).
(vi) Vertical elements such as a trellis with plants, green wall, art element that meet the purpose
of the standard.
(vii) Providing vertical building modulation of at least 12-inches in depth if tied to a change in
roofline or a change in building material, siding style, or color. Balconies may be used to
qualify for this option if they are recessed or projected from the façade by at least 18-inches.
Note: Façade-articulation features that encroach over the public right-of-way will require a
permit meeting the standards of ACC 12.60 and ACC 12.60.050.
DEPARTURES will be considered provided they meet the purpose of the standards and the
design criteria below.
Page 232 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 38
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Façade articulation examples.
All three buildings above include a combination of window patterns, vertical building modulation, and changes in
building material/siding style. The varying styles of balconies in each also help to articulate the facades. The mixed -
use example on the let also uses separate awnings above the storefront to articulate the facade. The middle image
also uses roofline modulation.
The buildings on the left uses a combination of window patterns, vertical building modulation, roofline modulation,
and changes in building material/siding style. The middle image uses window patterns, awnings, and vertical piers.
The right image uses window patterns, vertical building modulation, and weather protection elements.
(c) DEPARTURE criteria associated with articulation standards. Proposals must meet the purpose
of the standards. The following criteria will be considered in determining whether the proposed
articulation treatment meets the “purpose”.
(i) Consider the type and width of the proposed articulation treatment and how effective it is in
meeting the purpose given the building’s current and desired context if a subarea plan is in
effect where the building is proposed.
(ii) Consider the applicable block-frontage designation. Undesigned block-frontages warrant
more flexibility than Storefront block-frontages.
(iii) Consider the size and width of the building. Smaller buildings (less than 120-feet wide)
warrant greater flexibility than larger buildings.
(iv) Consider the quality of façade materials in concert with doors, windows, and other façade
features and their ability to add visual interest to the street from a pedestrian scale and more
distant observable scales.
Page 233 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 39
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
(3) Maximum façade length. Facades of buildings longer than 150 feet and containing four or more
stories must include at least one of the following features to break up the massing of the building
and add visual interest.
(a) Provide vertical building modulation at least six-feet deep and 15-feet long. For multi-story
buildings, the modulation must extend through at least one-half of the building floors.
(b) Use of a contrasting vertical modulated design component featuring all of the following:
(i) Utilizes a change in building materials that effectively contrast from the rest of the façade.
(ii) Component is modulated vertically from the rest of the façade by an average of six-inches.
(c) Façade employs building walls with contrasting articulation that make it appear like multiple
distinct buildings. To qualify for this option, these contrasting façades must employ all of the
following:
(i) Different building materials and/or configuration of building materials.
(ii) Contrasting window design (sizes or configurations).
(d) DEPARTURES to the above standards will be considered provided the design meets the
purpose of the standards. Supplemental consideration for approving alternative designs:
(i) Width of the façade. The larger the façade, the more substantial articulation/ modulation
features need to be.
(ii) Block-frontage designation and visibility/street context. Storefront block-frontages warrant
the most scrutiny, whereas narrow Mixed or Undesignated side streets might warrant more
flexibility in design.
(iii) The type of articulation treatment and how effective it is in meeting the purpose given the
building’s context.
Illustrating maximum façade length standards and good and bad examples.
Less than 150’ long: Meets standard
More than 150’ long: Does not meet standard
Page 234 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 40
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Illustrating maximum façade length standards and good and bad examples.
Building incorporates a courtyard along the façade (technique #1 noted above) to effectively break it up into
smaller components: Meets standard.
The left building uses technique # 1 (vertical building modulation at least six -feet deep and 15-feet wide). The right
building uses technique #2 (contrasting vertical modulated design component) together with different window
fenestration designs on each side. Both examples are effective in breaking up the perceived scale of the building
and adding visual interest.
Page 235 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 41
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
4.2 Roofline design
(1) Purpose.
To employ roofline design techniques for visual interest and help direct water away from the
structure.
(2) Flat roofline/cornice design. All buildings more than three stories tall shall employ a distinctive
roofline that effectively provides an identifiable “top” to the building, including one of the following:
(a) A traditional cornice line (a horizontal decorative molding that projects along the top of a wall
or building, serving both as a decorative element and a functional component to help direct
water away from the structure).
(b) Understated cornice lines are permitted depending on the materials and design of the base and
middle elements in reinforcing the base/middle/top configuration.
(c) Contemporary overhanging cornice line, which overhangs the façade by at least four feet. Such
rooflines shall be proportional to the size and scale of the building.
(d) Employ roofline modulation option to help comply with façade articulation standards in Section
4.1. This includes adjustments in height of roofline/cornice elements.
Rooftop solar units are permitted, provided the placement and design of units visible from the
surrounding streetscape are carefully integrated into the overall design concept of the building.
DEPARTURE: Alternative roofline designs may be acceptable provided the building design,
collectively, meets the purpose of the standards. For example, additional articulation treatments
and/or detailing may help the building meet the departure criteria.
Acceptable and unacceptable roofline design.
(a) Traditional cornice lines
(b) Understated cornice lines
Page 236 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 42
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Acceptable and unacceptable roofline design.
(c) Contemporary overhanging cornice lines
Page 237 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 43
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Acceptable and unacceptable roofline design.
(d) Modulated roofline
Other acceptable rooflines (departures)
The left image features a combination of understated cornice line on main façade, with a setback upper level with a
large overhanging cornice line. The right example also features an understated cornice line but also integrates
multiple modulated elements and a top floor stepback.
Page 238 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 44
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Acceptable and unacceptable roofline design.
Unacceptable roofline
Basic roofline with no detail or articulation that help to define the “top” of the building.
Page 239 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 45
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
4.3 Building details.
(1) Purpose.
(a) To encourage the incorporation of design details and small-scale elements into building façades
that are attractive at a pedestrian scale.
(b) To integrate window design that adds depth, richness, and visual interest to the façade.
(2) Façade details – Storefront block frontages and other storefront designs. Storefront
buildings on designated Storefront block frontages and Mixed or Undesignated block frontages must
be enhanced with appropriate details. Such buildings must employ at least one detail element from
each of the three categories below for each façade articulation interval (see subsection 4.1.2).
(a) Window and/or entry treatment, such as:
(i) Transom windows.
(ii) Roll-up windows/doors. [Use of this feature exempts buildings from having to meet detailed
standards in subsections (b) and (c) below.]
(iii) Recessed entry.
(iv) Decorative door.
(v) Other decorative or specially designed window or entry treatment could be proposed via
DEPARTURE provided they meet the purpose of the standards.
Examples of architectural elements and façade attachments.
i: Transom windows iii: Recessed entry
ii: Roll-up or similar windows/doors iv: Decorative door.
Page 240 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 46
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Examples of architectural elements and façade attachments.
(b) Architectural elements and façade attachments, such as:
(i) Custom-designed weather protection element such as a steel canopy, glass, or retractable
awning. Custom-designed cloth awnings may be counted as a detail provided they are
constructed of durable, high-quality material.
(ii) Decorative rooflines, which could take a variety of forms. It could include an ornamental
molding, entablature, frieze or other roofline device visible from the ground level. If the
roofline decoration is in the form of a linear molding or board, then the molding or board
must be at least 8-inches wide. Such details could occur at an intermediate floor, where the
upper floors are set back beyond the front façade. Examples could also include a modern
interpretation of a traditional cornice line with distinct detailing.
(iii) Bay windows, trellises, towers, and similar elements.
(iv) The use of neon in artwork or to emphasize building features.
(v) Other architectural element or façade attachment details could be proposed via
DEPARTURE provided they meet the purpose of the standards.
