Loading...
HomeMy WebLinkAboutITEM V-C-5 CITY OF AUJ~ ~,. WASH[NGTON AGENDA BILL APPROVAL FORM Agenda Subject: Date: Task Order T07-005 to Annual On-Call A reement No. AG-C-225 Ma 30, 2007 Department: Attachments: Budget Impact: Planning Task Order BCRA-T07-005 and BCRA Pro osal Administrative Recommendation: City Council approve Task Order T07-005 to the 2007 Annual On-Call Consultant Agreement No. AG-C- 225 with Architects BCRA. Background Summary: BCRA will conduct Phase 1 of the space needs study for City Hall and the new Annex. Per discussion of BCRA's proposal during the May 21, 2007 Finance Committee and Municipal Services Committee meetings, only Phase 1 will be authorized at this time. Phase 2 will only be authorized at such time the Council gives its consent to proceed with the City Hall design work. L0604-2 A3.16.6 Reviewed by Council & Committees: Reviewed by Departments & Divisions: ^ Arts Commission COUNCIL COMMITTEES: ^ Building ^ M&O ^ Airport ®Finance ^ Cemetery ^ Mayor ^ Hearing Examiner ®Municipal Serv. ^Finance ^ Parks ^ Human Services ^ Planning & CD ^ Fire ^ Planning ^ Park Board ^Public Works ^ Legal ^ Police ^ Plannin Comm. ^ Other ®Public Works ^ Human Resources Action: Committee Approval: ^Yes ^No Council Approval: ^Yes ^No Call for Public Hearing _/ /_ Referred to Until _/_/ Tabled Until _/_/_ Councilmember: Cerino Staff: Osaki Meetin Date: June 4, 2007 Item Number: V.C.5 AU$U~'.N * MORE THAN Y4U IMAGINED ANNUAL CONTRACT TASK ASSIGNMENT DOCUMENT AGREEMENT #: AG-C-225 CONSULTANT: BCRA TASK #: BCRA-T07-005 PROJECT #: Interior Space Planning for City Hall and Proposed Annex The general provisions and clauses of the Agreement referenced above shall be in full force and effect for this Task Assignment. Location of Project: City Hall and Proposed Annex Maximum Amount Payable per this Task Assignment: $34,240.00 Completion Date: August 17, 2007 Scope of Work: Conduct Phase 1 of the Proposal for Interior Space Planning for City Hall and Proposed Annex, dated April 24, 2007. See attached. Approvals: Consultant Project Manager: Signature: City Project Manager: Signature: City Mayor: Signature: Date: Date: Date: Page 1 of 1 0 V Z W a u 3 n P d n April 24, 2007 Mr. Mark C. Ellingson Facilities Manager City of Auburn 25 West Main Street Auburn, WA 98001 Re: Proposal for Interior Space Planning for City Hall and Proposed Annex Dear Mark, Z 0 Z "< Thank you for selecting BCRA to assist you in assessing the City of Auburn's space needs. We enjoy working with you and look forward to developing a project that meets City design and budget needs. This fee proposal is being presented to address the City's need for space planning in anticipation of preparing an RFP for a new mixed-use building with a potential sky-bridge connecting to City Hall. I have outlined a~ more detailed scope below. Scone 0 W W Z a 0 N Based on our meeting with you and several Department Directors on Friday, March 30, 2007, we understand the scope of this project to include identifying/documenting the anticipated space needs of several departments in a future proposed Annex Building to be located across from City Hall. In order to accomplish this task effectively, it is important that two additional steps in support of, and prior to, planning for the Annex. First, in case this has not been done, we suggest each Department project out their staffing needs for the next 7 to 10 years in order to account for current and future anticipated growth, particularly with the pending Annexation process. Second, we are recommending a thorough space needs analysis be performed in the existing City Hall before any space needs assessment or planning occurs