Loading...
HomeMy WebLinkAboutITEM 3 PLT10-0010 Exhibit 1 CITY of Number of Pages 8 AU-BU AGENDA BILL APPROVAL FORM WASHINGTON Agenda Subject: Tolas/Dulcinea Preliminary Subdivision; PLT10-0001 Date: July 7, 2011 Department: Planning and Attachments: See Exhibit List Budget Impact: N/A Development Administrative Recommendation: Hearing Examiner approve the Preliminary Plat of Tolas/Dulcinea with redline changes to the Preliminary Plat drawings and conditions of approval. Background Summary: OWNER/ APPLICANT: James Tolas, dba Dulcinea Development REQUEST: The proposal is to subdivide approximately 1.45 acres into six (6) single-family residential lots ranging in size from 8,049 square feet to 8,297 square feet together with an encroachment tract and future development tract. The proposal also includes sanitary sewers and storm drainage facilities. No road improvements are required. LOCATION: SE 307th Place near 124th Avenue SE. The site is within the Northwest Section 9, Township 21, Range 05 (NW 9-21-05) in Auburn, King County, Washington. Parcel Number 0921059090 EXISTING LAND USE: Vacant COMPREHENSIVE PLAN Single Family Residential DESIGNATION: SEPA STATUS: SEPA was previously initiated and completed by King County Department of Development and Environmental Services (DDES) for the handling of 13,000 cubic yards of fill imported to the site and related short plat. The DNS was issued on July 18, 2003. This proposal is exempt from SEPA Environmental Review in accordance with Auburn's Environmental Procedures Code, ACC 16.06.060. Reviewed by Council & Committees: Reviewed by Departments & Divisions: ❑ Arts Commission COUNCIL COMMITTEES: ® Building ❑ M&O ❑ Airport ❑ Finance ❑ Cemetery ❑ Mayor ❑ Hearing Examiner ❑ Municipal Serv. ❑ Finance ❑ Parks ❑ Human Services ❑ Planning & CD ® Fire ® Planning ❑ Park Board ❑ Public Works ❑ Legal ❑ Police ❑ Planning Comm. ❑ Other ® Public Works ❑ Human Resources ❑ Information Services Action: Committee Approval: ❑Yes ❑No Council Approval: ❑Yes ❑No Call for Public Hearing Referred to Until /Tabled Until =T=_ Councilmember: Staff: Wagner Meeting Date: Jul 20, 2011 Item Number: AUBURN *MORE THAN YOU IMAGINED s e Agenda Subject: Tolas/Dulcinea Preliminary Plat; PLT10-0001 Date: July 7, 2011 Staff Report to Hearing Examiner The Comprehensive Plan designation, zoning designation and land uses the subject property and map showing the adjacent zoning: Comprehensive Zoning Land Use Plan Single Family R-5, 5 du/acre Vacant Site Residential North Single Family R-5, 5 du/acre Detached single-family Residential residences South Single Family R-5, 5 du/acre Detached single-family Residential residences West Single Family R-5, 5 du/acre Detached single-family Residential residences East Single Family R-5, 5 du/acre Detached single-family Residential residences - - - - - - - --1 3876390290 397639moo 3979390290 38!6659,0 °~10 0921L69097 m2,039m1 v 99765902ro 3, 76=2= 3976530260 g ~Y a al a{ qa 9A{ $ !.rj4 - 0921 '0.8,76 997639@90 ~ ~ ~ ♦0 6 B fl ~ 092,0391,2 '~1 g In 1 $ 7990670 092,969,23 S ~ ~ ~ ~ wnwsoe n 79797WM0 3976am32o ° 397699090 ^ 3979'.80900 g ~ =079050 71379mcT 1 g 059076 ~ ~ J M K r 307ENTRCT a PFF 0917 =0=2 421039@1 0921 009101 olas/Du of ea Preliminary Plat 0927019121 092100949 0921009168 092105945 0921039069 QZoning gp "-°Cl Light Commercial District 8 3 wz1939170 ■C2 Central Business District _TT_ ■C3 Heavy Commercial District CN Neighborhood Shopping District ®DUC Downtown Urban Center ■EP Environmental Park District _ I Institutional Use District :Lakeland Hills South PUD f ;ELF Airport Landing Field District :.M1 Light Industrial District ■M2 Heavy Industrial District i. IPl Public Use District ■ PUD Planned Unit Development R3 Residential 1 DU/Acre R5 Residential 5 DU/Acre R7 Residential 7 DU/Acre ■R30 Residential 10 DU/Acre 01120 Residential 20 DU/Acre :RC Residential Conservancy ■RMHC Residential Manufactured/Mobile Home Units ■RO Residential Office District ■RO-H Residential Office District (Hospital) ■TV Terrace View -UNC Unclassified Use District Page 2of8 r Agenda Subject: Tolas/Dulcinea Preliminary Plat; PLT10-0001 Date: July 7, 2011 Staff Report to Hearing Examiner FINDINGS OF FACT: 1. James Tolas of Dulcinea Development, applicant, represented by Hans Korve of DMP inc. has requested approval of a preliminary plat referred to as Tolas/Dulcinea. The proposal includes the subdivision of an approximately 1.45-acre site into six lots and two tracts. 2. A "future development" tract and an "encroachment" tract are being proposed within the preliminary plat. The future development tract is to be owned and maintained by the applicant, Dulcinea Development, and later divided through a plat alteration or subdivision application filed with the City of Auburn. The encroachment tract is meant to carve out an area from their proposed subdivision that has historically been used by another property owner. The applicant intends to convey the tract by separate instrument to the owner(s) of lot 44, Kingsley Meadows, vol. 219/19-23, upon the recording of this plat. 3. The six lots will be used for single family detached homes. Lots sizes will average 8,228 square feet in size. The smallest lot size will be 8,049 square feet. The density for six single family lots on 1.45 acres is 4.1 dwelling units per acre. 4. The subject property is zoned R-5, Residential 5 du/acre. The proposed use is consistent with the R- 5 zoning designation within the Auburn City Code (ACC) Chapter 18.07 as well as the Comprehensive Plan designation of Signle Family Residential. 5. The subject property is panhandled in shape. The site consists of approximately 1.45 acres of undeveloped property bounded to the north and west by residential development. The site is bounded by roadways to the south and east. Existing site grades vary in elevation from 434' near the SE corner to 422' near the NW corner. The site slopes to the NW. 6. No dedication of land for park and recreation purposes is required pursuant to City subdivision code requirements (ACC 17.14. 100) since the plat is fewer than fifty dwelling units, the level at which dedication of land is required. 7. The adjacent public street bordering the plat, SE 307th Place, is fully developed and thus no off-site improvements are the responsibility of this development. 8. Water and Sanitary sewer service will be provided by the City of Auburn. 9. No state or federal candidate threatened or endangered plant species has been identified on the site. 10. Pursuant to ACC Chapter 15.74 and City of Auburn Design Standards, a temporary erosion and sediment control plan is required to be approved and implemented on the site prior to and during site development. Potential significant adverse environmental impacts associated with erosion and sedimentation from this development are adequately mitigated through compliance with this regulation. 11. Pursuant to ACC Chapter 13.48 and City of Auburn Design Standards, a storm drainage plan and subsequent installation of an approved stormwater management system on the site is required. Potential significant adverse environmental impacts associated with increased stormwater runoff from this development are adequately mitigated by compliance with this regulation. 12. To mitigate noise impacts associated with the proposal, all construction shall comply with ACC 8.28. Page 3 of 8 r Agenda Subject: Tolas/Dulcinea Preliminary Plat; PLT10-0001 Date: July 7, 2011 Staff Report to Hearing Examiner 13. The applicant shall mitigate school impacts through the payment of the school impact fee in effect at the time of building permit issuance. 14. Fire impacts generated by the project are mitigated through payment of the fire impact fee in effect at the time of building permit issuance. 15. Utilities will be provided to the site as follows: Storm Drainage - A private drainage system is being proposed to collect runoff. Runoff originating from the lots will go into individual infiltration trenches located behind each future home. Runoff that doesn't infiltrate into the ground will be conveyed to a drainage ditch along the rear portion of the development. Any runoff that enters into the drainage ditch will be sent to a catch basin at the Northwest end of the development and enter the storm management system that was built for Kingsley Meadows. Water - Currently an 8-inch water main runs south of the Applicant's parcel from which four (4) water service connections enter the site. The existing water services are the result of an earlier project (i.e. four duplexes) that was never completed by the Applicant. The Applicant is proposing to use the existing service connections and add two more. In order to service lots 1 and 4 private service lines extending from two of the existing service connections are needed. Private easements will be provided over the affected lots. Sanitary Sewer - Currently an 8-inch sewer main runs south of the Applicant's parcel. As a result of an earlier project that was never completed at the site (i.e. four duplexes), an 8-inch stub from the sewer main goes directly into the parcel. The Applicant would like to install a new sewer main (from this stub) that will run parallel to the existing main in SE 307th Place. The city, however, does not want a redundant system where it would then be responsible for maintaining and repairing the additional lines and manholes as well as ensuring that access to the system via the easement was maintained. Instead the city is requiring that the sewer connection for each house be made directly to the sewer main in SE 307 1h Place. Utility and street design issues will be addressed during the facilities extension process (FAC) with the city. 16. The proposed encroachment tract was reviewed by Planning staff and the City Attorney office and was found to be unnecessary. The City prefers to handle existing fence encroachments through a note on the plat indicating that they are shown pursuant to RCW 58.17.255 and they are disclosed in the title report prepared by the title insurer after the filing of the final plat. Also, tracts as defined by ACC 17.04.385, are to be created and designated for a specific purposes. The proposed encroachment tract does not have a specific purpose, only that it will be conveyed to a different owner by separate instrument after the plat records. The project has been conditioned to remove this tract from the final plat and instead, insert a note about the fence encroachment. For reference, the definition of "Tract" is found below. ACC 17.04.385 Tract. "Tract" means a piece of land created and designated as part of a land division that is not a lot of record, or a street or public right-of-way. Tracts are created and designed for a specific purpose. Land uses within a tract are restricted to those uses consistent with the stated purpose as described on the plat, or in the maintenance agreements. Examples include but are not limited to stormwater management tracts, private street or alley tracts, tree preservation tracts, environmental resource tracts, and open space tracts. (Ord. 6239 § 1, 2009.) Page 4of8 l Agenda Subject: Tolas/Dulcinea Preliminary Plat; PLT10-0001 Date: July 7, 2011 Staff Report to Hearing Examiner CONCLUSIONS: ACC Chapter 17.10.070 provides certain criteria for approval of a Preliminary Plat: 1. Adequate provisions are made for the public health, safety and general welfare and for open spaces, drainage ways, streets, alleys, other public ways, water supplies, sanitary wastes, parks, playgrounds and schools. Staff Comment The proposed six (6) lot preliminary plat includes provisions for storm water, access, water, sewer, recreation/open space, and schools. All lots will directly access SE 307th Place, an improved street, and both water and sewer services are available within this road. Adequate provisions are made for schools through the payment of school impact fees at the time of building permit issuance. The proposed project of six (6) lots does not reach the threshold of 50 units for requiring dedicated park space as stated in ACC 17.14.100. However, the City assesses a park impact fee at the building permit stage of the project to address impacts to the City's park system by the project. Project review by all review divisions has found the project to be in compliance with City codes and the project approval includes specific conditions to ensure standards are met. 2. Conformance of the proposed subdivision to the general purposes of the comprehensive plan. Staff Comment Comprehensive Plan Elements The following section provides the text from the Comprehensive Plan and how the project is in conformance with the plan policies: Land Use Goal 7: Residential Development To emphasize housing development at single family densities, in order to reestablish a mix of housing types appropriate for a family oriented community, while recognizing the need and desire for both lower density and higher density housing appropriately located to meet the housing needs of all members of the community. Policy LU-17: Residential densities in areas designated for single family residential uses should be no greater than 7 units per acre. Objective 7.2: To designate land for the development of new single family homes. Objective 7.3: To promote the development of quality single family neighborhoods which relate the design and types of residential areas to important natural and manmade features. Policy LU-26: Emphasis shall be placed upon the manner in which the recreational needs of the residents shall be met in the approval of any residential development. Comment The project site is 1.45 acres. With 6 lots proposed, this yields a density of 4.1 dwelling units per net acre. Recreational needs of the residents are met through the assessment of a park impact fee at the building permit stage. The proposed project meets the density of the R-5 zoning district and land use designation of Single Family Residential and assists the City meeting its housing targets and growth management objectives. Page 5 of 8 r a Agenda Subject: Tolas/Dulcinea Preliminary Plat; PLT10-0001 Date: July 7, 2011 Staff Report to Hearing Examiner 3. Conformance of the proposed subdivision to the general purposes of any other applicable policies or plans which have been adopted by the City Council. Staff Comment Development plans and policies have been adopted by the City Council in the form of the comprehensive plan and the related comprehensive transportation, water, and sewer plans. The proposed subdivision conforms to the policies, maps and narrative text of the comprehensive plan as noted above in (2) above. The proposed application complies with the City of Auburn comprehensive transportation plan where it increases public safety with provisions made for sidewalk connectivity between adjacent subdivision. 4. Conformance of the proposed subdivision to the general purposes of this title, as enumerated in ACC 17.02.030. The purpose of this title is to regulate the division of land lying within the corporate limits of the city, and to promote the public health, safety and general welfare and prevent or abate public nuisances in accordance with standards established by the state and the city, and to: • Prevent the overcrowding of land; • Promote safe and convenient travel by the public on streets and highways; • Promote the effective use of land; • Provide for adequate light and air; • Facilitate adequate provision for water, sewerage, storm drainage, parks and recreational areas, sites for schools and school grounds, and other public requirements; • Provide for proper ingress and egress; • Provide for the expeditious review and approval of proposed land divisions which comply with this title, the Auburn zoning ordinance, other city plans, policies and land use controls, and Chapter 58.17 RCW; • Adequately provide for the housing and commercial needs of the citizens of the state and city; • Require uniform monumenting of land divisions and conveyance by accurate legal description; • Implement the goals, objectives and policies of the Auburn comprehensive plan Staff Comment The proposed preliminary plat meets the general purposes of the Land Adjustment and Divisions Chapter of the Auburn City Code. The proposed lot size meets the R-5 zone regulations of a minimum of 6,000 square feet per lot and an average lot size of 8,000 square feet. The minimum lot size is 8,049 square feet and the average lot size is 8,228 square feet. As mentioned under Comment 1, the proposed plat makes adequate provisions for water, sewer, storm drainage, and ingress/egress. Addressed under Comment 2 is how the project complies with the Auburn Comprehensive Plan. The proposed preliminary plat will develop six (6) single family residential lots providing housing for citizens of the state and city. 5. Conformance of the proposed subdivision to the Auburn zoning ordinance and any other applicable planning or engineering standards and specifications as adopted by the city, or as modified and approved as part of a previously approved PUD. Staff Comment The proposed project meets the regulations outlined in ACC Section 18.07.030. The lots are designed to meeting the following requirements: • Minimum lot width of 50 feet: Each lot is 50 feet wide, thereby meeting the minimum lot width Page 6 of 8 r T Agenda Subject: Tolas/Dulcinea Preliminary Plat; PLT10-0001 Date: July 7, 2011 Staff Report to Hearing Examiner • Minimum lot size of 6,000 square feet with an average lot size of 8,000 square feet: The smallest lot in the preliminary plat is 8,049 square feet and the average of all the lots is 8,228 square feet • The future single family residences will be required to meet the minimum setbacks and lot coverage outlined in ACC 18.07.030. The applicant is proposing to extend sanitary sewer into the development where a new main line, together with side sewers, is created off an existing sewer stub on the property. It is the applicant's preference not to cut and repave the road unnecessarily. The City's Utility department is seeking to have the individual lots connect directly into public sewer main in 307`h Place SE. This is based on how the proposed plat is currently configured where each building can be directly served by the existing public sewer main located in 307`h Street SE and for reasons of long term maintenance. Should the applicant's proposal be implemented the City's Utility Department will be responsible for maintaining and repairing the additional lines and manholes as well as ensuring that access to the system via the easement was maintained. While not explicitly prohibited by the City Design Standards, an unnecessary extension to the public system will place an avoidable maintenance burden on the utility. Based on the long-term maintenance implications to the City, as well as consistency with comments that were provided in the first and second reviews of the preliminary plat application, the project is being conditioned that the sewer connection for each house be made directly to the existing public sewer main in 307`h Place SE. The preliminary plat drawings have been redlined to show the desired configuration. 6. The potential environmental impacts of the proposed subdivision are mitigated such that the preliminary plat will not have an unacceptable adverse effect upon the quality of the environment. Staff Comment The site has been engineered and altered through prior grading permit with King County (Project Number L03CG178 and later 1-05G1021). Asa result of that permit, the project site was significantly altered by the importation of approximately 13,000 cubic yards of fill from the neighboring property and some additional off-site sources. This work was covered under SEPA with a DNS issued by the King County on July 18, 2003. Based on the prior SEPA threshold determination and applicable City design and construction standards, the project will not have an unacceptable adverse effect upon the quality of the environment. Also, pursuant to ACC 16.06.060 six lots is below the threshold for environmental review. 7. Adequate provisions are made so the preliminary plat will prevent or abate public nuisances. Staff Comment Adequate provisions are made so the preliminary plat will prevent or abate public nuisances. RECOMMENDATION Based upon the application, Findings of Fact, and Conclusions of the staff report, staff recommends that the Hearing Examiner approve the Preliminary Plat with redline changes to the Preliminary Plat drawings and the following conditions of approval: Page 7 of 8 ti Agenda Subject: Tolas/Dulcinea Preliminary Plat; PLT10-0001 Date: July 7, 2011 Staff Report to Hearing Examiner 1. Each lot within the proposed subdivision shall connect directly into the public sewer main in 307th Place SE. The applicant shall modify the conceptual utility plan to show that each lot will connect to the existing public sewer main in 3071h Place SE via individual side sewers. 2. The face of the final plat shall include a note that states direct residential access to 124th Ave. SE is prohibited. 3. The proposed encroachment tract (identified as Tract B) shall be removed from the plat. The applicant shall indicate on the face of the final plat that a fence encroachment exists and is being shown pursuant to RCW 58.17.255. Ex. Encroachment Note: "Existing Fence Encroachments have been shown pursuant to RCW 58.17.255 and shall be disclosed in the title report prepared by the title insurer and issued after the filing of the final plat". 4. A revised Preliminary Plat drawing and Conceptual Utility Plan incorporating all plat approval conditions shall be submitted to the City of Auburn Planning and Development Department prior to the submittal of any subdivision construction plans. Staff reserves the right to supplement the record of the case to respond to matters and information raised subsequent to the writing of this report EXHIBIT LIST Exhibit 1 Staff Report Exhibit 2 Vicinity Map Exhibit 3 Preliminary Plat Application Materials Exhibit 4 Preliminary Plat Drawings - original Exhibit 5 Preliminary Plat Drawings - redlines (City edits) Exhibit 6 Notice of Application Exhibit 7 Notice of Public Hearing Exhibit 8 Revised Geotechnical Report prepared by Earth Consultants, Inc. dated March 6, 2003 (for Kingsley Meadow, includes Tolas/Dulcinea property) Exhibit 9 Project Correspondence Page 8 of 8 Vicinity Map- PLT10-0001 Tolas/Dulcinea Preliminary Plat APN: 0921059090 'rr f Y F S Zc•-. 'i "a a«'v'.s q , t }xa"~ , 'r k"'p a6 q rl e r i e I a A t s _ . . $i i ^a N N-~ 09210,59090 w fi tij ' 'Y 1 e . N . . AA ~q . q ' N w 'h •y ~ - _ 3 r ~ r Y#. q ,',A.; r~ar ".c.Pnst #..q ' ~ Y s w Exhibit 3, Number of Pages 10 CITY OF * AUBURN ~ WASHINGTON Plaitiihig, Btdldhig, aitd COiiiiltttillty Depai'ti lelit MASTER LAND USE APPLICATION- PLANNING APPLICATIONS Project Name Tolas Preliminary Plat Uhf Date 092105-9090 Site Address NW 9-21-5 Parcel No(s) Legal Description (attached separate sheet if necessary) See attached Applicant Name: James Tolas - Dulcinea Development Mailing Address: 3618 Lakeridae Drive E.. Sumner WA 98390 Telephone and Fax: 253-222-1782 Email: jatr tolas comcast.net Signature: ` - Owner (if i~l ` re th it one attach another sheet) Name: Mailing Address: Telephone and Fax: Email: Signature: Engineer/Architecture/Other Name:DMP Inc. Hans Korve Mailing Address: 726 Auburn Wav N. Telephone and Fax: LAS-3.S,i-LLUU Email: hansa..dmo-inc.us Description of Proposed Action: 6 lot preliminary plat. One tract for future development. No proposed frontage improvements. All utilities stubbed to site. Storm water connection in NW corner. T Pe of Application Required Check all that Apply) Administrative Appeal* Rezone (site specific)* Area Wide Administrative Use Permit* Short Plat Annexation* Special Exception* Boundary Line Adjustment Special Home Occupation Permit* Comprehensive Plan Amendment (Text or Map)* Substantial Shoreline Development* Conditional Use Permit` Surface Mining Permit* Critical Areas Variance* Temporary Use Permit Development Agreement* Variance* Environmental Review (SEPA)* *Please note that public notification is Final Plat required. A separate cost is charged ✓ Preliminary Plat* for the signs. City repares signs but PUD Site Plan Approval applicant respons j1 pre, gs~ting. Reasonable Use Exce tion* V Page 1 oft t A t :AUBURN t, MORE THAN YOL1 IMWNED 4 CITY OF AIJBUR'N' WASHINGTON Plnnunhig, Building, pnnd Conummity Department LETTER FROM PROPERTY OWNER GRANTING AUTHORIZATION TO ACT (A copy of this letter must be submitted foi- each property owner involved) I, 'J , being duly sworn declare that I am the owner of the property (PROPERTY OWNER) Involved in the application. I hereby grant Hans Korve of DMP Inc to act on my behalf. I further declare that all statements, answers, and information herein submitted is in all respects true and correct to the best of my knowledge and belief. Signature C' 14 Date 40 C> V7 Lj,L S 3Address Ilk" Subscribed and sworn to before me this ay of Notary Public in and for the State of Washington, l- Residing at ~'~-,.,.~k.,.'1_si~lrF•.~-- Page 2 of 2 .A.UBURN =I< MORE THAN YOU IMAGINED CITY OF AUBURN oF> 1,cv oNL r ) or . * De artment of Planning, Building & Communit" Ac„mT~ p to 9 v FILE 1lU s U Auburn City Hall, 2ntl Floor ° WASHINGTON 25 West Main Street FILE NAME: ` y Auburn, WA 98001-4998 Tel: 253.931.3090 TYPE: ECEIVED BY: " Fax: 253.804.311481rCK/CASH: ~a 1;, permitcenier@auburnwa.gov FEE PAID: , at,°` mvw.auburnwa.gov SUBMITTAL DATE.= LAND USE DESIG: TYPE III PRELIMINARY SUBDIVISION (PLAT) APPLICATION APPLICANT. ❑ Use mailing address for meeting notification. ❑ Check box if Primary Contact COMPANY: ! th~ +r, Na K~) eue-l(op VM\/ i ADDRESS: 61 plc') IJ5 f-. 