Page 241 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 47
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Examples of architectural elements and façade attachments.
i: Custom designed weather protection iii: Bay windows, trellises, towers, etc.
Left: retractable awning. Right: custom decorative canopy
Decorative tower
ii: decorative rooflines
v: Other details that meet the
purpose of the standards.
Left: decorative cornice and top floor. Right: decorative
projecting cornice feature.
Custom hanging bike rack and repair
station integrated as a storefront design
element
(c) Building material details, including:
(i) Use of decorative building materials/use of building materials. Examples include decorative
use of brick, tile, or stonework.
(ii) Decorative kick-plate, pilaster, base panel, or other similar feature.
(iii) Decorative building-mounted light fixtures.
(iv) Hand-crafted material, such as special wrought iron or carved wood.
(v) Other building material details could be proposed via DEPARTURE provided they meet the
purpose of the standards.
DEPARTURES for façade detail standards of subsection (2) of this section will be considered
provided the façade (at the overall scale and at the individual articulation scale) meets the purpose
of the standards.
Page 242 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 48
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Examples of Examples of building material details that enhance the
visual intrigue of the building
i: Decorative building materials iii: Decorative light fixtures.
ii: Decorative kick-plate, pilaster, base panel, or similar
iv: Hand-crafted material or other details that meet the purpose of the standards.
Page 243 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 49
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
4.4 Blank wall treatment.
(1) Purpose.
(a) To avoid untreated blank walls.
(b) To retain and enhance the character of Auburn’s streetscapes.
(2) Blank wall definition. “Blank wall” means:
(a) For storefront and other buildings placed within ten feet of the sidewalk, a ground floor wall or
portion of a ground floor wall over 10-feet in height and a horizontal length greater than 15-feet
and does not include a transparent window or door.
(b) For all other buildings, a ground floor wall or portion of a ground floor wall over 10-feet in
height and a horizontal length greater than 30-feet and does not include a transparent window
or door.
Blank wall definition.
(3) Blank wall treatment standards. Untreated blank walls abutting a public street, public plazas,
shared outdoor space, or pedestrian walkway are prohibited. Methods to treat blank walls can
include:
(a) Display windows at least 16-inches of depth to allow for changeable displays. Tack-on display
cases do not qualify as a blank wall treatment.
(b) Landscape planting bed at least five-feet deep or a raised planter bed at least two-feet high and
three-feet deep in front of the wall with planting materials that are sufficient to obscure or
screen at least 60 percent of the wall’s surface within three years.
(c) Installing a vertical trellis in front of the wall with climbing vines or plant materials.
(d) Installing a mural. The use of neon in artwork is permitted.
DEPARTURES. Other design including special building detailing that adds visual interest at a
pedestrian scale will be considered. Such detailing must use a variety of surfaces.
For large visible blank walls, a variety of treatments may be required to meet the purpose of the
standards.
Page 244 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 50
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
Blank wall treatment examples.
Buildings A-C feature acceptable treatments including a combination of high quality materials and landscaping (A),
decorative lighting/sculptural element (B), and special building detailing (C). The display cases in Building D don’t
meet the 16” depth requirement, nor do they meet the purpose of the standards.
Page 245 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 51
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
(4) Firewalls. Firewalls along property lines are exempt from the above standards, but where they are
visible to the public (from the adjacent street), they must be designed to provide visual interest from
all observable distances. Examples may include the use of varying materials, textures, and/or colors,
the use of green or living walls, and/or the use of modulated building walls to form design patterns.
Murals are also encouraged as a firewall treatment. Commercial advertisements are not permitted
on such murals.
Acceptable firewall design where visible to the public.
The left images uses a combination of paint bands and climbing vines to enhance the appearance of this large
exposed firewall. The building in the right image uses simple scoring patterns and change in materials and color
on part of the top floor to add visual interest.
Plain-gray concrete block firewalls
such as this are not allowed when
visible from the street.
Page 246 of 289
AUBURN DESIGN STANDARDS - DRAFT
MAKERS architecture and urban design Page 52
Auburn Downtown Design-Standards_DRAFT CLEAN_2026-02-24
4.5 Rooftop services area and mechanical equipment.
(1) Purpose.
To obscure service and mechanical equipment from the visual sightlines of people walking through
Downtown Auburn.
(2) Rooftop equipment screening.
(a) All rooftop mechanical equipment, including air conditioners, heaters, vents, and similar
equipment must be effectively screened from public view. Screening shall be integrated with the
architecture of the building.
(b) An access easement to rooftops shall be provided to the City of Auburn, which will allow the
installation of devices for wireless coverage and maintenance of those devices. The applicant
shall also provide access to power on rooftops to be used for City wireless facilities. The
parameters of the access easement and location of devices shall be approved by the City. Any
cabling and/or power shall be secured so the facilities are not damaged by other activity on the
roof.
Examples of how to screen roof-mounted mechanical equipment
The left illustration shows how rooftop mechanical equipment can be located and screened effectively. The right
images shows effective location and screening, including side walls and a trellis to screen views from taller
surrounding buildings.
Page 247 of 289
CSTSWASTSEAUBURN AVE3RD ST SW
8TH ST NE
4TH ST SE
E MAIN ST
3RD ST NE
A ST SW4 T H S T NE
W MAIN ST
2NDSTSW AUBURN WAY N2ND ST SE
AUBURN WAY S1ST ST SW
3RD ST SE
1ST ST SE
3RD ST NW
4THSTSW SDIVISIONSTBSTNWC ST NWD ST NEA ST NE9THST
N
E
10TH ST NW
ASTNWCROSS
S
T
S
E
10TH ST NE
City of Auburn Downtown Urban Center Zoning Districts
0 0.13 0.25
Miles
DUC - Core 125
DUC - Core 75
DUC - FR Flex Residential
DUC - Health & Wellness
125
DUC - C-1 Light
Commercial
DUC - C-2 Heavy
Commercial
DUC - M-1 Light Industrial
DUC - NR Neighborhood
Residential
DUC - Downtown Urban
Center
C-AG - Auburn Gateway
C-1 - Light Commercial
C-2 - Heavy Commercial
I - Institutional
M-1 - Light Industrial
M-2 - Heavy Industrial
LF - Airport Landing Field
OS - Open Space
P-1 - Public Use
Planned Unit Development
District
R-1 - Residential 1 DU/Acre
R-2 - Residential Low
R-3 - Residential Moderate
R-4 - Residential High
Lakeland Hills PUD
R-MHC - Residential
Manufactured/Mobile Home
Community
R-NM - Nieghborhood
Mixed-Use
RC - Residential
Conservancy
R-F - Residential Flex
Terrace View District
Unclassified Use District
Information shown is for general reference purposes
only and does not necessarily represent exact
geographic or cartographic data as mapped. The
City of Auburn makes no warranty as to its accuracy.
Map ID: 6356
Printed On: 1/8/2026
Updated On: 12/30/2025
Downtown Urban Center
ATTACHMENT 3
Page 248 of 289
ACC 18.02.070, Establishment of zones Page 1 of 2
The Auburn City Code is current through Ordinance 7008, passed November 17, 2025.