for the Annex. Performing these two tasks will help establish a clear understanding of how much space will actually be absorbed by the various City Departments over time and how much space will truly be needed in City Hall and the expansion. BCRA ARCHITECTURE • C1VIL ENGINEERINv • STRUCTURAL ENGINEERING • LAND USE PLANNING • INTERIOR DESIGN • GRAPHIC DESIGN Phase 1: Pre-Design/Space Planning The process for preparing the study and corresponding is outlined briefly below: • Meet individually with the Department Director or representative from each department currently in City Hall and any that will be included in the City Hall or Annex after the new building is completed to discuss current/future space needs; • Collate and document data from all meetings into Space Data Sheets (example attached) which are then used to Program Data Sheets (also attached). The Program Data Sheets, in some form, will likely become a part of the final RFP; • These data sheets will result in a basic diagram comparing F~cisting Spaces to Program Spaces. This graphically depicts and summarizes how much space will be required based on the data provided at this point. This is also the basis for bubble diagrams that will be provided during the next step; • Once the basic space requirements per Department are captured, a roundtable meeting with all Department Directors or representatives will be held to discuss adjacencies and where specific departments/functions need to be located. This may be facilitated through the use of a Space Puzzle Board where all spaces are provided on loose pieces scaled to the appropriate size and, through an interactive meeting process, each representative moves the pieces to where they think adjacencies need to occur. This information will be collected and depicted as a bubble-diagram; • The space data sheets provided earlier will yield enough information for BCRA to prepare typical office/workspace layouts (Space Relationship Diagrams) for each department and/or function (we anticipate one (1) typical office layout, one (1) typical workspace layout and, where relevant, a typical counter layout); • Once typical layouts are created and adjacencies are ident'rfied, we can estimate load factors for areas such as hallways, corridors, chases, storage closets, restrooms, etc. resulting in the projected space needs for both City Hall and the Annex. At this point, the City will have a comprehensive set of documents containing information necessary to present the City's needs in the RFP, as well as begin the planning process for renovating the existing City Hall. This process is anticipated to take approximately 6 - 9 weeks depending on availability of staff for meetings and response time to requests for additional information from the Design Team. Phase 1: Pre-Design/Space Planning (Fixed Fee) $32,240 Phase 2: Schematic Desicn It is our professional opinion that the space planning process will be more efficient and more accurate if the City launches right into the Schematic Design Phase of the City Hall renovation. Performing Schematic Design immediately after the Pre-Design/Space Planning phase is more efficient in time and resources since the information is fresh and relevant, we are able to provide the Cfty with a greater level of assurance that what is expected of the existing building can actually be achieved. This phase will involve actually laying out each of the floor plates with offices, workspaces, counter areas, restrooms, stairways, hallways and corridors, and also make sure any future bridge connection is adequately planned for at the front end of the project. This will also provide enough information to gather