3E (CITY, STATE, ZIP) ` k w. t ns PHONE: ' 1I P51 FAX: E-MAIL: ~]c~weS7vlC SIGNATURE: PRINTED NAME: (Sig ature R wired) APPLICANT'S REPRESENTATIVE. V Check box if Primary Contact COMPANY: 1D v- C 1 11~ yt .S /"NO P V ADDRESS: -+2- 6 (CITY, STATE, ZIP) PHONE: Zae)ea FAX: 2.S3 E-MAIL: ~C+v1 S C..(w,a~l..rne ,rt_r SIGNATURE: _ PRINTED NAME: -77 (Signature Required) PROPERTY OWNER(S). ❑ Attach separate sheet if needed. ❑ Check box if Primary Contact COMPANY: ADDRESS: (CITY, STATE, ZIP) PHONE: FAX: E-MAIL: SIGNATURE: PRINTED NAME: (Signature Required) Note: Applicant or representative must have property owner's consent to file this application form in order for it to be accepted PROPERTY INFORMATION (REQUIRED) SITE ADDRESS: N LL) Z. t ASSESSOR'S PARCEL ID## LOT SIZE ZONING DISTRICT C-) 0%5 _ PROPOSED USE OF SITE:1 9 / ilt AREA TO BE DEVELOPED (s.f.): EXISTING USE OF SITE: G1Permil CenterAPPLICATIONS-FORMS\Planning Forms\2009 FORMSWfeliminary Plat_Subdivision_ AppForm_2009.doc 9/19/2009 3 Q. " jjBU CITY OF AUBURN PRELIMINARY SUBDIVISION (PLAT) AU WASHINGTON Department of Planning, Building & Community APPLICATION Auburn City Hall, 2`d Floor 25 West Main Street Auburn, WA 98001-4998 Tel: 253.931.3090 Fax: 253.804.3114 permitcenter@auburnwa.gov www.auburnwa.gov TYPE III PRELIMINARY SUBDIVISION (PLAT) - AUTHORIZATION LETTER FROM PROPERTY OWNER GRANTING AUTHORIZATION TO ACT (A copy of this letter must be submitted for each property owner involved) being duly sworn declare that Ira'm the owner of the property (PROPERTY OWNER) involved in the application. I hereby grant ~.h 5 n ve._ of 3,~ ` to act on my behalf. I certify under penalty of perjury declare that all statements, answers, and information herein submitted is in all respects true and correct to the best of my knowledge and belief. I agree to hold the City of Auburn harmless as to any claim (including costs, expenses and attorney's fees incurred in the investigation of such claim) which may be made by any person, including the undersigned, and filed against the City of Auburn, but only where such claim arises out of the reliance of the City, including its officers and employees, upon the accuracy of the information provided to the City as part of this application. I further agree that the City of Auburn staff may enter upon the subject property (ies) at any reasonable time to gain familiarity with site conditions and to take photographs and to post public notices, if applicable, Printed Name ? r u -n"& t ure Date Address 'TA Subscribed and sworn to before me this Cr' day ofQiA/)J)CAI. /61 r4tr ai . '4 Notary Public in and for the State of Washington, /6e- ~ld "at 5 n 2(~~~L [ r cJ~ «z,.r F fr rL~ f U j, ? d t G:1Permil CenleMPPLICATIONS_FORMS1PIanning Forms12009 FORMSTreliminary Plal_Subdivision_ AppForm_2009.doc 10119/2009 4 rnror CITY OF AUBURN PRELIMINARY SUBDIVISION (PLAT) DBUEZN A~~uc~°rION WASHINGTON Department of Planning, Building & Community .Auburn City Hall, 2e° Floor 25 West Main Street Auburn, WA 98001-4996 Tel: 253.931.3090 Fax: 253.804.3114 pemiitcenter@aubumwa.gov vnvw.auburnwa.gov TYPE III PRELIMINARY SUBDIVISION (PLAT) LAN SURVEYOR'S CERTIFICATION NAME OF SUBDIVISION. + 1 VA REGISTERED LAND SURV YOR (COMPANY) NAME (INDIVIDUAL) lz~e l z2 = S REET ADDRESS T LEPHONE CITY STATE ZIP -MAIL 1 k, i= ENGINEER (COMPANY) NAME (INDIVIDUAL) E5 STREET ADDR SS TELEPHONE ~p Z= CITY STATE ZIP -MAIL 1 1--i I APPLICANT (COMPANY) NAME (INDIVIDUAL) STREET ADDRESS TELEPHONE CITY STATE ZIP E-MAIL Land Surveyor's Certification Land Surveyor Seal and Signature I hereby certify that the accompanying plat has been inspected by me and conforms to all E M®~ rules and regulations of the platting resolution J~'oIwAsh `4p and standards for Auburn, t ashington. SIGNED 822962 DATE~_ C R'v4C HTIOK _ s E?NIalf an3n f am _Sublivis;on aappFwm_24N,doc, 1011912009 6 dmp, Inc. DALEY-MORROW-POBLETE,INC. ENGINEERING-PLANNING-SURVEYING 726 Aubum Way North Aubum, WA 98002 February 12, 2010 Elizabeth Chamberlain City of Auburn 25 West Main Street. Auburn WA. 98001 RE: Dulcinea (Tolas) Preliminary Plat Dear Elizabeth: As requested, I am submitting this Application Checklist response and Project Narrative to summarize our conversations and agreements regarding this project. Thanks for taking the time to work with me on this submittal. I wish all my project could be this simple. I am presenting each issue under its own bullet with a short description of how that issue is being addressed. As you know, having this project vested is our largest issue. Any item that we have missed or that I misunderstood will be addressed, as promised, with the first round of review comments. • Items A though G of the submittal checklist are present. • Item H -The Project is SEPA Exempt. • Item I - The Project will generate 6- peak hour trips and will take access from an existing street network that was recently constructed or improved by the Plat of Kingsley Meadows. SE 307th Place is a new public Street and ties into the existing 124th Ave SE. No traffic impacts are expected. As discussed, no impact analysis has been provided. • Item J - As indicated above, the subject property is surrounded by the recently completed plat of Kingsley Meadows. As part of that neighboring projects required improvements, sidewalks and other automobile and pedestrian improvements were completed in the area and extended to the intersection with 124' Ave SE. The Dulcinea Plat takes access from the newly constructed SE 307th Place SE and the six proposed lots will utilize the existing pedestrian facilities. The Plat of Dulcinea is located only one block north of Lea Hill Elementary School. The existing pedestrian improvements and manned cross walk along 124"' Ave SE provide safe walking conditions for school children. Please see the attached Arial view of the property for additional information. The Project is also only four blocks from Rainier Middle School which also has existing school walking route improvements. RECEIVED • Item K - Storm Water Report - Six sets are attached as requested. The Applicant proposes on- site infiltration for individual lots. } 7~ 13 2619 • Item L - No critical areas are present on the property. C;I'[Y ()F AUBu13 10-105 Dulcinea Preliminary Plat t i E ®Page 2 February 12, 2010 • Item M - Soil Report. A copy of the original Kingsley Meadows 2003 Geotechnical report has been provided. The sample pits are located on three sides of the Dulcinea Plat and are representative of the soils found in the area. A revised copy can be provided if required. • Item N - Water / Sewer Availability. The property is located within the City of Aubum. Sewer and Water service was provided to the property during development of the Kingsley Meadows plat. The property has 8 water meters and one sewer stub. Please see the attached plat map for additional information. • Item O - The property contains no restrictions. Please see the attached title report. • Item P - A pre-application meeting took place, but no not were available from Staff at the time of this application. • Item Q - Neighborhood Review Meeting. None was required. I • Item R - The Multi-family standards do not apply to this project. PRELIMINARY PLAT DRAWINGS • Plan sheets A through P have been provided. • Transportation Plan (G) - As previously indicated, this project has no proposed street system improvements and by its very nature is already integrated into the City's Comprehensive Transportation Plan. • Landscape Plan (H) - As previously indicated, the proposed project takes access from SE 307' Place as part of the Kingsley Meadows plat, 16 off-site street trees were installed in conjunction with the required road frontage improvements. Of those, 9 are located along the project frontage. Over the past 3 years, the Cherry trees have matured and are in excellent health. The trees are also matched in species and size to the adjacent street trees in the area that were planted as part of the Kingsley Meadows project. The City of Auburn requires the installation of planting strips along one side of new public streets. When SE 307 Place was constructed, the Plat of Kingsley Meadows installed a 5' plating strip with matching street trees along the south side of the road. Given these, facts, the applicant proposes to retain the existing Chevy Trees in their current location. No, additional landscape improvements are required or proposed. Phasing Plan (1) - The project consists of a single 6 lot development. No phasing plan is proposed. If you have any questions, please contact me at (425) 444-3240. Thank you for your help. Sin ly, 4S Korve, Planning Manager DMP. Engineering r.r.~n~~ ` T~' J ' f 1 ~~5144~'~ 111,,, ~~4 i ~-rJ J I f~fAuF':.S,IiF?)ih.4wi ~ Y t y, n1FPlSr' ~ ~ 1 r F t .T '7 sd t 1 T ~ ~y I GGjB rr~ ~ '.I t N~ Y Hp~ ,:I~~~~ Dulcinea Plat School Walking Analysis Lee Hill Elementary School ~i a 1 k~5'''y F.r~r ~tz~~?i ~t 9 P ~'c1~ ! I I 4s'~ ~il. Pt. t ~ ' r.r -111 III~Fl!~yFi~'Nr MIPA 4 ~ 4 M~Y 1"Y r "g, r r~ t llrJA ` 11J r.: a e M r 11 ~7 ~tiv f S k Y' I Nt1 ({r t CIE-1," I tt~r upr~i;~ de OItt ~1 I~I~ ~~'l~ll~~ r~ft~lw~''til~t~l~~ajti ~~~ecY r t S r~ 114f ! Y, 1. "MINI, 1 s ,k n .~d tl v }t. v~ Vg 1 Irsl ~L~,r i4 lSU •r 1 qg(,~~ r f ~f I - 1 1` ~f ~ 1 lsti~~~}t~vtiv +1`gii^'+ 1 Illy~•S~ fry~~H i •~,I, Ir14.f. I:plFf yr r...i+i YIw~ ~ rill~~, ' ~ 14 ~in te~elil ~ f` fr ~I 4 ~h S {}yt l~l~t'~~~i .v It i 2 e~l~.r Tl t~ tIJ E)r lE. II i ts~ ..L v ,reds _ i(. ie is r k 1~,~e 5 r e, ! Y.,ry~ i •ir Is' 7Fj h;i ~r A~ ~ Y `4 t J tiL I ~i 1 ~ il~ta ~1 !'w ~ til'~ I ~ ~ a~ tq i h , r JlyM1yr. I. Dulcinea Plat School Walking Analysis Lee Hill Elementary School Crosswalk lti.dr e,~;~~d. ~ f : ~ t - Sr ~•j~~j i y~ y-,. ~ u ~i i •s~ 5 f ~r u ~ , kv r:~• • ?~"5,~ F ~ ' f r ~ y ry `~U~r' Y da!(>~r it , 1. ~y 4 'w-. - iLL 'n~~. , Rn1411~y ~ ~ ~ r •ae~L~ l yr j~~ f, R ~ ~ y ,f~rv ~X ~ ~ r Vi . R in G~; mm T ~ „~v~,. S ''~i° ~ ~ wl,~ti,r, ~r,.~ ~ ~,iy ' r YNSl~ '~7 ~ ~ 11 i AI I~ryS ~ 1. i ~ { ~ J1i 1 ~ ~ f j ~ . m 1 ' l!- t ~l '~.tir%dh4'rC~[iki~" I°a ~i1~`-• m i '!Ii:J; , Dulcinea Plat School Walking Analysis Rainier Middle School Walking Route I � = PRELIMINARY PLAT OF ,. a DULCINEA S EXISTING GONDffON3 A POFTTION OR N.E. 1/4, N.W. 1/4;'SEC. 9. T-21N, R-�, W.M. ' ' CfTY OF AUBURN, KING COUMY, WA3HINQTON ; ��'� � �� 50 49 � .� A�O 1 m INGSLEY MEADOWS 4 . ' �m[� �. 4B - K . 219 -23 - WY��EIV d ' L / 9 - . IL��IS13 li'£ tl _. 47 � 15 I < J � IE.��149)iB F __�__ _ __.______ . __ _ - -_-_48 95 � � ' 4 VO _ � 3 . . gy ¢-uaed�e.s � I �� Q . _ ______ .ce ow m.0 mra¢c*m nws I ' �e 4' �s'n.s�c mi�:a[sa: �xaE wwr ro:¢ �rc so� _______'_ '�d�� � a ul� :.aua ? .. � �� 6Y49Fi1FYM5P/VIF� .k P@p�.y[��WR . C�RO 1�/JS/]CUp Kl]19/�}}] .f@ �.ep c.S s o�u.E �pxAE eoi�rua � Q w 1 1MRIOF r� - Z>..9f1}'TCOI�I�i ' �\ 4 . . �1' . . . . ' l- �� � N.1ttS1 31 � 1FI�.MVI1440.i- X11Y y. WIIMN� U Nl� . }IN R- j� I �ry /irn-`�i y..���FJ �F�'°—,i °'`� a t � F � ��� / � � o.w j� �m ' \� I� j -i- � d� 5� '�;` aR�ti= �`is`�3`�g. �'p l-1 1_ . r ' I 4 �} lu, tt W . � R� � � I � �J I ` ° � �---ue- -� i� � \ ` I I � �� . � ~ ZO 53 ` sr � � ' < Q> . �s �.. �� � � \ _ ._ _ -' �—J/ Ir � e"mxE �'>s- I p ��jN � �y�( �i'� `� ` a u�g xvr¢�/� ic�`��x.�/.. '� ` �Aaa�wu 1 i' // i��j z � -nx.i-x � � _ ' � �__"_"" '_"""_'__"�"'�� / �' \` _ l� /'s� S�F� � .F � �a - � _ f ., F� a?r � . 3 "e�\�. \\ / � � — ^/. ' — '� �� �I 3YF / \ no � \ / / _ � I� — � / � ' I a�a� O �y o O . �. / ` '��I a„� \ ��� I S, /_ _ `' �� i/ _ � ��a-. _ \ / / \— J P- n O 55 56 �� � — i � / / -� \/ ± Y.� � J2Pv - I O 0�p . N� . - 1''�/� �/ / \ ��' � \ . " w' M Nn � I , � � I I Y= I]'rsMdEW�• f�-�X✓ � /� \ ��I' ' , U . I I I ` / , y,�� rro f�xe;s w . I p . . r u¢w. ���,�mx+ L J ' >'ac ��osvx. ��occar >'�_ r osa+,.LC�c.. I ss us• 1. _ _:� . — _ _r ac�. I �\ ✓ . � :.,. ..-. _. . ,� ... k .. _. . , .. . . _: r . ,.. � -. , .. :c : ... . —. — , °°w — . .o ^ � , . . . .,' . � s-,.:�r �. �... .. wnw x r wz o-s� . — _ _ uYm � � . . . ` nL .ven rsuo�Siv w) � P„1�mre:.n a'�ss o-x - . 8� tf 5 � ,::K ,� ��...xe.aIXS) p w�roi�srv aaos.x' ��. G�v�°o�ti°i�o.s yg(1[ry A9 6 � 1 lF QMMR� \.1 Y� ��nl RA� �— Y � ' _ h/�LOR W . . nrv nx � s . .. ' . . A ce�rm[i . - � �oe� - 9�1 . . . RY�W bl . 5 NI��}195 . �- lE��p ' 1E•WI� IE��H� . . . TRACT °C ���yyi ( - ��'°`�°ar� ' KINGSLEY_MEADOWS � �M„ } �E��YJIE(5) VOC 219/19-23 . 4 TRAGT °D° TRACT "B" . � R yy � � ��� � � "p`e y k' � � g �y��" CffY OF AIIBUfiN APRiOVAL6 - - . j�07� . ¢ MrxpNll 8�I6NAVixJn_fF ME�lNilbl Pi�CWN0.IX� � LMnpIN4 OOYM�P�0�1�r�5��uKD Ov pP[R fRp MI.S1L�pi5[Y0.0N:0 ttwWalMUL W�Wi.Z ' . . . �}%1. �CC6V�ES 119K 1 1(Fp}1]110 MLIXAIR MM FRR.LL ET41Q YE�9RNC YEIFA.fiF10�Glt BY pB.INC � (0�2) M MI¢.LLL 12A9AF11Ex3 IAE H V S SllRKV IFEI. ,G . �!. PI.fiY NOlfmFii DTf f9iwv 6 1�9�wLldl nc 9JBdN4J1 tvKU'h2 PttA No ��WX4 0�1E0.uWaar . MSCRN.0.11XXG 40 CfH1WENi fE➢Mi�01i pM.YOI.1tlID4YG 1D 5�0 OIi1NNllFC 6 9L2C�N MF ME ff M INO ttMllSNE Mi5[1�E11NG LQUMYIS RLLOOlG.uN On(M.fft6LL El¢➢�.V6 . am�. �-xnml ra ur<um�.ue<nna�armrt uo rcaw.nw a cwaw�.ac xo.za000�amro�i. - . 19�I�IIF() (YIE/ . H Ulln�Sv5Rl1 FA4��l.IEG xu 1WlPMM0.UOT . . I'. . 91.lS$ �y14 � . � ' ���� �y�pp�yy�. C v�1LIX WR101!M WSE�1E'WR I.�]-Wµ4C Mu]C0�81MG11t . . 1��E➢Yo 9�1 � ' f'='�!�+�)11CII1� XO Wpy11i 61C12B1 YI.LC LV�24 Q1 YqRp.AS fil M KVIRICI Nq ry ppY;p [�p�, ��'�•��� • �H.w " ME WiM xllf Y M SNIx NNS R 11&SWMFISi M CpM14E1E165 6 Y1D W 4YNlEL. `Y�W�RU I18 1]) p� .. . .. . N�N'� ,�� I OJKIFA 6'dE KM11f�5i W/AIER T MF IIO1MrtSt. �0.�/A5 Cf MOK1R4 C�/Gg V �� CU4GlfR 6 SCI'M 0.i10Y19m T MUtM MfIR 5[Af�. ' . . (191ED 1WIFA UIE Ci YL� �F . . . �L.W F91f tpNtt.�446�GiOl � fAI�GWRU�Cl/� � b g . . � _ ' ucarxx���sn R s - !��M NFM II!iQi Q MC$WM%q iFLi 6 f1R 9Ab 6 MII I/�. . �M EASf SNl iFF�Ci LO�TEIS��IMfI@ R TIE � � ' � MWM�1F5�Q1M�P R S�D ffCLOk 9.BIY'A4J1�1Vp'1 p� - auNC ec.uM1E b �EC39'm . � KW.U4�8E{i.a T-a�1��,�i WM [�¢ 4O LIU➢1 M EAS�]0 fE£1 fPl f9Ntt Nd0 . +--a [Y.$1fb QA�fR1 9(FI�6� [CSGM14[ONIYWS 0.N1 RA ISi90 Q 91R�[f-SC.Ne.SS'lC]I3�I1 ��ti8 9�1 � �N�6T) • f)t�Irt914RA 9�1 3 fF♦ 4R 0.N1 SGIL 1'SD]' _ � , DA� ' ' 1 ImE�W M1 {C FY V>i(q V4K 9aET]Ci♦ CMLdNN IA/LqC RIN I - IY`.O E! ���y/��S � 6 4RM B/Sx-iNE II SXFFI�C(� CMfFpNLL UPLIi�P41X ' �� .. � }' OS Y��'ll L�M1 CPMEN15lEi1fA DI.RY�MlL]9.}0 . . �'A9�IKM1 5111E pMY NWM SfNE IiYil 65/BI � Ca L��p B19N-ME 1 I:' . . . . . . . . �� rtn�¢[vLl�F 9q�EV-RLC M fY6]MO�� . �3 u�P YO PiY CCYUFN3lEiRR U.1RD YrJN�4 f0� Q [C SWINY Y41 MQF I. �arc a�axw a�xi-ol wuo+n sv¢a rortn w��� a u iuc�ws wsEx Bff 81$T 2 OF 4 FOfl ADDIfIDNAL'NO7� .. ou+�wsi cwm a s an s+r�r uo�:sa��mac 2� BA918 OF BEAHQIQS � :m'•.°• � vil � 11H L 1I1.x 1L 1�.SC Y.i-i1K a-Y�Y. R RILAKI.F b4T � n.-��v ne a��rmw�rt a a uiurv vwE `[. DALEI'-MORRON!-POBLETE.'WC. il` � OI1LClEA OEVH.OPI�If.he. - N) ��9�� ' �,V WBUNN W/SII:NGTONN BBOU3 %IB V.4M'.GF M f/Si.�¢51Mp�1�I4 ffi]911 (AI M[W+'J Y SUA�Er � 1��i PNONE: (253S3J)-2200 (fP%)JJ]-t306 ! pp�E Na(}yJII3-1)B]_ _ _ R[C Ma.V%e]fsm� . � : �.lfNNV RAT OF � ' °�°°°� Q D �+o�"°rtnrac� �� o�°�o�n e. � . N ae-�.� .�- v'w r= �.. � �ma,� - ,e, t �^ �io�a'io io+os .! i I � . . . _ _ . . _ . . _ _ _ I I � PRELIMINARY PLAT OF �: ' DULCINEA �.,�s. s $r� �,N A PORTION OF r N.E. 1/4, N.W. 1/4, SEC. 9, T-21N, R-SE, W.M. � C(TY OF AUBURN, KING COUMY, WASHINGTON -�m�a u ' ' Q; s vom sr . �. 50 p9 . . I� g� � s��xw s� � O a ,c�, �m 4e � K�NGSLEY MEAOOWS 4 � � � I VOL 219/19-23 i P . . :. '. �i . i /�T Q� ' �H� , _ �e ' 47 46 45 6' i M�4l�� 44 lil �B� Jc� VI . ':R�S�P . �__ ___ '______ � aiRu E�Onq�uEH� 3n . _______"_______' sz ; _________' _ ' ��� sn _ v m n �s'xa�c aun+a c:van'__'_� � � ' . .����} oni SEE NOIE ] z�unn - � � � , ���� IHIS 91EE1 BELO'N yp�vu���p¢ � F Q� � i � i � f 50 . i �vf.��� 6YN6wc., . t , NV 10'L e 50� n )J � •���w p Q'�i]( R W S 1 8 1 � 1(1 (NY 1 A YG 9.I-M R-X�Y . d I�F ¢ U tl i _____ _______ ' 19I' . ° aw w y Q R � V .I____'__r r_'___'r _______ _______ oawaayvn�" r — — � � ru�EAo[���( . � :� � ?Q 1 �-- u.nz s: � s' C;� I � I � i � � I � � i � i sce uore i nais s�+ccr ec�ow �I�' rc ��k � -y� � I I I I I M x W.S.m's 1/�.ra 1/4 na 1/�. - �� C I I I I � J � �Y. 4G9.1-TN.P-Y.�IL ' � � � I � � � � � i 'k 4 � ?- � E � � � I � � � � e � �4: ------- ------------------- � ' _ � `a � m � e.zv2sr3 I � e.z3sv: Im I 4 - � I 5 - �� � 8 I �'i 3�'i �� �y '� B.]9� SFS I n � 8.296 S's m � 8.019 Sft ^ }I : . 3� n n 6Y I I I I� I I� I I I I9 I 8.1335�5� In `a; •q>. �O al tv 00 . � � P F n0 55 Sfi q�l p Oj.0� �a I � I I I I � j � � I � :"i � ��°v � I � „^ Fon crtr usE orir _ i � I I � I � � � � I � ��� � x� I�L �, �� � � I � � � ' � � � � _ �n's' � 3 I W b y � _^ K --'- _ �-----t-�--- � fy-- � ��� � J ¢�cmcucumm�r a _]______ __ _ _ 5p� �___ - I-'__ _ _______f 1______J I ucrm.emoxe - 5a___ ___50. . rv �40�x��'� �avvsm e'auvnre 50' �p. 0 2t,I ro�m i ro�or�'i`�� 'ur"�'un°gi suw°i� — _ — _ Qx�m i°isvE��°i�W`flt"6�[ tl . . — _ __ ' __ _ _ _ _ ' _ _ . � # . . !J — _ — _ � _ � ' � _ _ . - BE80MRACE — ' — A 6 5 TRACT "C" KINGSLE`! MEADOWS 3 ' VOL-219/19-23 < 1RnCT "D� TRACT �B" . ' � g _ BffE R�FO(dM7plt �DBIML TABLE � [vi�PHC eG1te . g.�,�g�pryEypp M+-ya�s.w-waza.xc. R1pI'�LAlm UBE mm�ruar x.�aa : w o �s n w . ' �isna.u�a«c+a veaoz ('�1�-lf00(fI313ll-3Mk �R� �8 ! � 1 Isl�9G'R M xplM w�f 6 M SO�M Muf R.Et swM4zt OIMAn 6 M MIXM�51 W4fIW C(�E �•�M•,m p�A���,t.�_ MPMEYI WMRA R SCTT 1..�0l9vP}I NdiK R4VfE 5 E�51.�Y„M kwG MMT/.YI.9Wi1V�: ti�wMl ,y�\IMDmI£R E. . �. �Y •1 W/K �ImM�LL RQVI TF MdIN ly I6i 6 M 91M]M(Ql Ci ME E�Si 3]]{gi Q yN NOitNFASi W.VfIW � R M xptM,[51 pJNRP R SW 3CAN. 'n91p E['�~'+1I a�l-�+u � - ' .waw�a�s�rz auK xm�x IDE.IP01 0.1/T . �FYIL ')mu�tiv0.ammtn�l �B ACrW'.A�' 1�5 ' . F4A tEt00 6 9A�E�-REC.M YY!}]901\ MA![mf 1ME EASI N iQi iW CQMM1 FO�O. 8E'MI61 PROVU9i ' P�t 6 NBIN FET ACIiE IViEA �1.�5 . . . - BA�JIS OF BEAFR'lCi� . . � 1C$ �.y e�rvrvn tch�awwr m�n uo a.w a oem uo wmnum er ouau m¢wort. � I�IRA HQ� � IK F.1M.Yl 1/4 YG 4 i-}IM.R-Y�Y � NL.�1U1 NL(fSLKS MO�5906 N11PE Q�IIfp[M1�6 MS IP�C�9VLL Ol�OmN 11YIO1'i1 IAAOVY WA161 Ff10M�Hi an(r ueua D/U FEOUP� s.e I ��uw imw'art - a�wr umnna smrnao�mw:unw m on[n urlo ug�cnon nim�m�on s we�m� 8pi001:0181NCT uavn Noe AIA%�d�Ml ND.OF ' . LE(3BID -� x w.n T u uomio�ar m�n.swi a mwK.m e.vu�rz rs��ro u owYS16�o�«. . - . FfE UIB1flCT� oamn N� DN ALLOW� . » � ea aaww zm.a u� a�n w.�s r o e�imiri sm��a�`vmc s¢ian��ff�vi°o�¢NOi�misu�n _ . cm cw�a g+e�a u� 'uo wu rar e�wam m a uusrtn rm nn nsvss . .. ' 7B.�FIOtg� - aar me�w�ma ' . Ei�1P10 ZOt8d0 x-a stmwnn xort-inc wEUwc u.rs vw naa . ' - i' - i pac�vmw.w x¢a m w rtm u��x.�c.s[.wu x�m+ann. .POWBI BOIRiCE wa�mao ooa. - Pf10P08�.ZOf@Ki R-]Z91FMN1 lPf-H�F dfLM4 UN3 NA NE . - I W¢ I ��Z�.��]� M IE9AINL'Alu/�E ��^��''l,� ' �I Ri�ZOPm'14 m n[mwnu x/b¢ �L� 4M9 vi �� . . I . . . ' z m iur'�i an ramns inrtn-wrto u�a es.tm , �- � � I u.ue'n an��s a*�w wrto uu�a a fm - - ' � 8�9fEf 1 OF 4 FOH'qp01T10NAL'N07�� . .. ._ � .. DAIFY-i�lO�N-POBLETE�'INC. OuLCPEA DEVaOPIBn,hc. ' . � �zs rweurtn w�r nomH . mc ai m�s ' . !� 'YO 9 weunN,.wwSN:NG�Ori Beo03 . x�e um�qc usr.a+au�.w�so O{ 9 a vMONE: (]SJ)J3!-3tpp (GM)JS]-4]O8, pnx[w psl]y]-�lq flB.�QIMY PLT OF . . �. �` � "a�oe....e D �PLA/dQ�O I� &IE�/� t�s . " t' - 30' O°` tolOSw .a. Y �� '-�IOFEB'to- IDIOS . 4 1 � � ; i , Q = , 50 •9 i �O � . O �' KINGSLEY ���'S i , _ pt � W rtR� z 48 VOL. 2 J�L9 23 ' . T wu_�isii�v'ss �a a� a6 a5 u' i s.ne,i+�jrz�ra 9O �RAOCGTiu•uBi• J2Pv 0 � i.c�.uarie•e _ _ - — .d9lv�c E E - 52 lE•�It6)10'S __�A�� __�_________ ___ .. Llx � 131 SFt ' . � . . .w vo I 4Y Q YW N14 COIRCCR�0..Vli 1 �f�Y a�" �WAPNYSFVµ�L(E14Y[xl I II `d.w x SEE NOIE ] x.xa Q W a wcsE.�c.00a vl�r� �erm.s - o�w iiroe/�u w�zs�av .v� �6 � :6 u.E _._T�-SMCEI-6CL4+1 �rai rwa � 's� F I> � xauc „ ' ]>ll1YI�C�1 ' � O y �$We�� � YI41 YI/UIEf� �.4C8.e- KP-Ylu Q. HWVtw� U „ F NO - i. �� Y �R P. - . . r .y�. o�W . I Q� �� I - Z - - - - - `� =�'-- _--:- �p ��.x� �CT'A' l ( i ? �b � k� W� . �. �" / � - . J � � - .>i=-� i� � N RE OEVELOaHENi � � s yl Z O i". � - /. � IS;N25ii \ .i'< Q 53 `� �•I' �.e•_. r SEE N01E.1 MiS"SN I BELOw ppiE ��J Yo ' ,�,fg}( � . �� w � . 2 ' � _ � _ .� . \ - �9 ��.% IlN] � . ' I . . ` 1 e , N.W.S.Mb'SI/�.MI/�.Yif/�. � � ` y�yy I / \ � �� . 1 ` SC p.I-]�Il R-Y 11u � . e � / / _ � -� I €I� w ------ �^ j�� 1� \— � � � c uwn ) � i �`a B a� ------ . L,_._ m ........t.�. _ ... _.z...__m . 3..—.. . � =e� -= �}� - �?� a.ae�ss�°- �eas�sr: u ��Qri65Fi ��°o '. A......... .......5.._..._. .�...-�'...�: .�p �1.. 3Y.....__�ll � . 3� nn° _ 3p /�� '� . B,]965Fk�p �. 8.0l9Y4 8.1!lSFt'�� :�� •� � �t . �.o � n °o° $ I - Cl.f.'/1NINfYL1Ml ('TS�.� � '12 . -�-��- ��..r ` PR WI O ^O 55 56 ;S� / � . -\ / / .:�� Y�\ �\ i Q� J N� m� _ / / / �J°-_ . \w� � J? b' ' X�' d� J � - N � .$ � � � ' opi � 1 � � I yp _ / � Z .cnrac� � -j^T.� / � � i � - I � ' �>'�w� / 1 Y. rw a/e'iuvu�un p . � 9Z tm1Y _ 'c�cexs �'c.c+.. �. ..�� . �' p � �aax. � E ^� �r ,/ GRAPHIC SCALE r _ ��I �cwere.� f� 1 . . ... . :. .... _ . " . _ M1 ,^ ..,. _:-- . � _ . :«. ... �. : - : �-:. . ,.. '.. ' - �� �S YW YuV `f LA Y SIN Yfl AqN � 101��.l].SY �YI!Rf 1 ro«�na�.0 - rs ,� iE.- �e�s(sl - i' e- w n . q iwc.. �ui ' 6.CSiVB n1,-� '8E'JJ/CIfuCE. ' . v� � 6 -- � m�u��iJlet 5 RIII�UJ.95 ' �C..�19R(x) • . TRAGT ..C.. E•�10.�&x) iE .�v ME) . . IF.��$01aE) it•sfooe(q KINGSLEY MEADOWS � !e.-�w� s) � - VOL. 219/19-23 , 4 TftACT "D TftPCT "B" W Z J - 435 a 435 - � . Z z � 440� y . 4�0 J a � $ PROPOSE� ADE ' ' � $ . . _ a � __ -_ I t" - aa' : PROPOSED GRA 430 - / l 43Q �i 435 — —� 435 ��� �� -�� � — 'i - � � � �EX. RADE 425 \ / -'_ —'- �' -_-- __ _—_- 425 _ _ �__ - 430 -- __ \ _ EX. G ADE _--� 430 . - � . \�/ � . � . � 10� I AlE a EX. W L E%. CRADE I �\ DR GE� � ' PROPOSED.(�+ADE , . . �E . a - DATUYS78V I _ __ - . _-_ - �_ - :- _ IZ0.00 DRA1 AGE DITCM \� °� `D o ^ � �' rn '�r.�i m� .- � r o . � 425 . \ 425 a � ya er y � aa -aY': ay � a v Ex. GRADE .Ot00 1+00 . 2+00 ' -3+00 '. - PROPOSED RADE � . DAYUI(676Y ' ' SECIKNJ B-8 _ SCALE:1 ��io'Mowz, . l20.� n Y. a'KPT. . � �O N m Ip n t0{� . N N N N(`� �� t0 n �'I Ml •ryVfW��� '. Gtt CWU[xiSlElrtF O�iED YKd 0.]O14 If uM'10 MI YI YI fV N lV N Hff BF�TS I Alm�L OF I FOR..✓✓��MVY_NOIES. v a"a aa a a a a . . �p,0�g , p D�Y36 �VBUR�n wn�MOR����. J6�B L�KEwUGE�M E�Sy�9JU�w� 98390M �lOO � 2�� v+��f `^ PrvONE:^I S])NS-2300GF/y:I�S]�30-]206 Pli(MC 35l-303-11B2 p$ P :1RA�TOLAS PLAT s� : r 8ECTIONao nAoa�z. 'FS� ca b`' Q D �,�&�YNO .� Conc;�lU,tiaiRpioM.l�u ` SCALE: Y. O vErtr. `�lOY�I _t� � - �'�� �..��SP. e, �'_ �o' ^papuc ,,,. 8 - 5 �°°�$P 1]MAT�II 1�-105 4 � � i � � � � , . ; 50 a9 � i Q ♦ @ � O p 5 Ye . r. . tlm 98 KINGSIEY `-�23 - S~ � a-rn[� - i VOI. 2 /'4 , i[.-.i��x��r's �a a� qb 5 �.io�� aa �ACi��8� J�Qv ' . 3 ' _ �E.�a�n tY! . . ENCR MENi �'1 ' 52 IE.��I�Ll1Y5 � . . 1 6� � Sff � ' _ '____'__'__ ' ' I� . �y x w n RPiM4GVACR➢fLWS I �.(��p �V .ISR$GWNUQE�UFIOIi ��Wt : �'� - rc rxsE.�armws rw�ri J ,� aa iuxmcr�a � _ SEE NOiE Z . z.s¢s Q m . o�rtn�iNS/moe � �n x�v/io-a� .ra ��'�s�aiiM iµS�9ffE1.BFl2 �6 u�� ' � F < n aZ I � � p _. ` t8/33'3CWlTSJB' ��1 �iH.s i se i � xc� �� � scc a.r-�n n-X w.K �axm�a . � . ,� u N� . r�.nr ir r�c e ui�x� �- - ' �� _ I "' °`°° �t ~ �n � I'�_ - tr ' _ _ - . ._,�.•__ �- - - ,n . ,eE . -�R �"°/ �CT'A' C ',6 1 rc��w.. . ; � r � . � - -- -- = �: � : � j N �zK��u��r � � � o , - . i � � � �1� �� _ s3 ,`�� � � �T -�-��^ � r SEE NoIE 1 MiS9� t BEtOw ` e.� �zeJ , Ff u�Q '� p ��% fD° �y. �rfamn� (m.)J 7 � � � � ` wu.S�.msl/�.xcf/4r.�lp. _� I . ;' •� . � � ttc c.�-ma n-x.'.0 � - = aaua mw i _ - , ; - . � _ � % . `. . � ' t:" -\\�� 1 \ I �'� � . p . , ______ a %.....1.�.;� - ..w ' t- . ,,. . B - ----�-...- 2......... . a�f. — :' :; __ q I '� t�� B39] YS�\ �e.z's srt ._.. . .... .: lL....t.... ��._.�J......... .C.. '• JJ'� . � o I = � � B296 SF3 ...... - .. ..$..� . ..y�1.. 3�i..... ;�. � / / — i.W . �.196 5FS✓ B.OS95F3 S.1}] SfS \a� s�o ��_'� t�o , � ,I n o0 y / . , �a�a � � � yrFl `�d�,.. 1 r � ; . o ^o ay � .�el hy .'� _ P" � � m_ 55 56 T5 I / � / IE'1 ffi ITF.) �y� pMMAY 101DT� � - I LZ\ JZ w' w' d n . aE Il���irsx� u�w�aE.f�w.) � � yM� J - i �o - . _ j / � � ' ' I YZ - i.n'sua a��"• auHart(mm. ..�� � \ S I � I GRAPHIC SCALE- � I � - - l[l�a a ___ " tEw w �(ttv.) r I rno s�e•cca.a s u> I ¢ ow�eu so m�r mt[o t,`x ----- - - --- - -- _!_ __ 1 I ta nor m n¢ v r4.�wv. o'wco. '- � _ - '-- - tla i_ _ __ M x> �f§�� � �m easr I :. ,. . ... . . r a r - - � r wwa. I y.r�caw.� ��t . . � e- m n I . t�s� � � -`-Aa on ., m r�..... '''� :- :- , � _ .. .- .,. __ . . _ .. �°.-{T u�-- a e'.�syn .'{5 a_�vw ..in�.���c�, . _ .�.F:w .-- . �.. i ..�+�w«� - .. y �F ._n FK �M _ IF ��N9X5) � :.�, �. _ : .� I '._<n�3ne _:r--_'._..� i��_ . - ^ =.- ..: — _ _ _ . � MM TV3AC T � %-......-,+i—..i/e«. — — — — — . . . _ . . 5 - . - 6 B�NL BE 1ELaCAIFD 50 TuT m-m2 i - - - , - ssui - N M pb�E1�Y v.w��S�ai � - . 5 wu��pl.sf . _ � u.-af m x) . . � � TRACT "C LE-�ml�E) �•�r.rM . ' - `E-�m0°�'� KINGSLEY MEADOWS 3 �c-uaie(s) - � VOL 219/19-23 TR�CT D" 4 TRACT "B' DATA,k ..w m SSMH No.2 = T'PE 1 " � ' 440 � � RIN ='434.00 4� OA v SSMH N 1 - TYPE.1. LE.�IN) _.427.BOt ' . ' . � ron�is-o) xruom saa n ro.m eac.r IA1 = 434.00�- LE. (WI T)'= 427.70t- saMns <owsn o�s.wu sna�.no aaa�w+u sc rwt I.E. (I = 427.104- PROPOSED CRADE ' Ftr�••19� I.E. (OU� = 4D.00f � � � w awcrw s*<ec awc wem zwx wrn e�/v� 4J5 /_ 435 \ ov cawno ov vwcr-am.xo oioevson E%. GRADE �/I\ ����A� I M c.ui.xv �/�.g .i-x+n.v-x vu - Lc 511dE1 YP� � f�TT(TN.1 R�T.xG W�IN�]T[ � Z � ri 430I 430 . n n: .: �zr: ..d�a.s xn . w: X: 8' STUB - s � �. s. tO6LF _ g• VC SDR 35 6 ]Ri � a m�.a. � 425 . �25. E��•�� I \ u vw.. . <� awe f+ro) �I , i I .. . TYPICAL SXI37/NG ROMMAY S6C770N (IAO�JG ABSfI � . . xn DAfVY CLCV - . _ ._ - ' . -. - IZO 00 �O M N oJ 1� 1� . . . . n ' n n n n n E�&�ET91 AI�2 OF 4 FOR ADD�IIDHAL NOTEB.' �' � �.an cmwis�crrta.wim�.uc a�mo �s u.w 5� a a a a e a �q�� DALEY-MOffiOWy.