18.02.070 Establishment of zones.
A. The city is divided into the following classes of zones:
1. RC, residential conservancy zone (one dwelling unit per four acres);
2. R-1, residential one unit per acre zone;
3. R-2, residential low zone;
4. R-3, residential moderate zone;
5. R-4, residential high zone;
6. R-MHC, manufactured/mobile home community zone;
7. R-F, residential flex zone;
8. R-NM, residential neighborhood mixed-use zone;
9. C-1, light commercial zone;
10. C-2, heavy commercial zone;
11. C-AG, auburn gateway zone;
121. M-1, light industrial zone;
132. M-2, heavy industrial zone;
143. L-F, airport landing field zone;
154. P-1, public use zone;
165. UNC, unclassified use zone;
176. I, institutional use zone;
187. DUC, downtown urban center, 125 District;
198. DUC, downtown urban center, 75 District;
19. DUC, downtown urban center, 55 District;
ATTACHMENT 2
Page 249 of 289
ACC 18.02.070, Establishment of zones Page 2 of 2
The Auburn City Code is current through Ordinance 7008, passed November 17, 2025.
20. DUC, neighborhood residential district;
21. DUC, health and wellness district;
22. DUC, residential-flex district;
23. DUC, light commercial district;
24. DUC, heavy commercial district;
25. DUC, light industrial district;
26. OS, open space zone.
B. The zones set out in subsection A of this section are established as the designations,
locations, and boundaries thereof as set forth and indicated on the zoning map.
C. The intent statement for each zone set forth in this title shall be used to guide the
application of the zones to all lands in the city of Auburn. The intent statements shall guide
interpretation and application of land use regulations within the zones, and any change to the
range of allowed uses within each zone through amendment to this title. (Ord. 6959 § 1 (Exh. A),
2024; Ord. 6885 § 1 (Exh. A), 2022; Ord. 6677 § 1, 2018; Ord. 6245 § 2, 2009.)
Page 250 of 289
AGENDA BILL APPROVAL FORM
Agenda Subject: Meeting Date:
Density Bonus for Existing Buildings Code Update
Staff Introduction/Presentation (Goode)
The City of Auburn is updating the Density Bonus Code for Existing
Buildings as required under HB 1757. This update allows for the density
bonuses awarded under Auburn City Code 18.02.067 to expand to the
Residential Conservancy Zone, the R-1 Residential Zone, and the R-2
Residential Low Zone. Density bonuses awarded under this code section
are required to be within existing buildings and shall not expand the square
footage of the building or the building footprint.
May 5, 2026
Department: Attachments: Budget Impact:
Community Development Staff Report , Exhibit 1
PowerPoint Presentation, Exhibit
2 ACC 18.02.067 DRAFT
Administrative Recommendation:
Planning Commission to deliberate and recommend that City Council approve a text amendment to
Title 18 “Zoning”, Section 18.02.067, to bring the City of Auburn into compliance with Revised Code
of Washington (RCW) 35.21.990 for new housing in existing buildings—Prohibitions on local
regulation. The code was previously implemented under ACC 18.02.067, Units allowed per lot, to
allow for density bonuses of up to 50 percent within existing buildings located within commercial or
mixed-use zones. The amendments within the RCW and proposed within the ACC will expand
eligibility for density bonuses to all residential zones (RC, R-1, and R-2) and provide further
clarification on when and where energy code updates are required during the proposed density bonus
within existing buildings.
Background for Motion:
Background Summary:
See attached Staff Report
Councilmember: Staff: Jason Krum
Page 251 of 289
c
PLANNING COMMISSION STAFF REPORT
AGENDA SUBJECT/TITLE:
Density Bonus for Existing Buildings Code Update
CITY FILE NO(s).:
ZOA26-0005
APPLICANT/AGENT/OWNERS:
City of Auburn
REQUEST:
Planning Commission to hold a public hearing, deliberate, and take action on proposed amendments to
regulations governing density bonuses for existing buildings to comply with the state requirements.
LOCATION:
City-wide
NOTIFICATION:
The Notice of Public Hearing was published in the Seattle Times and posted on the City’s Land Use Notice
webpage and physically at City Hall and City Hall Annex on April 20, 2026.
HEARING DATE:
May 5, 2026
SEPA STATUS:
A SEPA Environmental Checklist – Non-Project Action was submitted and reviewed with the application. A
DNS using the Optional process was issued on April 20, 2026, with the appeal period expiring on May 18,
2026.
STAFF:
Owen Goode, Planner II, Dept. of Community Development
STAFF RECOMMENDATION:
Approve a text amendment to Title 18 “Zoning”, Section 18.02.067, to bring the City of Auburn into
compliance with Revised Code of Washington (RCW) 35.21.990 for New housing in existing buildings—
Prohibitions on local regulation. The code was previously implemented under ACC 18.02.067, Units
allowed per lot, to allow for density bonuses of up to 50 percent within existing buildings located within
commercial or mixed-use zones. The amendments within the RCW and proposed within the ACC will
expand eligibility for density bonuses to all residential zones (RC, R-1, and R-2) and provide further
clarification on when and where energy code updates are required during the proposed density bonus
within existing buildings.
Page 252 of 289
Staff Member: Goode Date: April 20, 2026
Page 2 of 4
SUMMARY OF CODE CHANGES:
Density Bonus for Existing Buildings
Amend ACC 18.02.067 Units Allowed per Lot
ACC 18.02.067(H) is revised to expand density bonuses in existing buildings to include all residential
zones (RC, R-1, and R-2), and provide further clarification on when and where energy code updates are
required during the proposed density bonus within existing buildings.
FINDINGS OF FACT:
Background Summary:
1. Washington State is experiencing a housing affordability crisis. Allowing density bonuses within
existing buildings is one tool to help increase housing inventory.
2. On May 21, 2025, Planning Commission approved several code updates related to housing,
including “Density Bonus for Existing Commercial, Mixed-Use, and Apartment Buildings”, to
comply with Revised Code of Washington (RCW) 35.21.990 which allowed for 50% density
bonuses within existing commercial, mixed-use, and apartment buildings.
3. Requirements for density bonus within existing buildings take effect June 30, 2026. By this date,
jurisdictions must adopt or amend density bonus within existing buildings standards, consistent
with RCW 35.21.990. If local regulations are not updated, the statute will “supersede, preempt,
and invalidate any conflicting local development regulations.”
4. Per RCW 35.21.990, the amendment requires the density bonus allowance to expand to all
residential zones and not just specific building types. Under this current amendment, density
bonuses of up to 50 percent more than what is allowed in the underlying zone will be permissible
in the RC, R-1, and R-2 Zones.
5. Per RCW 35.21.990, cities may not require unchanged portions of an existing building that have
been used for residential or previously permit-approved conditioned space purposes, to meet the
current energy code, solely because of the addition of new dwelling units within the building.
6. Per RCW 35.21.990, changed portions of each new unit must meet current energy code except if:
a. The square footage is less than 50% of the total square footage of the existing building or
does not exceed 2,500 square feet.
b. The building owner submits documentation, in a form acceptable to the city, showing the
building's residential units' projected energy use intensity is less than or equal to the
energy use intensity target in accordance with the clean buildings performance standard
in RCW 19.27A.210; or
Page 253 of 289
Staff Member: Goode Date: April 20, 2026
Page 3 of 4
c. In all areas zoned for residential housing, an additional housing unit is created within an
existing home.
7. Per ACC 18.68.030(B) A “Zoning Text Amendment” is an application to change the text of Title 18
ACC. This type of application or initiation shall be processed as a legislative non-project decision,
consistent with ACC 14.03.060. Public notice shall be provided consistent with Title 14 ACC.
Procedural Steps:
1. The proposed text amendment (zoning code update) has been discussed with the Planning
Commission on May 5, 2026.
2. Pursuant to Revised Code of Washington (RCW) 36.70A, the text amendment was transmitted to the
Washington State Department of Commerce on February 6, 2026. The 60-day notice period ended on
April 7, 2026, with no comments received.