preliminary cost estimates for the portion of work within the City Hall. This portion of work will be finished within 3 - 4 weeks of the completion of the Pre-Design phase. Phase 2: Schematic Design -City Hall (Fixed Fee) $18,500 Qualifications/Exclusions: The following services are excluded from our contract: 1. Designing to LEED standards is highly encouraged and can be included in a revised proposal if the City is interested in pursuing this as a design option; 2. Schematic Design (Phase 2) is limited to the design of the floor plan only and does not include any work associated with interior elevations, selecting finishes, selecting cubicle/partition systems, reflected ceiling plans, etc. These services can be provided at any time through an addendum to the contract should the City wish to expand the scope of the project; 3. Fees for structural, mechanical, electrical, plumbing and civil engineering design services are not anticipated and excluded from this proposal. If it is determined that these services are required, we will contact you prior to proceeding and amend the task order accordingly. 4. The Contractor or an independent cost estimator will provide cost estimating services for the total cost of the project: This is not currently included in the proposal but we can assist in selecting a cost estimator. Compensation Basis: If this is not a part of the On-call Services Agreement, our standard project terms will apply. The fee for our services will be charged using a stipulated sum (fixed fee) for basic architectural and interior design services. Services outside the scope of work shall be approved, in writing, prior to proceeding with the additional work. Estimates of the costs associated with additional work will be provided prior to approval. Reimbursable expenses are estimated at $3,000 and are in addition to the fees referenced above. These include costs for reproductions, mileage, postage, photography, long distance telephone charges, permit/plan check fees, and incidentals required for preparing the products of this service. The City is only charged for actual cost plus 10% for handling. Progress payments shall be invoiced monthly and are payable within 30 days of receipt of the invoice. Unpaid invoices will be assessed a finance charge of 12% annually for each month or portion of a month an invoice is unpaid. If this proposal is acceptable to you please sign and return one copy to us and I will prepare a formal contract. We will commence work upon receipt of the signed contract and task order. Thank you, Mark. Please call with any questions. Sincerely, Accepted: Todd J. Wolf (sigNdate) for City of Auburn Project Manager Attachments o> y 9 $ $ > a 6 ~ C $ ~ 3 ~ ~ 3 3~ $ ~ 3 ~ ay 3 ~ ~ ~ ~ K ~ € ~ m 3 s G .. f~ ~s o Q ~ ~ ~ ~ n a ~ ~ ~ ~ z vi ~ ~ a ~ 8 '> r N Q 8 pAp Ap A v Mpp pip 0 H H H 0 0 pA O pA ap O O pPp S O pA H pP P 0$ pP pP 0 0 Op. pP 0 0 pP pP 0 0 fpl p Np 8 H 0 y O "'~ O VV ~ m tNi pqp Ppp p Np p+ 8O o OH P ~ H O O O O O O O ('~ {{~~Y] Y~ "'~ i r ~ ~ 8 4 ~ C p~ ^ C ~ 3 Y 2 8 $$ 0$ $$ $ 8 =~~ 0 ?° W p A p p N 8 H O O $ AA H H S Gq g p m p A H H p H p H H p p $ H p p $ H p H pN ~ p N $ S H a.~~ ~ , s ~~ ~~ ~ a N y Jm NAAOR S >m Ci Np~Y W Ci 1J N Ii PpS 1.t w1 IS Ci CiO AmAO ~~[" S ppp O O O g 0 g N N N N N M N N N N N M N N N y N N N Ng' N M N N N N N N N y' M ~~~~ e 'b 'ti G7 ~~~~ ~~;~z ~~~ 8~ ~~ ~ ~o ~:a C 8 ~, .. ~ . ~~~ b S ~~ as c Xa,~~/e SPACE DATA SHEET Dapartrnent! n Space: ~ . Occupants: 7 -3 ~~ lbursotUse 8hsire/dam Ulawe/aYy ~IlOent~l~ NoiaedOpereElon eno~aeroay flharxe/dey ~I bOUla /day MECFiMYCAL Tempaabue M~ +l~Y'F 68'-73'+F1 F sr-~B•+f z~ IMcaiditlaisd fpMBOVfY 50%+/~Y09i iAxmtrolbtl 07rr AiRBUPPLY i5ARCliapaRbir fONrClagealHar 5 A6'dwrga?1dr fo0% 6lelreap Air IbdraVdodAlr A-ProesaePoelEh~ AirPrsame NsydM A6 FibaYorJStpyly AlrFdBsYsrvF.d~ausl Potable 1# Wslsr (HW) PbEable Cold Wabar(CW) P~dRedWaM(PW,Dn CbAled Wafer (CNW,StR) • 0 a a a 0 0 0 • n a a a a a O a a a 0 0 Eucrrncu 110V 2M,1 Phaa • 108V, 3a, f Phew a T081; 3W, 3Phas o IBDV, f00q J Phaea a bafaledliiarxlOutla! 