•����G�L�B�. •••� '�� S O �26 WBVRN WAY NOljjry IX�G�p����i }� B( . AVBURN, W.tSM�HGiqJ 08003 I �3�8 UYENIpGE OW�E EA51,�SVMNER, W�SBJ90 �` I i PXONE: (35JJSA-2200YIJ(:(IS]JSJS-3]OB -PHGNG I53-]13-1)B} ' ���0 �4�� ' 21�� i' . �B���Y� - <� � . 1�� . . . . I' = s0'HCRIZ. � �T�A$�AT SCaLE �' . ��u[Rr. - ?f tr �Ea�°a�`' Q.e<..... P �p�� I Ca1C�11W.URIf'lRAN - J/OYA l�6 r �g " 1 b' �'GR/.MNG ..�. � "eO A� I]MPYII �0.1 0$ 4 � o � , ... i Eichiliit 5, Number of Pages 2 I PREUMINAflY PLAT OF `- � �u�Gr�a _ s err��r, r�.�/� Kw.v�,���. R-se, wM. . r � G1Y OF Al18URN;KWt)c:OUNTY� WA8HAdQTON � � ��a N - � � f� w a�r m � 60 �O � . . _ I .. � ' 3 I � � Mewaows <`� � � --- a sa � a�a/�a-ta � KINGSI ��-))) . . '_"_".�� �s ; �s �r �i_n) �a -._ . � ' � � _ �� . i • �"""""' " &"4�8'°�� Di�4P�t � � ' Da �� '"..._. {(( �0yryI{{�� t�1� � u m Y . y' � �. .a n' 'n .. . . ��'.�''. 01!441,,BRaR PTA•�'�'.�"` y�' � tt.�\ � � ____ L'_'� "_" __. . _ ___'__b ., ... . �_� . . � o- n- • Ei'� «n � � �n I e� @ i---- i i--- I '---- - '- 1-�='�i i —� � xodt'd�s�a�mwi ., n� �ia..,�� �� _� ��� i y I � I � y N' _ . I " . � �.� : � � I I I ,1 I ' ' I � � 1� .}+ �� Y<4�-)qh'.l.ar. ' � � """" ""'"'_"'°"'..5� � � � � 2 � � ' I � � � 1 L � �r� t�tl � a:n srs � I nm va I euw s� � pan v: � aow s.i I I 8 ! i�� d�� � � .g i ► i ' i ► � i � i „»s. � t�; �Ntl �.o � n a� 6! 68 9� ' � ' � ' � I �� � � I � � sIl. � ' � � I' 9'ntl � 5e I � 1 � 1 �' i I � � ',I . I +� A ,• � ^ wnrnruseatav � _ � � � � � � I 1 � � 1 . � ' _ � . i �� � �� L���•q -- � I I � � � � i � � � L9 c _ __ � r --� - r=-- n----� I—��+.� � --=- ----- ► -l"__-' __I '__ _____' "'___' 1""_�J J a�aie`c�w� __ e R��s��YAY4 Mp�IMx\ .. . . d •�. _ --_ bNfWFOIt �q��qp� YN�I .m�l�il� � M � �._ � � p � ------- -' -�----- � - � eeammn�ce —_'—-— � a p - _ s � . . � . __ . . YRwGf 'C KING�ai ne�-a,� . s � m�or •u• . .mwes "a' . . 8 � a ' 611flR�ff'qOM710M- . . ...... , .. FIE6OBIMI:TABlB �Ne . ' � s'��m`�wr�a,'}^' fliOPWEO�MAUB@ vioi�uvwuou r �e ' � �iw ���tlx� �ImOPITflH1WO1B818 ' - term - ww..,�,rwttmruuoaiwn`maur.ioea.aexanwuwo�a OMR81/APPUGUR �S+�a.�om�m�.�.. flqPO8E0; � - • �re-r w YxrRw suo u+am.�w.w n ua+�em�un..a:a w swaa w�oaai �(�up�� ��r UOp/K i(�� q��p.p� ���„m'u0��� �1110Y4ftypN�VY0�4N�MO1Yi1 . dW r�wR�LLN �� 4f . ��KW(N�>IM�-4 M�1[I M�� .M.>l��N<V�MI6�If�fM��MW '�� ' PtIV�l9R� ��T�� l0 . . . . . ..... �g . . . WA191PflOqD6i onaKww '!^�0AlN,AAINaQ* 4CW.Mi� �rxarxu 5'�iY'e�rowmm.wvu�wrwaewas�.amo��wmux�aswn � .WY� !• . _. D41A�Mibi/M.�WIIRYtpW01A�Vb�1 W1tlM1W]I/MIIOY �d°1wno�voraaramseu.owwawuvau�an°�'ai rrxonowona � � BQIOQ:DHIFHCT eipwl�y .WVI7MIMNO�aP . � .. . � . � � HROBf1ECi owenP� L1�UMIAmW' ri ur�.ww—�a�ai.e - �R :aYa M9K.W�' N � 1aBFIDl� � e.n�taw+urwa� � EABNIOZOIQp wnwawwc-!ras.ai.num�w�w � .. . _.._. .... . . _. . ._ . w • . pp��g ���� � �.P110PO8EDLONPA MM4mMLtW-m[OiWHw�/M�� � �0.Qt11qGM�/µU1MPt1�utl�Na1L.ILfWK�Ini�41. I maanao me�o .�,«�;.;.w.�. a�eraxoare urea oP f PflOPOBED�(%8!� o4lcoaoWKV �N1L'6f1+Of 4u�>i, . . . .. . . . . . I i -' - . I ��11 N v�f N 4M1 lav(NI l(Iq�p¢�/!1h p . . � I>VY 4 fNI mwqpYlQt Mtl��YV l � � ' 8F£.'B�ET�OP� 'Itl11ADM. b1U�N�lEB ��r tn � ' .p+a.p � �rpp O6YR+OPI�Nf h0. N�ror� Ha�la ����"ppa��. . �Ao�iu�a°a"w��,N�.ww �� y�)-9t0i IW141Aq0I•�i11 . . 1 NH1QYIpRTOP Q. � � INDR/IM7lI�q ' ! .. . �� ... � " 1'.i7. t01MPP � w rn�e iaw , �=- � _ _ _ i , � � , � i � I so +9 Q] t �9 O — g4 KINCSIE`I �p�S r - - Q' t � -- . •e . va, ��+'V+� ta ; �J f.J='��.r . ' � . . I`n - �C.�ql �Yq �____+'___ AO 4 t��� � . 3 . �� .w.�w• " "� ' � ii"' .7" ���� ' 4 32. i}�iwim�a<�Nr. r �____�r y____. rz p . ' �Mw�wu���s�r � `� � �a� a s �s ' ',! � ��R- fU� dft4II ���� �. . u � � � _ �� i I �w _ _ . -d _ � 1 _ }� ~' s� .. . __ �-•� � n i._ lnda�. am . Pr � .p�.�e ' ' _ ' i' " v 'yj" . . . a � �«�,t�S < . �"a � � N��ISIOAWYSI ' ��1 .' O u � F.2p: . - e3 �'��$ / _ .. ; �_ ' ��.v-'� i K[110R H f �.lROe �faw�. �"v� - � � � � �> . _ � r ro ' .eammn (mJ J 1� � � < 1 .t� �. ` a .ae i.�rtir�,�a - � . . I' . � . . . ' ` -�. �"�"` -, � �_ d�4ie.y: �>:.....a..........1..:,' .:..:g... . ..y '. r� ` �� � ,� ' o < B . , �. .. ._' � '. _ _„ - w "' �..... p 6YY�YY �`di�st: - �� :. axw.F: �a8v: 1" ��� �...� . . - - � . nR Y . . ` 0.1DI Yf ��� •� O '� � n o8 v/ ' . ... � .11 _. \ "y�1�� tl� , �� � ,F �O' 59 00 §61' / ^ l �.: ILI0�i1}� � �N� t4YQI.tO/Ol `i� �� �' � J� y y Ip .O S�P. � ��ia�iw mmi,l(vV � � � y�� � � . � , 'd,� m ny..j / � i I: � ' GRAVIILC SCAIE � ' ' � Z�ww � � . 1 eau turatfro • 1 M m• ou�w d ' n � .____ t _'_ L' 1 �e wm � � I r aMn a4 W4'I+Y rb�n�..r — — ..} _ J �1 80" / - _ _ _ aT.'- w .� I�rml . � . __ __ r •1 ..i /� � �rw-r n �"^ .;..:.. _ !� 1 —'� ' _ — r..=� - " ' Y n°ix_a«��.ff-,> N,v ��� -__ ':uM� . _ __ ' n..nnry - � �-' . F�__.._. >.x..x.... - ' ' _ . "- .,. � ' _ �� . . o . , :� ._. - _�...,_. . ._...x.._ .:_,.�. . . -�4 . - � . ' ' r. � . � .. . ... . �� . . .�� �i_ , _ . ' � e .. .. — '- - -.— _=�° . . e �,� �o� vma .. � - � �[t'.�uh=a. � . . '-. . . " M�1Ci G �. - � . ' . '�•� KWGSIEY MEApOYS � J '���uii . yq_. 1�0/19-l� {qAGi 'O" � � . m�cr 'a' . hcM4Y5. tJBW.'$BiN6F� MAHJ� - . i . . SSy �g_� . tW � �Ae_l� �..4o�.T• i:s: �TN�j.N� TN6. �(�F'-�o fvS�D.. ���{� � . . _ _ _ _. �131W . . . . SSNN.N 1�_ �� LE!(�7 �t7.7�! '. . .Svd�i��v:IS�o i.7'��SH�4l_ CuNNt'C.'j-= ,,AI�.bLTL',�/_ rOvrt���<���'a�k.q e..uruy'[ -raum�.i - . qg N�sHq1MYMIWV.�4141� � . .. p 0.lY�IO����<� (W ..{27.OQk b'RAOE �NT�� ��i'LU' P.i 7'��t.. S4;uE�R. Ma�i,J 1� 30 !7 TH� r 1_.- S� � . mwr—i.�a�a>•�a�m`-�r an���aw ♦ __�.. �35 � . . . . E%. GflAOE p[ � w��.q.0 � / [{XIIIWrt �{ (tIV11MJ N4w vliW> � ; I _ _.. R . . _ . A I 4j(� -I.b . �/� �h N WtM� I � - If�- 1l�� B' SNB � . . . . _ ��- r � _ e. �. .O 7f[! r r _ _ . � . I , ._"�� , . �� . - . . I ` � 4L1 , 1!S a n.n � i - . - I 0.N�IHA . � . TYPtCIL ffiT9f/XO:ROIDOAY�H6CifON'(LOO1t7NC.IB9T) � . au ' � . . n� w .. .._ �- -� I B�BIEEf81A101OP�FOIIh00111fMqLNOlEB ��. a��...�rm. �.o...a ina ' .nev+�.. ' �, , : r'J� �.+� � . _. ° � - � ' �. ' ' 'MOAi1DYP'P�IETB.4�C 'OU.C�FACEV80PLEtli � . .. >Hytl wau rur aa�+wppp .a�e u.euoce cmt ns;umu w u»e � 0�00 . IiOO ' 2�00 � � fxRR: if�Y�SOOI/��Clf9))f l-!3W - MCM14�ilY]!t-Ili�' I I . �� IIObi�w� t-t Bi�R1CfpN0-lL�I�W�[I 001l811YLMJfIPU111 - � SCFLL 1'.���\[RL 'd!!n� ;r.Vi - ... D `���' r..IV_ ". Y.-�]0' ^"'WSA' .....e...� ^^� +� nu.n� io-ios - ' _ ... . . . . . . . . . . . . ....... , . � --- - - � I , � i ,y Exhibit 6, Number of Pages 3 CITY OF Peter B. Lewis, -Mayor AD-BURN,.=.-.- W25 West Main Street * Auburn WA 98001-4998 www.cauburnwa.cgov 253-931-3000 NOTICE OF APPLICATION (NOA) PRELIMINARY SUBDIVISION PLT10-0001- Tolas/Dulcinea Date of Notice of Application: March 25, 2010 Project Permit Applications were filed with the City of Auburn Planning and Development Department on February 12, 2010. The application for a preliminary subdivision was determined complete on March 8, 2010. Following is a description of the application and the process for review. The permit applications and listed studies may be reviewed at the offices of the Auburn. Planning and Development Department at One East Main Street, Auburn WA 98001. Description of Proposal: Subdivide approximately 1.45 acres into six single-family residential lots ranging in size from 8,049 square feet to 8,297 square feet together with an encroachment and future development tract. Proposal also includes sanitary sewers and storm drainage facilities. No road improvements are required. Project Proponent: James Tolas, Dulcinea Development Project Location: The site can be accessed via SE 307x' Place near 124`h Avenue SE. The site is within the Northwest Section 9, Township 21, Range 05 (NW 9-21-05) in Auburn, King County, Washington. Parcel Number 0921059090 Studies/Plans Submitted with Application: Preliminary Storm Report for Jim Tolas Plat, dated February 4, 2010, Daley-Morrow-Poblete, Inc.; Geotechnical report - Kingsley Meadows, dated March 6, 2003, Earth Consultants, Inc. Other Permits, Plans, and Approvals which may be required: Subsequent development will be required to obtain all necessary permits or approvals that may include: city preliminary and final plat approvals, facility extensions and building permits. Statement of Consistency and List of Applicable Development Regulations: This proposal is subject to and shall be consistent with the Auburn City Code, Auburn Comprehensive Plan, Design and Construction Standards, Building Code and Fire Code. Public Hearings: A public hearing is required for this proposal. A separate notice will be issued when the date has been scheduled. Public Comment Period: You are invited to comment, request a copy of the decision, when available, and be made aware of any appeal rights. Comments must be received in writing by the Auburn Department of Planning and Development at the mailing address: 25 West Main, Auburn, WA 98001-4998 and located at: 1 East Main Street, Auburn WA 98001 You are invited to express comments up until and at the public hearing If you have further comments or questions related to this application, you may contact Stuart Wagner, Planner at (253) 804-5031. If you call or write, please reference File No. PLT10- 0001. AUBURN* MORE THAN YOU IMAGINED seattletimes.corn PO Box 70, Seattle, WA 98111 AUBURN CITY OF-FINANCE DEPT ATTN CITY CLERK 25 WEST MAIN AUBURN, WA 98001 Re: Advertiser Account #30785204 Ad 788185100 Affidavit of Publication 4069070 / 3 STATE OF WASHINGTON Counties of King and Snohomish The undersigned, on oath states that he/she is an authorized representative of The Seattle Times Company, publisher of The Seattle Times of general circulation published daily in King and Snohomish Counties, State of Washington. The Seattle Times has been approved as a legal newspaper by orders of the Superior Court of King and Snohomish Counties. The notice, in the exact form annexed, was published in the regular and entire issue of said paper or papers and distributed to its subscribers during all of the said period. Newspaper, , Publication Date The Seattle Times 03/25/10 Agent Signature T •y{E~~1'~C~_ $6bscribed and sworn to before me on (DATE) (NOTARY PIGNATURE) Notary ublic~i and f r- e State of Washington, residing at Seattle c40t~e e, seattletimes.com Re Advertiser Account #30785204 Ad # 788185100 Ad TEXT'CITY OF AUBURN to obtain all necessary permits or ap NOTICE OF APPLICATION: provals that may Include: city March 25, 2010 APPLICATION preliminary and final plat ap REQUESTED: Preliminary provals, facility extensions and Subdivision APPLICATION building permits. STATE NUMBER AND NAME- MENT OF CONSISTENCY PLT10.0001 - Totas/Duiclnea AND LIST OF APPLICABLE PROJECT PROPONENT: DEVELOPMENT REGULA James Toles of Dulclnea Devel TIONS: This proposal Is sub opment PROJECT LOCA ject to and shall be consistent TION: The site can be accessed with the Auburn City Code, Au via SE 307th Place near 124th burn Comprehensive Plan, Do Avenue SE. The site Is within sign and Construction Stan the Northwest Section 9, Town dards, Building Code and Fire ship 21, Range 05 (NW 9-21-05) Code. in Auburn, King County, Wash PUBLIC HEARING: A pubiic Ington. Parcel Number hearing Is required for this pro 0921059090 DESCRIPTION OF posal. A separate notice will be PROPOSAL: Subdivide ap Issued when the date has been proximately 1.45 acres into six scheduled. PUBLIC COM single-family residential lots MENT PERIOD: You are Invit ranging In size from 8,049 ad to express comments up square feet to 8,297 square feet until together with an encroachment and at the public hearing. Writ and future development tract. ten comments may be submit Proposal also includes sanitary ted to Stuart Wagner, Planner, sewers and storm drainage Is Department of Planning and clllfies. No road improvements Development at the mailing ad are required. The permit appll dress 25 West Main, Auburn, cations and listed studies may WA 98001.4998 and located et: be reviewed at the offices of the 1 East Main Street, Auburn WA Auburn Planning and Develop 98001 or via email at swagn ment Department at One East or@auburmva.gov. If you have Main Street, Auburn WA 98001 further comments or questions APPLICATION FILED. Feb related to this application, you ruary 12,2010; COMPLETE may call Stuart Wagner, Plan APPLICATION: March 8, 2010 nor, at 253-804-5031. It you call or STUDIES SUBMITTED WITH write, please reference the ap APPLICATON: Preliminary plicatlon number noted above. Storm Report for Jim Toles City of Auburn Plat, dated February 4, 2010, Planning and Development Daley-Morrow-Poblete, Inc.; Department Geotechnlcai report - Kingsley 25 West Main Street Meadows, dated March 6, 2003, Auburn, WA 98001- 4998 Earth Consultants, Inc. 253-931.3090 OTHER PERMITS AND PLANS WHICH MAY BE RE QUIRED: Subsequent develop ment will be required 6 CITY OF Exhibit 7, Number of Pages 3 - Peter B. _l.awis, Mayor f: BU RN WAS 1-1. l N c*ro N 25 West Main Street * Auburn WA 98001-4998 * www.caiburnwa.gov * 253-931-3000 J Notice of Public Hearing Notice Published: Thursday July 7, 2011 The Hearing Examiner of the City of Auburn, Washington, will conduct a public hearing on July 20, 2011, at 5:30 P.M. in the Council Chambers of the Auburn City Hall located at 25 West Main Street on the following matter: Case Number: PLT10-0001 - Tolas/Dulcinea Preliminary Plat Applicant: James Tolas, dba Dulcinea Development Location: SE 307th Place near 124th Avenue SE. The site is within the Northwest Section 9, Township 21, Range 05 (NW 9-21-05) in Auburn, King County, Washington. Parcel Number 0921059090 Proposal: Subdivide approximately 1.45 acres into six (6) single-family residential lots ranging in size from 8,049 square feet to 8,297 square feet together with an encroachment tract and future development tract. The proposal also includes sanitary sewers and storm drainage facilities. No road improvements are required. . The public hearing.will be held in the Council Chambers, Auburn City Hall, located at 25 West Main Street. The public is invited to attend to express comments or opinions. Written comments may be submitted up until and at the public hearing to Stuart Wagner, AICP, Planner, Planning and Development, 25 West Main Street, Auburn, WA 98001-4988. If you have further comments or questions, please contact Planner Stuart Wagner at swagnero-auburnwa.gov or 253-804-5031. For citizens with speech, sight or hearing disabilities wishing to review documents pertaining to this hearing, should contact the City of Auburn within 10 calendar days prior to.the meeting, as to the type of service or equipment needed. Each request will be considered individually according to the type of request, the availability of resources, and the financial ability of the City to provide the requested services or equipment. Au wR- MORE THAN YOU IMAGINI'l) ~t~e ~ea~tte~itnes seattletimes.com PO Box 70, Seattle, WA 98111 AUBURN CITY OF-FINANCE DEPT W` ATTN CITY CLERK 25 WEST MAIN AUBURN, WA 98001 Re: Advertiser Account #30785204 Ad 798273200 Affidavit of Publication 4132990 / 3 STATE OF WASHINGTON Counties of King and Snohomish The undersigned, on oath states that he/she is an authorized representative of The Seattle Times Company, publisher of The Seattle Times of general circulation published daily in King and Snohomish Counties, State of Washington. The Seattle Times has been approved as a legal newspaper by orders of the Superior Court of King and Snohomish Counties. The notice, in the exact form annexed, was published in the regular and entire issue of said.paper or papers and distributed to its subscribers during all of the said period. Newspaper Publication Date The Seattle Times 07/07/11 Pe e& Signature a A_jrA 4,q - EX~j~•,'j.4,, CJ~~ c►1jed and sworn to before me on fr o ~ ' 7i ATE Auto SIG RE) Notary Publio,in an or th nafe of Washington, residing at Seattle i,, 10-7 ~r~,~~ `Christina, C.1~cKe~a ~e Sea~tte~tmes seattletimes.com Re Advertiser Account #30785204 Ad # 798273200 Ad TEXT•NOncE OF For citizens with PUBLIC HEARING: speech, sight or hearing disabil S' THE CITY OF AUBURN, ities wishing to review docu j. Washington Hearing Examiner ments pertaining to this hear will conduct a public hearing on ing, should contact the City of Auburn within 10 calendar days July 20, 2011, at 5:30 P.M. in the prior to the meeting, as to the type of service or equipment Council Chambers of the Au needed. Each request will be burn City Hall located at 25 considered Individually accord West Main Street on the follow ing to the type of request, the Ing matter: Case Number: availability of resources, and PLT10-0001 - Tolas/Dulcinea the financial ability of the City Preliminary Plat Applicant: to provide the requested James Toles, dba Dulcinea De services velopment Location: SE 307th or equipment. Published in the Place near 124th Avenue SE. Seattle Times on July 7, 2011 The site is within the Northwest Section 9, Township 21, Range 05 (NW 9-21-05) in Auburn, King County, Washington. Parcel Number 0921059090 Proposal: Subdivide approximately 1.45 acres into six (6) single-family residential lots ranging in size from 8,049 square feet to 8,297 square feet together with an en croachment tract and future development tract. The propo sal also Includes sanitary sew ers and storm drainage facili ties. No road Improvements are required. The public hearing will be held in the Council Chambers, Auburn City Hall, located at 25 West Main Street. The public is invited to attend to express comments or opin ions. Written comments may be submitted up until and at the public hearing to Stuart Wag ner, AICP, Planner, Planning and Development, 25 West Main Street, Auburn, WA 98001- 4988. If you have further com ments or questions, please con tact Planner Stuart Wagner at swagner@auburnwa.gov or 253- 804-5031. Earth Consultants, Inc. Exhibit 8, Number of Pages 40 (aYxcYlrnk:d H~f~in<tvti<~r~pgR~shfae\~r~xuixin.il5ci~yiil~+w Esiablislled 1975 (i~~.titr~x'thxi'It:titin~;R I(]i(>!~\•\lil)ln~xY'iHxi SSY\•kt;ti I f February 26, 2003 I Revised March 6, 2003 E-10470 Auburn 56, LLC 7947 - 59" Place Northeast, Suite 102 Redmond, Washington 98052 i ` Attention: Mr. Craig Sears Subject: Revised Geotechnicat Engineering Study ' Kingsley Meadows 124' Avenue Southeast King County, Washington Reference: Geotech Consultants, Inc Geotechnical Engineering. Study JN 01309, dated October 22, 2001. Dear Mr. Sears: At your request, Earth Consultants, Inc. (ECI) is providing additional geotechnical recommendations for the proposed project. ECI understands the currently proposed project consists of fifty seven (57) residential lots, a detention pond, access streets, and recreation areas. ECI has reviewed the referenced. geotechnical engineering study prepared for the previous owner of the site, visited the site to observe the existing site conditions and attended design meetings for the project. j Surface and Subsurface Conditions A single-family residence and garage currently occupy a portion of the site. The remaining site area is forested with evergreen and deciduous trees and associated underbrush. An approximately 20 foot deep east west trending ravine will be filled as part of the site development. i i 1805 136th Place N.E., Suite 201, Bellevue, WA 980p , Bellevue (425) 643-3780 FAX (425) 746-0860 Toll Free (888),7,39J6670',3, _ I 1 Auburn 56, LLC February 26, 2003 E-10470 Revised March 6, 2003 Page 2 1 DISCUSSION AND RECOMMENDATIONS General Based on the results of ECI's study, it is our opinion the proposed development can be constructed generally as planned. Building support may be provided using conventional 1 spread and continuous foundation systems bearing on the dense to very dense native-soils or 1 on structural fill used to modify site grades. Slab-on-grade floors may be similarly supported. This report has been prepared for specific application to this project only and in a manner consistent with that level of care and skill ordinarily exercised by other members of the profession currently practicing under similar- conditions in this area for the exclusive use of Auburn 56, LLC and their representatives. No warranty, expressed or implied, is made. This report, in its entirety, should be included in the project contract documents for the information of the contractor. Site Preparation and General Earthwork The site should be cleared of foundations, trees, surface vegetation, organic matter, and other deleterious material. Existing utility pipes to be abandoned should be plugged or removed so that they do not provide a conduit for water and cause soil saturation and stability problems. Erosion control measures should be installed prior to clearing and earthwork and maintained throughout construction. Based on the thickness of the forest duff, ECI estimates a stripping depth of ten inches. If more than eight feet of fill will be placed to subgrade elevations, the topsoil does not need to be stripped. Stripped materials should not be mixed with materials to be used as structural fill. Recommendations for placement of strippings in deep fills are provided below. 1 The soils encountered during the site exploration are moisture sensitive due to their high fines content. As such, in an exposed condition, they will become disturbed from normal construction activity, especially when in a wet or saturated condition. Once disturbed, in a wet condition, they will be unsuitable for support of foundations, slabs, or pavements. Therefore, during construction where these soils are exposed and will support new structures, care must be exercised not to disturb their condition. Consideration should be given to placement of rock or other methods to protect exposed native, undisturbed soils that will support foundations or new structural fill. If disturbed conditions develop, the affected soils must be removed and replaced with structural fill. The depth of removal will be Earth Consultants, Inc. f . I Auburn 56, LLC February 26, 2003 E-10470 Revised March 6, 2003 Page 3 dependent on the level of disturbance developed during construction. Given the above, a summer earthwork schedule is recommended. Structural fill is defined as compacted fill placed under buildings, roadways, slabs, i pavements, or other load-bearing areas. Structural fill under floor slabs and footings should be placed in horizontal lifts not exceeding twelve (12) inches in loose thickness and compacted to a minimum of 90 percent of its laboratory maximum dry density determined in accordance with ASTM Test Designation D-698 (Standard Proctor). The fill materials should be placed at or near their optimum moisture content. Fill under pavements and walks should I also be placed in horizontal lifts and compacted to 90 percent of maximum density except for I the four feet, which should be compacted to 95 percent of maximum density. During dry weather, most soils which are compactible and non-organic can be used as structural fill. The native soil will degrade if exposed to excessive moisture, and compaction { and grading will be difficult if the soil moisture increases significantly- above its optimum { condition. If the native soil is exposed to moisture and cannot be adequately compacted then it may be { necessary to import a soil which can be compacted. During dry weather, most non-organic compactible soil with a maximum particle size of six inches can be used. Fill for use during wet weather should consist of a fairly well graded granular material having a maximum particle size of six inches and no more than five percent fines passing the No. 200 sieve based on the minus 3/4-inch fraction. A contingency in the earthwork budget should be included for this possibility. Fill Slope Placement I I ECI anticipates fill will need to be placed on the site slopes. In ECI's opinion, the placement of fill on slopes is generally acceptable, however, where the slope exceeds 20 percent, the fill should be keyed and benched into the slope. This process consists of excavating a keyway at the toe of the planned fill. The keyway should have a width of about six to eight feet and depth of two feet into medium dense to dense native soil. The slope above the keyway should then be cut into a series of horizontal to slightly inward sloping benches. Typically, the benches are excavated with a small f bulldozer as the fill is brought up. The width of the benches will vary with the gradient of the slope, usually the gentler the slope, the wider the benches. Earth Consultants, Inc. l Auburn 56; LLC February 26, 2003 E-10470 Revised March 6, 2003 Page 4 f Plate 1, Slope Fill Placement, schematically shows the keyway and benches. The slope fill placed for the detention pond berm should meet the requirements for compacted till liners outlined in section 6.2.4.1 of the King County Surface Water Design Manual. k Stripping Placement Strippings may be placed in fill areas more than ten feet below the proposed finish grade. The strippings should be placed in lifts and compacted to a firm and unyielding condition. The strippings fill should be placed no more than six feet in thickness. A representative of ECI should be on site during placement to provide recommendations for lift thickness and compaction testing. Rockery Construction The primary function 'of a rockery is to cover and protect an excavated or reinforced fill j surface that would essentially stand near vertical or vertical. Rockery construction is largely a craft not entirely controllable by engineering methods. As such, it is imperative the proposed rockeries be constructed in close conformance with the Association of Rockery Contractors (ARC) Standard Rockery Construction Guidelines and by and experienced contractor with a proven capability in rockery construction. I Based on the soil conditions encountered on site, cut rockeries up to eight feet in height should be feasible. A typical cut rockery detail is attached as Plate 2. The rockery subgrade and. cut face should be observed by a representative of ECI prior to construction. ECI understands it is proposed to construct a fence along the south property line at the top of the cut slope and rockery. ECI recommends installing the fence into the native soils prior to cutting the area to- grade. Cuts for rockery construction should be at least five feet from the face of the installed posts. The top of 2H:1 V (Horizonta1:Vertical) cuts should also be at least five feet from the face of the posts. The area between the top-of the cut or rockery should either remain at existing grade or cut at 4H:1 V or flatter. I 1 ` Earth Consultants, Inc. I 1 . 