3. ACC 18.68.030(B) outlines the Zoning Text Amendment requirements for this proposal.
a. A “Zoning Text Amendment” is an application to change the text of ACC Title 18. This type
of application or initiation shall be processed as a legislative nonproject decision,
consistent with ACC 14.03.060. Public notice shall be provided consistent with ACC Title
14.
i. Substantive Zoning Text Amendments. For the purposes of this chapter,
substantive zoning text amendments shall be distinguished from procedural or
administrative amendments in accordance with the following: “Substantive”
matters relate to regulations that define or limit what can be done in terms of
conduct, use or action (e.g., what land use may be made of property, what
requirements apply to development, and what public infrastructure may be
required of certain developments). “Procedural” or “administrative” matters are
those that relate to the process of how an application to take such action must be
pursued (e.g., time limits for decisions and appeals, what forms must be used,
and where or how applications must be submitted. Essentially, “procedural” or
“administrative” matters are the mechanical rules by which substantive issues
may be pursued.) Substantive text amendments shall be reviewed by the planning
commission and the planning commission shall conduct a public hearing and
make a recommendation before being presented to the city council for
consideration and action.
ii. The text amendment proposed is a Substantive Zoning Text Amendment and
requires a public hearing to be held by Planning Commission prior to City Council
approval.
4. A Notice of Public Hearing (NOH) was issued on April 20, 2026. Pursuant to ACC 14.22.100, the
following methods of noticing for the Planning Commission public hearing were conducted:
a. The NOH was published in the Seattle Times on April 20, 2026.
Page 254 of 289
Staff Member: Goode Date: April 20, 2026
Page 4 of 4
b. The NOH was posted in two general public locations (City Hall and City Annex).
c. The NOH was posted on City’s Public Land Use Notice webpage.
5. A public hearing will be conducted by the Planning Commission on May 5, 2026.
EXHIBITS:
1. PowerPoint Presentation
2. Residential Density Bonus Text Amendment
Page 255 of 289
PLANNING COMMISSION
RESIDENTIAL DENSITY
BONUS CODE TEXT
AMENDMENT
PRESENTED BY
OWEN GOODE, PLANNER II
MAY 5, 2026
Department of Community Development
Planning Building Development Engineering Permit Center
Economic Development Code Enforcement
AUBURN
VALUES
S E R V I C E
ENVIRONMENT
E C O N O M Y
C H A R A C T E R
SUSTAINABILITY
W E L L N E S S
C E L E B R AT I O N
EXHIBIT 1
Page 256 of 289
Comply with RCW 35.21.990 amendments to expand
density bonuses within existing buildings to include all
residential zones
Density Bonus is currently allowed under Auburn City
Code 18.02.067(H) Density Bonus for Existing
Commercial, Mixed-Use, and Apartment Building
PURPOSE OF TEXT AMENDMENT
Page 257 of 289
Expand 50% Density Bonus within existing buildings to RC, R-
1, and R-2 Zone
Density Bonus shall not exceed 50% bonus
Density Bonus shall be entirely within the existing building
Base units allowed per lot is 4 units – 50% bonus would allow
up to 6 units when utilizing this code section
EFFECT OF TEXT AMENDMENT
Page 258 of 289
REASON FOR TEXT AMENDMENT
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
•One of many tools to combat the current
housing crisis
•Not a single solution to the housing crisis
Source: Opticos Design
Page 259 of 289
RECOMMENDATION
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Recommend approval of the draft text
amendments to Title 18 of the Auburn City
Code which allows for density bonuses of up
to 50% of what is allowed in the underlying
zone within the RC, R-1, and R-2 zones
Page 260 of 289
QUESTIONS?
Department of Community Development
Planning Building Development Engineering Permit Center
Economic Development Code Enforcement
AUBURN
VALUES
S E R V I C E
ENVIRONMENT
E C O N O M Y
C H A R A C T E R
SUSTAINABILITY
W E L L N E S S
C E L E B R AT I O N
Page 261 of 289
ACC 18.02.067, Units allowed per lot Page 1 of 2
The Auburn City Code is current through Ordinance 7008, passed November 17, 2025.
18.02.067 Units allowed per lot.
H.Density Bonus for Existing Commercial, Mixed-Use, and ResidentialApartment Buildings. Existing
commercial, mixed-use, and residentialapartment buildings may qualify for a density bonus of
up to 50 percent when adding housing units; provided, that:
1.The additional housing units are located entirely within the existing building envelope, and
generally applicable health and safety standards, including but not limited to building code
standards and fire and life safety standards, can be met within the building;
2.The existing parking is not reduced through the addition of new housing units;
3.The existing building is located within one of the following zones that allows for mixed-use
development: RC, R-1, R-2, R-3, R-4, R-NM, R-F, C-2, C-AG, and M-1;
4.The addition of dwelling units complies with mixed-use and apartment development design
standards when located along multimodal transportation corridors;
5.The building received a final certificate of occupancy three years prior to the permit
application to add housing units;
6.The proposal is consistent with the development standards of the underlying zone;
7.The proposal is allowed the following exemptions:
a.The proposal shall not be required to provide additional parking for added housing
units;:
b.The proposal shall not be required to meet the current energy code for unchanged
portions of an existing building that have been used for residential or previously
permit-approved conditioned space purposes, solely because of the addition of new
dwelling units within the building. New units provided are not exempt from current energy
code requirements.
c.The proposal shall be exempt from providing a transportation concurrency study under
RCW 36.70A.070 or an environmental study under Chapter 43.21C RCW based on the
EXHIBIT 2
Page 262 of 289
ACC 18.02.067, Units allowed per lot Page 2 of 2
The Auburn City Code is current through Ordinance 7008, passed November 17, 2025.
addition of residential units within an existing building. (Ord. 6977 § 1 (Exh. A), 2025; Ord. 6959
§ 1 (Exh. A), 2024.)
8. When any other existing building is converted to new dwelling units, changed portions of
each of those new units must meet the requirements of the current energy code, except if:
a. The square footage of new dwelling units does not exceed 2,500 square feet or 50
percent of the total building square footage, whichever is greater;
b. The building owner submits documentation, in a form acceptable to the city, showing
the building's residential units' projected energy use intensity is less than or equal to the
energy use intensity target in accordance with the clean buildings performance standard in
RCW 19.27A.210; or
c. In all areas zoned for residential housing, an additional housing unit is created within an
existing home.
The Auburn City Code is current through Ordinance 7008, passed November 17, 2025.
Disclaimer: The city clerk’s office has the official version of the Auburn City Code. Users should
contact the city clerk’s office for ordinances passed subsequent to the ordinance cited above.
City Website: www.auburnwa.gov
Hosted by General Code.
Page 263 of 289
AGENDA BILL APPROVAL FORM
Agenda Subject: Meeting Date:
Nonconforming Code Update
Staff Introduction/Presentation (Teague)
Staff to discuss an update to Chapter 18.54 “Nonconforming Structures,
Land And Uses”.
May 5, 2026
Department: Attachments: Budget Impact:
Community Development Memorandum, Exhibit 1
PowerPoint Presentation, Exhibit
2 Chapter 18.54 ACC Text
Amendment, Exhibit 3 ACC
Section 18.70.020 Text
Amendment
Administrative Recommendation:
Background for Motion:
Background Summary:
See attached Memorandum
Councilmember: Staff: Jason Krum
Page 264 of 289
PLANNING COMMISSION MEMORANDUM
TO: Judi Roland, Chair, Planning Commission
Bill Stewart, Vice Chair Planning Commission
Planning Commission Members
FROM: Alexandria Teague, Planning Services Manager
Dept. of Community Development
DATE: April 14, 2026
RE: Nonconforming Code Update – Chapter 18.54 Auburn City Code
I. BACKGROUND & PURPOSE
A nonconforming use is one that when originally established complied with the categories of uses
established 1 , development standards, and other applicable regulations at the time but no longer
conforms. A structure, land, and use may become nonconforming when either it 1) becomes prohibited
(i.e. is no longer allowed), 2) the applicable development standards change, or 3) the zoning district of
which it resides changes.