0 F.mapanayPowar a UPS(QFGf-PfiE) a Plans • oem • OOppYWYSbIWOfLIQ~ O DsyYQld3eraorLfph• a MrUa/CauBanlrnhbt o faskLlphCig • Lfyl~ltm Level (FaofrarxNee) f00fC~7aNtAroa o T6 FCA reekAroa • ~®J~M o IJyh1(XnaNUS a ~ o ~ Lbhbt a AMrI~leLlyhNglaae a ~. Fbar VIn)dCompakeTAe(YCr) a Caryel(CP'n • SealedCauo~sEe(CCNC) a i~ SIaWY l (B V ) o ~ , y ~ / ~p EpaRr"„"^71" 1(~ a HerdiwodFbalrp fWDI a Cerasrc TBe (C~ o abet a Bas r vinyl • WaadBar(WD) o Coved Hass (lnlepraQ a 4iter(ar WadPe~ltlona G~ppxnWaOBasid(GWB) • Plyaoad/ADO/CB1sr a WiNPielVpi EpmyPakd o PeRat • Aoau0alPabdc a 7adrarWh'EalAx(ace a we. Cearelc nla (ICT) a (~) P~am~FftP a 0@ar o ' Ce~P Oyan a 6oLd/Pa~f (GWB) o Doava 9'-0' x T-0' • 3~6'xT-0' o PR 3'-0'x T-0 (8'edde) a 3~8'x T-0' (T wlds) a ~_M)x_f-4 0 /iefbMig~Pfalo4bDoar a 1RNon Panel b • Abva6leEqugmerA AompAe- • Pri~hr • Pb1er a CgpyMeddne o PaxAfaahhe o Blxeddx a fbgsls BN o GoGgpe Bh a 0!•I0I a Frenibee r_LLkNra s Lrw. ~f_Ceelr /_~ FiYr t fb. r 0 1 ~eY Y l,-,,,SAar F 3~ f LoewCabFrb #_l~erGatixMe ~OBwr ! O/ler Vihida i! ~„Vsplde • • • 0 0 a 0 • • a a a • • ~x ¢~,p/e /~, Program Data Sheet BCRA~ ProgramlSpace Name: ' -' " "' Net Area (Sq. Ft): Department:.'' • - '"' -~ Quantiq-:1 Date: Existing Net Area (Sq. Ft.): ~~.. --- A.Function of Space G. Security Requirements Space Identiflcatron - Room/Type: Locking door Flexible use classroom H. Mechanical Activity Description: Plumbing: N!A Workshops, educaflonal classrooms; GED Preparatlon HVAC: Forced Air heating and cooling; ability to control after Time o/Use: hours. (Seek consultant recommendations). M-F 7:30am-7:30pm B. Occupancy Information 15 students 2 instructors C. Proximity Requirements Adjacent to: Quiet areas Convenient to: Restrooms D. Furniture and Equipment Requirements Tables (collapsible) Chairs (stacking) Podium Bookshelves • PowerPoint DVD VHS WIFI Access Printer (4) Computer stations Whiteboards Phone E. Storage and Casework Requirements Equipment storage Bookshelves • F. Acoustical Requirements NIA Other. I. Electrical Requirements Lighting: General low glare overhead dimmable Gghling and task lighting; accent fighting. (Seek consultant recommendations). Power.120v: Convenience receptacles at 12'-0'. Data /Communications /Signal: Telephone, CAT 6 datalcrom receptace; speakers for budding sound system; wircess transmitter within range (Seek wnsuttant recofruneridatron). Video: VHS; DVD; PowerPoint; LCD Projector; Smart Board; Big Saeen; WIFI; (2) Computer stations; (1) Printer Other. J Special Flnishes Considerations Floors: Carpet flooring and base Walls: HLR paint (high Nght reflectance); wall mural Ceilings: Awustical ceiling system IMndow/ i7eatment/Glare: Window coverings; black-out capabtiity !C. Special Considerations 2106 Pacific Avenue, Suite 300, Tacoma, WA 98402 P: 253-827-4367 F: 253-62T-4395 ~xa~~o% IS~DaG ~P~1C~ ~ o ~49~OO~d'~ S~ :~~ `~ V~..~- .,nWrl. ~6Xi1D',' ~ ' K LWOM]b z.' Y S :e37! ,~• .' pI~OGRAY 3PACE3: 82,000 SF Y ~p ~ ~ ~~ ~ ~ti • ~ 0 ~ g~ ~ ~ ~~ ~~ ~~ ~ SPACE RELATIONSHIP DIAGRAM" Space: F ~m ExtsUng Area: Future Area: •Abb-?hb~peddgamlraanFwbnYadbea'6r6Efedepraai' WMtlwhrdn~d•alr~aYkYdwdl-iQ~rnigrwenb o 1 s • • a gpddahYairl~o~rAh~pdb?rolailia~, a~ pu~n~rd0~~~~aP~pP'~ ~~7h mbdtlief prd~n o/tlingorarriihdJdrrgeAAgMSdieerkOufp~nDewb~w~Oti~a~~