1 f Auburn 56, LLC February 26, 2003 E-10470 Revised March 6, 2003 Page 5 i Foundations Based on the results of ECI's study, it is our opinion the proposed building may be supported on a conventional spread and continuous footing foundation bearing on competent native soil or on structural fill used to modify site grades. For frost protection considerations, exterior foundation elements should be placed at a minimum depth of eighteen (18) inches below final exterior grade. Interior spread foundations can be placed on competent native soils or structural fill exposed in crawlspace surfaces. With foundation support obtained as described, for design, an allowable bearing capacity of two thousand (2,000) pounds per square foot (psf) for structural fill or competent native soils can be used. Continuous and individual spread footings should have minimum In accordance with the Uniform Building Code. Loading of this magnitude would be provided with a theoretical factor-of-safety in excess of three against actual shear failure. For short-term dynamic loading conditions, a one-third increase in the above allowable bearing capacities can j' be used. i With structural loading as expected, total settlement in the range of one inch is anticipated with differential movement of about one-half inch. Most of the anticipated settlements should occur during construction as dead loads are applied. I. Horizontal loads can be resisted by friction between the base of the foundation and the supporting soil and by passive soil pressure acting on the face of the buried portion of the foundation. For the latter, " the foundation must be poured. "neat" against the competent native soils or backfilled with structural fill. For frictional capacity, a coefficient of 0.35 can I be used. For passive earth pressure, the available resistance can be computed using an equivalent fluid pressure of three hundred (300) pounds per cubic foot (pcf). These lateral resistance values are allowable values, a factor-of-safety of 1.5 has been included.' As !r movement of the foundation element is required to mobilize full passive resistance, the I passive resistance should be neglected if such movement is not acceptable. Footing excavations should be observed by a representative of ECI, prior to placing forms or rebar, to verify that conditions are as anticipated in this report. i I Earth Consultants, Inc. 1 Auburn 56, LLC February 26, 2003 E-10470 Revised March 6, 2003 Page 6 Retaining and Foundation Walls Retaining walls and foundation walls that act as retaining walls should be designed to resist lateral earth pressures imposed by the retained soils. Walls that are designed to yield can be designed to resist the lateral earth pressures imposed by an equivalent fluid with a unit weight of thirty five (35) pcf. If walls are-to be restrained at the top from free movement, the equivalent fluid weight should be increased to fifty (50) pcf. These values are based on horizontal backfill and that surcharges due to backfill slopes, hydrostatic pressures, traffic, structural loads or other surcharge loads will not act on the wall. If such surcharges are to apply, they should be added to the above design lateral pressure. For calculating the base resistance to sliding, the passive pressure and friction coefficient provided in the Foundations f section of this report should be used. If design against earthquake loading is desired, a rectangular pressure distribution equal to six times the wall height (6H) should be added to the above lateral earth pressure values. I f In order to reduce the potential for hydrostatic forces building up behind the walls, retaining walls should be backfilled with a suitable free-draining material extending at least eighteen 0 8) inches behind the wall. The remainder of the backfill should consist of structural fill. The free-draining backfill should conform to the WSDOT specification for gravel backfill for walls (WSDOT 9-03.12(2)). A perforated drainpipe should be placed at the base of the wall and should be surrounded by a minimum of one cubic foot per lineal foot with three-eighths inch pea gravel. i. Slab-on-Grade Floors i Slab-on-grade floors may be supported on competent native soil subgrade or on structural fill. Disturbed subgrade soil must either be recompacted or replaced with structural fill. Concrete slabs resting on soil ultimately cause the moisture content of the underlying soils to rise. This results from continued capillary rise and the ending of. normal evapotranspiration. As concrete is permeable, moisture will eventually penetrate the slab resulting in a condition commonly known as a "wet slab" and poor adhesion of floor coverings. Therefore, the slab should be provided with a minimum of four inches of free-draining sand or gravel. In areas where slab moisture is undesirable, a vapor barrier such as a 6-mil plastic I membrane may be placed beneath the slab. Two inches of damp sand may be placed over the membrane for protection during construction and to aid in curing of the concrete. i Earth Consultants, Inc. I• l I Auburn 56, LLC February 26, 2003 E-10470. Revised March 6, 2003 Page 7 Seismic Design Considerations The Puget Lowland is classified as a Seismic Zone 3 in the Uniform Building Code (UBC). In accordance with Table 16-J of the 1997 UBC, a site profile of Sc should be used for design. i Excavations and Slopes I The following information is provided solely as a service to ECI's client. Under no circumstances should this information be interpreted to mean that ECI is assuming responsibility for construction site safety or the contractor's activities; such responsibility is not being implied and should not be inferred. In no case should excavation slopes be greater than the limits specified in local, state and Federal safety regulations. The fill and loose to medium dense native soils would be classified as Type C by OSHA. Temporary cuts greater than four feet in height in Type C soils should be sloped at an inclination of 1.5H:1 V. The dense native soil would be classified as Type B by OSHA. In Type B soils temporary cuts greater than four feet in height can be steepened to 1 H:1 V. If slopes of this inclination, or flatter, cannot be constructed, temporary shoring may be necessary. Shoring will help protect against slope or excavation collapse, and will provide protection to workers in the excavation. If temporary shoring is required, ECI will be available to provide shoring design criteria. Permanent cut and fill slopes should be inclined no steeper than 2H:1 V. Cut slopes should be observed by ECI during excavation to verify that conditions are as anticipated. Supplementary recommendations can then be developed, if needed, to improve stability, including flattening of slopes or installation of surface or subsurface- drains. In any case, water should not be allowed to flow uncontrolled over the top of slopes. Permanently exposed slopes should be seeded with an appropriate species of vegetation to reduce erosion and improve stability of the surficial layer of soil. i I' Earth Consultants, Inc. 1 ! l " Auburn 56, LLC f, February 26, 2003 E-10470 Revised March 6, 2003 Page 8 I I Site Drainage If seepage is encountered in foundation or grade beam excavations during construction, the bottom of the excavation should be sloped to one or more shallow sump pits. The collected water can then be pumped from these pits to a positive and permanent discharge, such as a nearby storm drain. Depending on the magnitude of. such seepage, it may also be necessary to interconnect the sump pits by a system of connector trenches. The appropriate locations of subsurface drains, if needed, should be established during grading operations by ECI's representative at which time the seepage areas, if present, may be more clearly defined. During construction, the site must be graded such that surface water is directed off the site. Water must not be allowed to stand in areas where buildings, slabs, or pavements are to be constructed. Loose surfaces should be sealed -at night by compacting the surface to reduce the potential for moisture infiltration into the soils. Final site grades must allow for drainage away from the building foundations. The ground should be sloped at a gradient of 3 percent for a distance of at least ten feet away from the buildings, except in paved areas, which can be sloped at a gradient of 2 percent. Footing drains should be installed around the building perimeters, at or just below the invert of the footing, with a gradient sufficient to initiate flow. A typical detail is provided on Plate 3. i Under no circumstances should roof downspout drain lines be connected to the footing drain system. Roof downspouts must be separately tightlined to discharge. Cleanouts should be installed at strategic locations to allow for periodic maintenance of the footing drain and. downspout tightline systems. I j Utility Support and Backfill Based on the soil conditions encountered, the soils expected to be exposed by utility i excavations should provide adequate support for utilities. Utility trench backfill is a primary concern in reducing the potential for settlement along utility alignments, particularly in j, pavement areas. It. is important that each section of utility line be adequately supported in the bedding material. The material should be hand. tamped to ensure support is -provided around the pipe haunches. Fill should be carefully placed and hand tamped to about twelve M (12) inches above the crown of the pipe before heavy compaction equipment is brought into N Earth Consultants, Inc. i Auburn 56, LLC February 26, 2003 E-10470 Revised March 6, 2003 Page 9 1 use. The remainder of the trench backfill should be placed in lifts having a-loose thickness of less than twelve ('12) inches. Pavement Areas. The adequacy of site pavements is related in part to the condition of the underlying subgrade. To provide a properly prepared subgrade for pavements, the subgrade should be treated and prepared as described in the Site Preparation section of this report. This means at least the top four feet of the subgrade should be compacted to 95 percent of the maximum dry density (per ASTM D-698). It is possible that some localized areas of soft, wet or unstable subgrade may still exist after this process. Therefore, a greater thickness of structural fill or crushed rock may be needed to stabilize these localized areas. ! The following pavement section for lightly-loaded areas can be used (interior access streets): • Two inches of asphalt concrete (AC) over four inches of crushed rock base (CRB) material, or f • Two inches of AC over three inches of asphalt treated base (ATB) material. ! Heavier truck-traffic areas will require thicker sections depending upon site usage, pavement life and site traffic. ECI will be pleased to assist in developing appropriate pavement sections for heavy traffic zones, if needed. Pavement materials should conform to WSDOT specifications.. The use of a Class B asphalt mix is suggested. r LIMITATIONS j ECI's recommendations and conclusions are based on our observations on site, our review of the referenced study, the design information provided us, and our experience and engineering i judgement. The conclusions and recommendations are professional opinions derived in a manner consistent with that level of care and skill ordinarily exercised by other members of the profession currently -practicing under similar conditions in this area. No warranty is expressed or implied. f Earth Consultants, Inc. I i I • l , I Auburn 56, LLC February 26, 2003 E-10470 Revised March 6, 2003 Page 10 l Additional Services i ECI should also be retained to provide geotechnical services during construction. This is to f observe compliance with the design concepts, specifications or recommendations and to allow design changes in the event subsurface conditions differ from those anticipated prior to the start of construction. ECI do not accept responsibility for the performance of the ! foundation or earthwork unless we are retained to review the construction drawings and f specifications, and to provide construction observation and testing services. I ECI appreciates this opportunity to be of service to you. If you have any questions, or if we can be of further assistance, please call. Respectfully submitted, EARTH CONSULTANTS, INC. l W ~nIVAL 36103 E) ES 02-09-o Kristina M. Weller, P.E. Project Manager KMW/csm f Attachments: Plate 1 Slope Fill Placement Plate 2 Typical Rockery Detail, Native Cut I Plate 3 Typical Footing Subdrain Detail cc: Peterson Consulting Engineers Attention: Mr. Jon Nelson T. E. Briggs Attention: Mr. Tracy Briggs Earth Consultants, Inc. 1 SCHEMATIC ONLY - NOT TO SCALE j NOT A CONSTRUCTION DRAWING l: Ills FINAL SLOPE GRADIENT H'"flt Ill :c:• >:~r 11 mill ISEE TEXTlH c; `•'-;_:.:r=t'^ - r `IF77' EXISTING A NI GRADE 1% IRS 11~~ 11 TYPICAL "BENCH" -It MINIMUM 4 FEET WIDTH 1111(11 KEY' III fit=) I EXISTING ' III t GRADE 'LEGEND Free draining, organic free, granular material with a maximum size of 3 inches, containing no more than S. percent fines )slit and clay size particles passing the No. 200 mesh sieve) or other material approved by, geotechnlcat engineer. Key way fill is some as structural fill described above. Key way should be minimum 2 feet deep and 6 feet wide, extending the full length of the slope face. Approximate original ground line. i NOTES: . • Slope should be stripped of topsoil and unsuitable materials prior to excavating key way or benches. 0 Benches will typically be 'equal to a dozer blade width, approximately 8 feet, but a minimum of 4 feet. • Final slope gradient should be 2 . 1 I Horizontal: Vertical 1. • Final slope face should be densified by over building with compacted fill and trimming back to shape or by compaction with dozer or roller. ` • Planting or hydroseedirig slope face with a rapid growth deep rooted f vegetative met will reduce erosion potential of slope area. ! • Use of pegged In place jute matting or geotechnical fabric will help maintain the seed and mulch in place until the root system has an f opportunity to germinate. • Structural fill should be placed in thin loose lifts not exceeding 10 inches in thickness. Each lift should be compacted to no less than the degree specified In the site preparation and earth work section of this report. No additional lift should be placed until compaction ! is achieved. SLOPE FILL PLACEMENT i Earth Consultants Inc. Kingsley Meadows I F„g,,,OCM cMbMAS &F,-O ,,,,n„Wsd,ftt~ King County, Washington I - Prof. No.10470 Drwft. GLS Date Feb. 2003 Checked KMW Dated 2/26/03 Plate i l . r1 i T N. A;'':A..lll ' 6V :.4• da.;:.. ; A It tv; H `YII I Ec~u'w~D:s'ItrbrII:4Ywd_i~~b't j• 3 -~1 B H- Fig. A. ROCKERY SECTION Fig. B. ROCKERY ELEVATION ! SCHEMATIC ONLY - NOT TO SCALE NOT A .CONSTRUCTION DRAWING NOTES: Rockery construction is a craft and depends largely on the The long dimension of the rocks should extend back skill and experience of the builder. towards the cut or fill fence to provide maximum stability. A rockery Is a protective system which helps retard the Rocks should be placed to avoid continuous joint planes In weathering and erosion process on an exposed soil face. vertical or lateral directions. Each rock should bear on two While by its nature (mass, size and shape of the rocks) It or more rocks below it, with good flat-to-flat contact. will provide some degree of retention, it is not a designed All rockeries over 4 feet in height should be constructed on or engineered system in the sense a reinforced concrete basis of wall mass, not square footage of face. retaining wall would be considered designed or engineered. f The degree of retention achieved Is dependent on the size Approximate Approximate of the rock used; that is, the mass or weight, and the height Size Weight • lbs. Diameter - of the wall being constructed. The larger the rock, the more 1 Man 50-200 12-18, competent the rockery should be. 2 Man 200-700 18.280 Rockeries should be considered maintenance Items that 3 Man 700.2000 2836" will require periodic inspection and repair. They should be 4 Man 2000-4000 36-48" located so that they can be reached by a contractor if 5 Man 4000.6000 48-54" repairs become necessary. 6 Man 6000.8000 54-60" Maximum inclination of the slopes above and behind Reference: Local quarry weight study using average weights rockeries should be 2:1 (Horizontal:Vertlcal). of no less than six rocks of each man size conducted in. Minimum thickness of rock filter layer B=12 inches. January, 1988. Minimum embedment D=12 Inches undisturbed native soil LEGEND: or compacted fill placed In accordance with report . o P4#Q a°:4 Drainage materials to consist of clean recommendations Maximum rocker height H = 8 feet. r!:~.ko a. 4a.§• angular well-graded quarry spalls, with flinch rookery ° . maximum size, or other material approved by Rockeries greater than 8 feet in height to be installed the geotechnical engineer. under periodic or full time observation of the geotechnical Surface seal; may consist of impervious soil engineer. or a fine free-draining granular material. Unless otherwise specified in writing by the rockery Undisturbed firm Native Soil. "designer;' all rocks placed in the lower two-thirds of the It1=.1 l~ wall should be 5 to 6 man rock, 4000 lbs. or larger. Rocks ttt Drain pipe; 4-inch minimum diameter, placed above this level should gradually decrease in perforated or slotted rigid plastic ADS pipe size with Increasing wall height using 3 to 5 man rock, O laid with a positive gradient to discharge 700 to 6000 lbs, under control well away from the wall. Earth Consultants Inc. TYPICAL ROCKERY DETAIL ! •F'" NATIVE CUT, ANY HEIGHT OVER 4 FT. Prol. No. 10470 lDrwn. GLS DateFeb.2003 Checked KMW Data 2/26/03 Plate 2 r f p I ~f ....Li'~4•'}::':•~::3'~iY'; eye;: :t •£,:M."•^~titf~;-~: ;'c J;'., `•'i~ti.,~Gl.'.??~ ::~y-.2';4.rso-: _ O • •O .":_f?' :%~.c'v '+Y~'~ ~i: • ~5ls"`k _ • " i-.•; :ti-';:~.~ : 4C:ti::i. r: O • . a4.'ris, ~'~a..: .:4r ;g::, i~,i~;tjS (4'~ ~ - ~t~t'::3: •.;3F1~',:: '.B:L:.. • ♦ °o i i~r-•}-.!:35 c..Y~.'.;~~~i::~?. ~:r~~.~-,.~l ~Z~~F~7L~.~it`'~ f<Y• _ i, ~i`.:~,;~~t ° • o O 6 Inch min. T. ;.:r i a.~b'S,.;/• :4`i~i~s;?Y :+F •4<'~Y 1. L• '^~J:i!=i:•', O ~Y'_~`'~ - ~j:; i'?•~ jJ.`-us ,`'_%*`:11;,' :.r:q2-t}'e. ?ij}i„l: p."r ~ O . • , • • O ' ' . • 18 inch min. 41nch min. Diameter ;r.;,;:,; e • • .o ° ° 0 40 Perforated Pipe : ; • ° . e ° ° . ' O Wrapped In Drainage • e . o.' ° 4 0 ° o o b° o e o Fabric ° 2 Inch min. 2 Inch min. / 4 Inch max. 12 Inch min. i ' SCHEMATIC ONLY - NOT TO SCALE= NOT A CONSTRUCTION DRAWING I' LEGEND Surface seal; native soil or other low permeability material. Fine aggregate for Portland Cement Concrete; Section 9-03.1(2) of the e WSDOT Specifications. O Drain pipe; perforated or slotted rigid PVC pipe laid with perforations or slots facing down; tight jointed; with a positive gradient. Do not use flexible corrugated plastic pipe. Do not tie building downspout drains Into footing lines. Wrap with Mirafi 140 Filter Fabric or equivalent. TYPICAL FOOTING SUBDRAIN DETAIL Earth ConSUltEMtS Inc 'Kingsley Meadows ca`°a"+ W&%p emae~ &FA% raxMalSdMkts King County, Washington Pro]. No. 10470 Drwn. GLS Date Feb. 2003 Checked KMW Date 2/26/03 Plate 3 I ( . ZZ I Z6o l GEOTECHNICAL ENGINEERING STUDY Proposed Kingsley Meadows 56 - Lot Short Plat 122nd Place Southeast King County, Washington I This report presents the findings and recommendations of our geotechnical engineering study for the site of the proposed residential subplat to be developed at 122nd Place Southeast in. King County, Washington. We were provided with a general site plan and topographical map. Baseline Engineering, Inc. i developed this plan, which is dated December 14, 2000. Based on this plan, and conversations with Baseline Engineering and the current landowner, we understand that the site will be subdivided into 56 separate residential lots. Individual lot sizes will vary from approximately 4,850 to 10,794 square feet. The project will include the demolition and removal of the existing single- j family residence and its buildings located on the northern portion of the property. I The development will include the creation and/or extension of three roads, 122nd Place Southeast, Southeast 307th Place, and Southeast 308th Place. Southeast 308th Place will provide site access j from 124th Avenue Southeast. One-Hundred Twenty-Second Place Southeast will continue to provide access from 304th Street, however, the new portion of the street will be shifted to the east. Southeast 307th Place will end in a cul-de-sac on the property. The proposed development will create and utilize two storm drainage retention ponds on the site. The ponds will be located in the southeast and southwestern corners of the development. The size of the ponds will be approximately 5,600 and 17,000 square feet respectively. These ponds will drain water into the storm sewer system. The- information provided to us did not include a grading plan. We anticipate that extensive j regrading will be done for the development because of the varying topography of the site. We also anticipate that extensive trenching will be done to facilitate utility installation. A type-3 wetland tract is identified along the southern property line. A portion of the Wetland will be mitigated to make room for Southeast 308th Place. The 25-foot wetland buffers are identified by I the plan. SITE CONDITIONS i SURFACE The Vicinity Map, Plate 1, illustrates the general location of the site, southwest of the intersection of Southeast 304th street and 124th Avenue Southeast. T he irregularly shaped lot is approximately 13.6 acres in 'size. The southern portion of the property extends to the east providing approximately 165 feet of frontage along 124th Avenue Southeast. Drive access to the site is provided by 122nd Place Southeast which dead ends within property. 1hg afinder of"the----7 7_ property is bordered by residential properties. 