Washington State law does not contain specific standards or regulations governing nonconforming uses.
In 1998 under “Rhod-A-Zalea v. Snohomish County” the State Supreme Court stated,
“While some states' authority to terminate, alter, or extend nonconforming uses is expressly
granted or withheld in zoning enabling acts, Washington's enabling acts are silent regarding the
regulation of nonconforming uses. See R. Settle, Washington Land Us e § 2.7(d). Instead, the
state Legislature has deferred to local governments to seek solutions to the nonconforming use
problem according to local circumstances. In Washington, local governments are free to
preserve, limit or terminate nonconforming uses subject only to the broad limits of applicable
enabling acts and the constitution.”
Further, the Washington Administrative Code (WAC) related to shorelines and shoreline master programs
(Chapter 173-27 WAC) states, “Local governments typically develop their own approaches to addressing
nonconforming use and development. This section is intended to apply if a shoreline master program does
not contain locally adopted nonconforming use and development standards.”
A legal (or legally established) nonconforming structure, land, or use means it was legal or lawful when it
was established. This often means it was permitted outright or obtained a land use approval, such as an
administrative use permit or conditional use permit, and obtained other applicable permits, such as a
building permit. Note – some structures, such as a small shed (under 120 square feet), do not require a
permit, yet still must meet the setbacks and building height of the zoning district in which is it placed. In
1 Per ACC 18.02.120 Chapters 18.07 through 18.44 ACC establish permitted, administrative, conditional, and prohibited
uses, by zone, for all properties within the Auburn city limits. All principal uses in a given zone are one of four types: 1.
Permitted use; 2. Administrative use; 3. Conditional use; and 4. Prohibited use; each of these are defined under IV
DEFINITIONS.
Page 265 of 289
Staff Member: Teague Date: April 8, 2026
2
this case, if the small shed met setbacks and the building height of the zoning district, it would be
considered legally established. If for example, the shed needed to be closer to the property line than what
is permissible in the zoning district, relief through a variance may be obtained. If the variance was
obtained, then the shed may be closer to the property line, and it would again be considered legally
established. Finally, if the zoning district changed and the small shed was no longer allowed or the
setbacks changed, since it was legally established, it would be considered a legally established
nonconforming use.
There have been numerous court cases determining that legally established nonconforming structures,
land, and uses may continue to exist or operate, and inform City regulations. Court case “Rhod-A-Zalea
v. Snohomish County” (1998) states “These rulings are consistent with the principle that a nonconforming
use has a "vested" or "protected" right to continue without being subject to immediate termination.”
A vested right is related to the concept of vesting. In short, vesting means that a structure, land, or use is
subject to use controls, development, and regulations in effect at the time of a complete application. Per
Revised Code of Washington (RCW) 19.27.095(1),
“A valid and fully complete building permit application for a structure, that is permitted under
the zoning or other land use control ordinances in effect on the date of the application shall be
considered under the building permit ordinance in effect at th e time of application, and the
zoning or other land use control ordinances in effect on the date of application.”
Vested rights are important because if the categories of uses established, development standards, or
zoning district changes, the use is still allowed to continue under its vested rights. That is, as long as it is
continued and maintained in conformance with the regulations of Chapter 18.54 ACC.
Nonconforming structures, land, and uses are governed by the development regulations contained in
Chapter 18.54 of the Auburn City Code. The purpose of this Chapter is to allow for the continuance and
maintenance of legally established nonconforming structures, land, and uses. The development
regulations in Chapter 18.54 ACC have remained largely unchanged since 1987 (Ord. No. 4229). The
intent of this code update is to provide greater flexibility in the continuation and maintenance of legally
established nonconforming structures, land, and uses, particularly in light of recent and ongoing
changes to the City’s zoning development standards.
During the last Periodic Comprehensive Plan update2, completed at the end of 2024, the City made
major adjustments or changes to the Zoning Ordinance (Title 18) and the Zoning Map (the City’s official
map depicting all zones within the city). These changes were completed such that the Zoning Ordinance
and Zoning Map would be consistent with changes to the City’s Comprehensive Plan and
Comprehensive Land Use Map. Since 2024, the City has also updated the Downtown Subarea Plan and
all zones within the downtown subarea. New State legislation, such as House Bill (HB) 14913 related to
2 Per RCW 36.70A.130 (the Growth Management Act) each city and county in Washington state is required to conduct a
periodic update of its comprehensive plan and development regulations. In general, the purpose is to ensure consistency
with the Puget Sound Regional Council Vision 2050, the Countywide Planning Policies (for Auburn this means both Pierce
and King County), any changes in state laws over the intervening time, and to respond to changing conditions within the
local community.
3 HB 1491, passed in 2025, requires cities to plan for transit-oriented development (TOD) and increased density near
“station areas”. A station area may be either a rail station area or a bus station area. A rail station area is comprised of all
lots within that are fully or partially within 0.5 miles walking distance of an entrance to a train station. A bus station ar ea is
comprised of all lots within that are fully or partially within 0.25 miles walking distance of a stop on a fixed route bus system
that is designated as a bus rapid transit stop in a transit development plan. A full summary is provided in the Final bill
report: https://lawfilesext.leg.wa.gov/biennium/2025-26/Pdf/Bill%20Reports/House/1491-
S3%20HBR%20FBR%2025.pdf?q=20260407114627.
Page 266 of 289
Staff Member: Teague Date: April 8, 2026
3
Transit Oriented Development within “station areas”, will further result in changes to the Zoning
Ordinance and Zoning Map. As a result of rapid changes within such a short time frame, the City is
proposing to provide more flexibility for the continuance and maintenance of legal nonconforming
structures, land, and uses. These changes amin to reduce unintended hardships on property owners and
businesses while maintaining the City’s long-term vision and consistency with the Comprehensive Plan.
The significant changes are summarized below.
II. SUMMARY OF PROPOSED CODE CHANGES
SECTION 18.54.060 Maintenance, damage repairs and restorations, additions, enlargements,
moving or relocation of nonconforming structures, and residential structures.
(G) – Revises the tracking period for cumulative improvements from “the lifetime of the nonconforming
use” “to within five years of the date of permit issuance”. This provides more clarity and administrative
consistency when tracking of the total value of improvements.
(I) – Allows for a legal nonconforming structure or use to expand the existing use or structure up to 10%
administratively by the Community Development Director or designee or more than 10% (not to exceed
25%) through a special exception4. Administratively approval approved expansion will make it easier for
nonconforming uses and structures to expand by a modest amount.
(K) – Allows for the rebuild of middle housing and apartments, in addition to single family residences. The
rebuild/replacement relief afforded to single family residences is expanded to more housing types –
middle housing (up six units) and apartments (seven units and above).
SECTION 18.54.070 Abatement of nonconforming structures and uses.
(B) – Increases the period of which a nonconforming use is discontinued or becomes vacant from 180
days to one year. This allows uses and structures, including existing businesses, a more reasonable
amount of time to find new tenants or occupants for their use, before losing their nonconforming status
and vested rights.
(C) – Allows for administrative approval of extensions for discontinued nonconforming uses or structures
for a maximum of three years, through one -year increments, where warranted. This new regulation
authorizes the Community Development Director or designee to administratively approve of extensions.
This will help discontinued uses and structures that need more time finding new tenants or occupants.
