Loading...
HomeMy WebLinkAboutITEM II-H AGENDA BILL APPROVAL FORM Agenda Subject:Date: Consultant Agreement No. AG-C-374 July 27, 2009 Department:Attachments:Budget Impact: Public WorksBudget Status Sheet, Vicinity Map$ 0 Administrative Recommendation: City Council grant permission to enter into Consultant Agreement No. AG-C-374 with Carollo Engineers for Engineering Services for Project No. CP0909, Academy and Lakeland Hills Booster Pump Stations Improvements. Background Summary: The consultant will provide engineering design services to update and/or replace two existing water pump stations in the Academy and Lakeland Hills water service areas in order to meet fire flow demands and to provide adequate domestic water service, as identified in the 2001 Comprehensive Water Plan and the Draft 2009 Comprehensive Water Plan. The new proposed Academy Booster Pump Station will be sized to provide approximately 300 gallons per minute (gpm) domestic supply, 1,500 gpm fire flow supply, and will include emergency power. The existing Lakeland Hills Booster Pump Station Facility will be modified or replaced to provide approximately 500 gpm domestic supply, 3,125 gpm fire flow supply, and will include emergency power. Both booster pump station facilities will contain station monitoring and controls that will be compatible with the future proposed SCADA improvements. The consultant’s scope will include pump station alternatives evaluation, hydraulic modeling, preliminary design reports, detailed design, and construction assistance. Environmental permitting and any right-of-way negotiation and acquisition will be handled in-house by City staff. Carollo Engineers has been selected to provide the Engineering Design and Construction Assistance Services for the above referenced project. The not to exceed amount for this agreement is $978,800. The budget for this project is contained within the Water Repair and Replacement 430 fund. W0803-7 Reviewed by Council & Committees:Reviewed by Departments & Divisions: Arts Commission COUNCIL COMMITTEES: Building M&O Airport Finance Cemetery Mayor Hearing Examiner Municipal Serv. Finance Parks Human Services Planning & CD Fire Planning Park Board Public Works LegalPolice Planning Comm. OtherPublic Works Human Resources Action: Committee Approval: Yes No Council Approval: Yes NoCall for Public Hearing___/___/____ Referred to _________________________________ Until ____/___/____ Tabled ______________________________________ Until___/___/____ Councilmember:Staff: Wagner Dowdy Meeting Date: Item Number: : August 3, 2009 BUDGET STATUS SHEET Project No: CP0909Project Title: Academy & Lakeland Hills Booster Pump Stations Imp Project Manager: Ryan L Vondrak Initiation/Consultant Agreement Permision to Advertise Initiation Date: _________Date: July 27, 2009 Contract Award Advertisement Date: ________ Change Order Approval Award Date: ___________ Contract Final Acceptance The "Future Years" column indicates the projected amount to be requested in future budgets. Funds Budgeted (Funds Available) Prior YearsFuture Years Funding20092010Total 430 Fund - Water1,000,0001,900,00002,900,000 Total01,000,0001,900,00002,900,000 Estimated Cost (Funds Needed) Prior YearsFuture Years Activity20092010Total Design Engineering - City Costs25,00050,00025,000100,000 Design Engineering - Consultant Costs200,000450,000225,200875,200 Construction Estimate1,600,0001,600,0003,200,000 Project Contingency (15%)240,000240,000480,000 Construction Engineering - City Costs25,00025,00050,000 Construction Engineering - Consultant Costs50,90052,700103,600 Total0225,0002,415,9002,167,9004,808,800 430 Water Budget Status Prior YearsFuture Years 20092010Total *430 Funds Budgeted ( )0(1,000,000)(1,900,000)0(2,900,000) 430 Funds Needed0225,0002,415,9002,167,9004,808,800 0(775,000)000 *430 Fund Project Contingency ( ) 00515,9002,167,9001,908,800 430 Funds Required * ( # ) in the Budget Status Sections indicates Money the City has available. W0803-7A