1 " GEOTECH CONSULTANTS. INC. I Baseline Engineering, Inc. JN 01309 1 October 22, 2001 Page 2 Currently, the northern portion of the site is developed with a single-family residence and barn. These buildings appear to be constructed on conventional foundations without basements, and are ; located at the end of 122nd Place Southeast. The remainder of the site is undeveloped and covered with large trees and dense vegetation. Undeveloped access trails provide vehicle access to the corners of the site. . The topography of the site varies greatly from flat to steeply sloping. The northern, developed portion of the site is relatively flat to gently sloping down to the southeast. This developed portion of the site is on the northern side of a valley that extends from northeast to southwest through the middle/southern portion of the property. The southern side of the valley slopes upwards to the southern edge and southeastern portion of the property. The sides of the valley are moderately steep, with grades mostly ranging from 20 to 30 percent. However, the steepest grade of the valley walls is slightly under 40 percent at a location just south of the existing residence. The height of the valley walls is about 25 to 35 feet. We did not observe indications of instability on these slopes. j A wetland exists along the southern property line, however, no surface water was observed in this area during our site visit. A portion of this wetland will be mitigated as.proposed by the plans. l - SUBSURFACE The subsurface conditions were explored by excavating 12 test pits at the approximate locations shown on the Site Exploration Plan, Plate 2. Our exploration program was based on the proposed construction, anticipated subsurface conditions and those encountered during exploration, and the i scope of work outlined in our proposal. j = The test pits were excavated on September 13, 2001 with a rubber-tired backhoe. A geotechnical engineer from our staff observed the excavation process, logged the test pits, and obtained representative samples of the soil encountered. "Grab" samples of selected subsurface soil were collected from the backhoe bucket. The Test Pit Logs are attached to this report as Plates 3 I through 8. I Soil Conditions The test pits generally encountered up to 3 feet of native topsoil overlying weathered, gravelly, silty sand that was loose to medium-dense. The soil became dense to very dense- and glacially consolidated approximately 2.5 to- 7 feet below -grade. These soils are commonly referred to as glacial till in the Puget Sound area. This soil was typically observed to the maximum depth explored of 9 feet with the hereafter noted exceptions. t The glacial till was observed to be sandier than typical glacial till found in the Puget Sound area. In addition, the deeper silty sand soil excavated in Test Pits 6, 7, and 10 was dense to very dense, but was not cemented. The soil encountered in Test Pit 1 encountered slightly silty, gravelly sand approximately 2.5 feet below to the maximum explored depth of 5 feet. 4 00-16S feet of fill soil overlying the native soils was observed in Test Pits 4, 5, 9 and 121 + The fill soils are very organic, however, they varied in composition, location, and depth. f GEOTECH CONSULTANTS. INC. I Baseline Engineering, Inc. JN 01309 October 22, 2001 Page 3 Groundwater Conditions No groundwater seepage was observed during our excavations. However, the test pits were left- open for only a short time period. Therefore, the lack of seepage levels on the logs may not represent the lack of transient water seepage or the lack of a static groundwater level. It should be noted that groundwater levels vary seasonally with rainfall and other factors. We anticipate that groundwater could be found in more permeable pockets within the dense, silty sand and between the near-surface weathered soil and the underlying denser soil. The final logs represent our interpretations of the field logs and laboratory tests. The stratification lines on the logs represent the approximate boundaries between soil types at the exploration j locations. The actual transition between soil types may be gradual, and subsurface conditions can vary between exploration locations. The logs provide specific subsurface information only at the 1 locations tested. The relative densities and moisture descriptions indicated on the test pit logs are 4 interpretive descriptions based on the conditions observed during excavation. I The compaction of backfill was hot in the scope of our services. Loose soil will therefore be found in the area of the test pits. If this presents a problem, the backfill will need to be removed and replaced with structural till during construction. CONCLUSIONS AND RECOMMENDATIONS GENERAL THIS SECTION CONTAINS A SUMMARY OF OUR STUDY AND FINDINGS FOR THE PURPOSES OF A I GENERAL OVERVIEW ONLY. MORE SPECIFIC RECOMMENDATIONS AND CONCLUSIONS ARE CONTAINED IN THE REMAINDER OF THIS REPORT. ANY PARTY RELYING ON THIS REPORT SHOULD READ THE ENTIRE DOCUMENT. j The test pits conducted for this study generally encountered shallow depths fill and topsoil overlying loose, weathered glacial till. The silty sand and glacial till become dense to very dense r approximately 2 to 7 feet below grade. Based on this information, it is our opinion that the residential development is possible. The single-family residences can be constructed on conventional foundations bearing on the dense to very dense soils, or on structural fill placed above the competent soils. In the test pit locations, the depth of excavation to reach competent soil is j approximately 2 to 7 feet. However, the test pits also encountered pockets of fill soil in various locations. The fill soil was apparently placed randomly. However, it appears that a significant amount of fill was placed on the north valley slope just south of the existing residence. We j recommend that residences proposed in this area be positioned as far back from this slope as possible to avoid potential deeper fills. ` Test Pits 1, 2, and 6 were excavated in proposed storm water detention and/or infiltration areas on the site and encountered dense to very dense silty sand soils approximately 2.5 to 6 feet below grade. Because the dense, silty sand is only slightly pervious, we do not recommend infiltrating groundwater in these areas. If detention ponds that include earth berms are used for site storm water, it is important that compacted fills51splaced '5nly 16 dense, native soils in sloping areas. I GEOTECH CONSULTANTS, INC. Baseline Engineering, Inc. JN 01309 October 22, 2001 Page 4 j No signs of slope instability on the moderate to steep slopes of the valley sides were observed during our site visit. We do not anticipate any slope instability on the hillside due to the generally dense to very dense soils near the ground surface, the moderate inclination of the slopes, and the { lack of significant groundwater. Thus, only normal considerations for the slopes is generally needed, However, as noted earlier, since a considerable amount of old fill may exist south of the existing residence, we recommend that new residences in that area be located away from the slope if possible. Otherwise, some deeper excavations to reach bearing soil may be needed. The development of the site will require the removal of vegetation, topsoil, and the upper organic weathered soils. These soils will not be suitable for reuse as structural till and should be stockpiled for use in landscaping and non-structural areas or removed from the property. These soils should not be used for general grading purposes either due to the unknown location of the individual residential footprints. Grading with topsoil or highly organic soil in areas of future construction may result in pockets of loose degradable soil. These soils, if not found during future construction, could i result in building settlement. Due to the random pockets of fill soil observed on the development site and lack of a grading plan, i we would recommend continued soil studies be done for the individual lots as the site development . progresses. The amount of-fill soil to end up on the individual lots is unknown as well as the individual design requirements. Additional geotechnical studies could address these unknowns more specifically with respect to the individual residences. I A significant geotechnical consideration for development of this site is the overly moist to wet condition of the silty soils. Based on our observations, and the results of our laboratory tests, the l moisture contents of the on-site soils are significantly above the optimum moisture content necessary for the required structural fill compaction. These fine-grained, silty soils are sensitive to moisture, which makes them impossible to adequately compact when they have moisture contents even 2 to 3 percent above their optimum moisture content. The reuse of these soils as structural fill to level the site will only be successful during hot, dry weather. Aeration of each loose lift of soil will be required to dry it before the lift is compacted. Alternatively, the soil could be chemically dried by 1 adding lime, kiln dust, or cement, provided this is allowed by responsible building department. Regardless.of the method of drying, the earthwork process will be slowed dramatically. The earthwork contractor must be prepared to rework areas that don't achieve proper compaction due to high moisture content. Utility trench backfill in structural areas, such as pavements, must also be dried before it can be adequately compacted. Improper compaction of backfill in utility trenches and around control structures is a common reason for pavement distress and failures. Imported { granular fill will be needed wherever it is not possible to dry the on-site soils sufficiently before compaction. The erosion control measures needed during the site development will depend heavily on the 1 weather conditions that are encountered. While site clearing will expose a large area of bare soil, the erosion potential on the site is relatively low due to the gentle slope of the ground. We anticipate that a silt fence will be needed around the downslope sides of any cleared areas. Rocked construction access roads should be extended into the site to reduce the amount of mud carried off the property by trucks and equipment. Wherever possible, these roads should follow the j alignment of planned pavements. Cut slopes and soil stockpiles should be covered with plastic during wet weather. Following rough grading, it may be necessary to mulch or hydroseed bare areas that will not be immediately covered with landscaping or an impervious surface. 1 t GEOTECH CONSULTANTS, INC. 4 *seline Engineering, Inc. JN 01309 October 22, 2001 Page 5' Geotech Consultants, Inc. should be allowed to review the final development plans to verify that the recommendations presented in this report are adequately addressed in the design. Such a plan review would be additional work beyond the current scope of work for this study, and it may include revisions to our recommendations to accommodate site, development, and geotechnical constraints that become more evident during the review process. We recommend including this report, in its entirety, in the project contract documents. This report should also be provided to any future property owners so they will be aware of our findings and recommendations. i SEISMIC CONSIDERATIONS The site is located within Seismic Zone 3, as illustrated.on Figure No. 16-2 of the 1997 Uniform ii Building Code (UBC). In accordance with Table 16-J of the 1997 UBC, the site soil profile within 100 feet of the ground surface is best represented by Soil Profile Type Sc (Very Dense Soil). The site soils are not susceptible to seismic liquefaction because of their dense nature and the absence i of near-surface groundwater. 1 CONVENTIONAL FOUNDATIONS The proposed structure can be supported on conventional continuous and spread footings bearing on undisturbed, dense to very dense native soil, or on structural fill placed above this competent, native soil. See -the section entitled GENERAL EARTHWORK AND STRUCTURAL FILL for recommendations regarding the placement and compaction of structural fill beneath structures. 1 Adequate compaction of structural fill should be verified with frequent density testing during till I placement. Prior to placing structural fill beneath foundations, the excavation should be observed by the geotechnical engineer to document that adequate bearing soils have been exposed. We recommend that continuous and individual spread footings have minimum widths of 12 and 16 inches, respectively. Footings should also be bottomed at least 18 inches below the lowest adjacent finish ground surface. The local building codes should be reviewed to determine if different footing widths or embedment depths are required. Footing subgrades must be cleaned of f loose or disturbed soil prior to pouring concrete. Depending upon site and equipment constraints, ' this may require removing the disturbed soil by hand. Depending on the final site grades; overexcavation may be required below the footings to expose competent, native soil. Unless lean concrete is used to fill 'an overexcavated hole, the overexcavation must be at least as wide at the bottom as the sum of the depth of the overexcavation and the footing width. For example, an overexcavation extending 2 feet below the bottom of a 2-foot-wide footing must be at least 4 feet wide at the base of the excavation. If lean concrete is used, the overexcavation need only extend 6 inches beyond the edges of the footing. An allowable bearing pressure of 2,000 pounds per square foot (psf) is appropriate for footings supported on competent, native soil, or on structural fill placed above the competent, native soil. A one-third increase in these design bearing pressures may be used when considering short-term 1 wind or seismic loads. For the above design criteria, it is anticipated that the total post-construction settlement of footings founded on competent, native soil, or on structural fill up to 5 feet in I GEOTECH CONSULTANTS, INC. I Baseline Engineering, Inc. JN 41309 October 22, 2001 Page 6 thickness, will be about one-half inch, with differential settlements on the order of one-half inch in a distance of 50 feet along a continuous footing with a uniform load. Lateral loads due to wind or seismic forces may be resisted by friction between the foundation and the bearing soil, or by passive earth pressure acting on the vertical, embedded portions of the foundation. For the latter condition, the foundation must be either poured directly against relatively level, undisturbed soil or be surrounded by level -structural- fill. We recommend using the following ultimate values for the foundation's resistance to lateral loading: i Coefficient of Friction 0.50 I Passive Earth Pressure 350 pcf Where: (1) pcf is pounds per cubic foot, and (II) passive earth pressure Is computed using the equivalent fluid density. If the ground in front of a foundation is loose or sloping, the passive earth pressure given above will not be.appropriate. We recommend maintaining a safety factor of at least 1.5 for the foundation's resistance to lateral loading, when using the above ultimate values. PERMANENT FOUNDATION AND RETAINING WALLS Retaining walls backfilled on only one side should be designed to resist the lateral earth pressures imposed by the soil they retain. The following recommended parameters are for walls that restrain level backfill; Active Earth Pressure' 35 pcf Passive Earth Pressure 350 pcf Coefficient of Friction 0.50 Soil unit Weight 130 pcf where: (1) pcf is pounds per cubic foot, and (il) active and passive earth pressures are computed using the equivalent fluid pressures. For a restrained wall that cannot deflect at least 0.002 times its height, a uniform lateral pressure equal to 10 pat times the height of the wall should be added to the above active equivalent fluid pressure. The values given above are to be used to design permanent foundation and retaining walls only. The passive pressure given is appropriate for the depth of level structural fill placed in front of a retaining or foundation wail only. The values for friction and passive resistance are ultimate values and do not include a safety factor. We recommend a safety factor of at least 1.5 for overturning and sliding, when using the above values to design the wails. Restrained wall soil parameters GEOTECH CONSULTANTS. INC. Baseline Engineering, Inc. JN 01309 I October 22, 2001 Page I should be utilized for a distance of 1.5 times the wall height from corners or bends in the walls. I This is intended to reduce the amount of cracking that can occur where a wall is restrained by a corner. I I The design values given above do not include the effects of any hydrostatic pressures behind the walls and assume that no surcharges, such as those caused by slopes, vehicles, or adjacent { foundations will be exerted on the walls. If these conditions exist, those pressures should be added to the above lateral soil pressures. Where sloping backfill is desired behind the walls, we will need to be given the wall dimensions and the slope of the backfill in order to provide. the appropriate design earth pressures. The surcharge due to traffic loads behind a wall can typically be accounted for by adding a uniform pressure equal to 2 feet multiplied by the above active fluid density. Heavy construction equipment should not be operated behind retaining and foundation walls within a distance equal to the height of a wall, unless the Kalls are designed for the additional lateral pressures resulting from the equipment. The wall design criteria assume that the backfill will be well-compacted in lifts no thicker than 12 inches. The compaction of backfill near the walls should be accomplished with hand-operated equipment to prevent the walls from being overloaded by the higher soil forces that occur during compaction. Retaining Wall Backfill Backfill placed behind retaining or foundation walls should be coarse, free-draining structural fill containing no organics. This backfill should contain no more than 5 percent silt or clay particles and have no gravel greater than 4 inches in diameter. The percentage of particles passing the No. 4 sieve should be between 25 and 70 percent. For increased protection, drainage composites should be placed along cut slope faces, and the walls should be backfilled entirely with free-draining soil. The purpose of these backfill requirements is to ensure that the design criteria for a retaining wall are not exceeded because of a build-up of hydrostatic pressure behind the wail. The top 12 to 18 inches of the backfill should consist of a compacted, relatively impermeable soil or topsoil, or the surface should be paved. The ground surface must also slope away from backfilled walls to reduce the potential for surface water to percolate into i the backfill. The section entitled GENERAL EARTHWORK AND STRUCTURAL FILL contains recommendations regarding the placement and compaction of structural fill behind retaining and foundation wails. j The performance of subsurface drainage systems will degrade over time. Therefore, waterproofing should be provided where moist conditions or some seepage through the walls are not acceptable in the future. This typically includes limiting cold-joints and wall I penetrations, and using bentonite panels or membranes on the outside of the walls. Applying a thin coat of asphalt emulsion is not considered waterproofing, but will only help i to prevent moisture, generated from.water vapor or capillary action, from seeping through the concrete. With any project, adequate ventilation of basement and crawl space areas is important to prevent a build up of water vapor that may be transmitted through concrete i walls from the surrounding soil. I GEOTECH CONSULTANTS, INC. Baseline Engineering, Inc. JN 01309 October 22, 2001 Page 8 SLABS-ON-GRADE The building floors may be constructed as slabs-on-grade atop the medium-dense, or denser soils, or on structural fill. The subgrade soil must be in a firm, non-yielding condition at the time of slab construction or underslab fill placement. Any soft areas encountered should be excavated and replaced with select, imported structural fill. I All slabs-on-grade should be underlain by a capillary break or drainage layer consisting of a minimum 4-inch thickness of coarse, free-draining structural fill with a gradation similar to that discussed in PERMANENT FOUNDATION AND RETAINING WALLS. As noted by the American Concrete Institute (ACI) in Section 3.2.3 of the Guides for Concrete Floor and Slab Structures, proper moisture protection is desirable immediately below any on-grade slab that will be covered by tile, wood, carpet, impermeable floor coverings, or any moisture-sensitive equipment or products. ACI also notes that vapor retarders, such as 6-mil visqueen, are typically used. A vapor retarder is defined' as a material with a permeance of less than 0.3 US perms per square foot (psf) per hour, as determined by ASTM E 96. It is possible that concrete admixtures may meet this specification, although the manufacturers of the admixtures should be consulted. However, if no potential for vapor passage through the slab is desired, a vapor barrier should be used. A vapor barrier, as defined by ACI, is a product with a water transmission rate of 0.00 perms per square foot per hour when tested in accordance with ASTM E 96. Reinforced membranes having sealed overlaps can meet this requirement. Additionally, ACI (Section 4.1.5) recommends that a minimum of 4 inches of compactible granular fill, such as crushed rock, should be placed over the vapor retarder or barrier for protection. Sand is not recommended by AC1 for use as the protection layer. I We recommend proof-rolling slab areas with a heavy truck or a large piece of construction I equipment prior to slab construction.' Any soft areas encountered during proof-rolling should be excavated and replaced with select, imported structural fill. I EXCAVATIONS AND SLOPES Excavation slopes should not exceed the limits specified in local, state, and national government safety regulations. Temporary cuts to a depth of about 4 feet may be attempted vertically in unsaturated soil, if there are no indications of slope instability. However, vertical cuts should riot be made near property. boundaries, or existing utilities and structures. Based upon Washington Administrative Code (WAC) 296, Part N, the soil at the subject site would generally be classified as Type B. Therefore, temporary cut slopes greater than 4 feet in height cannot be excavated at an 1 inclination steeper than 1:1 (Horizontal:Vertical), extending continuously between the top and the bottom of a cut. The above-recommended temporary slope inclination is based on what has been successful at other sites with similar soil conditions. Temporary cuts are those that will remain unsupported for a 1 relatively short duration to allow for the construction of foundations, retaining walls, or utilities. r Temporary cut slopes should be protected with plastic sheeting during wet weather. The cut slopes should also be backflled or retained as soon as possible to reduce the potential for instability. Please note that loose soil can cave suddenly and without warning. Excavation, foundation, and i utility contractors should be made especially aware of this potential danger. 1 I i GEOTECH CONSULTANTS. INC. r Baseline Engineering, Inc. JN 01309 October 22, 2001 Page' ( All permanent cuts into native soil should be inclined no steeper than 2:1 (H:V). Fill slopes should not be constructed with an inclination greater than 2:1 (H:V). To reduce the potential for shallow sloughing, fill must be compacted to the face of these slopes. This can be accomplished by overbuilding the compacted fill and then trimming it back to its final inclination. Adequate compaction of the slope face is important for long-term stability and is necessary to prevent excessive settlement of patios, slabs, foundations, or other improvements that may be placed near the edge of the slope. Water should not be allowed to flow uncontrolled over the top of any temporary or permanent slope. Also, ail permanently exposed slopes should be seeded with an appropriate species of vegetation to reduce erosion and improve the stability of the surficial layer of soil. Any disturbance to the existing slope outside of the building limits may reduce the stability of the slope. Damage to the existing vegetation and ground should be minimized, and any disturbed areas should be revegetated as soon as possible. Soil from the excavation should not be placed on the slope, and this may require the off-site disposal of any surplus soil. DRAINAGE CONSIDERATIONS 4 Foundation drains should be installed at the base of all footings where the slab or floor is below the outside grade. Drains should also be placed at.the base of all earth-retaining walls. These drains ! should be surrounded by at least 6 inches of 1-inch-minus, washed rock and then wrapped in non- woven, geotextile filter fabric (Mirafi 140N, S(Jpac 4NP, or similar material). At its highest point, a perforated pipe invert should be at least 6 inches below the bottom of a slab floor or the level of a crawl space, and it should be sloped for drainage. All roof and surface water drains must be kept separate from the foundation drain system. A typical drain detail is attached to this report as Plate 10. For the best long-term performance, perforated PVC pipe is recommended for all subsurface drains. No groundwater was observed during our fieldwork. If seepage is encountered in an excavation, it should be drained from the site by directing it through drainage ditches, perforated pipe, or French drains, or by pumping.it from sumps interconnected by shallow connector trenches at the bottom of. the excavation. The excavation and site should be graded so that surface water is directed off the site and away from the tops of slopes. Water should not be allowed to stand in any area where foundations, slabs, or pavements are to be constructed. Final site grading in areas adjacent to buildings should slope away at least 2 percent, except where the area is paved. Surface drains should be provided where necessary to prevent ponding of water behind foundation or retaining walls. Additionally, a drainage swble should be provided upsiope of the buildings to intercept surface run-off and direct it into the storm drains. Water from roof, storm water, and foundation drains should not be discharged onto slopes; it should be tightlined to a suitable outfail located away from any slopes. PAVEMENT AREAS The pavement section may be supported on competent, medium-dense native soil or on structural fill compacted to a 95 percent density. Because the site soils are silty and moisture sensitive, we J recommend that the pavement subgrade must be in a stable, non-yielding condition at the time of ! GEOTECH CONSULTANTS, INC. l I Baseline Engineering, Inc. JN 01309 r October 22, 2001 Page 10 paving. Granular structural fill or geotextile fabric may be needed to stabilize soft, wet, or unstable areas. To evaluate pavement subgrade strength, we recommend that a proof-roll be completed with a loaded dump truck immediately before paving. In most, instances where unstable subgrade conditions are encountered, an additional 12 inches of granular structural fill will stabilize the subgrade, except for very soft areas where additional fill could be required. The subgrade should = be evaluated by Geotech Consultants, Inc., after the site is stripped and cut to grade. Recommendations for the compaction of structural fill beneath pavements are given in the section entitled GENERAL EARTHWORK AND STRUCTURAL FILL. The performance of site pavements. is directly related to the strength and stability of the underlying subgrade. i i The pavement for lightly loaded traffic and parking areas should consist of 2 inches of asphalt concrete (AC) over 4 inches of crushed rock base (CRB) or 3 inches of asphalt-treated base (ATB). We recommend providing heavily loaded areas with 3 inches of AC over 6 inches of CRB or 4 inches of ATB. Heavily loaded areas are typically main driveways, dumpster sites, or areas with truck traffic. i Water from planter areas and other sources should not be allowed to infiltrate into the pavement subgrade. The pavement section recommendations and guidelines presented in this report are 1 based on our experience in the area and on what has been successful in similar situations. As with any pavements, some maintenance and repair of limited areas can be expected as the pavement r ages. To provide for a design without the need for any repair would be uneconomical. f GENERAL EARTHWORK AND STRUCTURAL FILL i• All building and pavement areas should be stripped of surface vegetation, topsoil, organic soil, and other deleterious material. It is important that existing foundations be removed before site development. The stripped or removed materials should not be mixed with any materials to be used as structural fill,'but they could be used in non-structural areas, such as landscape beds. Structural fill is defined as any fill, including utility backfill, placed under, or close to, a building, behind permanent retaining or foundation walls, or in other areas where the underlying soil needs to support loads. All structural fill should be placed in horizontal lifts. with a moisture content at, or near; the optimum moisture content. The optimum moisture content is that moisture content that results in the greatest compacted dry density. The moisture content of fill is very important and must be closely controlled during the filling and compaction process. i The allowable thickness of the fill lift will depend on the material type selected, the compaction equipment used, and the number of passes made to compact the lift. The loose lift thickness 1 should not exceed 12 inches. We recommend testing the fill as it is placed. If the fill is not 1 sufficiently compacted, it can be recompacted before another lift is placed. This eliminates the need to remove the fill to achieve the required compaction. The following table presents recommended relative compactions for structural fill: } y GEOTECH CONSULTANTS. INC. Baseline Engineering, Inc. JN 0130Q October 22, 2001 Page 71 1 - Beneath footings, slabs 95% j or walkways Filled slopes and behind 90% II retaining walls i 95% for upper 12 inches of_ Beneath pavements subgrade; 90% below that level where: Minimum Relative Compactlon is the ratio, expressed In - percentages, of the compacted dry density to the maximum dry density, as determined in accordance with ASTM Test j Designation D 1567-91 (Modified Proctor). i I - I Use of On-Site Soil If grading activities take place during wet weather, or when the silty, on-site soil is wet, site preparation costs may be higher because of delays due to rain and the potential need to import granular fill. The on-site soil is generally silty and therefore moisture sensitive. 