SECTION 18.54.080 Amortization and abatement of outdoor storage.
Revised requirements for outdoor storage yards, in the M-1, Light Industrial Zone. Rather than requiring
compliance with the landscape and screening requirements of Chapter 18.50 ACC “Landscaping and
Screening”, within a fixed timeframe, compliance is now triggered only when improvements are made
under ACC Section 18.54.060.
III. TEXT AMENDMENT
Draft text amendments are shown by strikeout/underline and are attached to this memo as Attachments
2 and 3.
IV. DEFINITIONS (in alphabetical order)
1) Administrative use means a use permitted in a zone only after review and approval by the planning
director or designee. Administrative uses are those which typically have some potential for impacts to
4 Special exception are specific deviations from development regulations granted by the Hearing Examiner following a
public hearing and are provided in Chapter 18.70 “Variances, Special Exceptions, and Administrative Appeals”.
Page 267 of 289
Staff Member: Teague Date: April 8, 2026
4
neighboring properties, but which may be permitted within a zone following review by the city to
establish conditions mitigating impacts of the use and to assure compatibility with other uses in the
zone.i
2) A building means any structure having a roof supported by columns or walls used or intended to be
used for the shelter or enclosure of persons, animals or property of any kind.ii
3) Conditional use means a use permitted in a zone only after review and approval by the hearing
examiner. Conditional uses are such that they may be compatible only on certain conditions in
specific locations in a zone, or if the site is regulated in a certain manner in orde r to achieve the
purposes of this title.iii
4) Density is a measure of population, housing units, or building area related to land area, and is
expressed as a ratio, e.g., units per acre or square feet of lot area per unit. See ACC 18.02.065 for the
methodology for calculating density.iv
5) Development standards means regulations pertaining to setbacks, landscaping, height, site coverage,
signs, building layout, site design and related features of land use.v
6) Development regulations means the controls placed on development or land use activities by the city,
including, but not limited to, zoning ordinances, critical areas ordinances, shoreline master programs,
official controls, planned unit development ordinances (if permitted by city code) and subdivision
ordinances together with any amendments thereto. A development regulation does not include a
decision to approve a project permit application, as defined in ACC 14.02.070, even though the
decision may be expressed in a resolution or ordinance of the city.vi
7) Intensity refers to the level of development or activity on a site, in terms of both the nature of uses and
the concentration of those uses as indicated by residential density (dwelling units per acre) or floor
area ratio. For example, a site with a mixed-use complex with a commercial retail component and a
high density multifamily residential component would display a higher level of intensity than the same
sized property with a low density, single-family residential development.vii
8) Nonconforming use means a use which when commenced, complied with use regulations applicable
at the time when such use was commenced, and which does not conform to the existing use
regulations of the zone where the use is now being conducted or carried on. The term “nonconforming
use” shall be applicable to uses of buildings, structures, and land. This definition does not include
those uses existing in the zone, prior to the adoption of this title, which would now require an
administrative or conditional use permit to operate in the zone. Any expansion of the space, volume or
area of the use would then require an administrative or conditional use permit as this title may
require.viii
9) Nonconforming lot is one that, at the time of its establishment, met the minimum lots size
requirements for the zone in which it is located, but which, because of subsequent changes to the
minimum lot size applicable to that zone, is now smaller than that minimum lot size.ix
10) Nonconforming structure is a structure that complied with zoning and development regulations at the
time it was built, but which, because of subsequent changes to the zoning and/or development
regulations, no longer fully complies with those regulations.x
11) Permitted use means a land use that is allowed outright within a zone.xi
12) Prohibited use means any use which is not specifically enumerated or interpreted by the city as
allowable in that zone. Any use not specifically listed as a permitted, administrative, conditional, or
accessory use is prohibited, except those determined to be unclassified and permitted by the planning
director pursuant to ACC 18.02.120(C)(6). Any prohibited use is illegal.xii
13) Setback means the distance between a lot line and the corresponding parallel setback line.xiii
14) Setback line means a line which defines a setback as required by this title, which is parallel to but
other than a lot line, between which no building, structure, or portion thereof shall be permitted,
erected, constructed, or placed unless specifically pe rmitted by this title.xiv
15) Site is an area comprised of one or more legally created lots or parcels used for a development
proposal in order to calculate compliance with the standards and regulations of this title.xv
16) Structure is that which is built or constructed, an edifice or building of any kind, or any piece of work
artificially built up or composed of parts joined together in some definite manner, except benches,
Page 268 of 289
Staff Member: Teague Date: April 8, 2026
5
statuary, planter boxes less than 42 inches in height, and fences 72 inches or under in height, or paved
areas.xvi
17) Use means an activity or purpose for which land or premises or a building thereon is designed,
arranged, intended, or for which it is occupied or maintained, let or leased.xvii
18) Variance means an adjustment in the application of the specific regulations of this title to a particular
piece of property.xviii
19) Zone means an area accurately defined as to boundaries and location on an official map to which a
uniform set of regulations applies controlling the types and intensities of land uses, as set forth in this
title.xix
20) Zoning Ordinance. The purpose of this title [The Zoning Ordinance] is to implement the city’s
comprehensive plan. This title will be used to further the growth and development of the city
consistent with the adopted comprehensive plan and its implementing elements. This title will also
further the purpose of promoting the health, safety, morals, convenience, comfort, prosperity, and
general welfare of the city’s population and to prevent and abate public nuisances.xx
V. ATTACHMENTS
1) PowerPoint Presentation
2) Chapter 18.54 ACC Text Amendment
3) ACC Section 18.70.020 Text Amendment
i Auburn City Code (ACC) 18.04.025
ii ACC 18.04.190
iii ACC 18.04.260
iv ACC 18.04.300
v ACC 18.04.310
vivi ACC 14.02.040
vii ACC 18.04.499
viii ACC 18.04.650
ix Municipal Research and Services Center of Washington (MRSC), https://mrsc.org/explore-
topics/planning/administration/nonconforming-uses (accessed 4/2/26).
x MRSC, https://mrsc.org/explore-topics/planning/administration/nonconforming-uses (accessed 4/2/26).
xi ACC 18.04.696
xii ACC 18.04.752
xiii ACC 18.04.810
xiv ACC 18.04.815
xv ACC 18.04.821
xvi ACC 18.04.890
xvii ACC 18.04.900
xviii ACC 18.04.910
xix ACC18.04.960
xx ACC 18.02.030
Page 269 of 289
PLANNING COMMISSION
NONCONFORMING
CODE UPDATE
PRESENTED BY
ALEXANDRIA TEAGUE,
PLANNING SERVICES MANAGER
MAY 5, 2026
Department of Community Development
Planning Building Development Engineering Permit Center
Economic Development Code Enforcement
AUBURN
VALUES
S E R V I C E
ENVIRONMENT
E C O N O M Y
C H A R A C T E R
SUSTAINABILITY
W E L L N E S S
C E L E B R AT I O N
EXHIBIT 1
Page 270 of 289
WHAT ARE NONCONFORMING USES?
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Page 271 of 289
WHAT ARE NONCONFORMING USES CONTINUED…
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Page 272 of 289
18.54.010
18.54.020
18.54.030
18.54.040
18.54.050
18.54.060
18.54.070
18.54.080
Intent
Continuance
Use of nonconforming land
Nonconforming signs
Changes of use…
Maintenance…
Abatement
Amortization of outdoor
storage
WHICH STANDARDS GOVERN?