1 Grading operations will be difficult during wet weather, or when the moisture content of this soil exceeds the optimum moisture content. The moisture content of the silty, on-site soil must be at, or near, the optimum moisture content, as the soil cannot be consistently compacted to the required density when the moisture content is significantly greater than optimum. The moisture content of the on-site soil was generally above the estimated optimum moisture content at the time of our explorations. The on-site, gravelly, silty sand underlying the topsoil could be used as ( structural fill, if grading operations are conducted during hot, dry weather; when drying the wetter soil by aeration is possible. During excessively dry weather, however, it may be necessary to add water to achieve the optimum moisture content. Moisture-sensitive soil may also be susceptible to excessive softening and-"pumping" from construction equipment, or even foot traffic, when the moisture content is greater than the optimum moisture content. It may be beneficial to protect subgrades with a layer of imported sand or crushed rock to limit disturbance from traffic. The GENERAL section should be reviewed for considerations related to the reuse of on-site soils. Structural fill that will be placed in wet weather should consist of a coarse, granular soil with a silt or clay content of no more than 5 percent. The percentage of particles passing the No. 200 sieve should be measured from that portion of soil passing the three-quarter-inch'sieve. LIMITATIONS 1 The analyses, conclusions, and recommendations contained in this report are based on site conditions as they existed at the time of our exploration and assume that the soil and groundwater conditions encountered in the test pits are representative of subsurface conditions on the site. If the subsurface conditions encountered during construction are significantly different from those 1 observed in our explorations, we should be advised at once so that we can review these conditions 1 GEOTECH CONSULTANTS, INC. baseline Engineering, Inc. JN 01309 October 22, 2001 Page 12 I and reconsider our recommendations where necessary. Unanticipated soil conditions are commonly encountered on construction sites and cannot be fully anticipated by merely taking soil samples in test pits. Subsurface conditions can also vary between exploration locations. Such j unexpected conditions frequently require making additional expenditures to attain a properly constructed project. Due to the random pockets of fill soil observed on the development site and lack of a grading plan, we would recommend continued soil studies done for the individual lots as the site development progresses. It is recommended that the owner consider providing a contingency fund to accommodate such potential extra costs and risks. This is a standard i recommendation for all projects. I This report has been prePtired for the exclusive use of Baseline Engineering, Inc., and its representatives, for specific application to this project and site. Our recommendations and j conclusions are based on observed site materials, and selective laboratory testing engineering analyses. Our conclusions and recommendations are professional opinions derived in accordance j with current standards of practice within the scope of our services and within budget and time constraints. No warranty is expressed or implied. The scope of our services does not include services related to construction safety precautions, and our recommendations are not intended to 1 direct the contractor's methods, techniques, sequences, or procedures, except as specifically described in our report for consideration in design. ADDITIONAL SERVICES In addition to reviewing the final plans, Geotech Consultants, Inc. should be retained to provide geotechnical consultation, testing, and observation services during construction. This- is to confirm that subsurface conditions are consistent with those indicated by our exploration, to evaluate whether earthwork and foundation construction activities comply with the general intent of the recommendations presented in this report, and to provide suggestions for design changes in the event subsurface conditions differ from those anticipated prior to the start of construction. However, our work would not include the supervision or direction of the actual work of the I contractor and its employees or agents. Also, job and site safety, and dimensional measurements, will be the responsibility of the contractor. The scope of our work did not include an environmental assessment, but we can provide this I service, if requested. ? The following plates are attached to complete this report: Plate 1 Vicinity Map l Plate 2 Site Exploration Plan Plates 3 - 8 Test Pit Logs Plate 9 Grain Size Analysis Plate 10 Typical Footing Drain I GEOTECH CONSULTANTS, INC. Baseline Engineering, Inc. JN 09309 October 22, 2009 Page 13 r We appreciate the opportunity to be of service on this project. If you have any questions, or if we may be of further service, please do not hesitate-to contact us. f Respectfully submitted, GEOTECH CONSULTANTS, INC., Scott E. Stevens Geotechnical Engineer OgERT .ara ' ~~~lel 4~o~~w do c ONAIL, t f { I EMRES D. Robert Ward, P.E. - Principal j SESIDRW. alt 1 GEOTECH CoNsULTANTS. INC. • ^li SE 290TH SE 290TH K W N ,~RD ST SE 292ND PL S7 v, w ST W SE 292ND ST c SE 294TH ST $ N f SE 294TH PL + SE 295TH ST 4 N g W v SEW 29m 5T SE 6TH ST SE 297TH T-11 y i ST ,1 SE 298Tk 5T r- I up SE 299TH Si < a x . 1 A SE 301ST ST W SE 3 SE 30 W Ln N ID 0 a ~Wo SE 3D N o SE 302ND PL YYff u 3 132Do SE 302N0~ 1i sT SE 304TH ST SE 305TH sT 12400 SE 304TH TH W SE 305TH P T ; x -K sr W _ sr "li x 71dF7! r a 7odrx s S -K of usslas 1` 30fTM : . i SE 308TH ql K SE 308TH D SE oT~' 307rx Pt PL ~ ` Q SE 1 s< 7a~! SITE 310TH ST ~ ~ ~ 309TH ST M i LEA. - 9 v t11oD 8 HILL 11600 RD SE SE 312TH ST 10 R T sr SF sr ul n^ ~'IS s17Tw x 317 - R p N `F 12500 SE 3"13TN 6314E ST ~1?p I F k3)8,N. SEAM F INTEWTIOML RACBN aU315TH ^ - sr rt St K $ SE 3163T3H' : ST 7 Z9 G d H! l rte R 716D 7S1 77M L' ]17TH Sr S ~ct•L f T'_ nMRA U ]fdfN i t! 5Pn 3187H V11 ►Y+ CREFK _j 10 i t 71 jy T Dli Sf SE 316 D T ti -1-4 SE 320TH 1 AUaU H C K a S, ~u 3 rcn S7 SE 320TH ST *zoD -Ad 1ST ,t • WY N/ e umlu SE 023 P . FS 16 Yt u lan° s r` GREEN RIVER SE 3247H ST 0044 WITY COL V ^yCr 16-. 15 SE 326TH a N Cp AA > „ ` P~ of S 334TH !`moo P~eKi•ti`. - S ST 13ow LAKE HOLM: F uav h bl( ' A~ \ ~ c s !Sr577M W 14100 W ~ MIA } ! VICINITY MAP GEOTECH 122nd Place South East l CONSULTA I",q INC. King County, Washington 1 Na: Date: 01309 0ct2001 Scale: Scale Plate: 1 f 1 " i i 1 1 ,n d 11 TP-9 l7// TP-72 r TP-tt 1 \ 5 \t l occt~+a w.9.xrs / t7 / ~ - ~ i - j S TP-10 b / y ~CITP-4 c ~ 01 OTP-9 / t~~ t~ TP-7 TP-8 t SITE EXPLORATION PLAN uao-a _ GEOTECH 122nd Place South East p ~rvrquivETEST"Tt'DCDVW CONSULTANTS King County, Washington ' ; fir.,. ►~aws-- w... X,V'GoQ~`~~0 JSCy Description 1 Topsoill Topsoil SM Brown, gravelly silty SAND wl organics very moist, loose SP Brown/Gray slightly silty gravelly SAND, medium to coarse-grained, sM f moist, very dense 5 Test Pit was terminated at 5 feet on September 13, 2001. " * No groundwater seepage was observed during excavation. * No caving was observed during excavation. 10 i 115 I e, 01;{ TEST PIT 2 9 CP Ra Description Topsoil Topsoil Brown, gravelly silty SAND, fine-to medium-grained, moist, medium- sM : dense (Weathered Glacial Till) 5 Becomes gray, dense to very dense (Glacial Till) * Test Pit was terminated at 6 feet on September 13, 2001. No groundwater seepage was observed during excavation. j * No caving was observed during excavation. ++`f 0 1 ii 5 TEST PIT LOG GEOTECH 122nd Place Southeast CONSULTANTS, INC. Kin Count Washington Job No. Date: Logged by: Plate: 01309 Sep12001 SES 3 I 9 41c"e 111~(e OS Description TOpSOil Topsoil Brown,gravelly silty, SAND, fine to medium-grained, moist, medium- 'f; ' dense (Weathered Glacial Till sM : Becomes gray, dense to very dense (Glacial Till) Becomes sandy, dense ' 10 * Test Pit was terminated at 8 feet on September 13, 2001. " No groundwater seepage was observed during excavation. * No caving was observed during excavation. 15 f i e h TEST PIT 4 .31, 4e NP40; cep CIO" Description FILL Brown, gravelly silty, sand with old organics, loose to medium-dense Becomes black/brown (FILL) Brown,gravelly silty, SAND, fine to medium-grained with large rocks, moist, 5 medium-dense to dense (Weathered Glacial Till) i { sM Becomes dense to very dense (Glacial Till) * Test Pit was terminated at 8 feet on September 13, 2001. 10 * No groundwater seepage was observed during excavation. * No caving was observed during excavation. ,y I~ f TEST PIT LOG GEOTECH 122nd Place Southeast CONSULTANTS, INC. King County, Washington Job No: Date: Logged by; Plate: 4 01309 Sept. 2001 • sEs l Description Light brown gravelly silty sand, fine to medium grained, damp, loose (FILL) FILL I 1 Ashpalt pieces -I: Brown,gravelly silty, SAND with high amount of organics, fine to me ium- i U.~.~.I, grained, loose I SM Becomes medium-dense with less organics (Weathered Glacial Till) Becomes gray dense (Glacial Till) I ; 10 * Test Pit was terminated at 9 feet on September 13, 2001. * No groundwater seepage was observed during excavation. ` * No caving was observed during excavation. 15 TEST PIT 6 G5 1 4 FFr ~°ro ~P Description i Topsoil Topsoil Gray with Brown motteling silty SAND, fine- to medium-grained, moist, loose 5 Becomes medium-dense SM l Becomes gray, gravelly, dense 1 'li :hI i * Test Pit was terminated at 8 feet on September 13, 2001. 10 * No groundwater seepage was observed during excavation. 1 I No caving was observed during excavation. ~15 ' TEST PIT LOG GEOTECH 122nd Place Southeast CONSULTAN'T'S, INC. ~ King County, Washington f Job No: Date: Logged by: Plate: ^r - - 01309 Sept 2041 SES 5 I. CGS - - - - 9 CP 4 Description o soil To soil ML Gray sandy SILT, slightly plastic, very moist, loose i Gray silty SAND, fine- to medium-grained, very moist, medium-dense 15 'SM' ; Becomes gravelly dense 10 Test Pit was terminated at 9 feet on September 13, 2001. No groundwater seepage was observed during excavation. " No caving was observed during excavation. TEST PIT 8 9 CP z Description opsoii Topsoil j ; ; ; Brown gravelly silty SAND, fine- to medium-grained, damp, medium-dense sM : (Weathered Glacial Till) Becomes gray, silty (silty Glacial Till) f5 Test Pit was terminated at 6 feet on September 13, 2001. j R No groundwater seepage was observed during excavation. 1 " No caving was observed during excavation. 10 i i I TEST PIT LOG GEOTECH 122nd Place Southeast CONSULTANTS, INC. King County, Washington _ Job No: Date: Logged by. Plate. 01309 Sep1.2001 SES 6 LL_ 1 q G° Description FILL Brown silty sand with organics, rotting wood debris, moist, loose (FILL) o soil Topsoil Brown gravelly silty SAND, fine- to medium-grained, moist, medium-dense 5 SM :1 (Weathered Glacial Till) 1 M1 Becomes sandy, gray, dense (Glacial Till) * Test Pit was terminated at 7 feet on September 13, 2001. * No groundwater seepage was observed during excavation. 10 * No caving was observed during excavation. i .116 I TEST PIT 10 ~Qti*r~ o~~e~~a~rotiQ 9 CP ~a ' Description 0 oil Topsoil Reddish brown, silty SAND w/ organics,moist, loose Becomes gravelly without organics, dense ~S * Test Pit was terminated at 6 feet on September 13, 2001. i * No groundwater seepage was observed during excavation: 10 * No caving was observed during excavation. ~S 1 TEST PIT LOG GEOTECH 122nd Place Southeast CONSULTANTS, INC. King County, Washington i Job No: Date: Logged by: Plate. 01309 Sept. 2001 SES 7 I - C o tie ~d cc d i 9z4 ~p ~5 Description Brown gravellysilty SAND with organics, fine- to medium-grained, moist, rj:, il To soil medium-dense (Weathered Glacial Till) No organics ; ; ; becomes gray, dense (Glacial Till) * Test Pit was terminated at 7 feet on September 13, 2001. * No groundwater seepage was observed during excavation. 110 No caving was observed during excavation. X15 4 - e TEST PIT 12 ~4kv. 4"d0 9 Description FILL Brown silty sand, damp, loose (FILL) Topsoil Topsoil Brown graveliysiity SAND, fine- to medium-grained, moist, medium-dense (Weathered Glacial Till) ~5 sM: Becomes gray, dense (Glacial Till) Becomes sand * Test Pit was terminated at 7 feet on September 13, 2001. * No groundwater seepage was.observed during excavation. 10 * No caving was observed during excavation. ~3 TEST PIT LOG GEOTECH 122nd Place Southeast CONSULTANTS, INC. King County, Washington I JDafe: Logged by: Plate: 09 Sept. 2001 SES $ I - l SIEVE ANALYSIS HYDROMETER ANALYSIS SIZE OF OPENING IN INCHES NUMBER OF MESH PER INCH US $TO GRAIN SIZE IN MILLIMEYEAS ` N n a W N N a m 0 m O O o O O S O O a w N -0 O S O '00 m m A W N 90 IO r) BO O zo l O ~ 70 30 m m ~ 40 0 1 ° ?I n FFWWYI m 30 rn eo m m to -c,0 „t ~ so ~ m m = 30 S ~J D 20 BO I R? G7 0 9•' ~1 to 90 ° G VJ O 00 0 0 O O O ,O m Oi A W N - m T + W N - m p 0 O W N O O 8 8 O O O o/00 1 m ~ Q p r o V O O °W O o co V_ i;l N m ~ N M GRAIN SIZE IN MILLIMETERS Z. [COBBLES COARSE GRAVEL FINE COARSE MEDIUM' FINE FINES m SAND 3- BORING/ TEST PIT DEPTH SAMPLE MOISTURE KEY SYMBOL SOIL CLASSIFICATION `rp- I S / IS, s°!~ e SP 51.41.x, <•11-, 61:tNQ~ SA "1 V n- 3 . 8 ` / y, o d► S w Grcwc ill 5 • I SA RD lP-6 a 1 a• 1 % O S,-, G,o..,cll,~ S. fi Sitl-VO Jai 'e toc;c Co idv+ li • . . ~I Slope backfill away from j foundation. Provide surface drains where necessary. I j Tightline Roof Drain (Do not connect to footing drain) Backfill' See text for requirements) Vapor Retarder Nonwoven Geotextile or Barrier Filter Fabric «os.; SLAB •v.•oDe•0.~.00°.p.~.01.e.o.e.ODe.o'~•~Do. I ~ . 0 °(1 ° - j, f? 3 sk• < i- i~--- o •0.~;° •e ..'°;.'b.~.b b.~:b ti.r:b . e eQe e e >iiiEi''yi3;ie; i:-;a:i,•::., :-x:<::...:: .i• II r"y- IIIF n n n 'i'' ca%;o-:,..•:..-..:.<.:, s:;::::;•.:i::i;3s;aatt::~i ;z> v-ono :::L!Sd`;ti;s::'>;i`~.;•_.c:., ;:.r.„.;.,y<..yy.,:...,.- r,.irrrr. Vii,.:.:::: ~:n.._. ' ° i ~ll~ll l I 6" min. °0 °e_ e_° Free-Draining Gravel ' 4" Perforated Hard PVC Pipe (if appropriate) (Invert at least S inches below I slab or crawl space. Slope to drain to appropriate outfall. t~ Place holes downward.) iI I NOTES. (1) In crawl spaces, provide an outlet drain to prevent buildup of water that bypasses the perimeter footing drains. (2) Refer to report text for additional drainage and waterproofing considerations. ' FOOTING DRAIN DETAIL GEOTECH 122nd Place.South East CONSULTANTS, INC. King County, Washington ! Job No: Date. Scale: Plate: 01309 Oct 2001 Not to Scale 10 I 13256 Northeast 20th Street, Suite 16 Bellevue, Washington 98005 E O T E C H (425) 747-5618 FAX(425)747-8561 ONST LTANTS, IN January 29, 2002 JN 01309 i Kingsley Meadows LLC 1 5446 Hyada Boulevard NE Tacoma, Washington 98442 Attention: Robert Howe via facsimile: (253) 568-2330 Subject: Revlew of Recent Plans Proposed Kingsley Meadows Subdivision 122nd Place Southeast King County, Washington Dear Mr. Howe: We had previously prepared a geotechnical engineering study regarding this project dated October 22, 2001. At that time, the plans for the project were somewhat preliminary and the stormwater system was not yet determined. We recently received an updated "preliminary plat" of the project that provided topography and grading information. The "preliminary plat" information (Sheet.I of 2), was prepared by Baseline Engineering, Inc. and dated December 14, 2000 (we assume the date was supposed to be 2001). The new information indicates that the layout of the subdivision has changed from the original plans, but in general they have not affected the recommendations and conclusions presented in our study in our opinion. However, the design of the stormwater detention pond (Tract E) has been substantially updated since the time of our study. This letter provides comments regarding the new plan for Tract E, as well- as provides other recommendations regarding stormwater drainage on the site. The current plan for the stormwater detention at Tract E is for an open pond that is just under one acre in size. It will be located at the southwestern corner of the site. This location is mostly in the western end of a wide Swale that extends from the east on the property: The bottom elevation of the pond will be 398 feet, andmthe sides of the pond will be either vertical retaining walls or 3:1 (H:V) slopes. The lower portion of the existing swale will be filled as much as 10 feet to raise the existing grade up to, the proposed pond bottom, while cuts as much as 16 feet are proposed on the north and south sides where the pond will be set into the existing slopes above the Swale. In addition, fill soils are proposed on the downslope 2:1 (H:V) slope at the side of the western retaining wall of the I pond. As noted above, significant amount of fill soils are proposed below the pond and for the slope outside the western retaining wall. It is very important that, since these soils will be placed on or used to form a slope, they not become saturated because they could become destabilized, For this reason, we recommend that the base of the pond and the side retaining walls be covered with an impermeable barrier. The base of the pond could be lined with a bentonite/soil mixture, or be f covered with a man-made geomembrane. Because of the large size of the pond base, it may be more economical to use the bentonite mixture. The impermeable layer against the retaining walls could be similar to heavy waterproofing materials used for basement walls, such as a bentonite product. The waterproofing on the wails could go directly on the outside of the walls. As we noted in our study, the majority of the te encountered the Theedewas nse silty soils arse nearly very dense within about 3 to 4 feet below the ground GEOTECH CONSULTANTS, WC. JN 01309 Kingsley Meadows, LLC Page 2 January29, 2002 impermeable. Because of the nature and density of this the site soils, we do not believe that the stormwater system for this project should include infiltration. We understand that the stormwater system does not include infiltration at this time; we agree with this methodology. If you have any questions, or if we may be of further service, please do not hesitate to contact us. I - Respectfully submitted, OEOTECH CONSULTANTS, INC. UT l . ~'MAL D. Robert Wa d, P.E. I Principal DRW: esm i I - - i i GEOTECH CONSULTANTS. INC. 1993 AASHTO Pavement Design DARWin Pavement Design and Analysis System A Proprietary AAS14TOWare Computer Software Product Earth Consultable, Inc. 1805 -136th Place Northeast, Suite 201 Bellevue, Washington USA Flexible Structural Design. Module 124th Avenue Southeast Flexible Structural Design 18-kip ESALs Over Initial Performance Period 3,667,034 Initial Ser imbUlty 4.2 Terminal Serviceability 2.5 Reliability Level 90% Overall Standatd Deviation OAS Roadbed Soil Resilient MWus 18,562 psi Stege Construction l i Calcutated Design Structural Number 3.04 in Effective Roadbed Soil Resilient Modulus .R.oadbea ttesilicrn eri Desc ' 'on dole si ! su►nmer 25,000 2 felt 25,000 3 winter 18,000 4 spring 14,000 Calculated Effective Modulus 18,562 psi Simple ESAL Calculation Perfo mance Period (years) 20 l Two-Way Traffic (ADT)l 13,000 Nuutber of Lanes In Dosiga Direction 1 Percent of.A.11 Trucks-in benign Lane 100% Percent T mcka In Design Direction 30 % . li Percent Heavy Trucks (of ADT) FHWA. Class 5 or Greater 2% Average Initial. Truck Factor MSAL&Aruck) 2.4 Annul 'Crock Factor Growth Rate 2% ` Annual Trunk Volume Growth Rate 3.5% 1 Growth Simple Total Calculated CumaulWw ESALs 3,667,054 ` Page 1 V - 1 i i Specified Layer Design Strvct Drain coot Coet Thickness Width Calculated riat. esCrii+tion LAD in 1 asphalt emicrale 0.42 1.05 4 1.76 2 CSTC 0.14 ! 2 . 3 CSIte 0. 0.14 i 715 l.03 OS Total - 13.50 - 3.09 Layered Thickness Design nicknosq precision Actltal i Strvi Drain Spec Min Elastic Calcultued j Coef. Coef. Thickness Thickness Modulus Width Thicknoss Calculated Layer Material 1?esc n n fAU aail OKIA) Q" (w L.1 m SN Can) 1 Asphalt-Concrete 0.42 ' 1.05 4 400,000 - 4.00 1.76 2 ATB 0.3 1 - 5 250,000 - 5.00. 1.50 Total - - • 9.00 3.?b I i I 1 I i 1 f i Page 2 Exhibit 9, Number of Pages 31 a CITY OF -W -Ir Peter B. Lewis, Mayor U RN WASHINGTON 25 West Main Street * Auburn WA 98001-4998 * www.ouburnwa.gov * 253-931-3000 March 8, 2010 James Tolas dba Dulcinea Development 3618 Lakeridge Drive E. Sumner, WA 98390 Hans Korve dba DMP Inc. 726 Auburn Way N. Auburn, WA 98001 Re: Tolas / Dulcinea Preliminary Plat- 1st Correction Letter, APN# 0921059090 Plat Application PLT10-0001 Gentlemen: The City of Auburn received the Preliminary Plat and supporting documents on February 12, 2010. At this time, the application is determined complete as of the submittal date. The 120-day time clock has begun for the project. Please be aware that if additional information is requested the review clock will stop until the requested information is received by the city. The application is under review concurrently by the City's Public Works Department and Planning and Development Department. Each department has completed its review and has the following comments: Public Works Department General 1. Water and sewer paybacks are assessed for this property. Fees will be due at first connection to utilities Survey Division 1. Title report from Pacific Northwest Title, Order Number 1108268 dated January 22, 2010 is within the 30-day window of the application date 2/8/2010. Future review will require an updated title report. 2. Map Page 1 of 4: ACC 17.10.020(D) (1) (e) stipulates an approval block for the City Council approval and signature by the Director of Planning & Community Development Department. This is needed on the plat. Please refer to red-lined markup of the short plat drawing attached to this letter. Contact Robert Burton at (253) 804-5066 or rburton@auburnwa.govwith any questions regarding these comments. Utilities - Water Division 1. There is an 8 inch water main south of the Applicant's parcel from which 4 duplex water services were-constructed under an earlier project. The location of the duplex services does AUBURN* MORE THAN YOU IMAGINED James Tolas and Hans Korve - PLT10-0001 a March 8, 2010 Page 2 of 4 not align well with the proposed lot layout. 2. The Applicant proposes to provide service to Lots 1 and 4 by installing the private service line back of the meter within the ROW to reach the two parcels. The Applicant shall either a) install new water service connections to serve Lots 1 and 4 or b) install the private service lines outside of the ROW and across the adjacent parcels, and obtain access agreements across Lots 2 and 3. 3. The meter for Lot 5 is located in the driveway approach. Per City Design Standard 7.01.2.1.D, residential sites should have water meters placed in landscape strips within the right of way. If no unpaved areas exist in the right-of-way, water meters may be placed outside the right-of-way In unpaved areas within a public water utility easement. 4. The Applicant's parcel is located within the critical area known as Ground Water Protection Zone 4. The Applicant shall implement best management practices for water resource protection per ACC 16.10.120(E)2. 5. Design of any water service improvements shall meet the requirements of City Design Standards Chapter 7 - Water Facilities. Please contact Cynthia Lamothe, Water Utility Engineer, (253) 804-5061 or clamothe@auburnwa.gov for questions related to Water comments. Utilities - Sewer Division 1. The applicant has proposed sewer main extension onto the proposed property. That extension of the public system is not necessary, and it is preferable to have the individual lots connected to the sewer system via individual side sewers connected to the sewer main in 307th Street SE. The sewer easement would, therefore, be unnecessary. 2. FYI to applicant: As-built drawings show the end of the 8" stub being 7.2' deep (7' shallower than is shown on these plans). Please contact Bob Elwell, Sewer Utility Engineer, (253) 931-4008 or relwell@auburnwa.gov for questions related to Sewer comments. Utilities - Drainage Division No comment Traffic Division 1. Provide sight distance triangles at all site driveways. 2. Provide a typical roadway section showing in cross section the location of pavement, sidewalk, landscape strip, trees streetlights. 3. Note on plans that no vehicular access will be granted by the City of Auburn to 124th Ave. SE via Tract A. 4. An existing cherry tree is shown in the middle of the driveway of proposed lot 1, please address that issue by noting that tree will be relocated or that the driveway will be relocated. 5. A water meter is shown in the middle of driveway for Lot 5, please address that issue by noting that meter will be relocated (or strengthened) or that the driveway will be relocated. James Tolas and Hans Korve - PLT10-0001 March 8, 2010 Page 3 of 4 6. Submittal checklist (provided with application) - Item I - the note that "no traffic impacts are expected" is not correct. No traffic study is required as a result of the low expected traffic impacts from the development but it should be noted that traffic impact fees will be required by the City at time of building permit for each residence. - Item J - The surrounding existing street system (124th Ave SE a minor arterial and SE 304th a minor arterial) to this proposed plat does not provide a continuous sidewalk connection to Rainier Middle School, or the nearest elementary schools: Lea Hill or Hazelwood. As a result, the applicant's response to Item J does not constitute an adequate school access analysis as required. It implies that safe walking conditions exist to connect the plat to surrounding schools and they may indeed not. The applicant shall complete a thorough school access analysis which includes participationwith and written response from the Auburn School District indicating whether students for this plat will ' likely be bused or required to walk to elementary, middle and high school. if they are required to walk to school, the school district should indicate to the applicant in writing whether those walking routes are considered safe walking routes to school. That documentation shall be provided to the city. Please contact Joe Welsh, Transportation Planner, at (253) 804-5050 or jwelsh@auburn.wa.gov for questions related to Traffic comments. Critical Areas Review 1. On the Master Land Use application concurrent application sheet "Shoreline Exempt" is marked. No shoreline exemption is required since the proposed plat is not in the City's shoreline jurisdiction. 2. SEPA may be required depending on the amount of grading proposed on the site (500 cubic yard threshold) and the potential presence of critical areas on-site. 3. City of Auburn critical areas maps indicate an erosion prone critical area on the northwest portion of the property. This area may constitute a Critical Erosion Hazard Area as defined in ACC 16.10.020 and 16.10.080.G.1. Critical erosion hazard areas are lands or areas underlain by soils identified by the U.S. Department of Agriculture Soil Conservation Service (SCS), now known as the Natural Resource Conservation Service, as having "severe" or "very severe" erosion hazards. This includes the following group of soils when they occur on slopes of 15 percent or greater: Alderwood-Kitsap (AkF), Alderwood gravelly sandy loam (AgD), Kitsap silt loam (KpD), Everett (EvD), and Indianola (InD). 4. While the submitted Kingsley Meadows geotechnical engineering study is nearby to the proposed Tolas Preliminary Plat, it does not appear to cover the project area. 5. A critical areas report and appropriate mitigation measures (including development setbacks) may be required for this proposal. Please consult a qualified geotechnical consultant to evaluate on-site conditions and complete any associated critical area requirements pursuant to Chapter 16.10 ACC. James Tolas and Hans Korve - PLT10-0001 March 8, 2010 Page 4 of 4 Please contact Jennifer Shih, Environmental Planning, (253) 804-5092 orjshih@aubumwa.gov for questions related to Critical Areas comments. Planning and Development 1. The purpose of Tract A needs to be stated on the preliminary plat. Please add a_note to the preliminary plat stating its intended use and who will own.it. Ex. TractA is a future development tract and is retained by the owner of Tract A, its successors and assigns, for ownership and maintenance. Tract A will be re-platted or adjusted to... 2. Please remove Tract B from the preliminary plat. While "tracts" are used and designated for specific purposes, one should not be created to handle encroachments. Please consider using an "easement agreement" between two parties to handle this situation. Attached is an example. 3. A public utility easement (P.U.E.) that Is to be reserved and conveyed to Puget Sound Energy, Telecommunication companies, City of Auburn, and any other private utility company was not identified on the preliminary plat. Please indicate if this P.U.E. is already present or else add this easement to the preliminary plat. Please contact Stuart Wagner, Planner, at 253-804-5031 or swagner@aubumwa.gov with questions regarding these comments. Conclusion Once the City receives the requested information as outlined in this correction letter, review of this application will continue. Re-submittals must address all items in this correction letter. Re- submittals are required to be submitted to the Planning and Department, Second Floor, Auburn City Hall Annex Building. Submitting a letter of clarification regarding the changes will further expedite the City's review process. Additional corrections may be necessary as a result of submitting this updated information. Should you have any questions regarding this letter or outstanding permit issues, please call me to set up a meeting time so we can discuss these matters. I can be reached at (253) 804-5031 or fax (253) 804-3114 or e-mail swagner@auburnwa.gov. To further assist your needs, the Auburn City Code can be reviewed in its entirety online at www.aubumwa.gov. Thank you for your attention to these details. Sincerely, hua Wagner, AICP, Planner Planning & Development Department Swlr CORR10-81 Enclosure: Redlines and Easement Agreement Sample cc: Bob Burton, Joe Welsh, Robert Elwell, Cynthia l.amothe, City of Auburn i inc. dmp, DALLY-MORROW-POBLETE,IN C. ENGINEERING-PLANNING-SURVEYING 726 Auburn WayNorth Aubum, WA 98002 May 26, 2010 " admah 4, *4 V Ilk Stuart Wagner City of Auburn 25 West Main Street. Auburn WA. 98001 RE: Tolas / Dulcinea Preliminary Plat-, 1 st Correction Letter, APN# 0921059090 Plat Application - PLT10-0001 Dear Stuart: We have received your first review letter dated March 8, 2010 and offer the following responses. We have attached our response below each original comment in BOLD. Public Works Department General 1. Water and sewer paybacks are assessed for this property. Fees will be due at first connection to utilities Comment Noted Survey Division 1. Title report from Pacific Northwest Title, Order Number 1108268 dated January 22, 2010 is within the 30-day window of the application date 2!8/2010. Future review will require an updated title report. Comment Noted 2. Map Page 1 of 4: ACC 17.10.020(D) (1) (e) stipulates an approval block for the City Council approval and signature by the Director-of Planning &-Community Development Department. This is needed on the plat. Ar> Comment Noted. Approval Block has been added. t any ..4O A110 G 1 James Tolas Plat - PLT10-0001 May 25, 2010 Page 2 of 8 Utilities - Water Division 1. There is an 8 inch water main south of the Applicant's parcel from which 4 duplex water services were constructed under an earlier project. The location of the duplex services does not align well with the proposed lot layout. Comment Noted. We will however make use of the existing facilities and cap the un-used connections. Minor relocation may be required. 2. The Applicant proposes to provide service to Lots 1 and 4 by installing the private service line back of the meter within the ROW to reach the two parcels. The Applicant shall either a) install new water service connections. to serve Lots 1 and 4 or b) install the private service lines outside of the ROW and across the adjacent parcels, and obtain access agreements across Lots 2 and 3. The new water services will be placed outside the R.O.W. Private easements will be provided over the affected lots. 3. The meter for Lot 5 is located in the driveway approach. Per City Design Standard 7.01.2.1.D, residential sites should have water meters placed in landscape strips within the right of way. If no unpaved areas exist in the right-of- way, water meters may be placed outside the right-of-way in unpaved areas within a public water utility easement. The driveway for Lot 5 will be relocated so that the meter is outside the driveway. 4. The Applicant's parcel is located within the critical area known as Ground Water Protection Zone 4. The Applicant shall implement best management practices for water resource protection per ACC 16.10.120(E)2. BMPs will be provided as part of the engineering plan approval. 5. Design of any water service improvements shall meet the requirements of City Design Standards Chapter 7 - Water Facilities. Water services will be per the City standards and will be shown on the engineering plans. James Tolas Plat - PLT10-0001 May 25, 2010 Page 3 of 8 Utilities - Sewer Division 1. The applicant has proposed sewer main extension onto the proposed property. That extension of the public system is not necessary, and it is preferable to have the individual lots connected to the sewer system via individual side sewers connected to the sewer main in 307th Street SE. The sewer easement would, therefore, be unnecessary. Comment Noted. 307th Street SE is a relatively new road and the existing sanitary sewer main is deep. The Applicant prefers to not cut and repave the street unnecessarily. We prefer to use the existing sewer stub and extend the system as proposed instead of disturbing the existing pavement. 2. FYI to applicant: As-built drawings show the end of the 8" stub being 7.2' deep (7' shallower than is shown on these plans). Thank You. The sewer profile was corrected. Utilities - Drainage Division No comment Traffic Division 1. Provide sight distance triangles at all site driveways. The Applicant is proposing to develop 6 single-family lots on an existing residential street, which was designed and constructed specifically to provide access to four duplex units. It is unclear why it is necessary to provide sight distance triangles for each home. Our Civil Engineer reviewed the Tolas Short Plat with regard to evaluating available entering sight distance as requested by the City of Auburn. A separate grading permit was obtained from King County in 2003 to construct the abutting frontage street improvements and site grading on the subject property. SE 307th Place, the fronting street serving the Tolas Short Plat, was designed and constructed as part of the local access residential street system that serves the Kingsley Meadows Subdivision. The Kingsley Meadows Subdivision and the roadways serving the plat were desired and constructed to King County Code requirements. Therefore, SE 307 Place was designed by a licensed professional civil engineer to meet,the 1993 King County Road Standards. This includes specific requirements for stopping and entering sight distance. Therefore, the horizontal and vertical alignments of all streets within the Kingsley Meadows Plat were approved by King County to be in accordance with said standards. At this time the James Toles Plat - PLT10-0001 May 25, 2010 Page 4 of S Kingsley Meadows Subdivision has been fully developed, including the construction of many single family residential homes on both the north and south sides of SE 307th Place. The site distance evaluation for the Tolas Short Plat was therefore limited to evaluating possible sight obstructions within the view triangle of the driveways serving the proposed residences on the north side of SE 307th Place. From field observations, and as shown in the attached photographs taken on April 29, 2010 at several driveway locations along the frontage of the Tolas property, it can be clearly seen that there are no sight obstructions blocking the view triangles to the east or west for right turning or left turning vehicles entering SE 307th Place. The only objects that are within the view triangles to the east and west are the existing street trees that were planted behind the sidewalks and these were installed as part of the required street improvements. However, the trees do not create a barrier that obstructs a driver's view of on-coming vehicles within the street or pedestrians using the abutting sidewalk system. In the future, it will be necessary to properly maintain (prune) the street trees to ensure that no branches are allowed to grow at a height or in a manner that will block a driver's view when entering the street. (Pictures taken on April 29, 2090 were from a position approximately 3 % feet off the ground and at a distance of approximately 14 % feet back from the travel lane) (Attachment A) 2. Provide a typical roadway section showing in cross section the location of pavement, sidewalk, landscape strip, trees streetlights. A typical roadway section of the existing street was added to Sheet 4 of 4. 3. Note on plans that no vehicular access will be granted by the City of Auburn to 124th Ave. SE via Tract A. While no access may be requested or approved with this plat application, the intent is to develop Tract A as part of a future development in which access to 124th Ave. SE may be required. That access will be reviewed under a separate permit. 4. An existing cherry tree is shown in the middle of the driveway of proposed lot 1, please address that issue by noting that tree will be relocated or that the driveway will be relocated. Comment Noted. A label was added as requested. James Tolas Plat - P1.T10-0001 May 25, 2010 Page 5 of 8 5. A water meter is shown in the middle of driveway for Lot 5, please address that issue by noting that meter will be relocated (or strengthened) or that the driveway will be relocated. A label was added as requested. 6. Submittal checklist (provided with application) Item I - the note that "no traffic impacts are expected" is not correct. No traffic study is required as a result of the low expected traffic impacts from the development but it should be noted that traffic impact fees will be required by the City at time of building permit for each residence. Comment Noted Item J - The surrounding existing street system (124th Ave SE a minor arterial and SE 304th a minor arterial) to this proposed plat does not provide a continuous sidewalk connection to Rainier Middle School, or the nearest elementary schools: Lea Hill or Hazelwood. As a result, the applicant's response to Item J does not constitute an adequate school access analysis as required. It implies that safe walking conditions exist to connect the plat to surrounding schools and they may indeed not. The applicant shall complete a thorough school access analysis which includes participation with and written response from the Auburn School District indicating whether students for this plat will likely be bused or required to walk to elementary, middle and high school. If they are required to walk to school, the school district should indicate to the applicant in writing whether those walking routes are considered safe walking routes to school. That documentation shall be provided to the city. As previously indicated, the subject property is surrounded by the recently completed plat of Kingsley Meadows. The Auburn School District reviewed and commented on that plat when it was approved. As part of the neighboring projects frontage requirements, pedestrian improvements were extended alogn SE 307th to the intersection with 124th Ave SE. The Dulcinea Plat takes access from the newly constructed SE 307th Place SE and the six proposed lots will utilize the existing pedestrian facilities. The Plat of Dulcinea Is located less then one block north of Lea Hill Elementary School. The existing pedestrian ! improvements and manned & signalized cross walk along 124th Ave SE provide safe walking conditions for school children. The Project is also only four blocks from Rainier Middle School which also has existing school walking route improvements. i James Tolas Plat PLT10-0001 May 25, 2010 Page 6 of 8 Please see the attached email from Dennis Grand of the Auburn School District Transportation Department. He confirms that the project is within the existing safe walking area. (Attachment B) Critical Areas Review 1. On the Master Land Use application, concurrent application sheet "Shoreline Exempt" is marked. No shoreline exemption is required since the proposed plat is not in the City's shoreline jurisdiction. Comment Noted. 2. SEPA may be required depending on the amount of grading proposed on the site (500 cubic yard threshold) and the potential presence of critical areas on-site. The project is SEPA exempt. As an exempt project, the grading specific provisions of the SEPA regulations do not apply. Those provisions apply only to grading applications that do not otherwise trigger SEPA under another permit review process. If you require further clarification, Please contact Annie Szvetecz at the DOE SEPA unit (360) 407-6925 3. City of Auburn critical areas maps indicate an erosion prone critical area on the northwest portion of the property. This area may constitute a Critical Erosion Hazard Area as defined in ACC 16.10.020 and 16.10.080.G.1. Critical erosion hazard areas are lands or areas underlain by soils identified by the U.S. Department of Agriculture Soil Conservation Service (SCS), now known as the Natural Resource Conservation Service, as having "severe" or "very severe" erosion hazards. This includes the following group of soils when they occur on slopes of 15 percent or greater: Alderwood-Kitsap (AkF), Alderwood gravelly sandy loam (AgD), Kitsap silt loam (KpD), Everett (EvD), and Indianola (InD). The project was originally reviewed under King County Grading permit L03CG178 and later L05G1021. As a result of that permit, the project site was significantly altered by the importation of approximately 13,000 cu yds of fill from the neighboring property and some additional off-site sources. While the area may fall under some portion of the Auburn critical area mapping system, the existing condition does not meet the definition for erosion hazards. The site has been engineered and altered through an approved permitting process. (Attachment C) James Tolas Plat - PLT10-0001 May 25, 2010 Page 7 of 8 4. While the submitted Kingsley Meadows geotechnical engineering study is nearby to the proposed Tolas Preliminary Plat, it does not appear to cover the project area. Comment Noted. The Kingsley Meadows study may not specifically cover the project site, but considering that there are no proposed public improvements, we are confident that any geotechnical review can be postponed to building permit review processes, if required. 5. A critical areas report and appropriate mitigation measures (including development setbacks) may be required for this proposal. Please consult a qualified geotechnical consultant to evaluate on-site conditions and complete any associated critical area requirements pursuant to Chapter 16.10 ACC. No critical areas exist on site. No mitigation measure will be required. Planning and Development 1. The purpose of Tract A needs to be stated on the preliminary plat. Please add a note to the preliminary plat stating its intended use and who will own it. Ex. Tract A is a future development tract and is retained by the owner of Tract A, its successors and assigns, for ownership and maintenance. Tract A will be re- platted or adjusted to... Comment Noted. 2. Please remove Tract B from the preliminary plat. While "tracts" are used and designated for specific purposes, one should not be created to handle encroachments. Please consider using an "easement agreement" between two parties to handle this situation. Attached is an example. Comment Noted. This issue has been resolved. The Tract will remain. 3. A public utility easement (P.U.E.) that is to be reserved and conveyed to Puget Sound Energy, Telecommunication companies, City of Auburn, and any other private utility company was not identified on the preliminary plat. Please indicate if this P.U.E. is already present or else add this easement to the preliminary plat. Comment Noted. James Tolas Plat - PLT10-0001 May 25, 2010 Page 8 of 8 Conclusion This proposal is the culmination of several previous permit applications, including the Kingsly Meadows Subdivision and the Tolas Grading permit. The subject site has been graded, utilities have been provided to the site and full frontage improvements have been constructed. The intent of this application is to make use of the existing facilities to develop 6-residential units, where 8-units were originally intended. The surrounding subdivision was reviewed and all required improvements were provided, sufficient to support the originally proposed 8-residential units. This included full street and pedestrian improvements. We look forward to working with Staff to approve this project as quickly as possible. Sincerely, Hans . Korve Planning Manager DMP Inc. Attachment "A" a - ~ i View West at 3.5' high and 14' from the travel lane Ii 'uV - i "W S NEI, - i View East at 3.5' high and14' from the travel lane Atuicilnlcnt "A" UnN y {o f, j°~ ➢ ~ '.ter. is F View East from existing driveway on SE 347t" Page I of 1 Attachment B Hans Korve From: Grad, Dennis [dgrad@auburn.wednet.edu] Sent: Monday, May 17, 2010 1:48 PM To: 'Hans Korve' Subject: RE: Tolas Preliminary Plat -School Walking Attachments: 20100503163634971, pdf The Parcel as described in the attached PDF is within the tea Hill walking attendance area. Dennis J. Grad Director of Transportation Auburn School District #408 (253) 931-4938 Fax - (253) 931-4706 Ix] TN00211_ From: Hans Korve [mailto:hans@dmp-inc.us] Sent: Monday, May 17, 2010 1:06 PM To: Grad, Dennis Subject: Tolas Preliminary Plat -School Walking Good Day- I received your message from Friday, regarding the school walking route. Unfortunately, the City of Auburn requires a written response. I believe a simple Email will be sufficient. Thank you for your time Hans 5/17/2010 Attachment "B" ( rk t m ,.F i, r Y .1. S - - _ r y4'~ fats T, f View North along the 124"' Ave SE School Walking Route s~ q i 4 n : f View South along the 124th Ave SE School Walking Route j s,•!~~+L -s1 ,1-~~1 AN ~y'Y~ 2CC,,~~~ Js'3i ,t ri 9 3 a{.'~rP,. ,kF a 'r 1 € ~ ~ j ' % cy l ^`>;f~S3 t~F 2.^1~•~I~~.y i ,,3- xb X21 #Sds F A; .r. ~t Z r~ a ...°,i•~'`r~}ti, r~. ~ L,. ~~~4,_ `~~.~F~..;~;-`'~fi.~?~xv^ ~"!v"~i f~`r: 1~.: rrs. >~~'-J'....-.:..._i,,:l a?~Fa! 3,~ E r.:,s 2,Y,i`s ak,-... t_., ci: ~E - - 1~- f r t y ~b iir~'d~l~ TwQ Fa s~ , ~Sk~• ~1 , ; a . ~ ! ~ i t ~f a , ' _ r - ~ ~ I.' ~ $ . k .f I jr, i~r b•. t % Y'A p I, n r T~►~ . Kent t - j, 1, :a f r e t s -3 ! i 4 SL 1Ia.ST n y 1 ( 1 - ii I5. fY ! 3,: P i j,_ 1&1 W t r,SV 5 r_ !i ; lil r s f!} 3 _ ,f r:, ! F it ice. n Ur t Fe{ f { k ,.fF' 1 r E~ ie. t x 'jst, _ i S ? n 1 i fol I r • f i.. 16 3 1'. HAZELWOOD _ a F 1 I i 1 k ELEM t RAINIER JR HI ! 1 r:•• P 'J~ t f 1 F r i i i i - Y ik r ` s 5~6~9QTHRT,s. 3 1:. 3 } CI s I' ,ECG i. eri 1 ` L t i .seaornl~r T 1 G se~7i'►i~, { { , fS r ; , , ~3AeT~IJRI^s ~ 3 ~ r c { r t 3.,.+.~, ~ q . + f , ~ I i a ` LEA HILL 3 1 ~b rn A } u i ELEMENTARY SCHOOL. i ! i tow S'f - - t-t= ~ z F t ' 7 I a- R 4 ...i ry 1 1%3f IT" teA•HILL RO a`~ _ i ' L;~ -3127H 31211# • „ ~ Sc r ~.w ~i;~,, ~ ~ 5 ~ ~ d ? , f i G r 1, i I 1, 9 . y. f _-4i 4 ! i~ 1 Ff6 1 1, + , (CIZGtNKLigCeunty a i1 i 1' F~ f I -2 F a. F 4 759k f t apP®en. !pd qr: ntYsl~Rlrgm a y ltety ot~ Qae ~sr4 ~npa w~ ,tang , j ds nn ~Fa $0 Bd'E9 OQ i 3$ + 4f }f ItOh 0 0U ad 1(1fQ/ftS011•!i ja;U ,7 ♦ t a,- r` 31~ 11p e t ".Ml a' ~(!~'3 ~ W 9 ttet c> > • w~ ~fh9l~~ PRPIS„~1~1 1¢ ttbt Ifryl~ll$e`ga a.trtr~ la® t!^s:~~~~ 9iI ~lQPy ea oC , : r~ A i~ q9 Jf1q~PY Wft e~s°;~atr~Y~~4~o~.W~tPt 1heUSd9~ 3 .I~e , 3 ~ ~ GI~ijfr~y`~Yu~` ~ q yle 1ST 7~¢y~~11~ a t~! , yCi~~;"L~ r,~.