CHAPTER 18.54 ACC
Page 273 of 289
PROPOSED CODE CHANGES
18.54.060(G)
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Page 274 of 289
PROPOSED CODE CHANGES
18.54.060(I)
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Page 275 of 289
PROPOSED CODE CHANGES
18.54.060(K)
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Page 276 of 289
PROPOSED CODE CHANGES
18.54.070(B)
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Page 277 of 289
PROPOSED CODE CHANGES
18.54.070(C)
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Page 278 of 289
PROPOSED CODE CHANGES
18.54.080
SERVICE ENVIRONMENT ECONOMY CHARACTER SUSTAINABILITY WELLNESS CELEBRATION
Page 279 of 289
QUESTIONS?
Department of Community Development
Planning Building Development Engineering Permit Center
Economic Development Code Enforcement
AUBURN
VALUES
S E R V I C E
ENVIRONMENT
E C O N O M Y
C H A R A C T E R
SUSTAINABILITY
W E L L N E S S
C E L E B R AT I O N
Page 280 of 289
Chapter 18.54 ACC, Nonconforming Structures, Land and Uses Page 1 of 7
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
Chapter 18.54
NONCONFORMING STRUCTURES, LAND AND USES
Sections:
18.54.010 Intent.
18.54.020 Continuance of nonconforming structures and uses.
18.54.030 Use of nonconforming land.
18.54.040 Nonconforming signs.
18.54.050 Changes of use, tenancy, ownership or management.
18.54.060 Maintenance, damage repairs and restorations, additions,
enlargements, moving or relocation of nonconforming structures,
and residential structures.
18.54.070 Abatement of nonconforming structures and uses.
18.54.080 Amortization and abatement of outdoor storage.
18.54.010 Intent.
Amendments over time to regulatory authority provided within this title may result in
structures, land and uses which no longer conform with the provisions set forth for the district
in which they are situated. Therefore it is the intent of this chapter to allow for the continuance
and maintenance of legally established nonconforming uses subject to standards and
provisions prescribed within this chapter. (Ord. 4229 § 2, 1987.)
18.54.020 Continuance of nonconforming structures and uses.
Any nonconforming structure or use lawfully existing on the effective date of this title, or any
subsequent amendments to this title, may be continued and maintained in conformance with
provisions of this chapter, provided no enlargement of area, space or volume occupied by the
nonconforming use occurs. Any nonconforming structure authorized by a valid building permit
prior to the effective date of the ordinance codified in this title, or any subsequent amendments
to this title, may be completed and used in accordance with the plans, specifications and
EXHIBIT 2
Page 281 of 289
Chapter 18.54 ACC, Nonconforming Structures, Land and Uses Page 2 of 7
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
regulations under which such permit was issued. Expiration of authorized permits will result in
a loss of vested right for construction and use of such structure. (Ord. 4229 § 2, 1987.)
18.54.030 Use of nonconforming land.
If any parcel of land with a minimum lot size or lot dimension which is less than that prescribed
for by the district in which such parcel is located, was subdivided into lots according to a plat of
record on or before the effective date of the ordinance codified in this title, or any subsequent
amendments to this title, then the fact that the parcel of land does not meet the minimum lot
size or lot dimension requirements as set forth in this title shall not prohibit the property from
being utilized; provided, that all other regulations prescribed for that district by this title are
complied with, except as provided for in Chapter 18.31 ACC. (Ord. 4229 § 2, 1987.)
18.54.040 Nonconforming signs.
Nonconforming signs shall be subject to provisions of Chapter 18.56 ACC. (Ord. 4229 § 2, 1987.)
18.54.050 Changes of use, tenancy, ownership or management.
Changes of use, tenancy, ownership or management may occur to any existing legally
established and continued nonconforming use under one or more of the following
circumstances:
A. Any part of a structure occupied by an existing legally established and continued
nonconforming use may be changed to a use which, in the opinion of the planning dDirector of
Community Development or designee, is of the same or of a more restrictive nature. When the
use of a nonconforming structure is hereafter changed to a more restrictive use, the structure
shall not thereafter be used for a less restrictive use.
B. There may be a change of tenancy, ownership or management of any existing legally
established and continued nonconforming use provided there is no change in the nature or
Page 282 of 289
Chapter 18.54 ACC, Nonconforming Structures, Land and Uses Page 3 of 7
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
character of such nonconforming use except as authorized within this chapter. (Ord. 4229 § 2,
1987.)
18.54.060 Maintenance, damage repairs and restorations, additions,
enlargements, moving or relocation of nonconforming
structures, and residential structures.
A. Ordinary maintenance of a nonconforming structure which includes minor interior and
exterior repairs and incidental alterations is permitted. Minor maintenance and repair may
include but is not limited to painting, roof repair and replacement, plumbing, wiring,
mechanical equipment replacement, and weatherization. Incidental alterations may include
construction of nonbearing walls or partitions.
B. No structural alterations, as defined by the Uniform International Building Codes, shall be
made except as required by law or ordinance; provided, that the cost of such work shall not
exceed 50 percent of the assessed valuation of such structure as established by the most
current county assessor’s tax roll.
C. A nonconforming structure having been damaged or partially destroyed to an extent not
exceeding 50 percent of the assessed valuation of such structure as established by the most
current county assessor’s tax roll, may be restored to its original condition, as authorized by the
city’s building official, and its immediately preceding or existing use at the time of partial
destruction may be continued or resumed. Restoration shall begin within one year and be
completed within two years of the date of partial destruction. If restoration is not started within
one year, then the reuse and occupancy of the structure shall conform to all the regulations of
the district in which the use is located.
D. Structures or lands which are nonconforming as to use regulations shall not be enlarged or
intensified in any manner unless the enlargement within such structures or lands conforms to
all regulations of the district in which it is located, except for expansion permitted under ACC
18.54.060(H). A nonconforming use, within a nonconforming structure, shall not expand into
any portion of the nonconforming structure.
Page 283 of 289
Chapter 18.54 ACC, Nonconforming Structures, Land and Uses Page 4 of 7
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
E. Structures which are nonconforming as to percentage of site coverage, setbacks, building
height or density shall not be enlarged unless such enlargement conforms to the regulations of
the district in which it is located.
F. Nonconforming residential structures are allowed to provide maintenance, alterations and
additions which may exceed the requirements of this chapter; provided the total number of
dwelling units does not increase and all other development standards of the district are
complied with.
G. This chapter shall not prevent the following provided the total value of the improvements,
over the lifetime of the nonconforming usewithin five years of the date of permit issuance, does
not exceed 50 percent of the assessed value of the nonconforming use as established by the
most current county assessor’s tax roll, except for the following items: ; and, the
nonconforming use or structure is not expanded except as allowed by subsection H of this
section; provided further, that any replacement of a nonconforming structure, or parts thereof,
must comply with the appropriate development standards unless a special exception is granted
pursuant to ACC 18.70.020:
1. Strengthening or restoring to a safe condition any nonconforming structure or part
thereof which is declared to be unsafe or a hazard to the public by the order of the
Community Development Director or designeea city official charged with protecting the
public safety;
2. Lessening a hazardous situation, nuisance or other adverse environmental impact;
3. Bringing the structure or use into more conformance with this title;
4. Adapting the structure to new technologies or equipment; or
5. Improvements which do not increase the intensity of the nonconforming use.
H. Any replacement of a nonconforming structure, or parts thereof, must comply with the
appropriate development standards unless a special exception is granted pursuant to ACC
18.70.020.
IH. A nonresidential structure or use which becomes a legal nonconforming structure or use
after the effective date of the ordinance codified in this title may may expand the existing use
or structure subject to the requirements of this chapter. be permitted by means of a special
Page 284 of 289
Chapter 18.54 ACC, Nonconforming Structures, Land and Uses Page 5 of 7
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
exceptionA legal nonconforming structure or use may be expanded administratively up to 10%
by the director or designee. Expansions of a legal nonconforming structure or use by more than
10%, not to exceed 25%, may be permitted by means of a special exception issued by the
hearing examiner pursuant to ACC 18.70.020 to expand the existing use or structure up to 25
percent of the use or structure existing at the time of the adoption of the ordinance codified in
this title; provided further, that the addition otherwise meets the standards of this title and
other requirements of the city.
This section does not allow the expansion of a use or structure which would be inconsistent
with a previously authorized administrative use permit, conditional use permit, special property
use permit, contract rezone, or binding agreement between the city and the property owner.
This section also does not allow the expansion of any nonconforming hazardous material
storage.
JI. When a building or structure is moved to another location it must then be made to conform
to the requirements of the district to which it is moved, unless specifically allowed elsewhere by
this title.
KJ. Nonconforming single-unit detached, middle housing, and apartments single-family
residential homes and their accessory structures may be replaced and the new structure shall
either meet the development standards of the district in which the home isdwelling unit is or
are located or the new structure shall not be more nonconforming than the previous use. All
other applicable building and fire code requirements must be complied with. (Ord. 6269 § 21,
2009; Ord. 5170 § 1, 1998; Ord. 4705 § 2, 1994; Ord. 4304 § 1(43), 1988; Ord. 4229 § 2, 1987.)
18.54.070 Abatement of nonconforming structures and uses.
Nonconforming structures and uses shall be abated if one or more of the following
circumstances exist:
A. If a nonconforming use is discontinued and changed to a conforming use, any future use of
the structure or land shall be in conformity to the regulations of the district in which structure
or land is located.;
Page 285 of 289
Chapter 18.54 ACC, Nonconforming Structures, Land and Uses Page 6 of 7
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
B. If a nonconforming use or structure is discontinuedAny structure or portion of a
nonresidential structure, or parcel of land occupied by a nonconforming use which or becomes
vacant and remains unoccupied for a continuous period of 180 days more than one year, it
shall not thereafter be reestablished or occupied except by a use which conforms to the use
regulations of the district in which it is located. The one-year time period may be granted an
extension of up to two additional years, one-year at a time. Extensions may be granted if the
subject property has no open code enforcement violations and if the property, including
structures, landscaping, and amenities, is maintained so as to not appear degraded relative to
the previous condition of the property nor detract from the surrounding neighborhood. A
nonconforming use time extension must be requested by the property owner within 90-days of
the expiration through a miscellaneous administrative decision application process
demonstrating compliance with the above stated maintenance criteria. Residential uses in
commercial or industrial zones which are unoccupied for more than 180 days may be allowed
to reoccupy if a special exception is issued pursuant to ACC 18.70.020;
C. The director or designee may administratively authorize the extension of a discontinued
nonconforming use or structure through as a Type I decision. Extensions shall be issued in one-
year increments up to a maximum of three years, subject to the following criteria and
conditions:
1. An applicant for an extension shall make a written request for the extension a minimum of
90 calendar days prior to expiration of the discontinued nonconforming use.
2. The director or designee shall in consideration of granting an extension find:
a. The property has no open code enforcement violations; and
b. The property, including structures, landscaping, and amenities, is maintained so as
to not appear degraded relative to the previous condition of the property nor detract
from the surrounding neighborhood.
CD. If a nonconforming structure sustains damage or destruction which exceeds 50 percent of
the current assessed valuation of the structure as established by the county assessor’s office.
Reconstruction of such damaged structure or reuse of occupancy shall conform to all
regulations of the district in which it is located and it shall be treated as a new building. This
subsection shall not apply to single-unit detached, middle housingfamily dwellings units, and
apartments. (Ord. 5170 § 1, 1998; Ord. 4229 § 2, 1987.)
Page 286 of 289
Chapter 18.54 ACC, Nonconforming Structures, Land and Uses Page 7 of 7
The Auburn City Code is current through Ordinance 7002, passed October 6, 2025.
18.54.080 Amortization and abatement of outdoor storage.
All outdoor storage yards that do not comply with the landscape and screening requirements of
Chapter 18.50 ACC which are located within an M-1 zone that are adjacent to a residential zone
or are visible from a public street shall, within three years of the adoption of this titleand make
any improvements included in ACC 18.54.060, shall screen and landscape the outdoor storage
pursuant to the requirements of Chapter 18.50 ACC, or the use shall be abated. (Ord. 6885 § 1
(Exh. A), 2022; Ord. 4229 § 2, 1987.)
Page 287 of 289
ACC 18.70.020, Special exceptions Page 1 of 2
The Auburn City Code is current through Ordinance 7008, passed November 17, 2025.
18.70.020 Special exceptions.
A.Only the following special exceptions may be granted by the hearing examiner after a public
hearing is held pursuant to ACC 18.70.040:
1.Platted lots within the same block and same zone, but separated by a public alley, may
be used as a single building site for the purpose of calculating the number of dwelling units
permitted in a structure to be erected on one side of the alley, subject to the following
requirements:
a.Each portion of the property shall abut a minimum of 100 feet upon the alley.
b.The two portions of the property shall be directly opposite for a distance
representing at least 50 percent of the width of the portion of the property not to be
occupied by the proposed building.
c.The portion of the property not occupied by the building shall not be sold,
segregated or used for building purposes so long as the building remains on the
portion of property on the opposite side of the alley.
2.Whenever there is a change from a residential use to a nonresidential use in an existing
building a special exception may be issued to exclude the fioor area within the building,
that cannot be effectively utilized by the proposed use, from the off-street parking
requirements.
3.A nonresidential structure or use which becomes a legal nonconforming structure or
use after may expand the existing use or structure subject to the requirements of this
chapter. the effective date of the ordinance codifled in this title may be permitted, by
means of a special exception, Expansions of a legal nonconforming structure or use by
more than 10%, not to exceed 25%, may be permitted by means of a special exception to
expand the existing use or structure up to 25 percent of the use or structure existing at the
time of the adoption of this title; provided further, that the addition otherwise meets the
standards of this title and other requirements of the city.
This section does not allow the expansion of a use or structure which would be
inconsistent with a previously authorized administrative use permit, conditional use permit,
special property use permit, contract rezone, or binding agreement between the city and
EXHIBIT 3
Page 288 of 289
ACC 18.70.020, Special exceptions Page 2 of 2
The Auburn City Code is current through Ordinance 7008, passed November 17, 2025.
the property owner. This section also does not allow the expansion of any nonconforming
hazardous material storage.
4. Pursuant to ACC 18.54.060(G), a special exception may be issued for the replacement of
a nonconforming structure or part thereof which does not comply with the appropriate
development standards.
5. Pursuant to ACC 18.54.070(B), a special exception may be issued for residential uses, in
commercial or industrial zones, to reoccupy if unoccupied for longer than 180 days.
B. In considering applications for special exceptions, the hearing examiner shall consider the
nature and condition of all adjacent uses and structures, and no such special exception shall be
authorized by the hearing examiner unless the hearing examiner flnds that the authorizing of
such special exception will not be materially detrimental to the public welfare or injurious to
property in the zone or vicinity in which the property is located, and that the authorization of
such special exception will be consistent with the spirit and purpose of this title. In authorizing a
special exception, the hearing examiner may impose such requirements and conditions with
respect to location, installation, construction, maintenance and operation and extent of open
spaces in addition to those expressly set forth in this title as may be deemed necessary for the
protection of other properties in the zone or vicinity and the public interest. (Ord. 6269 § 24, 2009;
Ord. 4840 § 1, 1996; Ord. 4229 § 2, 1987.)
Page 289 of 289