~•~ a - p 0C]!1[p1~ry~I1QP1 r18Q 9d e8fl9Rj y ~1 ¢arrtd~ii 2,, .2~ij'"~ y J' -`x tG~ ~f .f t ti ti 1 .:'1, kfr Pai ! 3 1 { r r° !~l f•-~r ~.,L.,r=~x..I s.,..., r?~r,.. ir- ;:t.,, _ rs~ ~ r_._h-,-...,x 0 ;QBe QlO, h,~^~>~s!rcpt`~?ub~Yt,~'?~I9P.?;~4'tritop!!t3'~!11~M,R'iN' .~6o,Y...:,,w!A'~"~~; ~ ~ t ~.,I~ Y - ~T r~ _ - tz: +yh. _ ~ ! t, ~ ~ 5 ~f:.♦ _ "~s ~ ~ 5 $ ~ m e _3 r ~ t ~ti u,~; s ; x . _ ,gig ttt` _ Rte,. ~yy ~ ~ 1 ¢rd 8 { F°~ - 1 y ~ - ~ ~ tjpy~} qk... _ 4 _ .~R_' • . ~~Yc s. P_T . s:, _3. n ~~.+~r + ~ ~ f r_ :8 - 'ii ~ ,,i ~ r Online Search & Report Page 1 of 1 Attachment C Permit at a Glance Enter permit L03CG178 or Parcel ID number (PIN): Submit or file number: (6-10 digits, e.g., 2123069016) Title Permit routing Building inspection ~ comments ~ Related permit activities Title TO Top Details of the permit itself Status definitions Permit Information Contact Information Project No: L03CG178 Applicant: AUBURN 56, LLC Status: COMPLETE Applicant 7947 159TH PL NE #100 Title: TOLAS GRADING address: REDMOND WA 98052 Permit type: GRADE Assigned staff: JBAL Sub-type: GRADING Contractor: Contractor Applied/Opened: 05129/2003 address:11 Approval/Decision: 08/12/2003 Expiration Date: 08/28/2004 Site Information No. Completed Date: 12/13/2006 Valuation: Lots: 9 $0.00 Description: Grading of approx. 13,000 cu. Location & AU yds. for future development. Jurls.: Community SOOS CREEK Plan: Comp Plan: URBAN RES 4-12AC Owner: JAMES TOLAS/DOLCINOA DEVELOPMENT Parcel No: 0921059090 (Link to Parcel Viewer Map) Link to: Property Report Districts Report IMan TO TOP Permit routing * Building inspection function status TO TOP TO TOP ~ Comments Related permit activities on parcel TO TOP For more information about categories and statuses used on reports, see: • Category descriptions for a list composition types and sub-types for each report grouping. Also refer to each permit type for additional details. • Status definitions for general definitions for statuses such as pending, approved, finaled, etc. • Permit routing status definitions for general definitions for statuses that are used by PRMS - Permit routing management system. Please e-mail questions or comments to DOESWebinquiries(a)kingcounty._ ov. httn://info.kinecounty.uov/orot)erty/neiTnits/PermitGlance/(S(okkIOufn2xakitav5avivnvi-n))/.. 4/70(110 Online Search & Report Page 1 of 4 Permit at a Glance Enter permit L03CG178 or Parcel ID number (PIN): j Submit or file number: (6--10 digits, e.g., 2123069016) Title Permit routing Building inspection comments Related permit activities Title TO TOP Details of the permit itself Status definitions Permit Information Contact Information Project No: L03CG178 Applicant: AUBURN 56, LLC Status: COMPLETE Applicant 7947 159TH PL NE #100 Title: TOLAS GRADING address: REDMOND WA 98052 Permit type: GRADE Assigned staff: JBAL Sub-type: GRADING Contractor: Contractor Applied/Opened: 05/29/2003 address: ApprovallDeclsion: 08/12/2003 Expiration Date: 08/28/2004 Site Information Completed Date: 12113/2006 No. Lots: 9 Valuation: $0.00 Description: Grading of approx. 13,000 cu. Location & AU yds. for future development. Community Juity SOOS CREEK Plan: Comp Plan: URBAN RES 4-12AC Owner: JAMES TOLAS/DOLCINOA DEVELOPMENT Parcel No: 0921059090 (Link to Parcel Viewer Map) Link to: Property Report Districts Report N-12 0 Permit routing To Lop 0 Building Inspection function status TO TOP Comments TO TOP Keyword: Search keyword PermitsPlus LSDSJBAL 5/2912003 5129103 - Ballweber - met with Jennifer Steig of Peterson Consulting Engineers, and accepted the grading permit application packet for approx 13,000 cubic yards of grading on the Tolas Short Plat site, LOOS0029. The majority of the fill is proposed to come from the grading of the Kingsley Meadows Plat, L01 P0015, which borders this property on 3 sides. SEPA had not been done for the SP, and the SEPA determination for Kingsley Meadows did not include this grading work. LSDSJBAL 5/29/2003 5/29103 - Ballweber - discussed the SEPA issue with Fereshteh Dehkordi, as she is assigned to the Tolas SP, LOOS0029. She will do the SEPA determination for this project. httt):Hinfo.kinpcountv.pov/property/permits/PermitGlance/(S(okkIOufn2xaki tav5avivnvm))/... 4/7/2010 Online Search & Report Page 2 of 4 . i i LSDSJBAL 5129/2003 5/29/03 - Ballweber - discussed possible wetland Issues with Nick Gillen. The wetland in the NW corner of the site is <2,500 sq ft in size, and the property is in the urban area thus, the wetland is unregulated, and no wetland review/approval is recd. HINTZT 6/4/2003 Routed to LWES BROWNJOA6/5/2003 Corrected/completed screens. Entered and posted fees and did routing. Sent SEPA Notice of Complete Application posting package to applicant, copy to Greg Borba along with checklist, plans. Turned on clock. GOLLS 616/2003 SEPA file routed to assigned Planner, AVEL, via GBOR BROWNJOA6/6/2003 06-05-03 Sent SEPA NOA posting package to applicant, and copy with checklist, plans to Greg Borba. Turned on clock. BROWNJOA6/1212003 Notified newspapers (Seattle Times, King County Journal). Publishing date is June 18, 2003. BROWNJOA6112/2003 Rec'd Affidavit of Posting. Added to SEPA docs. file. BROWNJOA7/17/2003 Prepared Threshold Determination and Notice of Determination mailing for tomorrow. LSDSJBAL 7121/2003 7121103 - Ballweber - faxed comments, ESC and grading/GEO notes from LWES to Peterson Consulting. LSDSJBAL 8/5/2003 814/03 - Ballweber - rec'd revised grading/ESC/drainage plans. Reviewed grading and ESC components. Routed plan set to Jerry Walken for drainage review. LSDSJBAL 8/5/2003 815103 - Ballweber - Jerry Walken e-mailed review comments back to Peterson Consulting.... still need to address the interim drainage system. GOLLS 8/11/2003 SEPA DNS ISSUED 7/18/03; COMMENT PERIOD ENDS 8/11103 GOLLS 8/11/2003 updated permits plus SEPA info LSDSJBAL 8/11/2003 817/03 - Ballweber - recd 5 copies of revised grading/drainage/ESC plans from Peterson Consulting. LSDSJBAL 8/13/2003 8/11/03 - Ballweber - prepared and faxed draft RTI packet to Peterson Consulting Engineers.... if no SEPA comments/appeals are recd by COB today, this draft will be the final tomorrow, 8/12/03. LSDSJBAL 8/13/2003 8/13103 - Ballweber - updated routing.... approved EENG and GEO stations, as they have approved the plans earlier. LSDSJBAL 8/13/2003 8/12103 - Ballweber - checked w/SEPA...no comments/appeals have been recd. LSDSJBAL 8/13/2003 8/13103 - Ballweber - spoke w/Rebecca Saur of PCE.... they are securing bonds, and RTI forms have been signed. They requested that they provide insurance certificate at pre-con this is OK. They also want to schedule a day/time for permit issuance.... will schedule w/RSAN. LSDSJBAL 8/13/2003 8112103 - Ballweber - final plan review w/JWAL..... plans approved. LSDSJBAL 8/13/2003 8/12103 - Ballweber - e-mailed Peterson Consulting Engineers that draft RTI documents are final, as no SEPA comments/appeals were rec'd, and that plans have been approved. LSDSJBAL 8/28/2003 8128/03 - Ballweber - Rebecca Saur of PCE submitted signed documents from RTI list. Fees have already been paid, and bonds posted. Insurance certificate will) be submitted at pre-construction conference, as agreed to earlier. RSAN issued permit. 2 copies of permit documents and approved plans given to Rebecca Saur. LSDSJBAL 91412003 9/3/03 - Ballweber - checked Vintage Hills 6 & 7...... there is alot of excess material stockpiled in the SW corner of Vintage Hills 6, and more material is being generated by installation of underground utilities. This site Is approx 0.5 miles north of Tolas. LSDSJBAL 914/2003 9/3103 - Ballweber - held pre-construction conference with Mark Follmer/LUIS, Dustin Dance and Scott Langevine of CC Edwards/contractor, and Craig Sears of Auburn 56/applicant. Reviewed approved plans and permit conditions. They anticipate having to import fill from other construction sites, such as Vintage Hills 6 & 7, as Kingsley Meadows does not have as httn://info.kinL,cotinty.Env/nronerty/nermits/PermitCTlante/(C(nkki0iifn~xakitavSaviv„vmll/ al?l')nt n Online Search & Report Page 3 of 4 much fill material to export to this site as earlier estimated. LUIS will inspect the catch basin and stub into the Kingsley Meadows drainage system, and SDSS will inspect fill placement and ESC.... also, compaction reports prepared by Earth Consultants are to be submitted to SDSS. LSDSJBAL 5/12/2004 5/11/04 - Ballweber - on-site grading/ESC inspection. Catch basin stub w/riser and sits fencing installed in NW corner of property, per plans. However, filling of property does not appear to be complete. Most of the fill has been hydroseeded, but Kingsley Meadows lots to the south and west are graded and bare, ready for house construction. Will contact applicant about future plans. LSDSJBAL 5/12/2004 5112104 - Ballweber - researched file..... according to plans and bond posted, 48 - 3" caliper conifer trees are to be planted on-site, but have not yet been planted. It's too late in the year to plant these trees........ they should have been planted this past winter. Called and left message for Craig Sears, applicant, to call me back with update on development plans. LSDSJBAL 1/11/2005 1/11105 - Ballweber - on-site w/Eric Mullin fo Pacific Landscape Mgmt, at Craig Sears' request, to review installation of significant tree replacement trees. The required number, size and species of trees were planted in late November of 2004, and appear healthy. The remainder of the site has been stabilized for ESC and interim drainage - however, it does not appear that clearing/filling/grading is complete. Send renewal notice. BROWNJOA 1/19/2005 EXTENDED -see L05G1021. AINSLIER 12/13/2006 rec'd old file of jim b. permit extended and renewal expired. field check shows most of grade work done. met briefly wit tim c, whos said short pist permit issued. close this permit, microfilm and archive. AINSLIER 12/13/2006AINSLIER changed status to COMPLETE on 1 211 3/2 0 0 6 (added by script) ADMIN 9/15/2008 As a result of a claim filed under the Tiger Mtn LLC vs King County lawsuit, a refund was remitted in the amount of $120.40. For detailed information contact DDES Finance Section. PRMS routing LUISJWAL 8/19/2003 RECEIVED REVISE PLANS TOWNSENDS 8/19/2003 RECEIVED at Land Use Engineering 8/19/2003 FINISHED at Land Use Engineering TOWNSENDS 8/19/2003 REVISED PLANS RECEIVED LSDSJBAL 8/28/2003 FINISHED at Ready To Issue LSDSJBAL 8/28/2003 Permit issued by RSAN YASMOOTHRT9/2/2003 Review added YASMOOTHRT9/2/2003 FINISHED at Land Use Inspection Plans YASMOOTHRT9/2/2003 set up a file today BROWNJOA 1/19/2005 FINISHED at Grading-Inspect PRMS clock BROWNJOA6/5/2003 LSDSJBAL 7/21/2003GEO and ESC comments faxed to Peterson Consulting. LSDSJBAL 7/21/2003 ENGG comments to Peterson Consulting on 7/9/03 LSDSJBAL 6/13/2003 Plans approved, RTI packet faxed to Peterson Consu LSDSJBAL 811 312 0 0 3 Revised plans approved by JWAL and JBAL. RTI packe LSDSJBAL. 8/13/2003 Revised plans submitted by Peterson Consulting LSDSJBAL 8/13/2003 WCI....plans inadequate. JWAL has contacted Peters LSDSJBAL 8/1312003 Revised plans submitted by Peterson Consulting, ad PRMS Milestone No comments available for L03CG178 httn-//infn.kinarrnmtv.anv/nrnneity/ner•mite/PPrmitC'Tlanr.P/(,(nkklOiifn7xakitnv5avivnvm)l/ d/7/7()1(1 Online Search & Report Page:.4 of 4 0 Related permit activities on parcel To TOP For more information about categories and statuses used on reports, see: o Category descriptions for a list composition types and sub-types for each report grouping. Also _ refer to each permit type for additional details. e Status definitions for general definitions for statuses such as pending, approved, finaled, etc. Permit routing status definitions for general definitions for statuses that are used by PRMS - Permlt routing management system. Please e-mail questions or comments to DDESWebinquiries _kinacounty.gov. i i i _ I _ I I - I i I I httn•/Anfn lrinarnnntvPvnv/r~rnnP.rfv/nPrinitc/PermitlTlannP/(C(nlrkl(1nfn7valritA~~Sa~~ivnvmll/ G/7001 n Online Search & Report Page 1 of 1 Permit at a Glance Enter permit L05G1021 or Parcel ID number (PIN): I Submit or file number: (6-10 digits, e.g., 2123069016) Title Permit routing Building inspection comments Related permit activities ° Title TO TOP Details of the permit itself Status definitions Permit Information Contact Information Activity No: L05GIO21 Applicant: AUBURN 56, LLC Status: COMPLETE Applicant 15 LAKE BELLVUE DR SUITE Title: TOLAS GRADING address: 102 Permit type: G-INSPCT BELLEVUE, WA 98005 Sub-type: INSPGRAD Assigned staff: FWHI Contractor: Applied/Opened: 01/19/2005 Contractor Approval/Decision: 01/19/2005 address: Expiration Date: 08/28/2005 Site Information Completed Date: 12/08/2005 Valuation: $0.00 Description: Grade approx. 13,000 cu. yds. Location & AU Juris.: for future development. Community SOOS CREEK Plan: Comp Plan: URBAN RES 4-12AC Owner: TOLAS JAMES/DOLCINOA DEVELOPMENT Parcel No: 0921059090 (Link to Parcel Viewer Map) Link to: Property Report Districts Report L Map 6 Permit routinq TO TOP 0 Building inspection function status TO TOP 0 Comments TO TOP 0 Related permit activities on parcel TO TOP For more information about categories and statuses used on reports, see: e Category descriptions for a list composition types and sub-types for each report grouping. Also refer to each permit type for additional details. • Status definitions for general definitions for statuses such as pending, approved, finaled, etc. . Permit routing status definitions for general definitions for statuses that are used by PRMS - Permit routing management system. Please e-mail questions or comments to DDESWebinquiries(@kingcounty.gov. httn•//infn lrinnrrnmhi nnu/nrnnarhv/nermitc/PPrmitCY1nnrP/(R(invwh7rniOn1vn55mumhhen0 1/70010 Online Search & Report Page 1 of 1 Permit at a Glance Enter permit L05G1300 or Parcel ID number (PIN): Submit or file number: (6-10 digits, e.g., 2123069016) Title Permit routing Building inspection Comments Related permit activities Title TO TOP Details of the permit itself Status definitions Permit Information Contact Information Activity No: L05G1300 Applicant: AUBURN 56 LLC Status: COMPLETE Applicant 15 LAKE BELLVUE DR SUITE Title: TOLAS GRADING address: 102 Permit type: G-INSPCT BELLEVUE, WA 98005 Sub-type: INSPGRAD Assigned staff: RAIN Contractor: AppliedlOpened: 12/0812005 Contractor A roval/Decision: 12/08/2005 address: Expiration Date: 08/28/2006 Completed Date: 03/06/2008 Site Information Valuation: $0.00 Description: Grade approx. 13,000 cu. yds. Location & AU for future development. Ju Community nity SODS CREEK Plan: Comp Plan: URBAN RES 4-12AC Owner: DULCINEA DEVELOPMENT Parcel No: 0921059090 (Link to Parcel Viewer Map) Link to: Propert y Report Districts Report --p 0 Permit routing TO TOP 0 Building inspection function status TO TOP TO TOP 0 Comments 0 Related permit activities on parcel TO TOP For more information about categories and statuses used on reports, see: • Category descriptions for a list composition types and sub-types for each report grouping. Also refer to each permit type for additional details. • Status definitions for general definitions for statuses such as pending, approved, finaled, etc. • Permit routing status definitions for general definitions for statuses that are used by PRMS - Permit routing management system. Please e-mail questions or comments to DDESWebinquiries(a)kingcounty.gov. httn:Hinfo.kingeountv.sov/nronerty/permits/PerniitC-tlance/(g(thei-ot5.5catntb7,kx2Sl vv55)1/P 4/7/7(11 o CITY OF U Peter B, Lewis, Mayor -XnDURN* WASHINGTON 25 West Main Street * Auburn WA 98001-499II * www.auburnwa.gov 253-931-3000 April 29, 2011 James Tolas dba Dulcinea Development 3618 Lakerldge Drive E. Sumner, WA 98390 Hans Korve dba DMP Inc. 726 Auburn Way N. Auburn, WA 98001 Re: Tolas / Dulcinea Preliminary Plat - 2na Review Letter, APN# 0921059090 Plat Application PLT10-0001 Gentlemen: The City of Auburn received the resubmittal package for the above referenced project on April 7, 2011. Staff has reviewed the submitted information and has the following comments: Public Works Department General 1. Water and sewer paybacks are assessed for this property. Fees will be due at first connection to utilities. 2. Note to Applicant: Driveway location may. have to be relocated if conflicts come up. Survey Division 1. Title report from Pacific Northwest Title, Order Number 1108268, dated January 22, 2010 is not wllhin the 30-day window of the current review. An updated title report, current within 30 days, is needed. 2. Map Page 2 of 4: Note Number 2 on this page indicates that Tract B, an encroachment tract, shall be conveyed to the owners of Lot 44, Kingsley Meadows, upon the recording of this plat. Our Legal staff should be consulted to determine if the owners of Lot 44 need to sign the final plat as owners of a portion of the site being platted. Utilities - Water Division No comment Utilities - Sewer Division 1. Connect each individual lot to the existing sewer main in SE 307th Place via a 6" diameter side sewer. The public sewer extension is not necessary. AUBURN* MORE TI-IAN YOU IMAGINED James Tolas and Hans Korve - PLT10-0001 April 29, 2011 Page 2 of 2 Please contact Bob Elwell, Sewer Utility Engineer, (253) 931-4008 or relwell a atlburnwa.gov for questions related to Sewer comments. Utilities Drainage Division 1. All surface runoff shall be contained on-site. Proposed grade shown in section AA & BB could result in off-site runoff on the west side of the property. Traffic Division 1. Show existing street lighting on the existing roadway cross section. Please contact Joe Welsh, Transportation Planner, at (253) 804-5050 or jwelsh@auburn.wa.gov for questions related to Traffic comments. Planning and Development 1. The note/description for Tract A - Future Development Tract needs to be expanded. The note needs to reference a land use decision that will allow it to be developed at a future date. Ex. "Future development of this tract can only occur-through approval of a plat alteration or other subdivision application filed with the City of Auburn" 2. Sheet 1 of 4. Correct the signature block for the Director from `Planning & Community Dept' to "Planning and Development Department". And change the year to 2011. 3. Sheet 2 of 4. A spelling error was found within the first note i.e. Tract A is a future development tract (instead of futer) Please contact Stuart Wagner, Planner, at 253-804-5031 or swagt)er@alibtirnwa.gov with questions regarding these comments. Conclusion Should you have any questions regarding this letter or outstanding permit issues, please call me to set up a meeting time so we can discuss these matters. I can be reached at (253) 804-5031 or fax (253) 804-3114 or e-mail swagner@aubtiritwa.gov. To further assist your needs, the Auburn City. Code can be reviewed In its entirety online at www.auburnwa.gov. Thank you for your attention to these details. Sincerely, Stuart," ner, AICP, Planner Planning and Development Department CORR11-254 Enclosure: Redlines inc. dmp, DALEY-MORROW-POBLETE,INC. ENGINEERING-PLANNING-SURVEYING 726 Auburn Way North Auburn, WA 98002 May 17, 2011 Stuart Wagner City of Auburn 25 West Main Street. Auburn WA. 98001 ,F CITE . PERMiT F RE: Tolas / Dulcinea Preliminary Plat - 2nd Correction Letter, APN# 0921059090 Plat Application - PLT10-0001 Dear Stuart: We have received your first review letter dated April 29, 2011 and offer the following responses. We have attached our response below each original comment in BOLD. Public Works Department General 1. Water and sewer paybacks are assessed for this property. Fees will be due at first connection to utilities Comment Noted Survey Division 1. Title report from Pacific Northwest Title, Order Number 1108268 dated January 22, 2010 is not within the 30-day window of the current review. An updated title report is required. Comment Noted. Update provided. 2. Map Page 2 of 4: Note No. 2 regarding encroachment Tract B. Comment Noted. Additional language has been provided for your review. James Tolas Plat - PLT10-0001 5/17/2011 Page 2 of 3 Utilities - Sewer Division 1. The applicant has proposed sewer main extension onto the proposed property. Your proposed sewer extension for this plat would result in a public sewer main that is parallel to and redundant to the line in 307th Street. Based on the long- term maintenance implications to the City we will require that the sewer connection for each house be made directly to the existing public sewer main in 307th Street. (this is a summary of the Staff position and not a direct quote) Comment Noted. The Applicant proposal is consistent with all previously approved developments in this area. 307th Street SE is a relatively new road that was constructed as part of the Kingsley Meadows Plat. The utilities installed with that development were reviewed and approved by the City of Auburn for that project. Development of the Tolas site was part of that review. We have attached a copy of a July 24, 2006 letter from the City of Auburn addressing the extension of availability certificates for the property. As you can see, even at that time, the City was well aware of the Applicants proposal to develop a series of duplex buildings. The extension was granted and the services constructed. If it was not the Cities intent to service the 8 unit development with a parallel sewer main, then what was the proposal? The City of Auburn reviewed, approved and allowed construction of the existing sewer service (8" stub) to this property as part of a proposed 8 unit (4 structure ! lot) duplex development under King County. The property was also provided with 8 individual water connections. The Applicants current proposal is to service two less homes then was originally approved. While we understand that standard operating policy does not promote parallel sewer service on a property, this is what was designed, approved and installed. We are happy to work with Staff to find a creative solution to the situation. However, the Applicant intends to make use of the existing 8" sewer main that serves the property and will not unnecessarily excavate and repave 324' of new road. Our current proposal indicates a public sewer extension along the frontage of the proposed lots and the installation of 2 new manholes. The Applicant is open to the use of a private service extension if that will address Staff's concerns. We are also open to installing a manhole at the end of the existing 8" main stub and feeding 6 individual side sewers from it into a network of private utility easements. This is obviously no a preferred option. We would also entertain a third option if one is available. James Tolas Plat - PLT10-0001 5/17/2011 Page 3 of 3 Utilities - Drainage Division Review proposed grading to insure water stays on-site Grading has been revised and a ditch has been added to sections AA and BB. Traffic Division 1. Show Street lights on existing cross section. Comment Noted. Cross section was updated. Planning Division 1. Expand Note for Tract A. Comment Noted. A label was added as requested 2. Sheet 1 of4. Correct signature block Comment Noted. A label was added as requested. 3. Sheet 2 of 4. Spelling error Comment Noted. Conclusion This proposal is the culmination of several previous permit applications, including the Kingsly Meadows Subdivision and the Tolas Grading permit (King County). The subject site has been graded, utilities have been provided to the site and full frontage improvements have been constructed. The intent of this application is to make use of the existing facilities to develop 6-residential units, where 8-units were originally intended. The surrounding subdivision was reviewed and all required improvements were provided, sufficient to support the originally proposed 8-residential units. The City of Auburn was fully involved in all aspects of this review as the water and sewer provider. We look forward to working with Staff to approve this project as quickly as possible. Sincerely, Hans A. Korve Planning Manager DMP Inc. C1 IN 01' Peter B. Lewis, Mayof WAS I I I NGI ON 25 West Main Slroet ~ Auburn VIA 96001-4996 ¢ vrwvj,aubumWO.9oV ~ 21,,3.431-3000 July 24,2006 Mr. James Tolas 3618 Lakeridge Drive East Sumner, Washington 96390 SUBJECT: WS00010-99 - Extension Request' Dear Mr. Tolas: The City is in receipt of your July 19, 2006 letter requesting an extension of water and sewer availability certificates for a four lot short plat. Your letter also indicates that the intent now is to construct duplexes rather than single family dwellings. As you are aware, in approving the outside utility extension agreement, the City Council and applicant agreed to several conditions of approval (see page 5 of the enclosed recorded agreement). Before we will grant an extension and/or reissue the certificates, we need to verify that these conditions have and/or intend to be satisfied. That can best be done with the submittal of the recorded short plat (or latest proposal if the short plat has yet to be recorded) for our review. It would also be helpful to supplement that submittal with documentation of the issue(s) that have caused the delay at King County. Upon submittal of the short plat and our subsequent verification that the requirements have been (or still intend to be) met, the City can review the extension request. Thank you again for your letter. Sincerely, David Osaki Community Development Administrator Enclosure, cc: ( Carolyn Brown; Planning Secretary Darcie Hanson, Development Review Coordinator WSC0010-99 file A1 1R1 IR NJ MnR F THAN W)I I IMAC.INIFn